Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Graphics Diagnostic Terminal

PSS/SafetyBUS p and PNOZmulti Diagnostics


PMImicro diag

pad with 4 navigation keys and 3 Communication between PMImicro


function keys diag and the PC is via one of both se-
` Interfaces rial interfaces.
– Two serial inerfaces: RS 232 and As PMImicro diag is supplied with de-
RS 485 fault settings, it can immediately be
– CompactFlash card slot used for standard diagnostics (without
` software user messages).
– Diagnostics of system, MBS The diagnostics data can be displayed
(modular block system PSS) and in English or German. Other languages
application program are stored in the system software of
– Configuration the connected device, they can be
– Log function transferred to PMImicro diag.
Compact graphic diagnostics terminal ` Direct communication between PC A Unicode character set is used for the
for economical diagnostics with serial and PSS possible via PMImicro messages. It includes defined charac-
interface for connection to a device diag ters of Basic Latin (ASCII/ISO646) and
that is PVIS compatible. ` Real-time clock Latin-1 (ISO 8859-1).

Approvals Unit description Display/operator elements

The diagnostics terminal PMImicro Advertisement


PMImicro diag diag is used for diagnosing PVIS com-
patible devices. PVIS compatible de-
vices are: ` Graphic LCD module with 128 x 64
‹ ` PSS-range programmable safety pixels
systems with an FS operating sys- – Display area 56,94 x 37,42 mm
tem version ≥ 47. ` 6 x 8 pixels (2,7 x 4,7 mm) character
Unit features ` PNOZmulti safety relays: height for standard texts
– PNOZ m0p from Version 2.0 ` Back lighting 6x selectable
` Display – PNOZ m1p from Version 5.0 ` Contrast selectable
– Graphics LCD module – PNOZ m2p from Version 2.0
– 2,8“/70 mm; 128 x 64 pixels Diagnosing the PNOZmulti safety re-
– Font sizes: 6 x 8 pixels lays via virtual outputs is also possible. Operator elements
(2,7 x 4,7 mm). The diagnostics include system mes-
– Transreflective with LED back- sages, MBS messages, and user-de- ` Operator panel/membrane keypad
ground lighting; selectable fined messages. (with tactile feedback)
` Keyboard – 4 navigation keys and 3 function
– Operator panel/membrane key- keys

Front view

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Graphics Diagnostic Terminal

PSS/SafetyBUS p and PNOZmulti Diagnostics


PMImicro diag

Function Description tion is created by the user himself and processed and evaluated on the PC.
is entered in the PNOZmulti Configura- Changes and updates to the message
The controller's messages are catego- tor. texts can be transferred via one of the
rised as errors, warnings, and status The currently existing events are dis- serial interfaces or via CompactFlash
information, and they are displayed played with an event text and up to 8 card to the device. It is possible to up-
appropriately. The diagnostics data remedy tests for troubleshooting and date the runtime and the firmware.
are sorted by priority. fault recovery. All the settings on the device are made
When performing diagnostics on the The messages will be saved in the log using the navigation and function keys
PNOZmulti a location description is file. The saved data can be exported to or via the system software of the con-
also displayed. The location descrip- a CompactFlash card and then be nected device.

Connection example: PSS/SafetyBUS p

Connected
device CF-Card

PC
RS 232 RS 485 RS 232

5 or 6
1 2
PMImicro diag RS 232/RS 485
3 or 4 Converter
RS 485 RS 232

or

RS 232 RS 485
2

Wiring

To ensure trouble-free operation, ` The interference voltage from sup- current of 15 IN (15 x nominal cur-
please comply with the safety ply and signal lines and the electro- rent).
guidelines listed below. static voltages transferred by ` Please note during diagnostics on
contact are diverted via the earthing the PNOZmulti. The RS 232 inter-
` When choosing an installation site, point (ring lug, 4 mm thread or faces on the PNOZmulti and PMIm-
keep as large a distance as possi- press nut on the rear of the unit). icro diag do not have galvanic
ble between the system and any Connect this earth point to the pro- isolation. Any potential difference
electromagnetic fields. This applies tective earth PE via as short a cop- between the power supplies could
in particular when frequency con- per conductor as possible (cross- destroy the RS 232 interface. Con-
verters are nearby. section 2,5 mm2)! nect the PNOZmulti and PMImicro
` Inductive loads (e.g. contactors, re- ` Twisted pair, screened cable must diag to the same voltage source!
lay coils, and solenoid valve coils) be used to connect the interfaces.
within the environment, in particular ` Only use metal plugs or metallised
when they are fed from the same plastic plugs to connect the con-
supply voltage, must be wired with nection cables!
suppression elements (e.g. RC ele- ` We recommend you configure a
ments). safety screening on both sides for
` Power cables should be laid sepa- cable connections between two de-
rately to data line connections to vices.
avoid capacitive and inductive ` The power supply for the supply
transmission (recommended mini- voltage to the display system must
mum distance = 10 cm/3.94")! be designed for a peak switching

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

-2
Graphics Diagnostic Terminal

PSS/SafetyBUS p and PNOZmulti Diagnostics


PMImicro diag

Preparing for operation

` Interfaces

View with interfaces


1: Supply voltage connection RS232 RS485

2: RS 232 (COM1) INPUT 24V/DC


LAN
3: RS 485 (COM2) 4 321
ON
OFF

+ 24 V
4: Termination RS 485

0V
1 2 3 4

` Interface configuration

RS 232 interface Assignment


Connectors: Male 9-pin D-Sub con- 1: DCD
nector 2: RxD
View of the contacts 3: TxD
4: DTR 1
5: GND
6
6: DSR
7: RTS
9 5
8: CTS
9: n.c.

n.c. = not connected

RS 485 interface Assignment


Connectors: Male 9-pin D-Sub con- 1: n.c.
nector 2: n.c.
View of the contacts 3: B (485 -)
4: n.c.
1
5: GND 6
6: n.c.
7: A (485 +)
8: n.c. 9 5
9: n.c.

n.c. = not connected

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Graphics Diagnostic Terminal

PSS/SafetyBUS p and PNOZmulti Diagnostics


PMImicro diag

` Termination

Termination RS 485 interface Termination off Termination on


Termination off: RS485 RS485
Switch 4 ... 1: off
Termination on:
Switch 4: on,
Switch 3 ... 1: off
ON ON
OFF OFF
4 321 4 321

` Voltage supply

Rated supply voltage: 24 VDC 1: Supply voltage connection


2. Earth connection (M4)
INPUT 24V/DC

+ 24 V

0V
1 2

` Slot CompactFlash card

Slot: 50-pin Side access (1)

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

-4
Graphics Diagnostic Terminal

PSS/SafetyBUS p and PNOZmulti Diagnostics


PMImicro diag

Dimensions

Installation

` The unit should be installed in a

2.598"
3.071"

66
78
control cabinet, front panel, or con-
sole. The wall thickness should be
between 2.5 mm and 5 mm.
` To avoid the build-up of heat, a dis- 148 51
tance of 10 cm/3.94" should be 5.826" 2.008"
maintained all round the unit.
` IP65 protection can only be guaran- 135,8
teed when the fixing screws on the 5.354"
unit are firmly in place and the gas-
ket is not damaged.

0.28"
Notice Mounting cut-out 7,3

This data sheet is only intended for use


during configuration. For installation
68 +0,7
2.677"
and operation, please refer to the op-
erating instructions supplied with the
unit.

138 + 1
5.433"

Technical Details

Electrical data
Supply voltage 12 ... 32 VDC
Rated supply voltage 24 VDC
Power consumption 2.5 Watt
Display
Display type LC-DotMatrix Grafik-Modul
Resolution 128 x 64 Bit
Display range 60 x 40 mm (W x H)
Backlight White LEDs
Interfaces
Serial interfaces 1 x RS 232
1 x RS 485
Cable run RS 232: 10 m
RS 485: 1000 m, max. 110kBit/s
CompactFlash card slot 50-pin
Computer
Processor RISC processor
Operating system µClinux
Memory 8 MByte Flash
32 MByte SDRAM
Real-time clock Battery-buffered real-time clock

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Graphics Diagnostic Terminal

PSS/SafetyBUS p and PNOZmulti Diagnostics


PMImicro diag

Environmental data
EMC
Noise immunity EN 61000-6-2, 10/01
Noise emission EN 55022 Class A, 04/03
Protection type (EN 60529, 02/00) Front: IP65, back: IP20
Ambient temperature (EN 60068-2-14, 11/99) 0 °C ... +55 °C
Storage temperature (EN 60068-2-1/-2, 07/94) -25 °C ... +70 °C
Climatic suitability (EN 60068-2-78, 10/01) Max. 95 % r. F.; at 40 °C
Condensation Not permitted
Vibration in accordance with (EN 60068-2-6, 04/95)
Frequency 10 ... 150 Hz
Amplitude 1g constant
Shock (EN 60068-2-27, 03/93) 15g, 11 ms
Mechanical data
Housing material
housing Stainless steel
front ABS Polyflam, UL listed
Dimensions (with front) (H x W x D) 78 mm x 148 mm x 57 mm
Modular depth 51 mm
Weight 370 g

Order reference

Description Features Order no.


PMI m107 diag PSS/SafetyBUS p and PNOZmulti 260 000
or PNOZmulti vIO Diagnostics
Download cable RS 232 (1) PSS - PMImicro 301 960
Download cable RS 485 (2), PSS - PMImicro 374 205
Null modem cable RS 232 (3) PNOZmulti - PMImicro 301 965
Null modem cable RS 232 (3) PC - PSS 310 300
Interface adapter RS 232/RS 485 (5) PC - PMImicro 305 159
Interface adapter RS 232/RS 485 (6) with integral power supply; use 305 155
only on PSS/SafetyBUS p Diag-
nostics
PMI fastening kit 310 396
PMI power connector 269 700
Gasket PMI 269 701
CompactFlash card 64 MByte 310 382
CompactFlash card 128 MByte 310 384
Adapter PCMCIA to CompactFlash 375 300

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06