Graphics Diagnostic Terminal: Pmimicro Diag
Graphics Diagnostic Terminal: Pmimicro Diag
Front view
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Graphics Diagnostic Terminal
Function Description tion is created by the user himself and processed and evaluated on the PC.
is entered in the PNOZmulti Configura- Changes and updates to the message
The controller's messages are catego- tor. texts can be transferred via one of the
rised as errors, warnings, and status The currently existing events are dis- serial interfaces or via CompactFlash
information, and they are displayed played with an event text and up to 8 card to the device. It is possible to up-
appropriately. The diagnostics data remedy tests for troubleshooting and date the runtime and the firmware.
are sorted by priority. fault recovery. All the settings on the device are made
When performing diagnostics on the The messages will be saved in the log using the navigation and function keys
PNOZmulti a location description is file. The saved data can be exported to or via the system software of the con-
also displayed. The location descrip- a CompactFlash card and then be nected device.
Connected
device CF-Card
PC
RS 232 RS 485 RS 232
5 or 6
1 2
PMImicro diag RS 232/RS 485
3 or 4 Converter
RS 485 RS 232
or
RS 232 RS 485
2
Wiring
To ensure trouble-free operation, ` The interference voltage from sup- current of 15 IN (15 x nominal cur-
please comply with the safety ply and signal lines and the electro- rent).
guidelines listed below. static voltages transferred by ` Please note during diagnostics on
contact are diverted via the earthing the PNOZmulti. The RS 232 inter-
` When choosing an installation site, point (ring lug, 4 mm thread or faces on the PNOZmulti and PMIm-
keep as large a distance as possi- press nut on the rear of the unit). icro diag do not have galvanic
ble between the system and any Connect this earth point to the pro- isolation. Any potential difference
electromagnetic fields. This applies tective earth PE via as short a cop- between the power supplies could
in particular when frequency con- per conductor as possible (cross- destroy the RS 232 interface. Con-
verters are nearby. section 2,5 mm2)! nect the PNOZmulti and PMImicro
` Inductive loads (e.g. contactors, re- ` Twisted pair, screened cable must diag to the same voltage source!
lay coils, and solenoid valve coils) be used to connect the interfaces.
within the environment, in particular ` Only use metal plugs or metallised
when they are fed from the same plastic plugs to connect the con-
supply voltage, must be wired with nection cables!
suppression elements (e.g. RC ele- ` We recommend you configure a
ments). safety screening on both sides for
` Power cables should be laid sepa- cable connections between two de-
rately to data line connections to vices.
avoid capacitive and inductive ` The power supply for the supply
transmission (recommended mini- voltage to the display system must
mum distance = 10 cm/3.94")! be designed for a peak switching
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
-2
Graphics Diagnostic Terminal
` Interfaces
+ 24 V
4: Termination RS 485
0V
1 2 3 4
` Interface configuration
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Graphics Diagnostic Terminal
` Termination
` Voltage supply
+ 24 V
0V
1 2
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
-4
Graphics Diagnostic Terminal
Dimensions
Installation
2.598"
3.071"
66
78
control cabinet, front panel, or con-
sole. The wall thickness should be
between 2.5 mm and 5 mm.
` To avoid the build-up of heat, a dis- 148 51
tance of 10 cm/3.94" should be 5.826" 2.008"
maintained all round the unit.
` IP65 protection can only be guaran- 135,8
teed when the fixing screws on the 5.354"
unit are firmly in place and the gas-
ket is not damaged.
0.28"
Notice Mounting cut-out 7,3
138 + 1
5.433"
Technical Details
Electrical data
Supply voltage 12 ... 32 VDC
Rated supply voltage 24 VDC
Power consumption 2.5 Watt
Display
Display type LC-DotMatrix Grafik-Modul
Resolution 128 x 64 Bit
Display range 60 x 40 mm (W x H)
Backlight White LEDs
Interfaces
Serial interfaces 1 x RS 232
1 x RS 485
Cable run RS 232: 10 m
RS 485: 1000 m, max. 110kBit/s
CompactFlash card slot 50-pin
Computer
Processor RISC processor
Operating system µClinux
Memory 8 MByte Flash
32 MByte SDRAM
Real-time clock Battery-buffered real-time clock
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany B&B-D-2-222-2006-06
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Graphics Diagnostic Terminal
Environmental data
EMC
Noise immunity EN 61000-6-2, 10/01
Noise emission EN 55022 Class A, 04/03
Protection type (EN 60529, 02/00) Front: IP65, back: IP20
Ambient temperature (EN 60068-2-14, 11/99) 0 °C ... +55 °C
Storage temperature (EN 60068-2-1/-2, 07/94) -25 °C ... +70 °C
Climatic suitability (EN 60068-2-78, 10/01) Max. 95 % r. F.; at 40 °C
Condensation Not permitted
Vibration in accordance with (EN 60068-2-6, 04/95)
Frequency 10 ... 150 Hz
Amplitude 1g constant
Shock (EN 60068-2-27, 03/93) 15g, 11 ms
Mechanical data
Housing material
housing Stainless steel
front ABS Polyflam, UL listed
Dimensions (with front) (H x W x D) 78 mm x 148 mm x 57 mm
Modular depth 51 mm
Weight 370 g