Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FCCU Feed Flexibility Project

CALCULTION OF BOTTOM PLATE THICKNESS for CLARIFIER

SPECIFIC GRAVITY OF Fluid = 1.154


Unsupported length of plate (Consevatively) = 275.9 cm
Maximum Allowable product
Design stress = 98.3 Mpa

Density of Fluid = 1154 kgf/cubic.m


design height of liquid = 5950 mm
pressure = 6866.3 kg/sq.m
0.06733 Mpa
AS per IS 803 - Snap shown below

Minimum Thickness of bottom plate in mm = 6.717579 mm

Provided Bottom Plate thickness is 10 mm