Medium Voltage Distribution

Take advantage of Find out more about our feeder automation solution, today!
Feeder Automation
Master the challenges of
today
and tomorrow
Visit www.schneider-electric.com/energy-automation to learn more
our Feeder Automation solution... about the Easergy range.
Panorama
from de-centralised to centralised architectures
As a distribution network operator, you know the challenges you
face today better than anyone. But what about the challenges of

De-centralised Semi-centralised Centralised tomorrow? Can you maintain your network and simultaneously:

(RTU) (SCADA/DMS + RTU) (SCADA/DMS) Evolve with the grid


New technologies are changing the grid itself. Are you prepared to
incorporate smart-grid technologies and manage smart metering
data? To integrate more renewables?
SCADA
DMS
SCADA
DMS Ensure availability
Demand for energy is growing. Will you be ready to manage it
on both MV & LV sides? To reduce outage durations (SAIDI) on
networks operating near capacity?

Maintain quality
Power and voltage quality are key. Do you have a plan to
Simple & fast delivery Combined management Common worldwide
regulate quality in the face of unbalanced loads and stricter
of priorities on targeted architecture
Quick hit for problematic CO2 emissions limits?
locations equiped with
locations Standardised field devices
reclosers, ATS, CBs on
Fastest restoration time Single solution for entire Manage costs
underground loop or self
healing loop grid None of the above matters if you can’t turn a profit. How can you
Fast return on investment
Advanced functionality reduce capital expenses, minimize the impact of equipment faults,
Long term global scheme
and cut technical losses?

ART.832397 © 2014 Schneider Electric Industries SAS - All rights reserved


from leading DMS

Reconfiguration time: <1 min Reconfiguration time: <3 min Reconfiguration time: <5 min Make the most of your energy tm There’s no magic answer to these challenges, but modernisation is
key. And by implementing effective network automation, you can
make it easier.
Our semi-centralised Our ADMS offer
Our Self Healing Grid
solution combines the provides the market’s
solution is based on
well known products
standardisation of a most advanced How?
conventional DMS with DMS solution for With flexible, reliable automation solutions to help you
which are customized
the flexibility of de-
with pre-defined
centralised solutions
your control centre, Schneider Electric Industries SAS
enhance grid reliability, optimize network
schemes for fast together with 35, rue Joseph Monier As standards, specifications and designs change from time
for truly powerful standard devices for
CS 30323 to time, please ask for confirmation of the information given
performance, and reduce outage durations. In any
project delivery and F - 92506 Rueil Malmaison Cedex (France) in this publication.
solutions with smart maximum efficiency.
Tel.: +33 (0) 1 41 29 70 00
distribution network.
flexibility. RCS Nanterre 954 503 439 Design: Schneider Electric Industries SAS
grid customisation. Capital social 896 313 776 € Photos: Schneider Electric Industries SAS - iStock This document has been
www.schneider-electric.com Printed: printed on recycled paper.

AMTED107018EN 02-2014
Feeder Automation solution Overhead Network Overhead Network Underground Network Underground Network

at a glance
Dedicated supervision for
Easergy range Recloser Remote Remote Local Fault Local Fault Remote Remote MV/LV Substation
Controler Network Control Network Monitoring Indication Indication Network Control Network Monitoring power supply

PE57924G

DM103099

DM103098
PM103550

PM103942

PM100592
PE90722

PM57922
PE57923

PE90724

PE57927

PE57929

PE57787

PE90717

PE90718
PE56266
Easergy ADVC 2 Easergy Easergy Easergy Easergy Easergy Flite 312, Easergy Flair 21D, Easergy Easergy Flair 510, Easergy Easergy Easergy Easergy Easergy
L500 T200 P Flite 116-SA/G200 Flite 110-SA Flite 210, 230 315, 332, 335, 382 22D, 23D, 23DM Flair 219, 279 570, 590 T200I T200E R200, ATS100 Flair 200C PS100
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Easergy range dedicated Dedicated controller for N, U, W Overhead switch control unit Communicating fault passage Fault current detectors Fault current detectors Fault current detectors Fault current detectors Control unit for MV and MV/LV substations Switch monitoring Communicating fault passage
remote control system reclosers, and RL sectionaliser indicator for overhead lines for an overhead network for an overhead network for an overhead network for MV substations and control unit indicator for MV substation

Capacity Phase and earth current, Control of 1 or 2 switches, Single-phase ammetric detector Single-phase ammetric Three-phase ammetric Three-phase directional Three-phase Three-phase ammetric Three-phase detectors Control of 1 to 16 switches, Control of 4 switches, 1 or 2 Fault Passage Indicators
400 Easergy type devices directional, voltage, frequency, PM6 or other load break switches detector detectors detectors amperematric/ammetric detectors compatible with all RM6, FBX, SM6 and other dedicated to Ringmaster functions, compatible with all
harmonics fault detectors with LCD. neutral system types cubicles earthing systems
Compatible with all types
of neutral system and
4 communication capability.

5 Main functions Main functions


DIN format

Main functions
 Network view with substation alarm  Phase and earth faults,  Pole-mounted Flite 116:  Line installation  Pole-mounted  Pole-mounted  Incorporated in the  Wall-mounted  Wall-mounted  Wall-mounted  Ringmaster-mounted  Wall-mounted
 Detailed substation view directional  Switch monitoring and control  clip-on installation switchgear  Phase-to-phase and
 Alarm logs, archives  Measurement : Current, voltage, 24VDC or 48VDC motorizations  Phase-to-phase and phase-to-  Phase-to-phase and  Phase-to-phase and  Phase-to-phase and  Phase-to-phase and  Phase-to-phase and phase-to-earth fault  Switch monitoring and control 24VDC or 48VDC  Control and monitoring  Phase-to-phase and phase-to- Power supply and battery
 Direct access to substation view real power, power factor, demand,  Fault passage detection earth fault current detection phase-to-earth fault phase-to-earth fault phase-to-earth fault phase-to-earth fault phase-to-earth fault current detection motorizations through embedded devices earth fault current detection charger for MV/LV
via a list harmonics, supply outages, phase-to-phase and phase-to-earth  I and U presence measurements current detection current detection current detection current detection current detection  Indication of transient  Fault passage detection phase-to-phase and in MV switchgear  U, I, P, Q, S, energy and substation.
 Automatic sorting of alarms waveform capture faults  Communication management  Indication of transient  Indication of transient  Transient and/or  Measurements: and permanent faults phase-to-earth faults Premset, SM6 (end 2014) power factor measurements 24V or 48V for motor and
and archives by substation  Setting: by laptop, operator  Automation systems: sectionaliser, with G200 and permanent faults and permanent faults permanent fault indicator  ammeter  Automation systems: sectionaliser, automatic power  Ensure remote cos  IEDs supply
 Online help control panel, Scada automatic power source transfer  Powered by lithium battery  Fault counter  maximeter source transfer control and automated  Management of 3 digital 12V for communication
 Installation: mounted on the  Measurements: I, U, P, Q, S,  Powered by lithium  Powered by lithium  Powered by lithium  Self-powered by  Power supply:  Power supply:  Measurements: I, U management. outputs and 6 digital inputs device supply
pole or substation frame energy and power factor cos  G200: battery battery battery, solar panels or current sensors and 3  Flair 279: 220 Vac  Flair 510: with Li battery  Embedded web server.  220 Vac supply backed-up by
 Concentration of Modbus slave  Pole-mounted 12 Vdc depending on backup supply solutions (battery-backed)  Flair 570: 110/220 VAC  Concentration of Modbus slave devices  Local and remote lead battery Autonomy up to 24h

2  Remote setting with WSOS5


monitoring and control software
devices
 Data and measurements archives
 Electronics sealed to IP65, 316  Back-up power supply for control
 Data concentrator up to 9 Flite
116-SA sensors
 Processing and archiving
model when network is dead:
 21D: super capacitor
 22D Li Battery
 Flair 219: battery with backup Li battery
 Flair 590: 220 VAC with
backup supercapacitor
 Data and measurements archives
 Back-up power supply for control unit, switch and
transmission equipment: typical autonomy 16 hours
configuration
 ATS100:
automatic source transfer
 Concentration of Modbus
communicating devices
 Data and measurement
90W for 24/48V permanent
load
grade stainless steel enclosure unit, switch and transmission  Free I/O: 3 digital outputs and  23D/23DM: Ext DV  Programmable logic controller IEC 61131-3 and built-in with dedicated front panel. archives
equipment: typical autonomy 16h 6 digital inputs supply calculation formulas to create or tailor specific functions/ Lines, generator,
3
 Programmable logic controller 300W 1mn for motor supply
 Programmable logic controller  220 Vac, solar or 12 Vdc supply applications bus tie IEC 61131-3 and built-in 10kV insulation
IEC 61131-3 and built-in calculation calculation formulas to create
formulas to create or tailor specific
Can be delivered or tailor specific functions/ Monitoring of battery to
Advanced controller dedicated functions/applications embedded in RM6, Embedded in SM6 Brain of Premset applications detect end of life through
to N, U and W Series reclosers, PM6 remote control enclosure FBX, Flusarc and cubicle NSM for ATS embedded control and Modbus communication
and RL Series sectionaliser Premset function (T200S) monitoring system

Communication Communication Communication


 Integrated communication front-end  Radio, modem, GSM, V23,  1 to 2 serial communication  915 MHz short range radio  Option: signalling  Signalling contacts  Signalling contact  Signalling contact for  Signalling contacts for  1 to 2 serial communication ports to SCADA/DMS  Radio, PSTN, GSM,  1 communication port
 Permanent and non permanent RS232, RS485, 10BaseT Ethernet ports to SCADA/DMS communication between G200 and contact for RTU for RTU for RTU RTU RTU (signalling possibility  1 Ethernet port GPRS, 3G  1 Ethernet port (option)
6 communications management:
 phone line/GSM/GRPS/3G
 1 Ethernet port
 Communication port operation
Flite 116-SA
 1 SCADA/DMS communication
 1 RS485
communication port
separate from phase and
neutral faults)
 Communication port operation management
 Transmission interface: PSTN, radio, GSM, GPRS,
 Transmission interface:
PSTN, Radio, GSM, GPRS,
 radio management port transmission interface: radio, (Flair 23DM only)  Two external inputs 3G, Ethernet, dedicated line, RS232, RS485 Ethernet, RS232, RS485
 direct public and dedicated private line  Transmission interface: PSTN, GSM, GPRS allowing:  Peer-to-peer communication in Modbus IP
to  Ethernet radio, GSM, GPRS,  resetting of faulty
7 8 15  Periodic call management 3G, Ethernet, dedicated line,
RS232, RS485
signalling
 detector tests
 Peer-to-peer communication in
Modbus IP

Communication protocol Communication protocol Communication protocol


 Modbus serial and TCP/IP,  DNP3, IEC 870-5-101/104  IEC 870-5-101 and  IEC 870-5-101  Modbus  IEC 870-5-101 and IEC 870-5-104  Modbus/IP,  IEC 870-5-101 and
IEC 870-5-101 and IEC 870-5-104 Modbus/IP and DNP3/IP IEC 870-5-104  Serial DNP3 and TCP/IP  Serial DNP3 and TCP/IP  IEC 870-5-101/104, IEC 870-5-104
 Serial DNP3 and TCP/IP  Serial Modbus and TCP/IP  Serial Modbus and TCP/IP  DNP3, DNP3/IP  Serial DNP3 and TCP/IP
 Serial Modbus and TCP/IP  Other proprietary protocols  Serial Modbus and TCP/IP

1 Configuration
 Other proprietary protocols

Configuration Configuration
 Professional communications and  Controls N, U and W series  Embedded web server  Local configuration with PC tool  By micro-switches  By micro-switches  Configurable via display  By micro switches or  By micro-switches  Configurable via display  Embedded web server  Embedded web server
database editor Reclosers and RL-Series Load  Local and remote configuration unit push buttons & LCD unit unit  Local and remote configuration  Local and remote configuration
 Data creation via dialogue boxes Break Switch/Sectionaliser

Accessories Accessories Accessories


 PSTN modem, GPRS/3G and fibre optic  TTS (Test & Training Set)  Simulation tools and tests  Installation tool  Open phase and zero  Open phase and zero  Open phase and zero  Open phase and zero  Open phase and zero  Fault indicator: Flair
modems  IOEX (Input Output Expander) sequence sensors sequence sensors sequence sensors sequence sensors sequence sensors 23DM
 FTIM (Fast Trip Input Module)  External Light Indicator*  External light indicator*  External light indicator*  Control unit: SC110
 SVIIS (Secondary Voltage  Unit for wall-mounting*  Backup power supply:
Injection Interface Set) *(optional) *(optional) *(optional) PS100