KV440C2 - Apm403 - en

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Model:KV440C2

380 – 415V Diesel

Standard Feature:
• KOHLER Co., provides one-source responsibility for the
generating system and accessories
Rating Range
• The generator set and it’s components are prototype-
KV440C2
50Hz tested, factory-built and production-tested

Standby kW 352 • One-year standard warranty covers all systems and


kVA 440 components
Prime kW 320 • Volvo engine
kVA 400 • Leroy Somer alternator
• 50℃ radiator
• Frame and vibration damper
• 470L Fuel tank
• Dry air cleaner
• DEC4000 controller
• Battery and battery cable
• Operation manual

Generator Rating
Standby Prime
Alternator V Phs Hz kW/kVA Amps kW/kVA Amps

220/380 3 50 352/440 669 320/400 608


LSA47.2 VS3 230/400 3 50 352/440 635 320/400 577
240/415 3 50 352/440 612 320/400 556

RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever

Preliminary Version
Alternator Specification
• IEC60034, NEMA MG1.22, ISO8528, CSA, UL,
ISO9001,ISO14001, CE standard Specification Alternator

• IP23 Manufacturer Leroy Somer


• Class H Insulation Type 4 Pole Rotating
• 2/3 winding pitch Excitation SHUNT
Specification 50Hz Leads 12 Leads
Voltage 400V Voltage regulator R250
Standby (27℃),kVA 440 Insulation: NEMA MG1
Prime (40℃), kVA 400 Material Class H
Efficiency (full load) 93.1% Coupling Single Bearing
3
Air Flow, 𝑚 /𝑚𝑖𝑛 54 Voltage regulation ±0.5%
Direct-axis (X’’d), % 15.5
Specification
Engine Engine Electrical
Engine Specification Engine Electrical
Manufacturer Volvo Battery Charging 24V
Engine Model TAD1344GE-B Ground/Negative Negative
Engine Type 4cycle,Turbocharge Voltage (DC) 24
Cylinder arrangement 6 in-line Starter motor rated voltage (DC) 24
3
Displacement, L (𝑖𝑛 ) 12.78 (779.9) Battery, recommended Ampere
Bore and Stoke, mm (in) 131 x 158 (5.16 x 6.22) Hour (CCA)
Compression ratio 18.1:1 QTY, CCA 2,1000
Piston speed, m/min (ft/min) 474 (1555) Battery Voltage (DC) 12
Rated speed (r/min) 1500
Max, power at rated rpm, kW (BHP) 399 (543) Fuel
Governor Type Electronic Fuel System
Frequency Regulation 0% Max. Fuel Flow, Lph (gph) 120 (31.7)
Air Cleaner Type Dry Fuel prime pump Manual
Exhaust Fuel Type Diesel
Exhaust System Fuel Tank Capacity, L (gal) 470 (124.2)
Exhaust manifold type Dry
3
Exhaust Flow, 𝑚 /𝑚𝑖𝑛 (cfm) 67.5 (2384) Lubrication
Exhaust Temperature, ℃ (℉) 465 (896) Lubrication System
Max allowable back pressure, kPa (in 10 (3) Type Full Pressure
Hg) Oil pan capacity with filter, L (qt) 30 (31.7)
Hook up, mm (in) 134 (5.3) Oil pan capacity initial filling, L (qt) 36 (38)

RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever

Preliminary Version
Specification Controller
Cooling
Radiator System
Radiator system capacity , L (gal) 44 (11.6)
Heat rejected to cooling water at rated, kW
155 (8815)
(Btu/min)
Water pump type Centrifugal The APM403 is a versatile control unit which allows
Fan loss, kW (HP) 10 (14) operation in manual or automatic mode
Max,restriction of cooling air, intake and ⚫ Measurements: voltage and current
NA
discharge of radiator, kPA (in 𝐻2 𝑂) ⚫ kW/kWh/kVA power meters
⚫ J1939 CAN ECU engine control
Air requirement ⚫ Alarms and faults: Oil pressure, Coolant temperature,
Radiator-cooled cooling air 𝑚3 /𝑚𝑖𝑛 (scfm) 402 (14196) ⚫ Overspeed, Start-up failure, alternator min/max,

Combustion air, 𝑚3 /𝑚𝑖𝑛 (𝑓𝑡 3 /𝑚𝑖𝑛) ⚫ Emergency stop button.


28 (989)
⚫ Engine parameters: Fuel level, hour counter
Air density =1.20 𝑘𝑔/𝑚3 (0.075 𝑙𝑏/𝑓𝑡 3 )
⚫ Mains and genset protection
⚫ Clock management
Fuel Consumption ⚫ USB connections, USB Host and PC,
Diesel, L/h (gal/h), load% Standby ⚫ Communications: RS485 INTERFACE
100% 91.5 (24.2) ⚫ ModBUS protocol /SNMP
Diesel, L/h (gal/h), load% Prime
100% 83 (21.9)
75% 63.3 (16.7)
50% 42.8 (11.3)

RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever

Preliminary Version
KOHLER CO., KOHLER Power Systems
Kohler, Wisconsin 53044 USA 400 1808 900
Phone +1 (920)-565-3381 Power@kohler.com
Kohler Power.com

Option

Canopy Others
• Canopy M229, 50Hz, 78 dB(A)@1m
• ________________________________
Standard
• Critical muffler, 40dB(A) • ________________________________
• Hospital muffler, 29dB(A) • ________________________________
• Connector, 40cm (16in)
• Bellow • ________________________________
• Protection Guard • ________________________________
• ________________________________
Cooling system
• Block heater (recommend to use when below 0℃ (32℉)
• Radiator protection cover Dimension and weight
Decision-Marker 4000 Controller Open Model
• Alternator protection
• Audible alarm module
• 5 expandable modules with 4 inputs/6 outputs
• Network modules (RTC and GSM modems and Ethernet
router)
• NFPA 100 module
• Remote annunciator Dimension, LxWxH mm: 3160 x 1805 x 1340
• Voltage/speed adjustment module Dry weight, kg: 3110
• Win Telys Software Wet weight,kg: 3570
Fuel system Canopy Model
• Automatic fuel tank fil kit
• Fuel tank with secondary containment basin
• Subbase fuel tank leak alarm
• Water separator fuel filter
Electrical System
• Battery charger, equalize/float type
• Battery isolator switch Dimension, LxWxH mm: 4475 x 2430 x 1410
Engine and alternator Dry weight, kg: 4080
• Alternator strip heater Wet weight,kg: 4170
• Air cleaner, heavy duty (with air restriction indicator)
• Droop kit with 3-function voltage regulator
• Electronic governor
• Lube oil drain pump
• PMG alternator and voltage regulator
• Tropical heavy-duty alternator insulation

RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever

Preliminary Version