Alpha Novus Outdoor FXM2000 For Broadband Operators - May2010
Alpha Novus Outdoor FXM2000 For Broadband Operators - May2010
By Charles Tsang
Sales Director, Asia Pacific
ctsang@alpha.com
Communications Capability
• External communications via RS-232 port or (optional) SNMP interface provides local or
remote monitoring and control with Windows based software
Generator Compatibility
• Works with Alpha DC Generator for extended backup. Alpha DC Generator runs off
Natural gas or LPG
More Comments on The
On-Line UPS System
Installed Site Conditions
• Most ACUPS installed sites are small and fully enclosed area with no air conditioning nor
ventilation with average running at above 35ºC even the outside ambient temperature is
around 25ºC
• Additional 255Watt heat load is generated by On-Line UPS to have further increased the
ambient temperature of the room
• Despite cooling fan on top of enclosure but heat flow can be blocked due to the large depth
of the rack mount On-Line UPS
• System degradation is accelerated for Indoor designed UPS while working at above 40ºC
• More temperature improvement can be achieved via the remote battery temperature sensor
of the FXM and one of its dry contact to control an enclosure fan to improve the airflow
increasing the reliability of the UPS and the batteries
• Alpha Novus FXM ACUPS are installed in the worldwide market for Telecom, security,
Traffic and Industrial Outdoor applications
• Design life of most battery is around six to ten years – based on 25°C
• High temperatures shorten battery life when used in Outdoor
uncontrolled environment – each 10°C rise will reduce battery life in half
• Valve-regulated, gelled-electrolyte are the safest, most cost-effective
battery type for Outdoor applications
• Alpha Premium Gel Battery is the Industrial proven GEL battery to last
the longest life despite working in high temperature environment
• A practical life expectancy of 5 – 8 years are obtainable in high
temperature environment (as compared to most AGM battery with much
lesser life) when use in Alpha UPS solution with Temperature
Compensated Charging technique
Temperature vs. Battery Life
80
60
40
20
0
0°C 20°C 40°C 60°C 80°C
Temperature (deg C)
Temperature Compensation
Charging
46 Vdc
44 Vdc
42 Vdc
FloatVoltage
40 Vdc
38 Vdc
36 Vdc
-20°C 0°C 30°C 50°C
Degrees C
AlphaCell Key Feature Summary
• GXL - Ultra low level of Calcium alloy reduces positive grid corrosion
• GXL - Ultra low level of Calcium alloy coupled with patented combination
of Silver and Tin grid chemistry provides ultimate protection against
corrosion and growth
Ethernet (optional)
Battery Voltage Test Points Input Circuit Breaker
Battery Circuit Breaker
RS-232 Port
Internal Fan
Input Output
48VDC battery connector Programmable Dry
Contacts
Specifications: FXM UPS Series
Power Module FXM 650 FXM 1100 FXM 2000
Nominal Voltage 120/230VAC 120/230VAC 120/230VAC
Nominal Frequency 60/50Hz 60/50Hz 60/50Hz
Input Current 8.7/4.5A 15.5/8A 20/12A
Output Power 650W/VA 1100W/VA 2000W/VA
Output Power @ 74°C 500W/VA 850W/VA 1500W/VA
Battery String Voltage 24/48VDC 48VDC 48VDC
Input Voltage Range (120VAC) 85 to 175 VAC without going to batteries
Input Voltage Range (230VAC) 150 to 328 VAC without going to batteries
Mechanical
Width (in/mm) 17/432 15.5/394 15.5/394
Height (in/mm) 3.5/89 (2RU) 5.2/133 (3RU) 5.2/133 (3RU)
Depth (in/mm) 9/229 8.75/222 8.75/222
Weight (lb/kg) 25/11 35/16 39/18
Novus FXM - Line Interactive UPS
Pure sine wave output
• Pure sine wave output at all times
• Provides voltage regulated, filtered AC supply to loads
• Typical transfer time to and from Batteries is <5ms (Note: 16.7ms/Cycle
at 60Hz)
• Automatic Voltage Regulator (AVR) – Double Buck/Double Boost
• Inverter operates when AC supply has failed; Below 85V & over 175 V
AC
• 48 VDC buss operation
Novus FXM - Protection
• Sizes 650, 1100 and 2000, Watts/VA
• Automatic Voltage Regulation (AVR)
• Emergency Power Off (EPO) input
• Load shedding via independently programmable timers (0 to 8hr @ 5
minute intervals)
• Temperature-compensated battery charging system (user adjustable to 3,
6 or 10A)
• Battery reverse polarity protection
• Variable fan speed with failure alarm
• Circuit breaker protection on the input and the external battery input
• Hot-swappable batteries to protect equipment
Novus FXM UPS Series - Convenience
• Operation and startup without the battery – Cold Start
• 48VDC output provided for external fan control
• Six sets of NO and NC user programmable relays for control and report
functions:
• Timer events, low battery, alarms, overloads, fault signals
• Generator compatible
• Three user inputs:
• Self test, alarm and shutdown
• Rotatable LCD Status Display and Control Panel
• Automatic restart of all connected equipment upon return of utility power
• Generator-ready for extended runtime option
Novus FXM- Manageability
• Remote monitor and control communication options:
• Standard RS-232 serial port or optional internal SNMP Ethernet
interface
• Optional Ethernet: the FXM Communication Module provides Web
interface for remote monitoring
• Load shedding via independently programmable timers
• (0 to 8hr @ 5 minute intervals)
• Multiple mounting configurations:
• wall, shelf or rack
• 100 historical events logged with time/date stamping
• Intelligent battery management
• Alarms to provide notification of changing utility and power
conditions
Novus FXM
Rotatable LCD Display: 2 x 20 backlit alpha-numeric LCD screen that
displays status, event, alarm, fault and control UPS functions locally.
Function keys:
Cancel
Battery Voltage Scroll
Test Point Select
LEDs:
Status
Alarm