Professional Documents
Culture Documents
Emerge™ Pc/Abs 7740: Technical Information
Emerge™ Pc/Abs 7740: Technical Information
Overview EMERGE PC/ABS Advanced Resin is an opaque, ignition resistant PC/ABS for extrusion
applications. It contains no chlorinated or brominated based additives and complies with DIN VDE
0472/Part 815 as Halogen Free. This resin combines easy process ability with ductility at low
temperature. EMERGE PC/ABS is certified UL94 V-0 at 1.5 mm and 5VA at 3.0mm
Flammability(3)
UL94 Classification at UL94
1.5 mm V0
2 mm 5VB
3 mm 5VA
Glow Wire Flammability Index – 1mm IEC 60695-2-12 960°C
Glow Wire Flammability Index – 2mm IEC 60695-2-12 960°C
Glow Wire Flammability Index – 3mm IEC 60695-2-12 960°C
Limiting Oxygen Index ISO 4589-2 32 %
Processing Conditions
Drying Temperature, 3 to 4 hours 80°C - 100°C
Notes 1. Typical properties; not to be construed as sales specifications. Fabrication conditions, part design, additives, processing
aids, finishing materials, and use conditions can all affect the integrity, performance, and regulatory status of finished
goods.
2. Tests conducted 4.0 mm injection molded specimen, unannealed, unless noted.
3 This rating not intended to reflect hazards presented by this or any other material under actual fire conditions.
Customer Trinseo strongly encourages its customers to review both their manufacturing processes and their applications of
Trinseo products from the standpoint of human health and environmental quality to ensure that Trinseo products are not
Notice used in ways for which they are not intended or tested. Trinseo personnel are available to answer your questions and to
provide reasonable technical support. Trinseo product literature, including safety data sheets, should be consulted prior
to use of Trinseo products. Current safety data sheets are available from Trinseo.
Medical NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: Trinseo will not knowingly sell or sample any product or
service (“Product”) into any commercial or developmental application that is intended for:
Applications Policy a. long-term or permanent contact with internal bodily fluids or tissues. “Long-term” is contact which exceeds 72 continuous
hours;
b. use in cardiac prosthetic devices regardless of the length of time involved (“cardiac prosthetic devices” include, but are not
limited to, pacemaker leads and devices, artificial hearts, heart valves, intra-aortic balloons and control systems, and
ventricular bypass-assisted devices);
c. use as a critical component in medical devices that support or sustain human life; or
d. use specifically by pregnant women or in applications designed specifically to promote or interfere with human reproduction.
Trinseo requests that customers considering use of Trinseo products in medical applications notify Trinseo so that appropriate
assessments may be conducted.
Trinseo does not endorse or claim suitability of its products for specific medical applications. It is the responsibility of the
medical device or pharmaceutical manufacturer to determine that the Trinseo product is safe, lawful, and technically suitable for
the intended use. TRINSEO MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE
SUITABILITY OF ANY TRINSEO PRODUCT FOR USE IN MEDICAL APPLICATIONS.
Disclaimer NOTICE: No freedom from infringement of any patent owned by Trinseo or others is to be inferred. Because use
conditions and applicable laws may differ from one location to another and may change with time, the Customer is
responsible for determining whether products and the information in this document are appropriate for the Customer’s
use and for ensuring that the Customer’s workplace and disposal practices are in compliance with applicable laws
and other governmental enactments. Trinseo assumes no obligation or liability for the information in this document.
NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
NOTICE: If products are described as “experimental” or “developmental”: (1) product specifications may not be fully
determined; (2) analysis of hazards and caution in handling and use are required; (3) there is greater potential for
Trinseo to change specifications and/or discontinue production; and (4) although Trinseo may from time to time provide
samples of such products, Trinseo is not obligated to supply or otherwise commercialize such products for any use or
application whatsoever.
Responsible Care® Our top priority is to provide the highest quality products and services, and to focus on the American Chemistry
Council’s Responsible Care® initiative and safety in all of our facilities.