Download as pdf or txt
Download as pdf or txt
You are on page 1of 55

MEDICAL DEVICE & FACILITY

VISION
A company providing best quality, trusted and reliable medical devices and facilities by prioritizing excellent
services with high dedication.

MISSION
Giving the best solution in providing the top quality medical devices and facilities
PRODUCT
PRODUCT
Ongoing Projects of
Medical Facilities and Devices
CRITICAL
ENVIRONMENT
CONTROL
DESIGN
In application of
MEDICAL FACILITY
Scope of Services

• Design, construct and maintain buildings or facilities by controlled


environment.
• Controlled parameters include: Temperature, Humidity, Pressure,
Cleanliness, etc.
Application
• Biosafety Level Laboratory (BSL2/3)
• Isolation room (- / +)
• Intensive Care Unit (ICU) room
• Clean room facility (GMP)
FOCUS BSL
BIOSAFETY LEVEL
WHO Define

“Laboratory biosafety describes the containment principles,


technologies and practices that are implemented to prevent the
unintentional exposure to pathogens and toxins, or their accidental
release to workers, surrounding people and environment.”
BSL Keywords

The implementation of correct bio risk management in the laboratory aims


to reduce the risk of harm to workers, surrounding people, the
environment and it’s community and also to secure sample material
BSL Combine of

1. Guideline & SOP


2. Facility
3. Maintenance
Guideline

BSL is intended for Labs that are related and bound by


regulations, such as WHO, Minister of Health
Regulation, etc.
Biosafety Manual,
rd
3 edition

WHO
Biosafety in
Microbiological
and Biomedical
Laboratories BMBL
5th Edition
th
5 edition

CDC
U.S. Department of Health and Human Services
Public Health Service
Centers for Disease Control and Prevention
National Institutes of Health

HHS Publication No. (CDC) 21-1112


Revised December 2009
Design
Requirements
Manual

NIH, 2016
Standar
Pelayanan Lab TB
2015

KEMENKES
ISBN : 978-602-235-692-9

PEDOMAN TEKNIS
Pedoman Teknis BANGUNAN DAN PRASARANA
FASILITAS PELAYANAN KESEHATAN TINGKAT PERTAMA
UNTUK MENCEGAH INFEKSI YANG DITRANSMISIKAN

Fasilitas Airborne MELALUI UDARA (A


IRBORNE INFECTION)

Infection

KEMENKES 2014

KEMENTERIAN KESEHATAN RI
EDISI PERTAMA
SEPTEMBER 2014
BSL Design

• Lab-in lab
• Isolated BSL Lab
• Prefabricated BSL lab
• Mobile BSL (Lab on the wheel)
BSL Simple Level

• BSL 1 : Minimal potential hazard


• BSL 2 : Non-life-threatening; spread through contact, ingestions, inhalation or inoculation
• BSL 3 : Serious and possibly lethal disease through contact or aerosol transmission
• BSL 4 : High risk agents of life-threatening disease; vaccine or treatments has not been found and unknown
risk of transmission
BUILD the BSL

Plan & Requirement Test


Prepare & Design
Logistics Build
& Go -Live

Design & Engineering Team

Engineering & Site Team


> Requirement > Material Handling

Logistics Team

Commissioning Team
SALES

>Visit Project
Charter/ Customers Analysis >Prefabrication at > Create
> Inventory Indotech workshop Standard Test
>Project Planning >Project Blueprint
cases.
>Identify End user >Standardize Master >On-Site
requirements Data assembling > Performance
>Identify Process >Functional and Testing – Onsite
standardization Technical >On-Site
Needs Specifications Fabrication > User
>Assess Hardware Acceptance
requirements Testing
The Qualified BSL

• Design and Built with compliance to International BSL Standards


• To safeguard Principal Standards, Norms & Environment Regulations
• Ensure their compliances by the Occupier & the Operator.
• Environment and its Protection
Cascade Pressurization Concept
To create
Airflow Direction
BSL validation

• General validation of design and construction


• HEPA filter leak test
• Room differentials pressure test verification
• Particle test for cleanliness
• Light intensity test
• Air Velocity Test
Some Test Instruments

Anemometer Luminometer

Particle Arithmometer Balometer


Concept of Pre-Fabricated BSL2+

• Easy and Fast in terms of construction


• Moveable and installable in several location
• Independent lab: Simple maintenance; applying isolated principles to
infectious lab
• BSL2+ can provide the needs of a wider application
• Implements the concept of WHO and Ministry of Health standard
BSL2+ Preview
• 2 Container 40Feet High Cube
Architecture • Galvanize Canopy
• Preconstruction Base
• Dual Exhaust, as WHO mention on redundancy system
Mechanical
• HEPA Filter 99,99% effectiveness (0,3um) with BIBO
Ventilation system
Emergency
Exit
Extraction Room PCR Room

Vestibule Anteroom 1 Anteroom 2


Cascade Pressure

• Yellow Zone : +5
• Orange Zone : -5
• Red Zone : -15
• Green : Black area
• RFID Access (Restricted)
Front View • Magnehelic Pressure Monitoring
• BSL2+ Label
Vestibule
• Positive +5 Pressurization
• Drives away impurities from outside the
lab
• Using Lab Shoes
• Temporary sample storage
• Passbox, directed to extraction room
• CCTV monitoring
Anteroom 1

• Access to extraction room


• Showering at exit
• APD Donning/Doffing
• Negative -5 pressurization
• All Interlock door
Anteroom 2

• Access to PCR room


• IR Sensor Sink
• APD Donning/Doffing
• Negative -5 pressurization
• All Interlock door
PCR room

• PCR Cabinet equipped


• Transfer box to Extraction room
• Negative -15 Pressurization
• Intercom
• All curving corner structure
• Accomocdates 2 BSC level II A2
Extraction room • Phenolic resin working table, chemical resistant
• Pressure Alarm, fire alarm
Extraction Room

• Negative -15 pressurization


• Canopy hood to autoclave
• Medical waste transfer box (interlock)
• Eye shower and Sink (as WHO mandatory)
Emergency Exit

• Application of safety principles


• Access through the space
between negative pressures
• Waste Passbox are accessed
more securely
STANDARD
EQUIPMENT
PACKAGE
PCRMAX ECO48, Real Time PCR
Key Features
• MIQE compliant.
• HRM functionality is provided as standard and can discriminate class IV SNP 99.9% of the time.
• The Eco 48 can utilise four colours for easy multiplexing.
• Industry leading ±0.1ºC temperature uniformity (recorded at 95ºC no settle time).
• Suitable for both single labs and core facilities.
• High uniformity provides high quality data.
• Fast cycling enables several experiments per day, all at an economical price.
• Fastest block-based real-time PCR system with the ability to run 40 cycles in 20 minutes (or less when
optimised).
• The PCRmax Eco 48 is an open platform that can utilise any chemistry, dye or PCR reagent.
• Calibrated for SYBR®, FAMTM, HEXTM, VICTM, ROXTM and Cy®5 fluorescent dyes.
• Easy to use software, streamlined for novices and experts.
• No need to run triplicates, to compensate for poor thermal uniformity of block.
• The Eco 48 format provides a small 34.5cm x 31cm (13.6” × 12.2”) footprint that fits anywhere.
VELP, Vortex Mixer

GENERAL FEATURES
Construction material: zinc alloy and technopolymer
Support system: 4 anti-sliding feet
Orbital diameter: 4.5 mm
Speed setting: analog
Speed control: electronic
Speed: up to 3000 rpm
Operating modes: touch, continuous
Electronic protection degree CEI EN 60529: IP 42
Power: 15 W
Weight: 2.7 Kg (5.9 lb)
Dimensions (WxHxD): 150x130x165 mm (5.9x5.1x6.5 in)
DLAB
Micropipette

Micropipette 10-100 uL Micropipette 2-20 uL Micropipette 0,1-2,5 uL Micropipette 100-1000 uL


HITACHI, MICRO CENTRIFUGE
CT15RE TABLE-TOP CENTRIFUGES,
T15A62 ROTORS
Max.:15K(rpm),21.5K(xg),2(ml)x24(pcs.),0.5(ml)x24(pcs.)
Maximum speed (rpm) 15000
Maximum RCF (x g) 21500
Maximum capacity 2 ml x 24 or 0.5 ml x 24 (When using the T15A62 angle rotor)
Speed control range (rpm) 300 to 15,000 (in increments of 100)
Temperature range adjustment -20 (displayed "Lo") to +40 (°C)
Timer 1 to 99 minutes. (in increments of 1 minute.)
with a HOLD function (continuous operation)
Acceleration/deceleration time variable 2-stage variable acceleration, 2-stage braked deceleration plus coasting deceleration
Drive motor Brushless DC motor (inverter control)
Memory-based programmed operation SPEED/RCF, TIME, TEMP (CT15RE only), ACCEL, DECEL and stop melody
Rotor stop signal Selectable from 5 types of stop melodies, beep and mute
Safety devices Door interlock, dual overspeed detector, imbalance detector, abnormal motor temperature
detector, etc
Compliance with standards CE marking (EN61326, 61010-1, 61010-2-020)
Heat radiation 500 W
AC220/230V ± 10% 50Hz 10A
AC220V ± 10%, 60Hz10A
Dimensions 290 (W) x 520 (D) x 300 (H)
Weight 40
DLAB D1008
Mini Centrifuge
• Ideal for microfiltration and quick spin-downs
• Easy-to-use with dual start/stop function
• 7000rpm fixed speed(D1008)
• 5000rpm fixed speed(D1008E)
• Compatible with 2mLx8 and PCR8x2 rotors
• Quiet running, noise level =45dB
• Rotor change without tools
• Accelerates and brakes in seconds
• Available in two colors i.e., green, blue
Specifications D1008
Max. Speed 7000rpm
Max. RCF 2680×g
Rotor Capacity 0.2mL×16 PCR strips or 0.2mL×2 PCR 8 strips0.2/0.5/1.5/2.0mL×8;
Run Time Continuous operation
Driving Motor DC motor
Power AC110-240V/50Hz/60Hz 20W
Noise Level =45dB
Dimension [D×W×H] 160x170x122mm
Weight 0.5kg
Certification CE cTÜVus FCC MCA
JENWAY, 7415 Nano
Spectrophotometer Nano,
• 7" High Definition colour touchscreen display
• Android operating system
• Features CPLive®
• Ideal for DNA, RNA and Protein measurements
• Only 0.5µl sample volume required
• Purity scan over entire wavelength range, 198 to 1000nm
• Quick and easy to clean
• Detects DNA concentrations as low as 2ng/µl
• Multiple USB ports for data storage and printer connectivity
• Multi-language options including English, French, German, Spanish and Italian
• Internal memory for methods and results (10GB onboard storage)
Outputs USB Type A x 2, USB Type B x 1, Ethernet connection (RJ45)
Supply VoltageFrequency 100 - 240VAC at 50 to 60Hz
Power Supply 24V DC, 2.5A
Dimensions (w x d x h) 280 x 500 x 156mm
Weight 9kg
Haier, DW-40W100
Deep Freezer -20 sd -40,
Product -40℃ Deep Freezer
Cabinet Type Chest
Climate Class N
Cooling Type Direct cooling
Defrost Mode Manual
Refrigerant CFC-Free
Cooling performance(℃) -40
Temperature Range(℃) -20~-40
Controller Microprocessor
Display LED
Power Supply(V/Hz) 220-240/50 115/60
Power(W) 255
Electrical Current(A) 5
Capacity(L/Cu.Ft) 100/3.5
Net/Gross Weight(approx) 43/46(kg) 94.8/101.4(lbs)
Interior Dimensions(W*D*H) 500*385*625(mm) 19.7*15.2*24.6(in)
Exterior Dimensions(W*D*H) 680*600*805(mm) 26.8*23.6*31.7(in)
Packing Dimensions(W*D*H) 740*650*880(mm) 29.1*25.6*34.6(in)
Container load (20'/40'/40'H) 54/108/162
High/Low Temperature Y
Haier, DW-86L338J
ULT Freezer -86
Product -86℃ ULT Freeer
Cabinet Type Upright
Climate Class N
Cooling Type Direct cooling
Defrost Mode Manual
Refrigerant HC
Noise Level (db) 50
Cooling performance(℃) -86
Temperature Range(℃) -40~-86
Controller Microprocessor
Display LED
Power Supply(V/Hz) 220-240/50
Power(W) 900
Electrical Current(A) 0.295138889
Capacity(L/Cu.Ft) 338/11.9
Net/Gross Weight(approx) 238/278(kg) 524.7/612.9(lbs)
Interior Dimensions(W*D*H) 465*630*1165 18.3*24.8*45.9
Exterior Dimensions(W*D*H) 812*893*1846 32.0*35.2*72.7
Packing Dimensions(W*D*H) 875*970*2010 34.4*38.2*79.1
Container load (20'/40'/40'H) 12/24/24
NU-437-600S
Class II Type A2 Biological Safety Cabinet, Voltage 230V/50Hz, Size: 6ft
Base Stand Options, With 4" Stainless Steel Castors, 6 ft., 30".
NUAIRE
Ultraviolet Light - 230V/50Hz, Size: 6 ft.

Performance Specifications NSF/ANSI 49 EN12469


Biosafety Cabinet
Class
Style of Cabinet
Class II
Bench top/console
w/base stand/storage cabinet
Class II, Type A2
Cabinet Construction All welded stainless steel 16GA, Type 304 pressure tight design
Diffuser for Air Supply (Metal) Non‐flammable
HEPA Filter Seal Type: HEPEX Seal
Supply Filter‐99.99% Eff. on 0.3microns Exhaust Neoprene,
Filter‐99.99%
Spring
Eff. loaded
on 0.3microns
Fumigation per EN 12469, Annex J Yes
Standard Services: One, Right Sidewall One, Right Sidewall Two, Backwall
Service Coupling (3/8 inch NPT)
Gas Valve/Service Coupling(3/8 inch NPT) Outlet
Optional Services: Up to 3 ea. Sidewall One, Backwall
Gas Valve/Service Coupling(3/8 inch NPT) Ultraviolet Light
Left or Right Work Surface
Standard/Cup Sinks
Cabinet Size Inches (mm): Height (Fully Assembled)
63 (1600)
Height (Minimum for Transport) Width 60 (1524)
Depth (with Control Center) 77 5/8 (1972)
32 7/8 (835)
Work Access Opening Inches (mm): Standard Opening
8 (203)Height/Optional
Standard Inflow Velocity 105 FPM/.53 m/s
Work Zone Inches (mm): Height 28 1/2 (724)
Width 70 3/8 (1788)
Depth 23 1/2 (597)
Viewing Window: Fully closed to
Standard is tempered sliding glass 19 1/2 inches (495mm) open
Required Exhaust CFM/CMH 410/697
Gas‐Tight (NU‐916/919) Thimble (NU‐918/917) Thimble
545/925(NU‐916)
606/1030
Plant Duct Static Pressure Eng/Metric 0.05‐0.1"/1.27‐ 2.54mm H2O
Heat Rejected BTU Per Hour 2435
(non‐vented) (vented) 1460
Hirayama, HVE50
Autoclave, 50 L

Model HVE-50
Effective capacity 50L
Chamber size (f x H mm) 300 x 710
Operation mode 3 modes (LIQUID with warming, LIQUID without warming, SOLID)
Temperature 105 - 135? Variable
setting range Sterilization
Warming 45 - 80? Variable
Lid lock 97?, fixed
Time setting 1-250 min, Remaining time is displayed
range Sterilization
Warming 20 hours, fixed
Air removal 4 min, fixed
Exhaust setting 3 levels (Natural cooling, Pulse cooling, Forced cooling)
Maximum working pressure 0.255MPa
Thermometer Digital display5~137?
Pressure gauge Digital display 0~0.3MPa / Analog display 0~0.4MPa
Safety devices Pressure safety valve, Over-current and earth leakage breaker, Low water cut off device
Alarms, error display Low water heating, Temperature sensor wire disconnection, Over-temperature, Over-cool, Over-pressure,
Abnormality in lid opening/closing lever lock
Outside dimensions (W x D x H mm) 547 x 532 x 1046
Weight (Approximately) 57 kg
Pressure vessel category Small sized pressure vessel
Chamber material Stainless steel (SUS304)
Power supply AC 110V / 120V / 220V / 230V / 240V, 50/60Hz,
(Specify voltage when ordering)
Required power supply facility 2.0kW
DLAB HM100PRO
Thermal Shaker

• Excellent mixing result


• Stable and wide range of speed adjustment
• Precise temperature control for heating
• Flexible adapter selection
• Programmable
• Compatible with various tubes
• Quick interchange of blocks with magnet adhesion technology and without any tools
• Block equipped with a lid for heat preservation
Specifications HM100-Pro
Functions Heating& mixing
Temperature range Heating: room temp. - 100 °C
Temperature setting range 15-100?
Temperature control accuracy ± 0.5°C
Temperature uniformity Max.± 0.5°C
Max. heating rate 5.5°C/min
Mixing frequency 200-1500rpm
Mixing orbit 3mm
Screen TFT
Program 9
Overheating protection 150°C
Adapter block material aluminum
Voltage, Frequency 100–240V,50/60Hz
Power 200W
Dimension [D×W×H]
( without the heating block ) 200×235×120mm
Weight 7.3kg
Genolution Nextractor NX48S
Other features

• WHO standard SOP & Certification Ready


• IOT + Android combine monitoring
• Wall & Ceiling: EPS Sandwich panel, fire retardant
• All curving corner
• Floor : PVC Vinyl flooring
• All curving corner
• Redundancy System : Back-up ventilation, UPS, Genset
• Alarming : Pressure, Fire
• Training SOP BSL bases on WHO standard & certification for 3 person
Thank You
For further Information, kindly contact us at:
gbn@glorybuminusantara.com

or visit us:
Jl Wibawa Mukti Raya No 5, Jatiasih, Bekasi

You might also like