Professional Documents
Culture Documents
05.1 - Electrical Drawing - 25158-Cf
05.1 - Electrical Drawing - 25158-Cf
05.1 - Electrical Drawing - 25158-Cf
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:52 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO DRAWING INDEX
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B 25158-CF-000
M.SMITH JAN. 2015
PX-CF-13
ELEVATOR DISCHARGE
EXIT JAM SENSOR
PX-CF-15
ELEVATOR DISCHARGE
EXIT JAM SENSOR
PX-CF-14A
PX-CF-14B
PX-CF-14C
TABLERO PNEUMATICO
PNEUMATIC ENCLOSURE
SV-CF-10 SV-CF-15A
SV-CF-11 SV-CF-15B
18 ft
PS-CF-10
BLUE
GREEN
YELLOW
RED
DS-CF-10
PX-CF-12
HOPPER JAM DETECTION
PX-CF-22 EMITTER
PX-CF-11
HOPPER JAM
SENSOR
NOTE: CROWN FEEDER MECHANICAL DRAWING REPRESENTED HERE IS USED ONLY FOR
ELECTRICAL LAYOUT REASON AND MAY NOT BE REPRESENTATIVE FOR ANY OTHER PURPOSE.
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO MECHANICAL
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description Rev.
1
Date Name/Nom Revision Description Rev.
LINE 7B LAYOUT 25158-CF-001
M.SMITH JAN. 2015
VFD PARAMETERS / DANFOSS VLT MICRO
PARAM. # PARAMETER NAME & DESCRIPTION FACTORY VALUE SIDEL VALUE UNIT
THE SPEED OF THE CAP FEEDER CAN BE CHANGED BY MODIFYING 0-10 ACTIVE SETUP (MULTI-SETUP) 1 1 -
THE CORRECT PRESET SPEED ON THE VFD ITSELF.
1-20 MOTOR POWER 0.75 0.55 kW
PLEASE FOLLOW THE FOLLOWING PROCEDURE TO ACCESS THE PRESET 1-22 MOTOR VOLTAGE 400 SEE ON THE MOTOR V
SPEED PARAMETERS.
1-23 MOTOR FREQUENCY 50 SEE ON THE MOTOR HZ
1. FROM THE VFD MAIN SCREEN, PRESS "MENU" TWO (2) TIMES. THE VFD'S
DISPLAY WILL SHOW THE FIRST PARAMETER ("0- ") 1-24 MOTOR CURRENT 2.1 SEE ON THE MOTOR A
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:52 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO VFD SETTING
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B 25158-CF-005
M.SMITH JAN. 2015
CF-CP
MANUFACTURING DATE :
30'' SERIAL :
UL LISTED : CF-993083
VOLTAGE :
FULL LOAD AMP :
2''
S.C.C.R. : 42000 A RMS @ 440 VAC
1 43 37 35
36 33
34 36 32
5''
CP-CF
DISC-CP-1
32 30
5''
ALLEN-BRADLEY
AB
MAIN DISCONNECT
FINAL POSITION TO BE
38 31
1''
DETERMINED BY PANEL
BUILDER. 32 43
1''
5'' 35 1''
32
R AD A
68
35
PA
DE
1''
IA
M
E
32
ER
43
C
GEN
PL-CP-1
VOLTAJE
DE CONTROL
61
CLEAR
8''
MODO MAQUINA REINICIO FORZAR
PARAR FALLA AIRE & MOTOR
ARRANQUE LIMPIEZA
137
32
30''
RED BLUE
35 SS-CP-1
CUTOUT
PUERTA DE ATASCO
35 CERRADA ABIERTA
43
1''
32
5'' 5''
13''
1''
52
43 35 32 44 39 32 35 43 NEED TO CUT BACKPLATE
FOR DRIP PAN INSTALLATION
13
8''
STACK LIGHT TO BE MOUNTED ON THE ELECTRICAL
ENCLOSURE SUPPORT.
28
BLUE
GREEN
8''
YELLOW
RED
1''
22 29
1''
22
7 ''
1''
22
8
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO ENCLOSURE
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B LAYOUT 25158-CF-010
M.SMITH JAN. 2015
CF-CP
3 ''
2816
11''
1816
6 7 8 9
42 41 51 52 53 54 55 56 57 58
CUT HERE
AND REMOVE
2
SPRECHER & SCHUH
SIEMENS
SF SF
SP.L11-J30 SF
4
RUN
STOP BF-PN
P1 P2 P3
8''
X1 MRES
PROFINET
MT
107
ON
DISC-CP-1
5
FRCE
SP.L11-J30-1753 RUN
1 STOP
4JA00-0AA0
2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6
6ES7 193
P1 P2 P3 6ES7 138 6ES7 131 6ES7 131 6ES7 131 6ES7 131 6ES7 131 6ES7 131 6ES7 132 6ES7 138 6ES7 132 6ES7 132 6ES7 132 6ES7 132 6ES7 132
4CA01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4CA01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0
LINK
X1 AUX1 AUX1
1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5
DC24V A A A A
4 8 4 8
2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6
3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7
A A 4 8 4 8 4 8 4 8 4 8 4 8 4 8 A A 4 8 4 8 4 8 4 8 4 8
4 8 4 8
A A A A A A A A A A A A A A A A A A A A A A A A
4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8
PDB-CP-1 A
3
A
7
A
3
A
7
A
3
A
7
A
3
A
7
A
3
A
7
A
3
A
7
A
3
A
7
A
3
A
7
A
3
A A
7 3
A
7
A
3
A
7
A
3
A
7
1492-PDM3141
1X3'' LOW VOLTAGE
19
16 MSR-046-01
CB-042-06
CB-042-04
CB-042-08
CB-042-10
CB-042-02
3 ''
030-06-COM
030-06-COM
030-06-COM
030-06-COM
030-06-COM
030-06-COM
2816
042-04
S11-D
S11-D
S21-D
S11-A
S11-C
S21-A
S21-C
S11-B
S21-B
S11-E
8''
MURR
HL24
73
26
59 60
VFD-CP-1
13 14 15 21
FRAME M1
8''
57
GND-CP-1
#8 AWG
1X3'' HIGH VOLTAGE TO DOOR
#10 AWG
ENCLOSURE
CUT HERE
AND REMOVE
11 12
24 25
10 10 3
187
8''
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO BACKPLATE
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description Rev.
1
Date Name/Nom Revision Description Rev.
LINE 7B LAYOUT 25158-CF-011
M.SMITH JAN. 2015
ITEM QTY MANUFACTURER CATALOG NO. DESCRIPTION SUPPLY ITEM QTY MANUFACTURER CATALOG NO. DESCRIPTION SUPPLY
1 1 HAMMOND EN4SD30308SS Type 4X Stainless Steel Enclosure 30"x30"x8" Panel Builder 51 6 SIEMENS 6ES7131-4BD01-0AA0 ET 200S 4 Digital Inputs Module DC24V GEBO
2 1 HAMMOND EP3030 Mounting Panel for 30x30 Panel Builder 52 12 SIEMENS 6ES7193-4CA50-0AA0 SIMATIC DP UNIVERSAL TERMINAL,FOR ELECTRONIC MODULE ET200S GEBO
3 1 ILSCO N-8020 Grounding Bar Panel Builder 53 6 SIEMENS 6ES7132-4BD02-0AA0 ET 200S 4 Digital Outputs Module DC24V GEBO
4 A/R 35mm DIN mounting rail Panel Builder 54 1 SIEMENS 6ES7151-8AB01-0AB0 Interface module IM151-8 Basic for ET200S, Ethernet GEBO
5 A/R PANDUIT Narrow Slot Gray Wiring Duct, size on drawing Panel Builder 55 1 SIEMENS 6ES7953-8LG20-0AA0 ET-200S, MICRO MEMORY CARD 128 KB GEBO
6 1 SPRECHER & SCHUH L11-J30-1753 FUSE DISCONNECT SWITCH 3 POLE CLASS J Panel Builder 56 2 SIEMENS 6ES7138-4CA01-0AA0 SIMATIC ET 200S POWER MODULE 24VDC GEBO
7 1 SPRECHER & SCHUH L11-PB OPERATING HANDLE Panel Builder 57 2 SIEMENS 6ES7193-4CD30-0AA0 SIMATIC DP TERMINAL MODULE FOR PM-E ET200S GEBO
8 1 SPRECHER & SCHUH L11-S1 OPERATING HANDLE SHAFT EXTENSION Panel Builder 58 1 SIEMENS 6ES7193-4JA00-0AA0 SIMATIC DP TERMINATING MODULE,FOR ET200S GEBO
9 3 MERSEN AJT30 30A TIME DELAY, CLASS J FUSE Panel Builder 59 1 DANFOSS 132F0018 VLT MICRODRIVE FC51 Adjustable Frequency AC Drive, 380-480VAC/3PH, 2.2A(1HP) GEBO
10 3 ALLEN-BRADLEY 1492-FB3C30 30A, 3P Class CC Fuse Holder Panel Builder 60 1 DANFOSS 132B0101 VLT Control Panel LCP 12 with potentiometer, for VLT Micro Drive FC 51 GEBO
11 6 MERSEN ATDR10 10A, Class CC Fuse Panel Builder 61 1 HOFFMAN TE162024011 ENCLOSURE COOLING 682 BTU/HR. 24VDC GEBO
16 A/R ALLEN-BRADLEY 1492-J4 One Level Feed-through Terminal Block (Complete with Accessories) Panel Builder
25 1 SPRECHER & SCHUH CA7-23E-10-24E 23A Contactor, 24Vdc Coil Panel Builder
28 1 BANNER TL50BGYRQ STACK LIGHT 4 LED 24VDC (RED, YELLOW, GREEN, BLUE) Panel Builder
29 5 HOFFMAN AS050SS HOLE TITE SEALS, STAINLESS STEEL FOR 1/2" HOLES Panel Builder
42 1 ALLEN-BRADLEY 1492-PBC9 Cover for 4 Pole Load Power Distribution Block Panel Builder
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:52 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO BILL OF MATERIAL
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B 25158-CF-012
M.SMITH JAN. 2015
POWER SUPPLY: 440 VAC 50HZ
IFLA : 7.8 A
CF-CP
LARGEST MOTOR: 2 HP GROUND FROM
MAIN FUSE : 30A CLASS J BUILDING STEEL
SCCR:42 KA STRUCTURE OR FROM PDP
FEEDER GROUND
1 21 PDB-030-04
DISC-030-02 FROM LINE 20
30A #10AWG #12AWG #12AWG #12AWG ENCL-CF-3
FU-030-02 CB-CF-3
FER.AJT30 FU-CP-3 C-CP-3
030-22-1 030-22-2 L1
2 #10AWG GROUND BAR 22
L1, L2. L3 : BLACK FER.ATDR-20
M-CF-3
030-23-1 030-23-2 L2
23 AIR CONVEYOR #1
030-02C
030-02A
030-02B
2HP / 2.5A
030-24-1 030-24-2
4 24 L3
4A
PDB-030-04 POWER SUCPLY
FU-030-05 PWS-030-05
030-05 030-05-24V
5 L1 +24V 24VDC TO [042-01] 25
FER.ATQR-10 PL-030-05
WH
#10AWG
M-CF-4
L2
8 28 AIR CONVEYOR #2
#10AWG #14AWG #14AWG 2HP / 2.5A
DISC. SWITCH
FU-CP-1 VFD-CP-1 C-CP-1
030-09-1 030-09-2 030-09-3 L1
9 L1 U 29 L3
FER.ATDR-10 4A
DANFOSS
VLT MICRODRIVE M-CF-1
030-10-1 FC51 030-10-2 030-10-3 L2
10 L2 V ELEVATING BELT 1 30
1HP / 1.5A
12 32
13 33
14 34
15 35
16 36
17 37
18 38
19 39
20 40
TO LINE 21
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:52 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO POWER DISTRIBUTION
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B 25158-CF-030
M.SMITH JAN. 2015
24VDC +
FROM [030-05] CF-CP
030-05-24V
01 24VDC COM 21
FROM [030-06]
CB-042-02
02 22
20A
BLUE/WHITE #14AWG
BLUE #14AWG
03 23
042-02
CB-042-04
2A
042-04 SAFETY CIRCUIT 030-06-COM
04 [ 046-01 ] 24
BLUE #16AWG TYP. BLUE/WHITE #16AWG TYP.
05 25
CB-042-06
15A AC-030-06
042-06 030-06-COM
06 AIR CONDITIONER 26
07 27
CB-042-08
2A MSR-046-01 C-CP-1
042-08 042-08A A1 A2 030-06-COM
08 28
33 34
09 29
CB-042-10
6A PLC POWER SUPPLY,
042-10 030-06-COM
10 INPUTS & OUTPUTS 30
[ 063-17 ]
11 31
12 32
13 33
14 34
15 35
16 36
17 37
18 38
19 39
20 40
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:52 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO 24VDC DISTRIBUTION
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B 25158-CF-042
M.SMITH JAN. 2015
CF-CP
24VDC 24VDC COM
FROM [042-04] FROM [042-04]
4601 MSR-046-01 Minotaur Safety Relay
24VDC
Monitoring 030-06-COM
DUAL CHANNEL AUTOMATIC RESET NO OUTPUT MONITORING Safety Relay
MURR.3000-33113-3020012
4602
042-04 A1 A2 030-06-COM
042-04 030-06-COM
BU 18 AWG WH/BU 18 AWG
S21
4603 S21-A
BU 18 AWG
(-)
4604
S11
S11-A
BU 18 AWG
AB.889R-F6ECA-5 (+)
ESTOP-CP-1 CBLDS-CF-1 CBLDS-CF-1
4605 DS-CF-1
S11-A S11-B S11-C S11-D S12
S11-A 3 4 S11-B JUMPER S11-C RD/WH (1) 12 11 RD/BK (5) S11-D
BU 18 AWG BU 18 AWG BU 18 AWG BU 18 AWG
ESTOP Logic Ch1
+CP/46
+CP/46
4606
4607
S21-A S21-B S21-C S21-D S22
S21-A 1 2 S21-B JUMPER S21-C RD (2) 22 21 RD/BU (6) S21-D
BU 18 AWG BU 18 AWG BU 18 AWG BU 18 AWG
+CP/46
Safety In
+CP/46
+CP/46
4608
S11-D X3
BU 18 AWG
4611
41 42
[065-24] FEEDBACK TO PLC
4614
33 34
[042-08] C-CP-1 CONTACTOR
4615
4616
nQS
4617
QS
4618
ESTOP-CP-1
4619
030-06-COM
042-04 3 4 046-19 x1 x2 030-06-COM
BU 18 AWG BU 18 AWG WH/BU 18 AWG
RED
4620
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:52 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO E-STOP WIRING
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B 25158-CF-046
M.SMITH JAN. 2015
CF-CP
6001
TERMINATOR MODULE
6003
SIE.6ES7193-4JA00-0AA0
4DO-CP-1
4DO-CP-2
4DO-CP-3
4DO-CP-4
4DO-CP-5
4DO-CP-6
4DI-CP-1
4DI-CP-2
4DI-CP-3
4DI-CP-4
4DI-CP-5
4DI-CP-6
CPU-CP-1
PM-CP-1
PM-CP-2
T-CP-1
/69-6901
/70-7001
/71-7101
IM 151-8 CPU INTERFASE MODULE
/63
/63
/65
/65
/66
/66
/67
/67
/63
/69
/70
/71
6004
SF SF
6005
SF
RUN
STOP BF-PN
P1 P2 P3
X1 MRES
6006 PROFINET
MT
ON
FRCE
6007
RUN
STOP
6008
ET 200S PWR 1 5 1 5 1 5 1 5 1 5 1 5 1 5 PWR 1 5 1 5 1 5 1 5 1 5
4JA00-0AA0
2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6
6ES7 193
P1 P2 P3 6ES7 138 6ES7 131 6ES7 131 6ES7 131 6ES7 131 6ES7 131 6ES7 131 6ES7 132 6ES7 138 6ES7 132 6ES7 132 6ES7 132 6ES7 132 6ES7 132
LINK 4CA01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4CA01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0 4BD01-0AA0
6009
X1 AUX1 AUX1
1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5
DC24V A A A A
4 8 4 8
6010 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6
3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7
6011
A A 4 8 4 8 4 8 4 8 4 8 4 8 4 8 A A 4 8 4 8 4 8 4 8 4 8
4 8 4 8
6012
A A A A A A A A A A A A A A A A A A A A A A A A
4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8
6013 A A A A A A A A A A A A A A A A A A A A A A A A
3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7
6014
6016
6017
6018
6019
6020
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO PLC OVERVIEW
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description Rev.
1
Date Name/Nom Revision Description Rev.
LINE 7B 25158-CF-060
M.SMITH JAN. 2015
CF-CP
6301
6302
6303
6305
TO NEXT MODULE TO NEXT MODULE
SF BACKPLANE POWER
SIEMENS BACKPLANE POWER P1 P1
BUS COUPLER BUS COUPLER
CBLETH-CF-1 P2 P2
RUN-P BF
SIE.6XV18402AH10 ETH1 P1
6306 20 m PROFINET
4x STOP ON
SIEMENS PROFINET CABLE ETH2 P2 SIEMENS SIEMENS
TO FILLER PROFINET
MRES FRCE
6307
ETH3 P3
PROFINET
RUN
STOP
6308
6309
6310 ET 200S
6311
2 6 2 6
6312
DC24V
1L+ 2L+ 1M 2M
3 7 3 7
6313
4 8 4 8
6314
2 3 4
1
6315
MSR-046-01
6316 042-10 063-16
BU AWG#16 13 14 BU AWG#16
030-06-COM
6317 WH/BU AWG#16
042-10
24VDC + BU AWG#16
FROM [042-10]
030-06-COM
WH/BU AWG#16
6318
6319
6320
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO PLC 24VDC WIRING
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B 25158-CF-063
M.SMITH JAN. 2015
SIE.6ES7193-4CA50-0AA0
SIE.6ES7131-4BD01-0AA0
CF-CP SIE.6ES7193-4CA50-0AA0
SIE.6ES7131-4BD01-0AA0
4DI-CP-1 4DI-CP-2
/60 /60
4x MODULO DE 4 ENTRADAS DIGITALES 4x DIGITAL INPUT MODULE
6501 24VDC 6521 24VDC
Slot 2 Slot 3
Address E0 Address E1
FROM PRIOR MODULE TO NEXT MODULE DE MODULO ANTERIOR A PROXIMO MODULO
6502 6522
POTENCIA BASE POSTERIOR POTENCIA EN BASE POSTERIOR
P1 ACOPLE DE BUS P1 P1 ACOPLE DE BUS P1
P2 P2 P2 P2
6503 6523
SS-CP-1
STOP MSR-046-01
START CLEANOUT
24V.3 E0.0 1 E1.0 1 EMERGENCY STOP
24V.3
IN0
E0.0
IN0
E1.0
6504 AWG#18 START 6524 AWG#18
BU
SAFETY RELAY
BU 41 42
FEEDBACK
E0.1 5 3
IN1
E0.1
6505 AWG#18 CLEANOUT 6525
DC24V
BU
A4
AUX1
6507 7 6527
DC24V
VFD-CP-1
A4 24V.7 1 2 E1.1 AWG#18 5 ELEVATOR
IN1
E1.1
6508 6528
AUX1 BU
VFD FEEDBACK
A8
AUX1
6509 6529 AWG#18 7
BU
DC24V
A8
AUX1
6510 6530
6511 6531
RESET FAULT
PB-CP-1 6m
PX-CF-11 4x
CBLPX-CF-11
24V.4 3 4 AWG#18 E0.2 2 1 4 E1.2 2
IN2
E0.2
IN2
E1.2
6512 RESET FAULT 6532 BK/4
BU
RED
3
A3 0V.A3 A3
BU/3
AUX1 AUX1
6514 6534 BK
PX-CF-21
CBLPX-CF-21
1 4 BK/4
BN/1
24V.4
3
6515 6535
BU/3
0V.A3
JOG
PB-CP-2 6m
PX-CF-12 4x
CBLPX-CF-12
24V.8 3 4 AWG#18 E0.3 6 1 4 E1.3 6
IN3
E0.3
IN3
E1.3
6516 JOG 6536 BK/4
BU
BLUE
3
A7 BU/3
0V.A7 A7
AUX1 AUX1
6518 6538 BK
PX-CF-22
CBLPX-CF-22
1 4 BK/4
BN/1 24V.4
3
6519 6539
BU/3 0V.A7
6520 6540
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:52 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO WIRING SCHEMATIC
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description Rev.
1
Date Name/Nom Revision Description Rev.
LINE 7B DIGITAL INPUTS 25158-CF-065
M.SMITH JAN. 2015
SIE.6ES7193-4CA50-0AA0
SIE.6ES7131-4BD01-0AA0
CF-CP SIE.6ES7193-4CA50-0AA0
SIE.6ES7131-4BD01-0AA0
4DI-CP-3 4DI-CP-4
/60 /60
10 m 10 m 4x DIGITAL INPUT MODULE 4x DIGITAL INPUT MODULE
6601 4x 4x 24VDC 6621 24VDC
CBLSPARE-CF-1 CBLSPARE-CF-2
Slot 4 Slot 5
Address E2 Address E3
6602 FROM PRIOR MODULE TO NEXT MODULE 6622 FROM PRIOR MODULE TO NEXT MODULE
6603 6623
2m
4x
PX-CF-13 PS-CF-10 AIR SUPPLY
CBLPX-CF-13
1 ELEVATOR DISCHARGE 1
1 4 E2.0 14 13 E3.0 PRESSURE SWITCH
IN0
E2.0
IN0
E3.0
6604 BK/4 6624 AWG#18
EXIT JAM SENSOR BU
BN/1
6607 6627
BU/3
2m
4x
PX-CF-14A C-CP-3
CBLPX-CF-14A FLATTOP
E2.1 5 DISCHARGE FULL SENSOR E3.1 5
IN1
IN1
1 4 AWG#18
E2.1
E3.1
6608 BK/4 6628 13 14
HIGH LEVEL AIRVEYOR CONTACTOR
BU
FEEDBACK
3
SS-CP-2
E2.2
IN2
E3.2
6612 6632
BU AWG18
CAP DETECTION VACUUM PUMP
1 UPSTREAM SENSOR CONTACTOR FEEDBACK
PUERTA DE ATASCO
/10-1020
A3 A3
AUX1 AUX1
6614 6634
6615 6635
ENCL-CF-4 ENCL-CF-3
PX-CF-15 CBLPX-CF-15 CB-CF-4 CB-CF-3
1 4 6 UPSIDE DOWN E3.3 6 FLATTOP AIR VEYOR
IN3
E2.3
IN3
E3.3
6616 BK/4 6636 13 14 066-36 13 14 AWG#18
CAP DETECTION BU
LOCAL DIOSCONNECT
1 DOWNSTREAM SENSOR FEEDBACK 1=OK
3
6617 BN/1
8 6637 24V.8 AWG#18 8
DC24V DC24V
24V.8 BU
BU/3
A7 A7
AUX1 AUX1
6618 6638
6619 6639
6620 6640
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:52 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO WIRING SCHEMATIC
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B DIGITAL INPUTS 25158-CF-066
M.SMITH JAN. 2015
SIE.6ES7193-4CA50-0AA0
SIE.6ES7131-4BD01-0AA0
CF-CP SIE.6ES7193-4CA50-0AA0
SIE.6ES7131-4BD01-0AA0
4DI-CP-5 4DI-CP-6
/60 /60
4x DIGITAL INPUT MODULE 4x DIGITAL INPUT MODULE
6701 24VDC 6721 24VDC
Slot 6 Slot 7
Address E4 Address E5
6702 FROM PRIOR MODULE TO NEXT MODULE 6722 FROM PRIOR MODULE TO NEXT MODULE
6703 6723
IN0
IN0
E4.0
E5.0
6704 6724
CHANNEL A
UNDERPRESSURE
3 3
6705 DC24V 6725 DC24V
A4 A4
AUX1 AUX1
6706 6726
6707 6727
IN1
E4.1
IN1
E5.1
6708 6728
CONTACTOR FEEDBACK CHANNEL B OVERPRESSURE
7 7
6709 6729
DC24V DC24V
A8 A8
AUX1 AUX1
6710 6730
6711 6731
IN2
E4.2
IN2
E5.2
6712 VIBRATOR 6732
START SELECTOR SWITCH
4 4
6713 6733
DC24V DC24V
A3 A3
AUX1 AUX1
6714 6734
6715 6735
IN3
E4.3
E5.3
6716 6736
SELECTOR SWITCH FEEDBACK
8 8
6717 6737
DC24V DC24V
A7 A7
AUX1 AUX1
6718 6738
6719 6739
6720 6740
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:53 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO WIRING SCHEMATIC
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B DIGITAL INPUTS 25158-CF-067
M.SMITH JAN. 2015
SIE.6ES7193-4CA50-0AA0
CF-CP SIE.6ES7193-4CA50-0AA0
SIE.6ES7132-4BD02-0AA0 SIE.6ES7132-4BD02-0AA0
4DO-CP-1 4DO-CP-2
/60 /60
4x DIGITAL OUTPUT MODULE 4x DIGITAL OUTPUT MODULE
6901 24VDC 6921 24VDC
Slot 8 Slot 10
Address Q0 Address Q1
VFD-CP-1
6903 6923 /30
SL-CP-1
STACK LIGHT BLUE
OUT0
OUT0
1 START VFD 1 18 20
Q0.0
Q1.0
Q0.0 BK X1 X2 0V.M8 AWG#18 Q1.0 0V.M4
DISCHARGE HIGH LEVEL START VFD COM
BELT MOTOR BU
(16H1_BL)
6904 BLUE 6924
3 3
M M
6905 A4 6925 A4
AUX1 AUX1
6906 6926
6907 6927
OUT1
5 Q0.1 SPEED SELECTION 5 Q1.1 29
Q0.1
Q1.1
6908 BN X1 X2
6928 AWG#18
RUNNING LOW SPEED CONTROL LSB
BU
(16H1_GR)
GREEN
7 7
6909 M 6929 M
A8 A8
AUX1 AUX1
6910 6930
6911 6931
0V.M8
6912 6932
OUT2
2 SPEED SELECTION 2 33
Q0.2
Q1.2
Q0.2 WH X1 X2 AWG#18 Q1.2
LOW PRIME MSB
6913 6933 CLEANOUT SPEED CONTROL BU
(16H1_AM)
YELLOW
4 4 AWG#18
M M
6914 6934 BU/WH
A3 A3
AUX1 AUX1
6915 6935
6916 6936
6917 6937
SV-CF-10
CBLSV-CF-10
STACK LIGHT RED BLOWOFF FAN MOTOR
OUT3
OUT3
6 Q0.3 6 Q1.3
Q0.3
Q1.3
GY X1 X2 BK/4
x1 x2
ALARM CONTACTOR
(16H1_RE)
6918 RED 6938
6920 6940
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:53 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO WIRING SCHEMATIC
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B DIGITAL OUPUTS 25158-CF-069
M.SMITH JAN. 2015
SIE.6ES7193-4CA50-0AA0
SIE.6ES7132-4BD02-0AA0
CF-CP SIE.6ES7193-4CA50-0AA0
SIE.6ES7132-4BD02-0AA0
4DO-CP-3 4DO-CP-4
/60 /60
4x DIGITAL OUTPUT MODULE 4x DIGITAL OUTPUT MODULE
7001 24VDC 7021 24VDC
Slot 11 Slot 12
Address Q2 Address Q3
7002 TO NEXT MODULE FROM PRIOR MODULE 7022 TO NEXT MODULE FROM PRIOR MODULE
7003 7023
SV-CF-11
CLEANOUT (OVERFLOW) CBLSV-CF-11 UPSIDE DOWN
OUT0
OUT0
1 Q2.0 1
Q2.0
Q3.0
BK/4
x1 x2
SOLENOID VALVE CAP REJECT CYLINDER
/CYLINDER SOLENOID VALVE SOLENOID VALVE
7004 7024
3 0V.M3 BU/3
3
M M
7005 7025
A4 A4
AUX1 AUX1
7006 7026
7007 7027
OUT1
BLOWNUZZLES 5 5
Q2.1
Q3.1
7008 7028 BLOWNUZLE
RINGLESS REJECT
SOLENOID VALVE
SOLENOID VALVE
7009 7029
7 7
M M
A8
AUX1 A8
AUX1
7010 7030
7011 7031
7012 7032
IONIZER 2
OUT2
OUT2
GATE SWITCH CYLINDER 2 2
Q2.2
Q3.2
BLOWNUZZLE
SOLENOID VALVE
7013 7033 SOLENOID VALVE
7014 4 7034
M 4
M
A3
AUX1 A3
AUX1
7015 7035
7016 7036
7017 7037
DEDUSTER VACUUM
CAP SIZE ADJUSTMENT
OUT3
OUT3
6 3 WAYS 6
Q2.3
Q3.3
CYLINDER SOLENOID VALVE
SOLENOID VALVE
7018 7038
8 8
M M
7019 7039
A7 A7
AUX1 AUX1
7020 7040
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:53 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO WIRING SCHEMATIC
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.
LINE 7B DIGITAL OUPUTS 25158-CF-070
M.SMITH JAN. 2015
SIE.6ES7193-4CA50-0AA0
CF-CP SIE.6ES7193-4CA50-0AA0
SIE.6ES7132-4BD02-0AA0 SIE.6ES7132-4BD02-0AA0
4DO-CP-5 4DO-CP-6
/60 /60
4x DIGITAL OUTPUT MODULE 4x DIGITAL OUTPUT MODULE
7101 7121
24VDC 24VDC
Slot 13 Slot 14
Address Q4 Address Q5
7102 7122
TO NEXT MODULE FROM PRIOR MODULE TO NEXT MODULE FROM PRIOR MODULE
7103 7123
C-CP-3
DEDUSTER VACUUM
OUT0
OUT0
1 FLATTOP AIRVEYOR 1 1 Q5.0
Q4.0
Q5.0
AWG#18 A1 A2
PUMP CONTACTOR
START CONTACTOR BU
7104 7124
3 3 AWG#18 0V.M3
M M
7105 7125 WH/BU
A4 A4
AUX1 AUX1
7106 7126
7107 7127
SV-CF-15A
CBLSV-CF-15A FLATTOP AIRVEYOR 2
OUT1
OUT1
CROWN JAM DOOR 5 5
Q4.1
Q5.1
7108 Q4.1 BK/4
x1 x2 7128
START CONTACTOR
OPEN SOLENOID VALVE
7109 7129
7 0V.M7 BU/3
7
M M
A8 A8
AUX1 AUX1
7110 7130
7111 7131
7112 7132
SV-CF-15B
CBLSV-CF-15B
OUT2
OUT2
CROWN JAM DOOR 2 FLATTOP AIRVEYOR 3 2
Q4.2
Q5.2
Q4.2 BK/4
x1 x2
A3 A3
AUX1 AUX1
7115 7135
7116 7136
7117 7137
OCTABIN DUMPER 1
OUT3
OUT3
6 FLATTOP AIRVEYOR 4 6
Q4.3
Q5.3
VIBRATOR CONTACTOR
START CONTACTOR
7118 7138
8 8
7119
M 7139
M
A7 A7
AUX1 AUX1
7120 7140
Project Manager / Responsable projet Others / Autres Client Description Page Description The drawings, Papers, plans etc shall remain the sole property of GECO CERMEX. GEBO CERMEX grants a Print Date Format
free of charge, non-exclusive right of use of these drawings Papers, plan for the agreed purpose. Copies or other
Gebo Cermex Canada Inc. M.GUENETTE reproductions of any kind, inwhole or in part, for any other purpose than the agreed purpose shall not be made 4/23/2015 8:53 B
1045 Highway 13 North
Laval, Quebec H7W 4V3 Design Manager / Responsable BE
APR.23 2015 MS VOLTAGE CHANGED FOR 440VAC 2
CONSTELLATION BRANDS CROWN FEEDER 2024 without the previous written agreement from GEBO CERMEX. Neither originals nor reproductions shall be
forwarded or made available to any third parties.
tel: (450) 973-3337 H.RIOUX NONE MEXICO WIRING SCHEMATIC
fax: (450) 973-333
WWW.GEBOCERMEX.COM
Date
JAN.27 2015
Date
MS
Name/Nom
FOR CONSTRUCTION
Revision Description
1
Rev. Date Name/Nom Revision Description Rev.