Umts Parameter Mapping (Huawei - Ericsson-Final

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 795

Network

Element Parameter ID Parameter Name Parameter Description

Cell DlHoCeCodeResvSf DL handover credit and code IdleQoffset1sn


reserved SF

Indicating whether the cell is


reserved for operators. If
the status of cell is
NOT_BARRED, and the cell is
reserved for operators, the
CellReservedForOperatorUs Cell reserved for operator UEs allocated with Access
Cell use Class 11 or 15 in the local
e PLMN can select or reselect
the cell. While the UEs
allocated with Access Class
0~9, 12 and 14 cannot select
or reselect the cell. For
details, see 3GPP TS 25.331

Indicating whether the UE


allocated with Access Class 0
can be allowed to initiate
Access class 0 barred access to the radio network.
Cell IsAccessClass0Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331
Indicating whether the UE
allocated with Access Class 1
can be allowed to initiate
Access class 1 barred access to the radio
Cell IsAccessClass1Barred indicator network.The UE judges
whether it belongs to this
access class based on the
SIM/USIM. For details, see
3GPP TS 25.331

Indicating whether the UE


allocated with Access Class 2
can be allowed to initiate
Access class 2 barred access to the radio network.
Cell IsAccessClass2Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331
Indicating whether the UE
allocated with Access Class 3
can be allowed to initiate
Access class 3 barred access to the radio network.
Cell IsAccessClass3Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331

Indicating whether the UE


allocated with Access Class 4
can be allowed to initiate
Access class 4 barred access to the radio network.
Cell IsAccessClass4Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331
Indicating whether the UE
allocated with Access Class 5
can be allowed to initiate
Access class 5 barred access to the radio network.
Cell IsAccessClass5Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331

Indicating whether the UE


allocated with Access Class 6
can be allowed to initiate
Access class 6 barred access to the radio network.
Cell IsAccessClass6Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331
Indicating whether the UE
allocated with Access Class 7
can be allowed to initiate
Access class 7 barred access to the radio network.
Cell IsAccessClass7Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331

Indicating whether the UE


allocated with Access Class 8
can be allowed to initiate
Access class 8 barred access to the radio network.
Cell IsAccessClass8Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331
Indicating whether the UE
allocated with Access Class 9
can be allowed to initiate
Access class 9 barred access to the radio network.
Cell IsAccessClass9Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331

Indicating whether the UE


allocated with Access Class
10 can be allowed to initiate
Access class 10 barred access to the radio network.
Cell IsAccessClass10Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331
Indicating whether the UE
allocated with Access Class
11 can be allowed to initiate
Access class 11 barred access to the radio network.
Cell IsAccessClass11Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331

Indicating whether the UE


allocated with Access Class
12 can be allowed to initiate
Access class 12 barred access to the radio network.
Cell IsAccessClass12Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331
Indicating whether the UE
allocated with Access Class
13 can be allowed to initiate
Access class 13 barred access to the radio network.
Cell IsAccessClass13Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331

Indicating whether the UE


allocated with Access Class
14 can be allowed to initiate
Access class 14 barred access to the radio network.
Cell IsAccessClass14Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331
Indicating whether the UE
allocated with Access Class
15 can be allowed to initiate
Access class 15 barred access to the radio network.
Cell IsAccessClass15Barred indicator
The UE judges whether it
belongs to this access class
based on the SIM/USIM. For
details, see 3GPP TS 25.331

The parameter sets the


target value of the uplink
Maximum Target Uplink load. HSUPA power control
RNC MaxTargetUlLoadFactor Load Factor on the NodeB side keeps
uplink load close to the
target value. For details, see
3GPP TS 25.433

When the ENU-based


admission algorithm is used
for uplink admission control,
this parameter defines the
total number of equivalent
UL total equivalent user
RNC UlTotalEqUserNum users corresponding to the
number 100% uplink load. Set this
parameter to suit the
admission control threshold
and the network's actual
situation.
Maximum number of users
supported by the HSDPA
channel. The user in this
parameter refers to the user
with services on the HSDPA
channel, regardless of the
number of RABs carried on
the HSDPA channel.
Maximum HSDPA user
Cell MaxHsdpaUserNum number Maximum HSDPA user
number cannot exceed the
HSDPA capability of the
NodeB product, In practice,
the value can be set based
on the cell type and the
richness of the available
HSDPA power and code
resources.

Maximum number of users


supported by the HSUPA
channel. The user in this
parameter refers to the user
with services on the HSUPA
channel, regardless of the
number of RABs carried on
the HSUPA channel.
Cell MaxHsupaUserNum Maximum HSUPA user Maximum HSUPA user
number number cannot exceed the
HSUPA capability of the
NodeB product, In practice,
the value can be set based
on the cell type and the
richness of the available
HSUPA power and code
resources.
Offset of the BCH transmit
power from the PCPICH
transmit power in a cell. For
Cell BCHPower BCH Transmit Power detailed information of this
parameter, refer to 3GPP TS
25.433 and TS 25.331.

Difference between the


transmit power of PICH and
Cell PICHPowerOffset PICH Power Offset that of PCPICH. For details,
refer to the 3GPP TS 25.433
protocol.

This parameter specifies the


power offset between the
transmit power of an AICH
Cell AICHPowerOffset AICH Power Offset
and that of P-CPICH. For
details, refer to the 3GPP TS
25.433 protocol.

The offset between the


Max Transmit Power of FACH transmit power and P-
Cell MaxFachPower FACH CPICH transmit power in a
cell.
Offset of the PCH transmit
power from the PCPICH
transmit power in a cell. For
Cell PCHPower PCH Power detailed information of this
parameter, refer to 3GPP TS
25.433.

Offset of the PSCH transmit


Cell PSCHPower PSCH Transmit Power power from the PCPICH
transmit power in a cell.

Offset of the SSCH transmit


Cell SSCHPower SSCH Transmit Power power from the PCPICH
transmit power in a cell.

The maximum number of


preambles transmitted in a
Cell PreambleRetransMax Max Preamble preamble ramping cycle. For
Retransmission detailed information of this
parameter, refer to 3GPP TS
25.211.

The power ramp step of the


random access preambles
transmitted before the UE
receives the acquisition
Cell PowerRampStep Power Increase Step indicator in the random
access process. For detailed
information of this
parameter, refer to 3GPP TS
25.211.
This parameter specifies a
constant used at calculation
of the initial transmit power
of the first preamble, to be
used in the random access
procedure. The formula is as
follows:
Preamble_Initial_Power =
PCPICH DL TX power -
CPICH_RSCP + UL
interference + Constant
Value. Where,
Constant Value for Preamble_Initial_Power is
Cell Constantvalue Calculating Initial TX Power the preamble initial TX
power, Primary CPICH DL TX
power is the downlink
transmit (TX) power of
PCPICH, CPICH_RSCP is the
receive signaling code
power of the PCPICH
measured by UEs, and UL
interference is the uplink
interference. For detailed
information of this
parameter, see 3GPP TS
25.331.

The power offset between


the last access preamble and
the message control part.
The power of the message
Cell PowerOffsetPpm Power Offset control part can be obtained
by adding the offset to the
access preamble power. For
detailed information of this
parameter, see 3GPP TS
25.213.
This parameter named
Measure Power Offset
Constant is used to compute
measurement power offset.
Measurement power offset
is used by UE to obtain total
received HS-PDSCH power.
The calculation for Measure
Cell HsPdschMPOConstEnum HS-PDSCH MPO Constant Power Offset is as shown
below: Measure Power
Offset = Max(-6,
Min(13,CellMaxPower -
PcpichPower - Measure
Power OffsetConstant)). For
details of the IE "Measure
Power Offset", refer to 3GPP
TS 25.214.

Duration of a CQI feedback


cycle when the UE is in the
multi-RLS state. In each CQI
feedback cycle, the UE
CQI Feedback Cycle k Multi- retransmits CQI for N times
Cell CQIFbCKforSHO repeatedly, where N
RLS represents the value of CQI
repetition factor in the
multi-RLS state. The value 0
indicates no CQI information
sent from the UE

RNC DRA_AQM_SWITCH Dynamic Resource #N/A


Allocation Switch
Indicating whether
attach/detach is allowed.
NOT_ALLOWED indicates
that MS cannot apply the
IMSI attach/detach
Attach/detach allowed
RNC ATT indication procedure. ALLOWED
indicates that MS can apply
the IMSI attach/detach
procedure. It is valid only
when [CN domain ID] is set
as CS_DOMAIN.

This parameter should be


set according to the actual
network situation . If there
is the Gs interface between
RNC NMO Network mode of operation SGSN and MSC/VLR this
parameter is set as MODE1;
otherwise, MODE2. It is valid
only when [CN domain ID] is
set as PS_DOMAIN.

The parameter specifies the


number of HS-DPSCH codes.
Cell Hspa Plus function This parameter is valid only
when Allocate Code Mode is
Cell DL_L2ENHANCED switch set to "Manual". For
detailed information about
this parameter, refer to
3GPP TS 25.308.

Cell Hspa Plus function


Cell E_FACH switch #N/A

Cell Hspa Plus function


Cell 64QAM switch #N/A

Cell Hspa Plus function


Cell MIMO switch #N/A

Cell Hspa Plus function


Cell 64QAM_MIMO switch #N/A
Cell Hspa Plus function
Cell DC_HSDPA switch #N/A

Cell DCMIMO_HSDP Cell Hspa Plus function #N/A


switch

If E_F_DPCH are selected,


the corresponding function
Cell E_F_DPCH_ON Cell Hspa Enhanced function will be enabled; otherwise,
switch disabled.

If Manual is chosen,
parameter " Code Number
for HS-PDSCH " determines
HS-PDSCH code number to
be allocated. If Automatic is
chosen, allocate HS-PDSCH
Allocate Code Mode code number between
Cell AllocCodeMode configured " Code Max
Number for HS-PDSCH " and
" Code Min Number for HS-
PDSCH ". For detailed
information of this
parameter, refer to 3GPP TS
25.308.

This parameter decides the


maximum number of
subscribers that the NodeB
Cell HsScchCodeNum Code Number for HS-SCCH can schedule in a TTI period.
For detailed information of
this parameter, refer to
3GPP TS 25.308.
The parameter determines
the maximum number of
HS-PDSCH codes (SF=16).
This parameter is valid only
when "Allocate Code Mode"
is set to "Automatic". The
number of codes used by
the HS-PDSCH is dynamically
set between "Code Min
Number for HS-PDSCH" and
"Code Max Number for HS-
Code Max Number for HS- PDSCH", based on whether
Cell HsPdschMaxCodeNum PDSCH the code tree is idle or busy.
When the code resource
used by the non-HSPA
services is little, the HS-
PDSCH uses the rest idle
codes as much as possible,
and the maximum number
of idle codes (SF=16
continuous codes) is equal
to the value of "Code Max
Number for HS-PDSCH".

The parameter specifies the


number of HS-DPSCH codes.
This parameter is valid only
Cell HsPdschCodeNum Code Number for HS-PDSCH when Allocate Code Mode is
set to "Manual". For
detailed information about
this parameter, refer to
3GPP TS 25.308.

The parameter specifies the


maximum number of
preambles to be used in one
Cell Mmax Max Preamble Loop preamble ramping cycle. For
detailed information of this
parameter, see 3GPP TS
25.331
T305 is started after the UE
enters CELL_FACH,
URA_PCH or CELL_PCH
state. If the UE receives CELL
UPDATE CONFIRM/URA
UPDATE CONFIRM message
and the UE enters
CELL_FACH, URA_PCH or
CELL_PCH state after state
transition, T305 is started
too. T305 is stopped after
RNC T305 Timer 305 the UE enters another state.
CELL UPDATE will be
transmitted upon the expiry
of this timer if T307 is not
activated and the UE detects
"in service area"; otherwise,
T307 will be started.
Protocol default value is 30.
"Infinity" means the cell will
not be updated.

Unit: min
A timer to RNC wait for
radio link restoration
indication in the radio link
procedure. Note: The value
range of "RlRstrTmr" is 1 to
300000 in the current
version. In a later version,
the value range changes into
100 to 300000. In the
RL restoration timer current version, if you enter
RNC RlRstrTmr a value within the range of 1
to 100 including 1, this value
can still be synchronized and
issued but the system
regards the value as 11000,
the recommended value.
Therefore, you are advised
not to enter a value smaller
than 100.

DL initial access rate of PS


background or interactive
service. When DCCC
function is enabled, the
RNC DlBeTraffInitBitrate DL BE traffic Initial bit rate downlink initial access rate
will be set to this value if the
downlink maximum rate is
higher than the initial access
rate.
UL initial access rate of PS
background or interactive
service. When DCCC
function is enabled, the
uplink initial access rate will
be set to this value if the
uplink maximum rate is
higher than the initial access
rate. A higher value
indicates that it takes
shorter time for BE services
to reach the maximum rate.
RNC UlBeTraffInitBitrate UL BE traffic Initial bit rate Note that the rate will be
decreased through
negotiation when
congestion occurs. A smaller
value indicates that BE
services is easier to be
accessed. It is not
recommended to set a too
small value, because it will
take longer time for BE
services to adjust to a higher
rate when needed.
RRC connection
establishment. - FACH: The
RRC connection is set up on
the common channel. -
DCH_3.4K_SIGNALLING: The
RRC connection is set up on
the 3.4 kbit/s dedicated
channel. -
DCH_6.8K_SIGNALLING: The
RRC connection is set up on
the 6.8 kbit/s dedicated
channel. -
DCH_13.6K_SIGNALLING:
The RRC connection is set up
on the 13.6 kbit/s dedicated
channel. -
DCH_27.2K_SIGNALLING:
Channel type for RRC
The RRC connection is set up
RNC SigChType establishment on the 27.2 kbit/s dedicated
channel. When
"EFachSwitch" is set to OFF
and this parameter is set to
FACH, the RRC connection is
set up on the common
channel. However, as
defined in 3GPP TS 25.331, if
a UE in the CELL_FACH state
initiates an RRC connection
setup request, the RRC
connection can be set up
only on the E_FACH, which
conflicts with the setting of
this switch. In this case, the
RRC connection is directly
set up on the 3.4 kbit/s
dedicated channel.
MAP_HSUPA_TTI_2MS_SWI Service Mapping Strategy When the switch is on, 2 ms
RNC TCH Switch TTI is supported for HSUPA.

Indicates whether the


videophone (VP) service is
limited in a cell. When the
Cell VPLimitInd VPLimitInd
indicator is "TRUE", it
indicates that the VP service
is limited in the cell.
This parameter specifies the
threshold of the traffic
volume of 4A event for
RNC BeF2DTvmThd BE F/R2D 4A Threshold triggering the transition of
BE services from FACH to
DCH.

When this switch is turned


on, the RNC does not
release PS RABs for inactive
UEs that use combined CS
and PS services (CS+xPS)
after the CS service is
released rather than after
the PS user inactivity timer
RNC PS_INACT_NOTREL_FOR_CS Switch for Not Releasing PS has expired. CS+xPS refers
PS_SWITCH RABs After Timeout
to one CS session and one or
more PS sessions. When this
switch is turned off, the RNC
releases PS RABs for inactive
UEs that use combined CS
and PS services (CS+xPS)
after the PS user inactivity
timer has expired
Whether CS and PS
combined services can use
HSUPA 2ms transmission
time interval (TTI). When
this switch is turned on, CS
Whether CS and PS
MAP_CSPS_TTI_2MS_LIMIT_ combined services can use and PS combined services
RNC cannot use HSUPA 2ms TTI,
SWITCH HSUPA 2ms transmission which reduces CS call drops
time interval (TTI)
caused by TTI switching.
When this switch is turned
off, CS and PS combined
services can use HSUPA 2ms
TTI.

MAP_CSPS_PS_UL_USE_DC
H_SWITCH: Whether uplink
PS services of CS and PS
combined services are
carried on DCHs. When this
switch is turned off, the RNC
Whether uplink PS services
MAP_CSPS_PS_UL_USE_DC determines the channel for
RNC H_SWITCH of CS and PS combined carrying uplink services of
services are carried on DCHs
CS and PS combined
services. When this switch is
turned on and CS and PS
combined services existing,
the uplink PS services must
be carried on DCHs.
CPICH RSCP access threshold
of the cell.This parameter is
the minimum required RX
level that corresponds to
CPICH RSCP. The UE can
camp on the cell only when
the measured CPICH RSCP is
greater than the value of
this parameter.
The settings of "Qrxlevmin"
and "Qqualmin" should be
considered along with each
other.
As for the impact on
network performance:
The larger the value of the
parameter is, the more
Cell Qrxlevmin Min RX Level difficult it is for the UE to
camp on the cell. The
smaller the value of the
parameter is, the easier it is
for the UE to camp on the
cell. But if the value is
excessively small, it is
possible that the UE cannot
receive the system
messages carried by
PCCPCH.
When this parameter is not
set to any value, the UE
adopts the corresponding
value of the current serving
cell, added through the ADD
UCELLSELRESEL command.
Generally, this parameter is
reselection between
different cells. Note that the
value 0 corresponds to the
default value defined in the
protocol.
Set the parameter as
follows:
1. Ensure that the UE can
reselect a cell when crossing
the non-soft-switch area of
the cell and that the UE
timely performs location
updates, cell updates, or
URA updates when
necessary.
2. Ensure that the UE does
not reselect a cell when it is
Cell Treselections Reselection delay time in the soft-switch area of the
cell. In this way, the
unnecessary location
updates, cell updates, and
URA updates are avoided.
3. Consider the difference
between cells that cover
different areas, for example
the cells covering highways
and cells covering densely
populated areas. TIf the
parameter is set to a
comparatively low value, the
ping-pong reselections may
be caused. The parameter
can be increased in
populated area and reduced
in high-speed movement. If
The minimum required
quality threshold
corresponding to CPICH
Ec/No. The UE can camp on
the cell only when the
measured CPICH Ec/No is
greater than the value of
this parameter. The higher
the parameter value is, the
more difficult it is for the UE
Cell Qqualmin Min quality level
to reside in the cell. The
lower parameter value is,
the easier it is for the UE to
reside in the cell, but it is
possible that the UE cannot
receive the system
messages that are sent
through the PCCPCH. For
detailed information, refer
to the 3GPP TS 25.304.

The minimum required


quality threshold
corresponding to CPICH
Ec/No. The UE can camp on
the cell only when the
measured CPICH Ec/No is
greater than the value of
this parameter. The higher
the parameter value is, the
more difficult it is for the UE
Cell Qqualmin Min Quality Level to reside in the cell. The
lower parameter value is,
the easier it is for the UE to
reside in the cell, but it is
possible that the UE cannot
receive the system
messages that are sent
through the PCCPCH. For
detailed information, refer
to the 3GPP TS 25.304.
The minimum required
quality threshold
corresponding to CPICH
Ec/No. The UE can camp on
the cell only when the
measured CPICH Ec/No is
greater than the value of
this parameter. The higher
the parameter value is, the
more difficult it is for the UE
Cell Qqualmin Min Quality Level
to reside in the cell. The
lower parameter value is,
the easier it is for the UE to
reside in the cell, but it is
possible that the UE cannot
receive the system
messages that are sent
through the PCCPCH. For
detailed information, refer
to the 3GPP TS 25.304.
CPICH RSCP access threshold
of the cell.This parameter is
the minimum required RX
level that corresponds to
CPICH RSCP. The UE can
camp on the cell only when
the measured CPICH RSCP is
greater than the value of
this parameter.
The settings of "Qrxlevmin"
and "Qqualmin" should be
considered along with each
other.
As for the impact on
network performance:
The larger the value of the
parameter is, the more
Cell Qrxlevmin Min RX Level difficult it is for the UE to
camp on the cell. The
smaller the value of the
parameter is, the easier it is
for the UE to camp on the
cell. But if the value is
excessively small, it is
possible that the UE cannot
receive the system
messages carried by
PCCPCH.
When this parameter is not
set to any value, the UE
adopts the corresponding
value of the current serving
cell, added through the ADD
UCELLSELRESEL command.
Generally, this parameter is
(CPICH Ec/No measured by
the UE) of the serving cell is
lower than this threshold
plus the [Qqualmin] of the
cell, the intra-frequency cell
reselection procedure will
be started. This parameter is
not configured when its
value is 127. The intra-
frequency cell reselection
has a priority higher than
the inter-frequency cell
reselection and inter-RAT
cell reselection, the intra-
frequency cell reselection
start threshold should be
higher than the inter-
Intra-freq cell reselection frequency cell reselection
Cell IdleSintrasearch threshold for idle mode start threshold and inter-
RAT cell reselection start
threshold. If the cell
reselection threshold is set
to a comparatively high
value, the UE may
frequently start cell
reselections, and the battery
of the UE may be largely
consumed. If the cell
reselection threshold is set
to a comparatively low
value, it is difficult for cell
reselections to be started,
and the UE may not timely
reside in the cells with good
quality, affecting the quality
of communication between
(CPICH Ec/No measured by
UE) of the serving cell is
lower than this threshold
plus the [Qqualmin] of the
cell, the inter-frequency cell
reselection procedure will
be started. This parameter is
not configured when its
value is 127. The intra-
frequency cell reselection
has a priority higher than
the inter-frequency cell
reselection and inter-RAT
cell reselection, the intra-
frequency cell reselection
start threshold should be
higher than the inter-
Inter-freq cell reselection frequency cell reselection
Cell IdleSintersearch threshold for idle mode start threshold and inter-
RAT cell reselection start
threshold. If the cell
reselection threshold is set
to a comparatively high
value, the UE may
frequently start cell
reselections, and the battery
of the UE may be largely
consumed. If the cell
reselection threshold is set
to a comparatively low
value, it is difficult for cell
reselections to be started,
and the UE may not timely
reside in the cells with good
quality, affecting the quality
of communication between
serving cell is lower than this
threshold plus the
[Qqualmin] of the cell, the
inter-RAT cell reselection
procedure will be started.
This parameter is not
configured when its value is
127. This parameter is not
configured when its value is
127. The intra-frequency cell
reselection has a priority
higher than the inter-
frequency cell reselection
and inter-RAT cell
reselection, the intra-
frequency cell reselection
start threshold should be
Inter-RAT cell reselection higher than the inter-
Cell SsearchRat threshold frequency cell reselection
start threshold and inter-
RAT cell reselection start
threshold. If the cell
reselection threshold is set
to a comparatively high
value, the UE may
frequently start cell
reselections, and the battery
of the UE may be largely
consumed. If the cell
reselection threshold is set
to a comparatively low
value, it is difficult for cell
reselections to be started,
and the UE may not timely
reside in the cells with good
quality, affecting the quality

Time delay to trigger event


2D. A UE reports an event
2D measurement report if
the conditions for triggering
Cell TimeToTrig2D Event 2D Trigger Delay event 2D are met and
persist during the time
period specified by this
parameter.
Time delay to trigger event
2F. A UE reports an event 2F
measurement report if the
Cell TimeToTrig2F Event 2F Trigger Delay conditions for triggering
event 2F are met and persist
during the time period
specified by this parameter.

Ec/No threshold of
triggering the inter-
frequency measurement for
PS non-HSPA services.
When Ec/No is used as the
measurement quantity for
inter-frequency handovers
Inter-freq R99 PS Measure of PS non-HSPA services, the
Cell InterFreqR99PsThd2DEcN0
Start Ec/No THD UE reports event 2D when
the measured Ec/No value is
lower than the value of this
parameter. Then, the RNC
sends a signaling message to
activate the compression
mode and start the inter-
frequency measurement.
is associated with slow
fading. If this parameter is
set to a greater value, the
probability of incorrect
decision becomes low;
however, the handover
algorithm becomes slow in
responding to signal change.
The emulation result shows
that the hysteresis setting
can effectively reduce the
average number of
handovers and the number
of incorrect handovers, thus
preventing unnecessary
handovers. The emulation
result also shows that the
UE at different data rates
Cell TrigTime2D 2D Event Trigger Delay Time may react differently to the
delay for triggering the
event. For the fast-moving
UE, the call drop rate is
more sensitive to the delay,
whereas, for the slow-
moving UE, the call drop
rate is less sensitive to the
delay. This can also reduce
ping-pong handovers and
incorrect handovers.
Therefore, for the cell where
most UEs are in fast
movement, this parameter
can be set to a smaller
value, whereas for the cell
where most UEs are in slow
movement, this parameter
is associated with slow
fading. If this parameter is
set to a greater value, the
probability of incorrect
decision becomes low;
however, the handover
algorithm becomes slow in
responding to signal change.
The emulation result shows
that the hysteresis setting
can effectively reduce the
average number of
handovers and the number
of incorrect handovers, thus
preventing unnecessary
handovers. The emulation
result also shows that the
UE at different data rates
Cell TrigTime2F 2F Event Trigger Delay Time may react differently to the
delay for triggering the
event. For the fast-moving
UE, the call drop rate is
more sensitive to the delay,
whereas, for the slow-
moving UE, the call drop
rate is less sensitive to the
delay. This can also reduce
ping-pong handovers and
incorrect handovers.
Therefore, for the cell where
most UEs are in fast
movement, this parameter
can be set to a smaller
value, whereas for the cell
where most UEs are in slow
movement, this parameter
algorithm becomes fast in
responding to signal change;
however, the probability of
incorrect decision becomes
high.
The emulation result shows
that the hysteresis setting
can effectively reduce the
average number of
handovers and the number
of incorrect handovers, thus
preventing unnecessary
handovers. The emulation
result also shows that the
UE at different data rates
may react differently to the
delay for triggering the
Cell TrigTime3A 3A Event Trigger Delay Time event. For the fast-moving
UE, the call drop rate is
more sensitive to the delay,
whereas, for the slow-
moving UE, the call drop
rate is less sensitive to the
delay. This can also reduce
ping-pong handovers and
incorrect handovers.
Therefore, for the cell where
most UEs are in fast
movement, this parameter
can be set to a smaller
value, whereas for the cell
where most UEs are in slow
movement, this parameter
can be set to a greater
value. The value of this
algorithm becomes fast in
responding to signal change;
however, the probability of
incorrect decision becomes
high.
The emulation result shows
that the hysteresis setting
can effectively reduce the
average number of
handovers and the number
of incorrect handovers, thus
preventing unnecessary
handovers. The emulation
result also shows that the
UE at different data rates
may react differently to the
delay for triggering the
Cell TrigTime3A 3A Event Trigger Delay Time event. For the fast-moving
UE, the call drop rate is
more sensitive to the delay,
whereas, for the slow-
moving UE, the call drop
rate is less sensitive to the
delay. This can also reduce
ping-pong handovers and
incorrect handovers.
Therefore, for the cell where
most UEs are in fast
movement, this parameter
can be set to a smaller
value, whereas for the cell
where most UEs are in slow
movement, this parameter
can be set to a greater
value. The value of this
recommended threshold is
-12 dB. In actual networks,
set this parameter to -14 dB
because the UEs in a cell
usually move at different
speeds. The emulation
result shows that the call
drop rate remains low for
the UEs moving at a speed
of 120 km/h when this
parameter is set to -14 dB.
If the cell is a macro cell, it
indicates that micro cells
exist in this cell. To enable
the micro cells to handle
more traffic, the
compressed mode start and
Inter-RAT CS Measure Start stop thresholds should be
Cell InterRATCSThd2DEcN0 Ec/No THD set higher, that is, the
thresholds for events 2D and
2F using CPICH RSCP are set
higher.
If the cell is a micro cell, the
default value should be
modified according to the
link budgeting result.
Event 2D and event 2F are
used to enable and disable
the compressed mode
respectively. When the cell
is located in the center of
the frequency coverage or
the inter-frequency
measurement quantity uses
both Ec/No and RSCP, then
the Ec/No value is used as
recommended threshold is
-12 dB.
In actual networks, set this
parameter to -14 dB
because the UEs in a cell
usually move at different
speeds. The emulation
result shows that the call
drop rate remains low for
the UEs moving at a speed
of 120 km/h when this
parameter is set to -14 dB.
If the cell is a macro cell, it
indicates that micro cells
exist in this cell. To enable
the micro cells to handle
more traffic, the
Inter-RAT R99 PS Measure
Cell InterRATR99PsThd2DEcN0 Start Ec/No THD compressed mode start and
stop thresholds should be
set higher, that is, the
thresholds for events 2D and
2F using CPICH RSCP are set
higher.
If the cell is a micro cell, the
default value should be
modified according to the
link budgeting result.
Event 2D and event 2F are
used to enable and disable
the compressed mode
respectively. When the cell
is located in the center of
the frequency coverage or
the inter-frequency
measurement quantity uses
When RSCP is used as the
measurement quantity for
PS domain non-HSPA
services, the UE reports
event 2D when the
measured RSCP value is
lower than this threshold.
Then, the RNC sends the
signaling to enable the
compressed mode and start
the inter-RAT measurement.
To enable the compressed
mode earlier, increase the
threshold of triggering event
2D; otherwise, decrease the
threshold of triggering event
2D. To prevent the frequent
Inter-RAT R99 PS Measure enabling and disabling of the
Cell InterRATR99PsThd2DRSCP Start RSCP THD compressed mode, increase
the difference between the
thresholds of triggering
event 2D and event 2F.
In most cases, users want to
be maintained within a 3G
network. Therefore, the
start threshold of the inter-
RAT measurement is set
smaller than that of the
inter-frequency
measurement in order to
trigger inter-frequency
easily. In scenarios where
inter-frequency neighboring
cells are unavailable or
where inter-frequency
coverage is insufficient, the
"PERIODICAL_REPORTING",
this parameter is used for
the assessment of inter-RAT
coverage handover. That is,
Tother_RAT in the following
formulas. This parameter is
the absolute threshold of
the cell of another RAT
(Received Signal Strength
Indicator: RSSI) for the inter-
RAT handover decision.
If the quality of the cell of
another RAT in the inter-RAT
measurement report fulfils
the following criterion:
Mother_RAT + CIO >=
Tother_RAT + H/2
Inter-RAT CS Handover Then, the system starts the
Cell TargetRatCsThd Decision THD trigger timer, and makes the
handover decision after the
timer expires. If the quality
of the cell of another RAT
fulfills the following criterion
before timeout:
Mother_RAT + CIO <
Tother_RAT - H/2
The RNC stops the timer and
waits for another inter-RAT
measurement report.
Here,
Mother_RAT is the
measurement result of the
GSM RSSI.
Tother_RAT is the inter-RAT
handover decision
threshold.
"PERIODICAL_REPORTING",
this parameter is used for
the assessment of inter-RAT
coverage handover. That is,
Tother_RAT in the following
formulas. This parameter is
the absolute threshold of
the cell of another RAT
(Received Signal Strength
Indicator: RSSI) for the inter-
RAT handover decision.
If the quality of the cell of
another RAT in the inter-RAT
measurement report fulfils
the following criterion:
Mother_RAT + CIO >=
Tother_RAT + H/2
Inter-RAT R99 PS Handover Then, the system starts the
Cell TargetRatR99PsThd Decision THD trigger timer, and makes the
handover decision after the
timer expires. If the quality
of the cell of another RAT
fulfills the following criterion
before timeout:
Mother_RAT + CIO <
Tother_RAT - H/2
The RNC stops the timer and
waits for another inter-RAT
measurement report.
Here,
Mother_RAT is the
measurement result of the
GSM RSSI.
Tother_RAT is the inter-RAT
handover decision
threshold.
"PERIODICAL_REPORTING",
this parameter is used for
the assessment of inter-RAT
coverage handover. That is,
Tother_RAT in the following
formulas. This parameter is
the absolute threshold of
the cell of another RAT
(Received Signal Strength
Indicator: RSSI) for the inter-
RAT handover decision.
If the quality of the cell of
another RAT in the inter-RAT
measurement report fulfils
the following criterion:
Mother_RAT + CIO >=
Tother_RAT + H/2
Inter-RAT HSPA Handover Then, the system starts the
Cell TargetRatHThd Decision THD trigger timer, and makes the
handover decision after the
timer expires. If the quality
of the cell of another RAT
fulfills the following criterion
before timeout:
Mother_RAT + CIO <
Tother_RAT - H/2
The RNC stops the timer and
waits for another inter-RAT
measurement report.
Here,
Mother_RAT is the
measurement result of the
GSM RSSI.
Tother_RAT is the inter-RAT
handover decision
threshold.
threshold can directly affect
the SHO ratio. Therefore,
the threshold should be
wisely chosen to achieve
smooth SHOs. The value of
this parameter determines
the SHO area and SHO ratio.
In the CDMA system, the
ratio of the UE involved in
soft handover should reach
30% to 40% to ensure
smooth handover. Based on
simulation results, when the
relative threshold is set to 5
dB, the ratio of the UE
involved in soft handover
(the number of cells in the
VP Service Event 1B Relative active set is at least 2) is
Cell IntraRelThdFor1BCSVP Threshold about 35%. You are advised
to set the relative threshold
to a great value (5 dB to 7
dB) during site deployment,
and to reduce the threshold
when the users increase. the
threshold must be higher
than 3 dB to avoid the ping-
pong handover.
You can set different relative
thresholds for event 1A and
event 1B to reduce the ping-
pong effect and change the
soft handover ratio. In
general applications, the
relative thresholds for
events 1A and 1B should be
consistent, and you can curb
threshold can directly affect
the SHO ratio. Therefore,
the threshold should be
wisely chosen to achieve
smooth SHOs. The value of
this parameter determines
the SHO area and SHO ratio.
In the CDMA system, the
ratio of the UE involved in
soft handover should reach
30% to 40% to ensure
smooth handover. Based on
simulation results, when the
relative threshold is set to 5
dB, the ratio of the UE
involved in soft handover
(the number of cells in the
CS Non-VP Service Event 1B active set is at least 2) is
Cell IntraRelThdFor1BCSNVP Relative Threshold about 35%. You are advised
to set the relative threshold
to a great value (5 dB to 7
dB) during site deployment,
and to reduce the threshold
when the users increase. the
threshold must be higher
than 3 dB to avoid the ping-
pong handover.
You can set different relative
thresholds for event 1A and
event 1B to reduce the ping-
pong effect and change the
soft handover ratio. In
general applications, the
relative thresholds for
events 1A and 1B should be
consistent, and you can curb
threshold can directly affect
the SHO ratio. Therefore,
the threshold should be
wisely chosen to achieve
smooth SHOs. The value of
this parameter determines
the SHO area and SHO ratio.
In the CDMA system, the
ratio of the UE involved in
soft handover should reach
30% to 40% to ensure
smooth handover. Based on
simulation results, when the
relative threshold is set to 5
dB, the ratio of the UE
involved in soft handover
(the number of cells in the
PS Service Event 1B Relative active set is at least 2) is
Cell IntraRelThdFor1BPS Threshold about 35%. You are advised
to set the relative threshold
to a great value (5 dB to 7
dB) during site deployment,
and to reduce the threshold
when the users increase. the
threshold must be higher
than 3 dB to avoid the ping-
pong handover.
You can set different relative
thresholds for event 1A and
event 1B to reduce the ping-
pong effect and change the
soft handover ratio. In
general applications, the
relative thresholds for
events 1A and 1B should be
consistent, and you can curb
This parameter specifies the
hysteretic value for event
1A. For details on the
definition of event 1A, see
3GPP TS 25.331.
Event 1A, as a key event,
refers to the event triggered
when a cell is added to the
active set. To ensure that
the handover is triggered
timely, the hysteresis for
event 1A should be smaller
than the hysteresis used for
events 1B, 1F, 1C, and 1D. A
too large difference
Cell HystFor1A 1A Hysteresis between the hysteresis
values affects the ratio of
soft handovers (SHOs). In
addition, filter coefficient
and trigger delay must be
considered in setting this
parameter. The value of this
parameter is associated with
slow fading. If this
parameter is set to a large
value, the possibility of ping-
pong handovers and
incorrect handover
decisions decreases but
events cannot be triggered
timely.

This parameter specifies the


hysteretic value for event
1B. The value of this
parameter is associated with
the slow fading, and it can
be used to reduce ping-pong
Cell HystFor1B 1B Hysteresis handovers and incorrect
handovers. For details on
the definition of this
parameter, see 3GPP TS
25.331.In addition, filter
coefficient and interval time
must be considered in
setting this parameter.
This parameter specifies the
hysteretic value for event
1D. The value of this
parameter is associated with
the slow fading, and it can
be used to reduce ping-pong
handovers and incorrect
Cell HystFor1D 1D Hysteresis
handovers. For details on
the definition of this
parameter, see 3GPP TS
25.331.In addition, filter
coefficient and interval time
must be considered in
setting this parameter.

Time delay to trigger event


2D. A UE reports an event
2D measurement report if
the conditions for triggering
RNC TimeToTrig2D Event 2D Trigger Delay event 2D are met and
persist during the time
period specified by this
parameter.

Time delay to trigger event


2F. A UE reports an event 2F
measurement report if the
RNC TimeToTrig2F Event 2F Trigger Delay conditions for triggering
event 2F are met and persist
during the time period
specified by this parameter.
Ec/No threshold of
triggering the inter-
frequency measurement for
CS services.
When Ec/No is used as the
measurement quantity for
inter-frequency handovers
Inter-freq CS Measure Start of CS services, the UE
RNC InterFreqCSThd2DEcN0 Ec/No THD reports event 2D when the
measured Ec/No value is
lower than the value of this
parameter. Then, the RNC
sends a signaling message to
activate the compression
mode and start the inter-
frequency measurement.

Ec/No threshold of stopping


the inter-frequency
measurement for CS
services.
When Ec/No is used as the
measurement quantity for
inter-frequency handovers
Inter-freq CS Measure Stop of CS services, the UE
RNC InterFreqCSThd2FEcN0 Ec/No THD reports event 2F when the
measured Ec/No value is
higher than the value of this
parameter. Then, the RNC
sends a signaling message to
deactivate the compression
mode and stop the inter-
frequency measurement.
Ec/No threshold of
triggering the inter-
frequency measurement for
PS non-HSPA services.
When Ec/No is used as the
measurement quantity for
inter-frequency handovers
RNC InterFreqR99PsThd2DEcN0 Inter-freq R99 PS Measure of PS non-HSPA services, the
Start Ec/No THD UE reports event 2D when
the measured Ec/No value is
lower than the value of this
parameter. Then, the RNC
sends a signaling message to
activate the compression
mode and start the inter-
frequency measurement.

Ec/No threshold of
triggering the inter-
frequency measurement for
HSPA services.
When Ec/No is used as the
measurement quantity for
inter-frequency handovers
RNC InterFreqHThd2DEcN0 Inter-freq H Measure Start of HSPA services, the UE
Ec/No THD reports event 2D when the
measured Ec/No value is
lower than the value of this
parameter. Then, the RNC
sends a signaling message to
activate the compression
mode and start the inter-
frequency measurement.
Ec/No threshold of stopping
the inter-frequency
measurement for PS non-
HSPA services.
When Ec/No is used as the
measurement quantity for
inter-frequency handovers
RNC InterFreqR99PsThd2FEcN0 Inter-freq R99 PS Measure of PS non-HSPA services, the
Stop Ec/No THD UE reports event 2F when
the measured Ec/No value is
higher than the value of this
parameter. Then, the RNC
sends a signaling message to
deactivate the compression
mode and stop the inter-
frequency measurement.

Ec/No threshold of stopping


the inter-frequency
measurement for HSPA
services.
When Ec/No is used as the
measurement quantity for
HSPA services, the UE
Inter-freq H Measure Stop
RNC InterFreqHThd2FEcN0 reports event 2F when the
Ec/No THD measured Ec/No value is
higher than the value of this
parameter. Then, the RNC
sends the signaling to
disable the compression
mode and stop the inter-
frequency measurement.
RSCP threshold of triggering
the inter-frequency
measurement for CS
services.
When RSCP is used as the
measurement quantity for
Inter-freq CS Measure Start CS services, the UE reports
RNC InterFreqCSThd2DRSCP event 2D when the
RSCP THD measured RSCP value is
lower than the value of this
parameter. Then, the RNC
sends the signaling to
activate the compression
mode and start the inter-
frequency measurement.

RSCP threshold of stopping


the inter-frequency
measurement for CS
services.
When RSCP is used as the
measurement quantity for
CS services, the UE reports
RNC InterFreqCSThd2FRSCP Inter-freq CS Measure Stop event 2F when the
RSCP THD
measured RSCP value is
higher than the value of this
parameter. Then, the RNC
sends the signaling to
disable the compression
mode and stop the inter-
frequency measurement.
RSCP threshold of triggering
the inter-frequency
measurement for PS non-
HSPA services.
When RSCP is used as the
measurement quantity for
Inter-freq R99 PS Measure HSPA services, the UE
RNC InterFreqR99PsThd2DRSCP Start RSCP THD reports event 2D when the
measured RSCP value is
lower than the value of this
parameter. Then, the RNC
sends the signaling to
activate the compression
mode and start the inter-
frequency measurement.

RSCP threshold of triggering


the inter-frequency
measurement for HSPA
services.
When RSCP is used as the
measurement quantity for
Inter-freq H Measure Start HSPA services, the UE
RNC InterFreqHThd2DRSCP reports event 2D when the
RSCP THD measured RSCP value is
lower than the value of this
parameter. Then, the RNC
sends the signaling to
activate the compression
mode and start the inter-
frequency measurement.
RSCP threshold of stopping
the inter-frequency
measurement for PS non-
HSPA services.
When RSCP is used as the
measurement quantity for
PS non-HSPA services, the
RNC InterFreqR99PsThd2FRSCP Inter-freq R99 PS Measure UE reports event 2F when
Stop RSCP THD
the measured RSCP value is
higher than the value of this
parameter. Then, the RNC
sends the signaling to
disable the compression
mode and stop the inter-
frequency measurement.

RSCP threshold of stopping


the inter-frequency
measurement for HSPA
services.
When RSCP is used as the
measurement quantity for
HSPA services, the UE
Inter-freq H Measure Stop
RNC InterFreqHThd2FRSCP reports event 2F when the
RSCP THD measured RSCP value is
higher than the value of this
parameter. Then, the RNC
sends the signaling to
disable the compression
mode and stop the inter-
frequency measurement.
is associated with slow
fading. If this parameter is
set to a greater value, the
probability of incorrect
decision becomes low;
however, the handover
algorithm becomes slow in
responding to signal change.
The emulation result shows
that the hysteresis setting
can effectively reduce the
average number of
handovers and the number
of incorrect handovers, thus
preventing unnecessary
handovers. The emulation
result also shows that the
UE at different data rates
RNC TrigTime2D 2D Event Trigger Delay Time may react differently to the
delay for triggering the
event. For the fast-moving
UE, the call drop rate is
more sensitive to the delay,
whereas, for the slow-
moving UE, the call drop
rate is less sensitive to the
delay. This can also reduce
ping-pong handovers and
incorrect handovers.
Therefore, for the cell where
most UEs are in fast
movement, this parameter
can be set to a smaller
value, whereas for the cell
where most UEs are in slow
movement, this parameter
is associated with slow
fading. If this parameter is
set to a greater value, the
probability of incorrect
decision becomes low;
however, the handover
algorithm becomes slow in
responding to signal change.
The emulation result shows
that the hysteresis setting
can effectively reduce the
average number of
handovers and the number
of incorrect handovers, thus
preventing unnecessary
handovers. The emulation
result also shows that the
UE at different data rates
RNC TrigTime2F 2F Event Trigger Delay Time may react differently to the
delay for triggering the
event. For the fast-moving
UE, the call drop rate is
more sensitive to the delay,
whereas, for the slow-
moving UE, the call drop
rate is less sensitive to the
delay. This can also reduce
ping-pong handovers and
incorrect handovers.
Therefore, for the cell where
most UEs are in fast
movement, this parameter
can be set to a smaller
value, whereas for the cell
where most UEs are in slow
movement, this parameter
recommended threshold is
-12 dB. In actual networks,
set this parameter to -14 dB
because the UEs in a cell
usually move at different
speeds. The emulation
result shows that the call
drop rate remains low for
the UEs moving at a speed
of 120 km/h when this
parameter is set to -14 dB.
If the cell is a macro cell, it
indicates that micro cells
exist in this cell. To enable
the micro cells to handle
more traffic, the
compressed mode start and
Inter-RAT CS Measure Start stop thresholds should be
RNC InterRATCSThd2DEcN0 Ec/No THD set higher, that is, the
thresholds for events 2D and
2F using CPICH RSCP are set
higher.
If the cell is a micro cell, the
default value should be
modified according to the
link budgeting result.
Event 2D and event 2F are
used to enable and disable
the compressed mode
respectively. When the cell
is located in the center of
the frequency coverage or
the inter-frequency
measurement quantity uses
both Ec/No and RSCP, then
the Ec/No value is used as
should consider two factors,
moving speed of the UE and
cell radius.
When Ec/No is used as the
measurement quantity for
CS services, the UE reports
event 2F when the
measured Ec/No value is
higher than the value of this
parameter. Then, the RNC
sends the signaling to
disable the compressed
mode and stop the inter-
frequency measurement.
If the cell is a macro cell, it
indicates that micro cells
exist in this cell. To enable
Inter-RAT CS Measure Stop the micro cells to handle
RNC InterRATCSThd2FEcN0 Ec/No THD more traffic, the
compressed mode start and
stop thresholds should be
set higher, that is, the
thresholds for events 2D and
2F using CPICH RSCP are set
higher.
If the cell is a micro cell, the
default value should be
modified according to the
link budgeting result.
Event 2D and event 2F are
used to enable and disable
the compressed mode
respectively. When the cell
is located in the center of
the frequency coverage or
the inter-frequency
recommended threshold is
-12 dB.
In actual networks, set this
parameter to -14 dB
because the UEs in a cell
usually move at different
speeds. The emulation
result shows that the call
drop rate remains low for
the UEs moving at a speed
of 120 km/h when this
parameter is set to -14 dB.
If the cell is a macro cell, it
indicates that micro cells
exist in this cell. To enable
the micro cells to handle
more traffic, the
Inter-RAT R99 PS Measure
RNC InterRATR99PsThd2DEcN0 Start Ec/No THD compressed mode start and
stop thresholds should be
set higher, that is, the
thresholds for events 2D and
2F using CPICH RSCP are set
higher.
If the cell is a micro cell, the
default value should be
modified according to the
link budgeting result.
Event 2D and event 2F are
used to enable and disable
the compressed mode
respectively. When the cell
is located in the center of
the frequency coverage or
the inter-frequency
measurement quantity uses
-12 dB.
In actual networks, set this
parameter to -14 dB
because the UEs in a cell
usually move at different
speeds. The emulation
result shows that the call
drop rate remains low for
the UEs moving at a speed
of 120 km/h when this
parameter is set to -14 dB.
If the cell is a macro cell, it
indicates that micro cells
exist in this cell. To enable
the micro cells to handle
more traffic, the
compressed mode start and
Inter-RAT HSPA Measure
RNC InterRATHThd2DEcN0 Start Ec/No THD stop thresholds should be
set higher, that is, the
thresholds for events 2D and
2F using CPICH RSCP are set
higher.
If the cell is a micro cell, the
default value should be
modified according to the
link budgeting result.
Event 2D and event 2F are
used to enable and disable
the compressed mode
respectively. When the cell
is located in the center of
the frequency coverage or
the inter-frequency
measurement quantity uses
both Ec/No and RSCP, then
setting of this parameter
should consider two factors,
moving speed of the UE and
cell radius.
When Ec/No is used as the
measurement quantity for
PS domain HSPA services,
the UE reports event 2F
when the measured Ec/No
value is higher than this
threshold. Then, the RNC
sends the signaling to
disable the compressed
mode and stop the inter-
frequency measurement.
If the cell is a macro cell, it
indicates that micro cells
Inter-RAT R99 PS Measure exist in this cell. To enable
RNC InterRATR99PsThd2FEcN0 Stop Ec/No THD the micro cells to handle
more traffic, the
compressed mode start and
stop thresholds should be
set higher, that is, the
thresholds for events 2D and
2F using CPICH RSCP are set
higher.
If the cell is a micro cell, the
default value should be
modified according to the
link budgeting result.
Event 2D and event 2F are
used to enable and disable
the compressed mode
respectively. When the cell
is located in the center of
the frequency coverage or
should consider two factors,
moving speed of the UE and
cell radius.
When Ec/No is used as the
measurement quantity for
HSPA services, the UE
reports event 2F when the
measured Ec/No value is
higher than the value of this
parameter. Then, the RNC
sends the signaling to
disable the compression
mode and stop the inter-
frequency measurement.
If the cell is a macro cell, it
indicates that micro cells
exist in this cell. To enable
Inter-RAT HSPA Measure the micro cells to handle
RNC InterRATHThd2FEcN0 Stop Ec/No THD more traffic, the
compressed mode start and
stop thresholds should be
set higher, that is, the
thresholds for events 2D and
2F using CPICH RSCP are set
higher.
If the cell is a micro cell, the
default value should be
modified according to the
link budgeting result.
Event 2D and event 2F are
used to enable and disable
the compressed mode
respectively. When the cell
is located in the center of
the frequency coverage or
the inter-frequency
When RSCP is used as the
measurement quantity for
CS services, the UE reports
event 2D when the
measured RSCP value is
lower than this threshold.
Then, the RNC sends the
signaling to enable the
compressed mode and start
the inter-RAT measurement.
To enable the compressed
mode earlier, increase the
threshold of triggering event
2D; otherwise, decrease the
threshold of triggering event
2D. To prevent the frequent
enabling and disabling of the
Inter-RAT CS Measure Start compressed mode, increase
RNC InterRATCSThd2DRSCP RSCP THD the difference between the
thresholds of triggering
event 2D and event 2F.
In most cases, users want to
be maintained within a 3G
network. Therefore, the
start threshold of the inter-
RAT measurement is set
smaller than that of the
inter-frequency
measurement in order to
trigger inter-frequency
easily. In scenarios where
inter-frequency neighboring
cells are unavailable or
where inter-frequency
coverage is insufficient, the
inter-RAT measurement

Threshold of stopping inter-


RAT measurement for CS
services when measurement
quantity is RSCP.
When RSCP is used as the
measurement quantity for
Inter-RAT CS Measure Stop CS services, the UE reports
RNC InterRATCSThd2FRSCP RSCP THD event 2F when the
measured RSCP value is
larger than this threshold.
Then, the RNC sends the
signaling to disable the
compressed mode and stop
the inter-RAT measurement.
When RSCP is used as the
measurement quantity for
PS domain non-HSPA
services, the UE reports
event 2D when the
measured RSCP value is
lower than this threshold.
Then, the RNC sends the
signaling to enable the
compressed mode and start
the inter-RAT measurement.
To enable the compressed
mode earlier, increase the
threshold of triggering event
2D; otherwise, decrease the
threshold of triggering event
2D. To prevent the frequent
Inter-RAT R99 PS Measure enabling and disabling of the
RNC InterRATR99PsThd2DRSCP Start RSCP THD compressed mode, increase
the difference between the
thresholds of triggering
event 2D and event 2F.
In most cases, users want to
be maintained within a 3G
network. Therefore, the
start threshold of the inter-
RAT measurement is set
smaller than that of the
inter-frequency
measurement in order to
trigger inter-frequency
easily. In scenarios where
inter-frequency neighboring
cells are unavailable or
where inter-frequency
coverage is insufficient, the
When RSCP is used as the
measurement quantity for
HSPA services, the UE
reports event 2D when the
measured RSCP value is
lower than this threshold.
Then, the RNC sends the
signaling to enable the
compressed mode and start
the inter-RAT measurement.
To enable the compressed
mode earlier, increase the
threshold of triggering event
2D; otherwise, decrease the
threshold of triggering event
2D. To prevent the frequent
enabling and disabling of the
Inter-RAT HSPA Measure compressed mode, increase
RNC InterRATHThd2DRSCP Start RSCP THD the difference between the
thresholds of triggering
event 2D and event 2F.
In most cases, users want to
be maintained within a 3G
network. Therefore, the
start threshold of the inter-
RAT measurement is set
smaller than that of the
inter-frequency
measurement in order to
trigger inter-frequency
easily. In scenarios where
inter-frequency neighboring
cells are unavailable or
where inter-frequency
coverage is insufficient, the
inter-RAT measurement

Threshold of stopping inter-


RAT measurement for PS
domain non-HSPA services
when the measurement
quantity is RSCP.
When RSCP is used as the
measurement quantity for
Inter-RAT R99 PS Measure PS domain non-HSPA
RNC InterRATR99PsThd2FRSCP Stop RSCP THD services, the UE reports
event 2F when the
measured RSCP value is
larger than this threshold.
Then, the RNC sends the
signaling to disable the
compressed mode and stop
the inter-RAT measurement.
Threshold of stopping inter-
RAT measurement for HSPA
services when measurement
quantity is RSCP.
When RSCP is used as the
measurement quantity for
Inter-RAT HSPA Measure HSPA services, the UE
RNC InterRATHThd2FRSCP
Stop RSCP THD reports event 2F when the
measured RSCP value is
larger than this threshold.
Then, the RNC sends the
signaling to disable the
compressed mode and stop
the inter-RAT measurement.
"PERIODICAL_REPORTING",
this parameter is used for
the assessment of inter-RAT
coverage handover. That is,
Tother_RAT in the following
formulas. This parameter is
the absolute threshold of
the cell of another RAT
(Received Signal Strength
Indicator: RSSI) for the inter-
RAT handover decision.
If the quality of the cell of
another RAT in the inter-RAT
measurement report fulfils
the following criterion:
Mother_RAT + CIO >=
Tother_RAT + H/2
Inter-RAT CS Handover Then, the system starts the
RNC TargetRatCsThd Decision THD trigger timer, and makes the
handover decision after the
timer expires. If the quality
of the cell of another RAT
fulfills the following criterion
before timeout:
Mother_RAT + CIO <
Tother_RAT - H/2
The RNC stops the timer and
waits for another inter-RAT
measurement report.
Here,
Mother_RAT is the
measurement result of the
GSM RSSI.
Tother_RAT is the inter-RAT
handover decision
threshold.
"PERIODICAL_REPORTING",
this parameter is used for
the assessment of inter-RAT
coverage handover. That is,
Tother_RAT in the following
formulas. This parameter is
the absolute threshold of
the cell of another RAT
(Received Signal Strength
Indicator: RSSI) for the inter-
RAT handover decision.
If the quality of the cell of
another RAT in the inter-RAT
measurement report fulfils
the following criterion:
Mother_RAT + CIO >=
Tother_RAT + H/2
Inter-RAT R99 PS Handover Then, the system starts the
RNC TargetRatR99PsThd Decision THD trigger timer, and makes the
handover decision after the
timer expires. If the quality
of the cell of another RAT
fulfills the following criterion
before timeout:
Mother_RAT + CIO <
Tother_RAT - H/2
The RNC stops the timer and
waits for another inter-RAT
measurement report.
Here,
Mother_RAT is the
measurement result of the
GSM RSSI.
Tother_RAT is the inter-RAT
handover decision
threshold.
"PERIODICAL_REPORTING",
this parameter is used for
the assessment of inter-RAT
coverage handover. That is,
Tother_RAT in the following
formulas. This parameter is
the absolute threshold of
the cell of another RAT
(Received Signal Strength
Indicator: RSSI) for the inter-
RAT handover decision.
If the quality of the cell of
another RAT in the inter-RAT
measurement report fulfils
the following criterion:
Mother_RAT + CIO >=
Tother_RAT + H/2
Inter-RAT HSPA Handover Then, the system starts the
RNC TargetRatHThd Decision THD trigger timer, and makes the
handover decision after the
timer expires. If the quality
of the cell of another RAT
fulfills the following criterion
before timeout:
Mother_RAT + CIO <
Tother_RAT - H/2
The RNC stops the timer and
waits for another inter-RAT
measurement report.
Here,
Mother_RAT is the
measurement result of the
GSM RSSI.
Tother_RAT is the inter-RAT
handover decision
threshold.
threshold can directly affect
the SHO ratio. Therefore,
the threshold should be
wisely chosen to achieve
smooth SHOs. The value of
this parameter determines
the SHO area and SHO ratio.
In the CDMA system, the
ratio of the UE involved in
soft handover should reach
30% to 40% to ensure
smooth handover. Based on
simulation results, when the
relative threshold is set to 5
dB, the ratio of the UE
involved in soft handover
(the number of cells in the
VP Service Event 1A Relative active set is at least 2) is
RNC IntraRelThdFor1ACSVP Threshold about 35%. you are advised
to set the relative threshold
to a great value (5 dB to 7
dB) during site deployment,
and to reduce the threshold
when the users increase. the
threshold must be higher
than 3 dB to avoid the ping-
pong handover.
You can set different relative
thresholds for event 1A and
event 1B to reduce the ping-
pong effect and change the
soft handover ratio. In
general applications, the
relative thresholds for
events 1A and 1B should be
consistent, and you can curb
the SHO ratio. Therefore,
the threshold should be
wisely chosen to achieve
smooth SHOs.
The value of this parameter
determines the SHO area
and SHO ratio. In the CDMA
system, the ratio of the UE
involved in soft handover
should reach 30% to 40% to
ensure smooth handover.
Based on simulation results,
when the relative threshold
is set to 5 dB, the ratio of
the UE involved in soft
handover (the number of
cells in the active set is at
CS Non-VP Service Event 1A
RNC IntraRelThdFor1ACSNVP Relative THD least 2) is about 35%. you
are advised to set the
relative threshold to a great
value (5 dB to 7 dB) during
site deployment, and to
reduce the threshold when
the users increase. the
threshold must be higher
than 3 dB to avoid the ping-
pong handover.
You can set different relative
thresholds for event 1A and
event 1B to reduce the ping-
pong effect and change the
soft handover ratio. In
general applications, the
relative thresholds for
events 1A and 1B should be
threshold can directly affect
the SHO ratio. Therefore,
the threshold should be
wisely chosen to achieve
smooth SHOs. The value of
this parameter determines
the SHO area and SHO ratio.
In the CDMA system, the
ratio of the UE involved in
soft handover should reach
30% to 40% to ensure
smooth handover. Based on
simulation results, when the
relative threshold is set to 5
dB, the ratio of the UE
involved in soft handover
(the number of cells in the
PS Service Event 1A Relative active set is at least 2) is
RNC IntraRelThdFor1APS Threshold about 35%. You are advised
to set the relative threshold
to a great value (5 dB to 7
dB) during site deployment,
and to reduce the threshold
when the users increase. the
threshold must be higher
than 3 dB to avoid the ping-
pong handover.
You can set different relative
thresholds for event 1A and
event 1B to reduce the ping-
pong effect and change the
soft handover ratio. In
general applications, the
relative thresholds for
events 1A and 1B should be
consistent, and you can curb
threshold can directly affect
the SHO ratio. Therefore,
the threshold should be
wisely chosen to achieve
smooth SHOs. The value of
this parameter determines
the SHO area and SHO ratio.
In the CDMA system, the
ratio of the UE involved in
soft handover should reach
30% to 40% to ensure
smooth handover. Based on
simulation results, when the
relative threshold is set to 5
dB, the ratio of the UE
involved in soft handover
(the number of cells in the
VP Service Event 1B Relative active set is at least 2) is
RNC IntraRelThdFor1BCSVP Threshold about 35%. You are advised
to set the relative threshold
to a great value (5 dB to 7
dB) during site deployment,
and to reduce the threshold
when the users increase. the
threshold must be higher
than 3 dB to avoid the ping-
pong handover.
You can set different relative
thresholds for event 1A and
event 1B to reduce the ping-
pong effect and change the
soft handover ratio. In
general applications, the
relative thresholds for
events 1A and 1B should be
consistent, and you can curb
threshold can directly affect
the SHO ratio. Therefore,
the threshold should be
wisely chosen to achieve
smooth SHOs. The value of
this parameter determines
the SHO area and SHO ratio.
In the CDMA system, the
ratio of the UE involved in
soft handover should reach
30% to 40% to ensure
smooth handover. Based on
simulation results, when the
relative threshold is set to 5
dB, the ratio of the UE
involved in soft handover
(the number of cells in the
CS Non-VP Service Event 1B active set is at least 2) is
RNC IntraRelThdFor1BCSNVP Relative Threshold about 35%. You are advised
to set the relative threshold
to a great value (5 dB to 7
dB) during site deployment,
and to reduce the threshold
when the users increase. the
threshold must be higher
than 3 dB to avoid the ping-
pong handover.
You can set different relative
thresholds for event 1A and
event 1B to reduce the ping-
pong effect and change the
soft handover ratio. In
general applications, the
relative thresholds for
events 1A and 1B should be
consistent, and you can curb
threshold can directly affect
the SHO ratio. Therefore,
the threshold should be
wisely chosen to achieve
smooth SHOs. The value of
this parameter determines
the SHO area and SHO ratio.
In the CDMA system, the
ratio of the UE involved in
soft handover should reach
30% to 40% to ensure
smooth handover. Based on
simulation results, when the
relative threshold is set to 5
dB, the ratio of the UE
involved in soft handover
(the number of cells in the
PS Service Event 1B Relative active set is at least 2) is
RNC IntraRelThdFor1BPS Threshold about 35%. You are advised
to set the relative threshold
to a great value (5 dB to 7
dB) during site deployment,
and to reduce the threshold
when the users increase. the
threshold must be higher
than 3 dB to avoid the ping-
pong handover.
You can set different relative
thresholds for event 1A and
event 1B to reduce the ping-
pong effect and change the
soft handover ratio. In
general applications, the
relative thresholds for
events 1A and 1B should be
consistent, and you can curb
This parameter specifies the
hysteretic value for event
1A. For details on the
definition of event 1A, see
3GPP TS 25.331.
Event 1A, as a key event,
refers to the event triggered
when a cell is added to the
active set. To ensure that
the handover is triggered
timely, the hysteresis for
event 1A should be smaller
than the hysteresis used for
events 1B, 1F, 1C, and 1D. A
too large difference
RNC HystFor1A 1A Hysteresis between the hysteresis
values affects the ratio of
soft handovers (SHOs). In
addition, filter coefficient
and trigger delay must be
considered in setting this
parameter. The value of this
parameter is associated with
slow fading. If this
parameter is set to a large
value, the possibility of ping-
pong handovers and
incorrect handover
decisions decreases but
events cannot be triggered
timely.

This parameter specifies the


hysteretic value for event
1B. The value of this
parameter is associated with
the slow fading, and it can
be used to reduce ping-pong
RNC HystFor1B 1B Hysteresis handovers and incorrect
handovers. For details on
the definition of this
parameter, see 3GPP TS
25.331.In addition, filter
coefficient and interval time
must be considered in
setting this parameter.
This parameter specifies the
hysteretic value for event
1D. The value of this
parameter is associated with
the slow fading, and it can
be used to reduce ping-pong
handovers and incorrect
RNC HystFor1D 1D Hysteresis
handovers. For details on
the definition of this
parameter, see 3GPP TS
25.331.In addition, filter
coefficient and interval time
must be considered in
setting this parameter.

detection of event 1A and


sending of the measurement
report. The value of this
parameter is associated with
slow fading. If this
parameter is set to a greater
value, the probability of
incorrect decision becomes
low; however, the handover
algorithm becomes slow in
responding to signal change.
The time-to-trigger
mechanism is introduced for
the following purposes:
- reducing the number of
wrong event reports caused
by burst signals,
RNC TrigTime1A Event 1A Triggering Delay - preventing the ping-pong
handover,
- reducing the impact of
shadow fading on event
decisions.
Setting an appropriate
triggering delay effectively
reduces the average number
of handovers and the
number of wrong
handovers, preventing
unnecessary handovers.
If the handover cannot be
triggered in time, the time-
to-trigger parameter for
event 1A needs to be
changed to 200 ms or 100
ms, and the delay for event
detection of event 1B and
sending of the measurement
report. The value of this
parameter is associated with
slow fading. If this
parameter is set to a greater
value, the probability of
incorrect decision becomes
low; however, the handover
algorithm becomes slow in
responding to signal change.
The time-to-trigger
mechanism is introduced for
the following purposes:
- reducing the number of
wrong event reports caused
by burst signals,
RNC TrigTime1B Event 1B Triggering Delay - preventing the ping-pong
handover,
- reducing the impact of
shadow fading on event
decisions.
Setting an appropriate
interval time effectively
reduces the average number
of handovers and the
number of wrong
handovers, preventing
unnecessary handovers.
If the handover cannot be
triggered in time, the time-
to-trigger parameter for
event 1A needs to be
changed to 200 ms or 100
ms, and the delay for event
This parameter specifies the
interval time between
detection of event 1D and
sending of the measurement
report. The value of this
parameter is associated with
slow fading. If this
parameter is set to a greater
value, the probability of
incorrect decision becomes
low; however, the handover
algorithm becomes slow in
responding to signal change.
The time-to-trigger
mechanism is introduced for
RNC TrigTime1D Event 1D Triggering Delay the following purposes:
- reducing the number of
wrong event reports caused
by burst signals,
- preventing the ping-pong
handover,
- reducing the impact of
shadow fading on event
decisions.
Setting an appropriate
interval time effectively
reduces the average number
of handovers and the
number of wrong
handovers, preventing
unnecessary handovers.
Interval at which event 1A is
reported after the reporting
mode is changed to
periodical reporting.
Generally, event 1A is
reported only once. To avoid
the loss of measurement
reports, the UE sets the
mode of reporting event 1A
to periodical if the cell
reporting event 1A is not
Event 1A to Periodical
RNC ReportIntervalfor1A Report Period added to the active set in a
specified period of time.
Event 1A is reported for
"PeriodMRReportNumfor1A
" times at the interval
specified by this parameter.
If the mode of reporting
event 1A is set to
"NON_PERIODIC_REPORT",
the UE cannot change the
event 1A reporting mode to
periodical.
Interval at which event 1A is
reported after the reporting
mode is changed to
periodical reporting.
Generally, event 1C is
reported only once. To avoid
the loss of measurement
reports, the UE set the
mode of reporting event 1C
to periodical if the cell
reporting event 1C is not
Event 1C to Periodical
RNC ReportIntervalfor1C Report Period added to the active set in a
specified period of time.
Event 1C is reported for
"PeriodMRReportNumfor1C
" times at the interval
specified by this
parameter.If the mode of
reporting event 1C is set to
"NON_PERIODIC_REPORT",
the UE cannot change the
event 1C reporting mode to
periodical.

This parameter specifies the


hysteretic value for event
1C. The value of this
parameter is associated with
the slow fading, and it can
be used to reduce ping-pong
RNC HystFor1C 1C Hysteresis handovers and incorrect
handovers. For details on
the definition of this
parameter, see 3GPP TS
25.331.In addition, filter
coefficient and interval time
must be considered in
setting this parameter.
This parameter specifies the
interval time between
detection of event 1C and
sending of the measurement
report. The value of this
parameter is associated with
slow fading. If this
parameter is set to a greater
value, the probability of
incorrect decision becomes
low; however, the handover
algorithm becomes slow in
responding to signal change.
The time-to-trigger
mechanism is introduced for
RNC TrigTime1C Event 1C Triggering Delay the following purposes:
- reducing the number of
wrong event reports caused
by burst signals,
- preventing the ping-pong
handover,
- reducing the impact of
shadow fading on event
decisions.
Setting an appropriate
interval time effectively
reduces the average number
of handovers and the
number of wrong
handovers, preventing
unnecessary handovers.
Interval at which event 1A is
reported after the reporting
mode is changed to
periodical reporting.
Generally, event 1A is
reported only once. To avoid
the loss of measurement
reports, the UE sets the
mode of reporting event 1A
to periodical if the cell
reporting event 1A is not
Event 1A to Periodical
Cell ReportIntervalfor1A Report Period added to the active set in a
specified period of time.
Event 1A is reported for
"PeriodMRReportNumfor1A
" times at the interval
specified by this parameter.
If the mode of reporting
event 1A is set to
"NON_PERIODIC_REPORT",
the UE cannot change the
event 1A reporting mode to
periodical.
Interval at which event 1A is
reported after the reporting
mode is changed to
periodical reporting.
Generally, event 1C is
reported only once. To avoid
the loss of measurement
reports, the UE set the
mode of reporting event 1C
to periodical if the cell
reporting event 1C is not
Event 1C to Periodical
Cell ReportIntervalfor1C Report Period added to the active set in a
specified period of time.
Event 1C is reported for
"PeriodMRReportNumfor1C
" times at the interval
specified by this
parameter.If the mode of
reporting event 1C is set to
"NON_PERIODIC_REPORT",
the UE cannot change the
event 1C reporting mode to
periodical.

This parameter specifies the


hysteretic value for event
1C. The value of this
parameter is associated with
the slow fading, and it can
be used to reduce ping-pong
Cell HystFor1C 1C Hysteresis handovers and incorrect
handovers. For details on
the definition of this
parameter, see 3GPP TS
25.331.In addition, filter
coefficient and interval time
must be considered in
setting this parameter.
This parameter specifies the
interval time between
detection of event 1C and
sending of the measurement
report. The value of this
parameter is associated with
slow fading. If this
parameter is set to a greater
value, the probability of
incorrect decision becomes
low; however, the handover
algorithm becomes slow in
responding to signal change.
The time-to-trigger
mechanism is introduced for
Cell TrigTime1C Event 1C Triggering Delay the following purposes:
- reducing the number of
wrong event reports caused
by burst signals,
- preventing the ping-pong
handover,
- reducing the impact of
shadow fading on event
decisions.
Setting an appropriate
interval time effectively
reduces the average number
of handovers and the
number of wrong
handovers, preventing
unnecessary handovers.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
Ec/No for CS services. For CS
services, if the inter-
frequency reporting mode is
Inter-freq CS Target set to "EVENT_TRIGGER",
this parameter is used to set
Cell TargetFreqCsThdEcN0 Frequency Trigger Ec/No the criterion for triggering
THD
event 2B. That is, event 2B
can be triggered when the
quality of the target
frequency is higher than this
threshold. If the inter-
frequency reporting mode is
set to "PERIODIC_TRIGGER",
this parameter is used for
handover decision.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
Ec/No for HSPA services.For
HSPA services, if the inter-
frequency reporting mode is
set to "EVENT_TRIGGER",
Inter-freq HSPA Target
Cell TargetFreqHThdEcN0 Frequency Trigger Ec/No this parameter is used to set
the criterion for triggering
THD event 2B. That is, event 2B
can be triggered when the
quality of the target
frequency is higher than this
threshold. If the inter-
frequency reporting mode is
set to "PERIODIC_TRIGGER",
this parameter is used for
handover decision.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
Ec/No for non-HSPA services
in PS domain.For non-HSPA
services in PS domain, if the
inter-frequency reporting
mode is set to
Inter-freq R99 PS Target "EVENT_TRIGGER", this
Cell TargetFreqR99PsThdEcN0 Frequency Trigger Ec/No
THD parameter is used to set the
criterion for triggering event
2B. That is, event 2B can be
triggered when the quality
of the target frequency is
higher than this threshold. If
the inter-frequency
reporting mode is set to
"PERIODIC_TRIGGER", this
parameter is used for
handover decision.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
RSCP for CS services. For CS
services, if the inter-
frequency reporting mode is
set to "EVENT_TRIGGER",
Inter-freq CS Target this parameter is used to set
Cell TargetFreqCsThdRscp Freqency Trigger RSCP THD the criterion for triggering
event 2B. That is, event 2B
can be triggered when the
quality of the target
frequency is higher than this
threshold. If the inter-
frequency reporting mode is
set to "PERIODIC_TRIGGER",
this parameter is used for
handover decision.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
RSCP for HSPA services. For
HSPA services, if the inter-
frequency reporting mode is
set to "EVENT_TRIGGER",
this parameter is used to set
the criterion for triggering
event 2B. That is, event 2B
can be triggered when the
quality of the target
Inter-freq HSPA Target
Cell TargetFreqHThdRscp Freqency Trigger RSCP THD frequency is higher than this
threshold. If the inter-
frequency reporting mode is
set to "PERIODIC_TRIGGER",
this parameter is used for
handover decision. After
handover, to prevent ping-
pong handover, the inter-
frequency measurement
should not be started again.
That is, this parameter is
usually set greater than the
start threshold for event 2D
or equal to the threshold of
event 2F.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
RSCP for non-HSPA services
in PS domain.For non-HSPA
services in PS domain, if the
inter-frequency reporting
mode is set to
Inter-freq R99 PS Target "EVENT_TRIGGER", this
Cell TargetFreqR99PsThdRscp
Frequency Trigger RSCP THD parameter is used to set the
criterion for triggering event
2B. That is, event 2B can be
triggered when the quality
of the target frequency is
higher than this threshold. If
the inter-frequency
reporting mode is set to
"PERIODIC_TRIGGER", this
parameter is used for
handover decision.
This parameter specifies the
Layer 3 filter coefficient for
the inter-frequency
measurement
This parameter has the
same physical significance
and measurement model as
the layer 3 filter coefficient
for the intra-frequency
Inter-frequency Measure measurement. The
Cell InterFreqFilterCoef
Filter Coeff difference is that the report
period of the inter-
frequency measurement is
480 ms while the report
period of the intra-
frequency measurement is
200 ms. In practice, the
setting of this parameter can
be adjusted according to
performance statistics.

L3 filtering coefficient for


event 2D or 2F
measurement.
The parameter has the same
physical meaning and
measurement model as the
inter-frequency L3 filter
coefficient. The reporting
Cell FilterCoefOf2D2F 2D/2F Filter Coefficient period is 480 ms. For
specific analysis, see the
intra-frequency L3 filter
coefficient and inter-
frequency L3 filter
coefficient. For details about
this parameter, see 3GPP TS
25.331.
L3 filter coefficient for inter-
RAT measurement.
The parameter has the same
physical meaning and
measurement model as the
inter-frequency L3 filter
coefficient. The reporting
Cell InterRATFilterCoef Inter-RAT Filter Coefficient period is 480 ms. For
specific analysis, see the
intra-frequency L3 filter
coefficient and inter-
frequency L3 filter
coefficient. For details about
this parameter, see 3GPP TS
25.331.

When the switch is on, the


RNC is allowed to initiate
HO_INTER_RAT_CS_OUT_S HoSwitch inter-frequency measure
RNC (HO_INTER_RAT_CS_OUT_S
WITCH WITCH) control and the CS inter-RAT
hard handover from the 3G
network to the 2G network.

When the switch is on, the


RNC is allowed to initiate
HO_INTER_RAT_PS_OUT_S HoSwitch(HO_INTER_RAT_P inter-frequency measure
RNC
WITCH S_OUT_SWITCH) control and the PS inter-RAT
hard handover from the 3G
network to the 2G network.
WCDMA cell.
This specifies the offset of
the measurement value of
the neighboring GSM cell
signal quality. This
parameter is used for RSSI
measurement. The offset is
subtracted from the
neighboring cell
measurement value before
cell reselection.
In cell reselection algorithm,
this parameter is used for
moving the border of a cell.
Content: During cell
selection or resection, the
larger the value of the
parameter, the smaller the
Cell Qoffset1sn Qoffset1sn probability of selecting
inter-RAT neighboring cells.
The smaller the value of the
parameter, the larger the
probability of selecting
inter-RAT neighboring cells.
This parameter can be
configured by the network
planner according to reality.
For details, refer to 3GPP TS
25.331.
As for the impact on
network performance:
The larger the value of the
parameter, the lower the
probability of selecting
neighboring cells. The
smaller the value the
Maximum number of cells in
an active set. This parameter
is used to achieve the
balance between the signal
quality in the SHO area and
the system performance. If
more cells are in the active
set, a user can obtain a
greater macro diversity gain;
the intra-frequency
interference is smaller. In
this case, however, the user
occupies resources of
several cells. This increases
the amount of data to be
Cell MaxCellInActiveSet MaxCellInActiveSet processed and lowers the
system performance. To
reduce intra-frequency
interference, it is
recommended that the
number of cells in the active
sets should be increased in
the hot-spot and micro cells,
where the signals are
complicated. For the cell
that provides high speed
services, the decrease in
cells in the active set can
reduce the consumption of
system resources.
measurement value is added
with the hysteresis value.
The measurement hysteresis
aims to prevent the ping-
pong effect of the cell
reselection, which is caused
by the slow fading when the
UE is on the edge of the cell.
The ping-pong effect may
trigger frequent location
updates (idle mode), URA
updates (URA_PCH), or cell
updates (CELL_FACH,
CELL_PCH), and thus
increase the load of network
signaling and the
consumption of UE
batteries. Set a proper
Cell IdleQhyst1s IdleQhyst1s measurement hysteresis to
reduce as much as possible
effect of the slow fading as
well as ensuring timely cell
updates of the UE.
According to the CPICH RSCP
emulation report of inter-
frequency hard handovers,
the measurement hysteresis
ranges 4 dBm to 5 dBm and
is set to 4 dBm by default
when the slow fading
variance is 8 dB and the
relative distance is 20 m. In
the cells where the slow
fading variance is low and
the average moving speed
of UEs is high, for example
serving cell involves in cell
selection after the
measurement value is added
with the hysteresis value.
The measurement hysteresis
aims to prevent the ping-
pong effect of the cell
reselection, which is caused
by the slow fading when the
UE is on the edge of the cell.
The ping-pong effect may
trigger frequent location
updates (idle mode), URA
updates (URA_PCH), or cell
updates (CELL_FACH,
CELL_PCH), and thus
increase the load of network
Cell IdleQhyst2s IdleQhyst2s signaling and the
consumption of UE
batteries. Set a proper
measurement hysteresis to
reduce as much as possible
effect of the slow fading as
well as ensuring timely cell
updates of the UE.
According to the CPICH RSCP
emulation report of inter-
frequency hard handovers,
the measurement hysteresis
ranges 4 dBm to 5 dBm and
is set to 4 dBm by default
when the slow fading
variance is 8 dB and the
relative distance is 20 m. In
the cells where the slow

Periodical location update is


implemented by MS through
the location update
procedure. 0: The periodical
RNC T3212 T3212
update procedure is not
used. This parameter is valid
only when [CN domain ID] is
set as CS_DOMAIN.
CN domain specific
Discontinuous Reception
RNC DrxCycleLenCoef DrxCycleLenCoef (DRX) cycle length
coefficient broadcast on
SIB1 and used by UEs in Idle
Mode.

Offset of the measured


CPICH RSCP used for cell
reselection when the UE is
in idle mode. In a cell
reselection procedure, the
Cell IdleQoffset1sn IdleQoffset1sn RNC subtracts this offset
from the measured CPICH
RSCP of a neighboring cell
and then ranks all
neighboring cells. For
details, see 3GPP TS 25.304.

Offset of the measured


CPICH Ec/No used for cell
reselection when the UE is
in idle mode. In a cell
reselection procedure, the
Cell IdleQoffset2sn IdleQoffset2sn RNC subtracts this offset
from the measured CPICH
Ec/No of a neighboring cell
and then ranks all
neighboring cells.
Offset of the measured
CPICH RSCP used for cell
reselection when the UE is
in idle mode. In a cell
reselection procedure, the
Cell IdleQoffset1sn IdleQoffset1sn RNC subtracts this offset
from the measured CPICH
RSCP of a neighboring cell
and then ranks all
neighboring cells. For
details, see 3GPP TS 25.304.

Offset of the measured


CPICH Ec/No used for cell
reselection when the UE is
in idle mode. In a cell
reselection procedure, the
Cell IdleQoffset2sn IdleQoffset2sn RNC subtracts this offset
from the measured CPICH
Ec/No of a neighboring cell
and then ranks all
neighboring cells.

Difference between the


System Frame Number (SFN)
and NodeB Frame Number
(BFN) of the NodeB which
the cell belongs to. It is
Cell Tcell Tcell recommended that Tcell of
difference cells under one
NodeB should be unique.
For detailed information of
this parameter, refer to
3GPP TS 25.433.
ID of a cell. For detailed
Cell CellId CellId information about this
parameter, see 3GPP TS
25.401.

{412,437,462,487,512,537,5
62,587,612,637,662,687}
Band3
General frequencies: [1162-
1513]
Additional frequencies:
none
Band4
General frequencies: [1537-
1738]
Additional frequencies:
{1887, 1912, 1937, 1962,
1987, 2012, 2037, 2062,
2087}
Band5
General frequencies: [4357-
4458]
Additional frequencies:
Cell UARFCNDownlink UARFCNDownlink
{1007, 1012, 1032,1037,
1062, 1087}
Band6
General frequencies: [4387-
4413]
Additional frequencies:
{1037, 1062}
Band7
General frequencies: [2237-
2563]
Additional frequencies:
{2587, 2612, 2637, 2662,
2687, 2712, 2737, 2762,
2787, 2812, 2837, 2862,
2887, 2912}
Band8
General frequencies: [2937-
3088]
Hysteresis for triggering
event 2D.
When
"InterFreqReportMode" is
set to
PERIODICAL_REPORTING,
the hysteresis in active set
quality measurement is used
to prevent the ping-pong
reporting of event 2D
(triggered when the
estimated quality of the
frequency in use is lower
than the threshold) and
event 2F (triggered when
Cell HystFor2D HystFor2D the estimated quality of the
frequency in use is higher
than the threshold). Event
2D is used to enable the
compression mode and
event 2F is used to disable
the compression mode.To
prevent the compression
mode from being frequently
enabled and disabled, you
can set "Hystfor2D" and
"Hystfor2F" to be greater
than their recommended
values according to the
statistics of the ping-pong
inter-frequency handover.
Hysteresis for triggering
event 2F.
When
"InterFreqReportMode" is
set to
PERIODICAL_REPORTING,
the hysteresis in active set
quality measurement is used
to prevent the ping-pong
reporting of event 2D
(triggered when the
estimated quality of the
frequency in use is lower
than the threshold) and
event 2F (triggered when
Cell HystFor2F HystFor2F the estimated quality of the
frequency in use is higher
than the threshold). Event
2D is used to enable the
compression mode and
event 2F is used to disable
the compression mode.To
prevent the compression
mode from being frequently
enabled and disabled, you
can set "Hystfor2D" and
"Hystfor2F" to be greater
than their recommended
values according to the
statistics of the ping-pong
inter-frequency handover.
Hysteresis for triggering
event 2D.
When
"InterFreqReportMode" is
set to
PERIODICAL_REPORTING,
the hysteresis in active set
quality measurement is used
to prevent the ping-pong
reporting of event 2D
(triggered when the
estimated quality of the
frequency in use is lower
than the threshold) and
event 2F (triggered when
Cell Hystfor2D Hystfor2D the estimated quality of the
frequency in use is higher
than the threshold). Event
2D is used to enable the
compression mode and
event 2F is used to disable
the compression mode.To
prevent the compression
mode from being frequently
enabled and disabled, you
can set "Hystfor2D" and
"Hystfor2F" to be greater
than their recommended
values according to the
statistics of the ping-pong
inter-frequency handover.
Hysteresis for triggering
event 2F.
When
"InterFreqReportMode" is
set to
PERIODICAL_REPORTING,
the hysteresis in active set
quality measurement is used
to prevent the ping-pong
reporting of event 2D
(triggered when the
estimated quality of the
frequency in use is lower
than the threshold) and
event 2F (triggered when
Cell Hystfor2F Hystfor2F the estimated quality of the
frequency in use is higher
than the threshold). Event
2D is used to enable the
compression mode and
event 2F is used to disable
the compression mode.To
prevent the compression
mode from being frequently
enabled and disabled, you
can set "Hystfor2D" and
"Hystfor2F" to be greater
than their recommended
values according to the
statistics of the ping-pong
inter-frequency handover.
This parameter specifies the
interval time between
detection of event 1D and
sending of the measurement
report. The value of this
parameter is associated with
slow fading. If this
parameter is set to a greater
value, the probability of
incorrect decision becomes
low; however, the handover
algorithm becomes slow in
responding to signal change.
The time-to-trigger
mechanism is introduced for
Cell TrigTime1D TrigTime1D the following purposes:
- reducing the number of
wrong event reports caused
by burst signals,
- preventing the ping-pong
handover,
- reducing the impact of
shadow fading on event
decisions.
Setting an appropriate
interval time effectively
reduces the average number
of handovers and the
number of wrong
handovers, preventing
unnecessary handovers.
Hysteresis for triggering
event 2D.
When
"InterFreqReportMode" is
set to
PERIODICAL_REPORTING,
the hysteresis in active set
quality measurement is used
to prevent the ping-pong
reporting of event 2D
(triggered when the
estimated quality of the
frequency in use is lower
than the threshold) and
event 2F (triggered when
RNC HystFor2D HystFor2D the estimated quality of the
frequency in use is higher
than the threshold). Event
2D is used to enable the
compression mode and
event 2F is used to disable
the compression mode.To
prevent the compression
mode from being frequently
enabled and disabled, you
can set "Hystfor2D" and
"Hystfor2F" to be greater
than their recommended
values according to the
statistics of the ping-pong
inter-frequency handover.
Hysteresis for triggering
event 2F.
When
"InterFreqReportMode" is
set to
PERIODICAL_REPORTING,
the hysteresis in active set
quality measurement is used
to prevent the ping-pong
reporting of event 2D
(triggered when the
estimated quality of the
frequency in use is lower
than the threshold) and
event 2F (triggered when
RNC HystFor2F HystFor2F the estimated quality of the
frequency in use is higher
than the threshold). Event
2D is used to enable the
compression mode and
event 2F is used to disable
the compression mode.To
prevent the compression
mode from being frequently
enabled and disabled, you
can set "Hystfor2D" and
"Hystfor2F" to be greater
than their recommended
values according to the
statistics of the ping-pong
inter-frequency handover.
Hysteresis for triggering
event 2D.
When
"InterFreqReportMode" is
set to
PERIODICAL_REPORTING,
the hysteresis in active set
quality measurement is used
to prevent the ping-pong
reporting of event 2D
(triggered when the
estimated quality of the
frequency in use is lower
than the threshold) and
event 2F (triggered when
RNC Hystfor2D Hystfor2D the estimated quality of the
frequency in use is higher
than the threshold). Event
2D is used to enable the
compression mode and
event 2F is used to disable
the compression mode.To
prevent the compression
mode from being frequently
enabled and disabled, you
can set "Hystfor2D" and
"Hystfor2F" to be greater
than their recommended
values according to the
statistics of the ping-pong
inter-frequency handover.
Hysteresis for triggering
event 2F.
When
"InterFreqReportMode" is
set to
PERIODICAL_REPORTING,
the hysteresis in active set
quality measurement is used
to prevent the ping-pong
reporting of event 2D
(triggered when the
estimated quality of the
frequency in use is lower
than the threshold) and
event 2F (triggered when
RNC Hystfor2F Hystfor2F the estimated quality of the
frequency in use is higher
than the threshold). Event
2D is used to enable the
compression mode and
event 2F is used to disable
the compression mode.To
prevent the compression
mode from being frequently
enabled and disabled, you
can set "Hystfor2D" and
"Hystfor2F" to be greater
than their recommended
values according to the
statistics of the ping-pong
inter-frequency handover.
According to 3GPP TS
25.331, the filtered
measurement value is
calculated using the
following formula, where k
represents this parameter:
Fn = (1 - a) * Fn - 1 + a * Mn
a = 1/(2 ^ (k/2))
Here,
Fn: filtered measurement
result
Fn - 1: previously filtered
measurement result
Mn: latest received
measurement result from
physical layer
When a is set to 1, L3
RNC FilterCoef FilterCoef filtering is not applied.
The input measurement
value to L3 filter has been
filtered by L1 filter, where
the impact of fast fading is
almost eliminated. In this
case, smooth filtering should
be applied through L3 filter,
to eliminate the effect of
shadow fading and peaks
caused by fast fading, thus
the filtered measurement
value can reflect the
variation of the actual
measurement value, and
provide more reliable
measurement result for
event judgment.
Measurement quantity for
triggering intra-frequency
handovers. Reference
measurement quantity for a
UE to report event 1x.
For intra-frequency
handovers, CPICH Ec/No or
RSCP is used as the
measurement quantity. For
events 1A, 1B, 1C, and 1D
which adopt relative
thresholds, the
measurement quantity does
not have great impact on
the threshold values. For
event 1F which adopts
absolute threshold, the
measurement quantity
RNC IntraFreqMeasQuantity IntraFreqMeasQuantity should be set based on
actual cell conditions. If the
cell is located in the center
of the coverage area, the
main factor that affects
signal quality is intra-
frequency interference. In
this case, you are advised to
set this parameter to
CPICH_EC/NO. If the cell is
located at the edge of the
coverage area, the main
factor that affects signal
quality is the distance
between the cell and the
base station. In this case,
you are advised to set this
parameter to CPICH_RSCP.

Number of times event 1A is


reported after the reporting
mode is changed to periodic
reporting. When the
RNC PeriodMRReportNumfor1A PeriodMRReportNumfor1A number of times event 1A is
reported exceeds this
parameter value, periodic
reporting of event 1A is
disabled.

Number of times event 1C is


reported after the reporting
mode is changed to periodic
reporting. When the
RNC PeriodMRReportNumfor1C PeriodMRReportNumfor1C number of times event 1C is
reported exceeds this
parameter value, periodic
reporting of event 1C is
disabled.
According to 3GPP TS
25.331, the filtered
measurement value is
calculated using the
following formula, where k
represents this parameter:
Fn = (1 - a) * Fn - 1 + a * Mn
a = 1/(2 ^ (k/2))
Here, Fn: filtered
measurement result
Fn - 1: previously filtered
measurement result
Mn: latest received
measurement result from
physical layer
When a is set to 1, L3
filtering is not applied.
Cell IntraFreqFilterCoef IntraFreqFilterCoef The input measurement
value to L3 filter has been
filtered by L1 filter, where
the impact of fast fading is
almost eliminated. In this
case, smooth filtering should
be applied through L3 filter,
to eliminate the effect of
shadow fading and peaks
caused by fast fading, thus
the filtered measurement
value can reflect the
variation of the actual
measurement value, and
provide more reliable
measurement result for
event judgement.
Note that this parameter
Measurement quantity for
triggering intra-frequency
handovers. Reference
measurement quantity for a
UE to report event 1x.
For intra-frequency
handovers, CPICH Ec/No or
RSCP is used as the
measurement quantity. For
events 1A, 1B, 1C, and 1D
which adopt relative
thresholds, the
measurement quantity does
not have great impact on
the threshold values. For
event 1F which adopts
absolute threshold, the
measurement quantity
Cell IntraFreqMeasQuantity IntraFreqMeasQuantity should be set based on
actual cell conditions. If the
cell is located in the center
of the coverage area, the
main factor that affects
signal quality is intra-
frequency interference. In
this case, you are advised to
set this parameter to
CPICH_EC/NO. If the cell is
located at the edge of the
coverage area, the main
factor that affects signal
quality is the distance
between the cell and the
base station. In this case,
you are advised to set this
parameter to CPICH_RSCP.

Number of times event 1A is


reported after the reporting
mode is changed to periodic
reporting. When the
Cell PeriodMRReportNumfor1A PeriodMRReportNumfor1A number of times event 1A is
reported exceeds this
parameter value, periodic
reporting of event 1A is
disabled.

Number of times event 1C is


reported after the reporting
mode is changed to periodic
reporting. When the
Cell PeriodMRReportNumfor1C PeriodMRReportNumfor1C number of times event 1C is
reported exceeds this
parameter value, periodic
reporting of event 1C is
disabled.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
Ec/No for CS services. For CS
services, if the inter-
frequency reporting mode is
set to "EVENT_TRIGGER",
this parameter is used to set
RNC TargetFreqCsThdEcN0 TargetFreqCsThdEcN0 the criterion for triggering
event 2B. That is, event 2B
can be triggered when the
quality of the target
frequency is higher than this
threshold. If the inter-
frequency reporting mode is
set to "PERIODIC_TRIGGER",
this parameter is used for
handover decision.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
Ec/No for non-HSPA services
in PS domain.For non-HSPA
services in PS domain, if the
inter-frequency reporting
mode is set to
"EVENT_TRIGGER", this
RNC TargetFreqR99PsThdEcN0 TargetFreqR99PsThdEcN0
parameter is used to set the
criterion for triggering event
2B. That is, event 2B can be
triggered when the quality
of the target frequency is
higher than this threshold. If
the inter-frequency
reporting mode is set to
"PERIODIC_TRIGGER", this
parameter is used for
handover decision.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
Ec/No for HSPA services.For
HSPA services, if the inter-
frequency reporting mode is
set to "EVENT_TRIGGER",
RNC TargetFreqHThdEcN0 TargetFreqHThdEcN0 this parameter is used to set
the criterion for triggering
event 2B. That is, event 2B
can be triggered when the
quality of the target
frequency is higher than this
threshold. If the inter-
frequency reporting mode is
set to "PERIODIC_TRIGGER",
this parameter is used for
handover decision.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
RSCP for CS services. For CS
services, if the inter-
frequency reporting mode is
set to "EVENT_TRIGGER",
this parameter is used to set
RNC TargetFreqCsThdRscp TargetFreqCsThdRscp the criterion for triggering
event 2B. That is, event 2B
can be triggered when the
quality of the target
frequency is higher than this
threshold. If the inter-
frequency reporting mode is
set to "PERIODIC_TRIGGER",
this parameter is used for
handover decision.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
RSCP for non-HSPA services
in PS domain.For non-HSPA
services in PS domain, if the
inter-frequency reporting
mode is set to
"EVENT_TRIGGER", this
RNC TargetFreqR99PsThdRscp TargetFreqR99PsThdRscp
parameter is used to set the
criterion for triggering event
2B. That is, event 2B can be
triggered when the quality
of the target frequency is
higher than this threshold. If
the inter-frequency
reporting mode is set to
"PERIODIC_TRIGGER", this
parameter is used for
handover decision.
Threshold of the target
frequency for triggering
inter-frequency
measurement based on
measurement quantity of
RSCP for HSPA services. For
HSPA services, if the inter-
frequency reporting mode is
set to "EVENT_TRIGGER",
this parameter is used to set
the criterion for triggering
event 2B. That is, event 2B
can be triggered when the
quality of the target
RNC TargetFreqHThdRscp TargetFreqHThdRscp frequency is higher than this
threshold. If the inter-
frequency reporting mode is
set to "PERIODIC_TRIGGER",
this parameter is used for
handover decision. After
handover, to prevent ping-
pong handover, the inter-
frequency measurement
should not be started again.
That is, this parameter is
usually set greater than the
start threshold for event 2D
or equal to the threshold of
event 2F.

Hysteresis for triggering


event 2B.
The value of this parameter
is associated with the slow
fading. If this parameter is
set to a greater value, the
ability of resisting signal
Cell HystFor2B HystFor2B fluctuation improves and
the number of ping-pong
handovers decreases;
however, the handover
algorithm becomes slow in
responding to the signal
change and thus event 2B
may not be triggered in
time.
The parameter
WeightForUsedFreq is the
frequency weighting factor
used to calculate the quality
of the current frequency.
If this parameter is set to a
greater value, the higher
quality of the active set is
obtained. If this parameter
is set to 0, the general
quality of the active set is
considered the quality of the
best cell in this set. For
RNC WeightForUsedFreq WeightForUsedFreq details about this
parameter, see the
subsection of frequency
quality estimation in the
section of inter-frequency
measurement in 3GPP TS
25.331. This parameter is
used for event-triggered
reporting of inter-frequency
handovers for events 2D, 2F,
2B and 2C, but not used for
periodical reporting of inter-
frequency handovers.

Time delay to trigger event


2B. A UE reports an event 2B
measurement report if the
RNC TimeToTrig2B TimeToTrig2B conditions for triggering
event 2B are met and persist
during the time period
specified by this parameter.
Threshold of used frequency
quality for triggering Ec/No-
based measurement for CS
services.
When Ec/No is used as the
measurement quantity for
CS services, one of the
necessary conditions for
RNC UsedFreqCSThdEcN0 UsedFreqCSThdEcN0 triggering event 2B can be
met only when the quality of
the used frequency is lower
than the value of this
parameter. Event 2B is
triggered only when both
the necessary conditions are
met.

Threshold of used frequency


quality for triggering RSCP-
based measurement for CS
services.
When RSCP is used as the
measurement quantity for
CS services, one of the
necessary conditions for
RNC UsedFreqCSThdRSCP UsedFreqCSThdRSCP
triggering event 2B can be
met only when the quality of
the used frequency is lower
than the value of this
parameter. Event 2B is
triggered only when both
the necessary conditions are
met.
Threshold of used frequency
quality for triggering Ec/No-
based measurement for PS
non-HSPA services.
When Ec/No is used as the
measurement quantity for
PS non-HSPA services, one
RNC UsedFreqR99PsThdEcN0 UsedFreqR99PsThdEcN0 of the necessary conditions
for triggering event 2B can
be met only when the
quality of the used
frequency is lower than the
value of this parameter.
Event 2B is triggered only
when both the necessary
conditions are met.

Threshold of used frequency


quality for triggering Ec/No-
based measurement for
HSPA services.
When Ec/No is used as the
measurement quantity for
HSPA services, one of the
necessary conditions for
RNC UsedFreqHThdEcN0 UsedFreqHThdEcN0
triggering event 2B can be
met only when the quality of
the used frequency is lower
than the value of this
parameter. Event 2B is
triggered only when both
the necessary conditions are
met.
Threshold of used frequency
quality for triggering RSCP-
based measurement for PS
non-HSPA services.
When RSCP is used as the
measurement quantity for
PS non-HSPA services, one
RNC UsedFreqR99PsThdRSCP UsedFreqR99PsThdRSCP of the necessary conditions
for triggering event 2B can
be met only when the
quality of the used
frequency is lower than the
value of this parameter.
Event 2B is triggered only
when both the necessary
conditions are met.

Threshold of used frequency


quality for triggering RSCP-
based measurement for
HSPA services.
When RSCP is used as the
measurement quantity for
HSPA services, one of the
necessary conditions for
RNC UsedFreqHThdRSCP UsedFreqHThdRSCP
triggering event 2B can be
met only when the quality of
the used frequency is lower
than the value of this
parameter. Event 2B is
triggered only when both
the necessary conditions are
met.
Inter-Rat threshold and this
parameter.
The value of this parameter
is associated with the slow
fading. If this parameter is
set to a greater value, the
ability of resisting signal
fluctuation improves and
the number of ping-pong
handovers decreases;
however, the handover
algorithm becomes slow in
responding to the signal
change. If this parameter is
set to a too large value, the
cell of another RAT where
the UE needs to be handed
RNC Hystfor3A Hystfor3A over to must be of good
quality. Therefore, the
criterion for triggering the
inter-RAT handover decision
is hard to be fulfilled, and
the call drop rate increases.
The emulation result shows
that in a cell where the
average moving speed of
UEs is high (for example, a
cell that covers highways),
this parameter can be set to
a smaller value 1.5 dB,
because in the cell the
terrain is flat, barriers are
fewer, and thus the shadow
fading variation is small. In a
cell where the average
The parameter
WeightForUsedFreq is the
frequency weighting factor
used to calculate the quality
of the current frequency.
If this parameter is set to a
greater value, the higher
quality of the active set is
obtained. If this parameter
is set to 0, the general
quality of the active set is
considered the quality of the
best cell in this set. For
RNC WeightForUsedFreq WeightForUsedFreq details about this
parameter, see the
subsection of frequency
quality estimation in the
section of inter-frequency
measurement in 3GPP TS
25.331. This parameter is
used for event-triggered
reporting of inter-frequency
handovers for events 2D, 2F,
2B and 2C, but not used for
periodical reporting of inter-
frequency handovers.
Maximum number of inter-
frequency handover re-
attempts after event 2B is
reported when the
measurement control
message is valid.
If this parameter is set to a
greater value, the number of
inter-frequency handover
re-attempts increases and
the possibility of
successfully handing over
the UE to the target cell
whose load becomes normal
increases. But if the target
cell is prolonged for long
RNC AmntOfRpt2B AmntOfRpt2B time not to restore to
normal, the frequent re-
attempts may lead to
resource waste. When the
number of inter-frequency
handover re-attempts
reaches the threshold, the
RNC sends another inter-
frequency measurement
control message to allow
the UE to be handed over to
other cells of this frequency.
If the measurement control
is released, the inter-
frequency handover re-
attempt is stopped.

Sets the interval between


the failure in the inter-
RNC PeriodFor2B PeriodFor2B frequency handover
triggered by the event 2B
and the inter-frequency
handover retry.
Maximum number of
handover attempts after
inter-RAT handover
triggered by event 3A fails
on condition that
measurement control is
valid.
When this parameter value
is reached, the RNC resends
inter-frequency
RNC AmntOfRpt3A AmntOfRpt3A measurement control so
that UEs have chances to be
handed over to another cell
with the same frequency. If
measurement control is
released, handover re-
attempts are terminated.
For details about this
parameter, see 3GPP TS
25.331.

Interval between handover


attempts for event 3A.
This parameter specifies the
interval between handover
attempts for event 3A. If this
parameter is set to a smaller
value, handover attempts
increase when the inter-RAT
RNC PeriodFor3A PeriodFor3A handover fails. In this case,
the UE can be quickly
handed over to the target
cell whose load is reduced,
thus lowering the
probability of call drops.
More handover re-attempts,
however, cause the increase
in the RNC load.
The CIO value specified in
this parameter cooperates
with the neighboring cell
oriented CIO. For details
Cell CIO CIO about the meaning of this
parameter, refer to 3GPP TS
25.331 and the description
of [CIOOffset].

measurement value is added


with the hysteresis value.
The measurement hysteresis
aims to prevent the ping-
pong effect of the cell
reselection, which is caused
by the slow fading when the
UE is on the edge of the cell.
The ping-pong effect may
trigger frequent location
updates (idle mode), URA
updates (URA_PCH), or cell
updates (CELL_FACH,
CELL_PCH), and thus
increase the load of network
signaling and the
consumption of UE
Cell ConnQhyst1s ConnQhyst1s batteries. Set a proper
measurement hysteresis to
reduce as much as possible
effect of the slow fading as
well as ensuring timely cell
updates of the UE.
According to the CPICH RSCP
emulation report of inter-
frequency hard handovers,
the measurement hysteresis
ranges 4 dBm to 5 dBm and
is set to 4 dBm by default
when the slow fading
variance is 8 dB and the
relative distance is 20 m. In
the cells where the slow
fading variance is low and
the average moving speed
of UEs is high, for example
selection after the
measurement value is added
with the hysteresis value.
The measurement hysteresis
aims to prevent the ping-
pong effect of the cell
reselection, which is caused
by the slow fading when the
UE is on the edge of the cell.
The ping-pong effect may
trigger frequent location
updates (idle mode), URA
updates (URA_PCH), or cell
updates (CELL_FACH,
CELL_PCH), and thus
increase the load of network
signaling and the
consumption of UE
Cell ConnQhyst2s ConnQhyst2s batteries. Set a proper
measurement hysteresis to
reduce as much as possible
effect of the slow fading as
well as ensuring timely cell
updates of the UE.
According to the CPICH RSCP
emulation report of inter-
frequency hard handovers,
the measurement hysteresis
ranges 4 dBm to 5 dBm and
is set to 4 dBm by default
when the slow fading
variance is 8 dB and the
relative distance is 20 m. In
the cells where the slow
fading variance is low and
the average moving speed

CN domain specific
Discontinuous Reception
(DRX) cycle length
RNC DRXCycleLenCoef DRXCycleLenCoef coefficient broadcast on
SIB1 and used by UEs in Idle
Mode.
Used for calculating the
relative threshold of the soft
handover based on the
measurement report of each
cell in the active set. If this
parameter is set to a greater
value, the relative threshold
of the soft handover is
greater with the other
conditions unchanged. For
detailed information of this
parameter, see 3GPP TS
25.133. When this
parameter is set to 0, the
general quality of the active
RNC Weight Weight set is the quality of the best
cell. In this case, the relative
threshold of soft handover
depends on the related
measurement values of the
best cell in the active set.
When this parameter is set
to 1, the relative threshold
of the soft handover
depends on the equivalent
signal strength obtained
when maximum ratio
combining is performed in
the downlink of all cells in
the active set.
Cell offset used for CPICH
RSCP measurement value in
cell selection or reselection
when the UE is in connected
mode. During cell selection
or reselection, "QOffset1sn"
is the cell offset
corresponding to CPICH
RSCP, and "QOffset2sn" is
the cell offset corresponding
to CPICH Ec/No. For details
about "QOffset1sn" and
"QOffset2sn", see 3GPP TS
25.331. "QOffset1sn" and
"QOffset2sn" are used when
Cell ConnQoffset1sn ConnQoffset1sn the UE is in idle mode, while
"ConnQoffset1sn" and
"ConnQoffset2sn" are used
when the UE is in connected
mode. "ConnQoffset1sn"
and "ConnQoffset2sn" are
valid only if the SIB12
message is available. The
measured value of the
neighboring cell minus the
value of this parameter is
used for cell reselection
ranking. This parameter
needs to be set based on the
actual situation.
Cell offset used for CPICH
Ec/No measurement value
in cell selection or
reselection when the UE is
in connected mode. During
cell selection or reselection,
"QOffset1sn" is the cell
offset corresponding to
CPICH RSCP, and
"QOffset2sn" is the cell
offset corresponding to
CPICH Ec/No. For details
about "QOffset1sn" and
"QOffset2sn", see 3GPP TS
25.331. "QOffset1sn" and
"QOffset2sn" are used when
Cell ConnQoffset2sn ConnQoffset2sn the UE is in idle mode, while
"ConnQoffset1sn" and
"ConnQoffset2sn" are used
when the UE is in connected
mode. "ConnQoffset1sn"
and "ConnQoffset2sn" are
valid only if the SIB12
message is available. The
measured value of the
neighboring cell minus the
value of this parameter is
used for cell reselection
ranking. This parameter
needs to be set based on the
actual situation.
Maximum number of cells in
an active set. This parameter
is used to achieve the
balance between the signal
quality in the SHO area and
the system performance. If
more cells are in the active
set, a user can obtain a
greater macro diversity gain;
the intra-frequency
interference is smaller. In
this case, however, the user
occupies resources of
several cells. This increases
the amount of data to be
RNC MaxCellInActiveSet MaxCellInActiveSet processed and lowers the
system performance. To
reduce intra-frequency
interference, it is
recommended that the
number of cells in the active
sets should be increased in
the hot-spot and micro cells,
where the signals are
complicated. For the cell
that provides high speed
services, the decrease in
cells in the active set can
reduce the consumption of
system resources.
Cell offset used for CPICH
RSCP measurement value in
cell selection or reselection
when the UE is in connected
mode. During cell selection
or reselection, "QOffset1sn"
is the cell offset
corresponding to CPICH
RSCP, and "QOffset2sn" is
the cell offset corresponding
to CPICH Ec/No. For details
about "QOffset1sn" and
"QOffset2sn", see 3GPP TS
25.331. "QOffset1sn" and
"QOffset2sn" are used when
Cell ConnQoffset1sn ConnQoffset1sn the UE is in idle mode, while
"ConnQoffset1sn" and
"ConnQoffset2sn" are used
when the UE is in connected
mode. "ConnQoffset1sn"
and "ConnQoffset2sn" are
valid only if the SIB12
message is available. The
measured value of the
neighboring cell minus the
value of this parameter is
used for cell reselection
ranking. This parameter
needs to be set based on the
actual situation.
Cell offset used for CPICH
Ec/No measurement value
in cell selection or
reselection when the UE is
in connected mode. During
cell selection or reselection,
"QOffset1sn" is the cell
offset corresponding to
CPICH RSCP, and
"QOffset2sn" is the cell
offset corresponding to
CPICH Ec/No. For details
about "QOffset1sn" and
"QOffset2sn", see 3GPP TS
25.331. "QOffset1sn" and
"QOffset2sn" are used when
Cell ConnQoffset2sn ConnQoffset2sn the UE is in idle mode, while
"ConnQoffset1sn" and
"ConnQoffset2sn" are used
when the UE is in connected
mode. "ConnQoffset1sn"
and "ConnQoffset2sn" are
valid only if the SIB12
message is available. The
measured value of the
neighboring cell minus the
value of this parameter is
used for cell reselection
ranking. This parameter
needs to be set based on the
actual situation.

Threshold for intra-


frequency cell
measurements in connected
mode in SIB4. When the
quality (CPICH Ec/No
measured by the UE) of the
serving cell is lower than this
threshold plus the value of
Cell ConnSintrasearch ConnSintrasearch "Qqualmin" for the cell,
intra-frequency cell
measurements are started.
When this parameter is set
to 127, intra-frequency cell
measurements are
performed. For details about
this parameter, see 3GPP TS
25.304.
Threshold for inter-
frequency cell
measurements in connected
mode in SIB4. When the
quality (CPICH Ec/No
measured by the UE) of the
serving cell is lower than this
threshold plus the value of
"Qqualmin" for the cell,
Cell ConnSintersearch ConnSintersearch
inter-frequency cell
measurements are started.
When this parameter is set
to 127, inter-frequency cell
measurements are
performed. For details about
this parameter, see 3GPP TS
25.304.

Used for calculating the


relative threshold of the soft
handover based on the
measurement report of each
cell in the active set. If this
parameter is set to a greater
value, the relative threshold
of the soft handover is
greater with the other
conditions unchanged. For
detailed information of this
parameter, see 3GPP TS
25.133. When this
parameter is set to 0, the
general quality of the active
Cell Weight Weight set is the quality of the best
cell. In this case, the relative
threshold of soft handover
depends on the related
measurement values of the
best cell in the active set.
When this parameter is set
to 1, the relative threshold
of the soft handover
depends on the equivalent
signal strength obtained
when maximum ratio
combining is performed in
the downlink of all cells in
the active set.
RNC BeF2HTvmThd BeF2HTvmThd #N/A

RNC UlDchBeUpperLimitforAmr UlDchBeUpperLimitforAmr #N/A

RNC DlDchBeUpperLimitforAmr DlDchBeUpperLimitforAmr #N/A

Traffic upper limit for the


RNC EVENT4ATHD EVENT4ATHD DCH to trigger event 4A.

Whether a UE in the
CELL_PCH or URA_PCH state
preferentially performs a
state transition from
CELL_PCH or URA_PCH to
CELL_DCH or CELL_FACH
before initiating a CS
service. 1: This switch is
turned on. The RNC first
RNC CS_SETUP_P2D_SWITCH CS_SETUP_P2D_SWITCH
performs a state transition
from CELL_PCH or URA_PCH
to CELL_DCH and then
initiates the CS service. 0:
This switch is turned off. The
UE first performs a state
transition from CELL_PCH or
URA_PCH to CELL_FACH and
then initiates the CS service.

RNC PERFENH_P2D_LIMIT_ON_D PERFENH_P2D_LIMIT_ON_D #N/A


CH_LOWRATE_SWITCH CH_LOWRATE_SWITCH
Whether a PS BE service is
limited to 0 kbit/s on the
DCH after a UE that has the
PS BE service performs a
CELL_PCH/URA_PCH-to-
CELL-DCH (P2D) state
transition triggered by a CS
service setup. When this
PERFENH_CS_TRIG_PS_P2D PERFENH_CS_TRIG_PS_P2D switch is turned off, the PS
RNC
_ZERO_SWITCH _ZERO_SWITCH BE service is limited to 8
kbit/s on the DCH after the
UE performs a P2D state
transition. When this switch
is turned on, the PS BE
service is limited to 0 kbit/s
on the DCH after the UE
performs a P2D state
transition.

Estimated retransmission
rate of signaling packets
when combined services are
performed. This parameter
is used to calculate the
activation time contained in
the RB SETUP or RB RECFG
RNC PacketReTransRatio PacketReTransRatio messages in scenarios with
combined services. A large
value of this parameter
leads to long activation time.
To modify this parameter,
contact Huawei Customer
Service Center for technical
support
Whether to prohibit channel
retries for CS and PS
combined services. When
this switch is turned on,
channel retries are
DRA_CSPS_NO_PERIOD_RET DRA_CSPS_NO_PERIOD_RET
RNC RY_SWITCH RY_SWITCH prohibited for CS and PS
combined services. When
this switch is turned off,
channel retries are allowed
for CS and PS combined
services.

Switch for controlling


whether the NodeB
dynamically allocates
spreading codes (SCs) to
HSPA services based on
traffic requirements.
A new policy of allocating
SCs to HSPA services applies
under the following
conditions:
1 This switch is turned on.
2 HSDPA and HSUPA
functions are activated
before the cell is set up.
The RNC allocates SCs to HS-
SCCH, E-RGCH, and E-HICH
Cell DynHsscchAllocSwitch DynHsscchAllocSwitch based on the new policy.
The NodeB dynamically
reallocates the SCs to the
HS-PDSCH for HSPA services
based on traffic
requirements. This new
policy increases the number
of SCs available for the HS-
PDSCH to a maximum of 15,
increasing HSDPA
throughput.
If not all the preceding
conditions are met, the old
policy applies,
compromising chances of 15
SCs being available for the
HS-PDSCH.
Inter-RAT handover switch
of link stability control for
DL QoS of AMR services.
RNC DlQosAmrInterRatHoSwitch DlQosAmrInterRatHoSwitch When the parameter is set
to YES, inter-RAT handover
can be performed for AMR
services to ensure the QoS.

RNC BEDLACT1 BEDLACT1 #N/A


RNC BEULACT1 BEULACT1 #N/A

Inter-RAT handover switch


of link stability control for
UL QoS of AMR services.
RNC UlQosAmrInterRatHoSwitch UlQosAmrInterRatHoSwitch When the parameter is set
to YES, inter-RAT handover
can be performed for AMR
services to ensure the QoS.

A timer used to wait for RRC


connection setup complete
message from UE in RRC
procedure. Note: The value
range of "RrcUeRspTmr" is 1
to 10000 in the current
version. In a later version,
the value range changes into
100 to 10000. In the current
version, if you enter a value
RNC RrcUeRspTmr RrcUeRspTmr within the range of 1 to 100
including 1, this value can
still be synchronized and
issued but the system
regards the value as 5000,
the recommended value.
Therefore, you are advised
not to enter a value smaller
than 100.
A timer to RNC wait for the
RNC RBRELRSPTMR RBRELRSPTMR RB release response from
UE in the RB procedure.

Timer started by the RNC to


wait for a response from the
UE after the RNC returns a
cell update confirm or URA
update confirm message to
the UE during the cell
update or URA update
procedure. Note: The value
range of
"HoCellUpdateRspTmr" is 1
to 10000 in the current
version. In a later version,
RNC HoCellUpdateRspTmr HoCellUpdateRspTmr the value range changes into
100 to 10000. In the current
version, if you enter a value
within the range of 1 to 100
including 1, this value can
still be synchronized and
issued but the system
regards the value as 5000,
the recommended value.
Therefore, you are advised
not to enter a value smaller
than 100.
This check box controls
whether the RNC considers
the converged SIRTarget
value that is used before
radio link reconfiguration in
outer loop power control
performed after radio link
reconfiguration. If the check
box is not selected, the RNC
sends the initial SIRTarget
value used after radio link
reconfiguration to the
NodeB.If the check box is
PERFENH_RL_RECFG_SIR_C PERFENH_RL_RECFG_SIR_C selected, the RNC selects a
RNC ONSIDER_SWITCH ONSIDER_SWITCH more appropriate value
from the initial SIRTarget
value used after radio link
reconfiguration and the
converged SIRTarget value
used before radio link
reconfiguration. Then the
RNC sends the selected
value to the NodeB. Setting
of this check box takes
effect only when the
PC_RL_RECFG_SIR_TARGET_
CARRY_SWITCH check box is
selected.

Uplink bit rate threshold for


DCCC. When the maximum
uplink bit rate of a BE
service is larger than this
parameter value, the traffic-
RNC UlDcccRateThd UlDcccRateThd based uplink DCCC function
can take effect for the UE.
Otherwise, the function
cannot take effect for the
UE.
For a BE service that has a
low maximum rate, the
DCCC algorithm is not
obviously effective yet it
increases algorithm
RNC DlDcccRateThd DlDcccRateThd
processing. Thus, the traffic-
based DCCC algorithm is
applied to BE services whose
maximum DL rate is greater
than the threshold.

Bit rate threshold for low


activity. When a BE service's
data rate is decreased to the
one for DCCC and conditions
for a D2F state transition are
met, the RNC decreases the
data rate to the one for low
activity if the D2F state
transition cannot be
performed. The reason for
the failed D2F state
transition can be that the
switch for the transition to
RNC LittleRateThd LittleRateThd the CELL_FACH state is
turned off or that CS
services are going on. The
traffic measurement control
parameters and timer for
adjusting the bit rate for low
activity are the same as
those for the D2F state
transition. These parameters
and the timer can be set in
the "SET UUESTATETRANS"
and "SET
UUESTATETRANSTIMER"
commands.
Time of waiting for a RESET
ACK PDU after sending a
RESET PDU to the peer end.
This parameter is used only
Cell TIMERRST TIMERRST at the TX end of the AM RLC
entity. The TX end
retransmits the RESET PDU
to the RX end if the timer
expires.

Downlink bit rate for full


coverage. When the
maximum downlink bit rate
of a BE service is larger than
this parameter value, the
Cell DLFULLCVRRATE DLFULLCVRRATE
coverage-based downlink
DCCC function can take
effect for the UE. Otherwise,
the function cannot take
effect for the UE

whether to enable the


optimized algorithm for
HSPA UE state transition
from CELL_DCH to
CELL_FACH (also referred to
as H2F state transition).
When the switch is turned
PERFENH_H2F_OPT_SWITC PERFENH_H2F_OPT_SWITC on, the optimized H2F state
RNC transition algorithm is
H H enabled, and event 4A
measurement of traffic
volume or throughput is
added to the state transition
procedure. The added event
4A measurement prevents
an H2F state transition when
data is being transmitted.
DRD rollback enhancement
switch. When this
parameter is set to ON(ON),
the RNC continues receiving
and processing the
configuration failure
messages sent by the UE in
the source cell after the
activation time arrives
during the DRD procedure.
When this parameter is set
to OFF(OFF), the RNC uses
new configurations after the
RNC DRDROLLBACKSWITCH DRDROLLBACKSWITCH activation time arrives and
does not receive or process
the configuration failure
messages sent by the UE in
the source cell. Note: The
activation time ensures that
the UE, NodeB, and RNC use
new configurations at the
same time when the UE data
configurations stored on the
RNC side are modified. For
details, see 3G PP TS 25.331.

When the switch is turned


on, the RNC supports
rollback caused by failed
directed retry decisions
RNC_RBRECFG_DRD_FAIL_R RNC_RBRECFG_DRD_FAIL_R (DRDs) of RB
RNC
OLLBACK_SWITCH OLLBACK_SWITCH reconfiguration. When the
switch is turned off, the RNC
does not support rollback
caused by failed DRDs of RB
reconfiguration
When the switch is turned
on, the RNC supports
rollback caused by failed
DRDs of RB establishment.
RNC_RBSETUP_DRD_FAIL_R RNC_RBSETUP_DRD_FAIL_R
RNC OLLBACK_SWITCH OLLBACK_SWITCH When the switch is turned
off, the RNC does not
support rollback caused by
failed DRDs of RB
establishment

A timer to RNC wait for the


RNC RbSetupRspTmr RbSetupRspTmr RB setup response from UE
in the RB procedure. Refer

A timer to RNC wait for the


response to active set
update in soft handover
procedure. Note: The value
range of "HoAsuTmr" is 1 to
300000 in the current
version. In a later version,
the value range changes into
100 to 300000. In the
RNC HoAsuTmr HoAsuTmr current version, if you enter
a value within the range of 1
to 100 including 1, this value
can still be synchronized and
issued but the system
regards the value as 5000,
the recommended value.
Therefore, you are advised
not to enter a value smaller
than 100.
In order that the UE and
NodeB can start CM
simultaneously, the user
should predetermine the
time difference between
Compressed Mode (CM)
start time and current time.
This difference should be
based on the sum of the
time required for hardware
preparation for CM start and
RNC DeltaCFN DeltaCFN
the longer time between the
time spent on signalling
transmission from RNC to
UE and that from RNC to
NodeB. Usually it ranges 500
to 1500 ms. The radio frame
length in WCDMA system is
10 ms. Therefore, it is
recommended that this
parameter should be set
within the range 50 to 150

Whether the RNC carries an


indication to read the
system frame number (SFN)
of an intra-frequency
neighboring cell from SIB11
or SIB12. When this switch is
turned off, the RNC carries
RNC CMP_READSFN_IND_IN_SIB CMP_READSFN_IND_IN_SIB the indication not to read
_SWITCH _SWITCH the SFN of the intra-
frequency neighboring cell
from SIB11 or SIB12. When
this switch is turned on, the
RNC carries the indication to
read the SFN of the intra-
frequency neighboring cell
from SIB11 or SIB12
A timer to RNC wait for the
response to physical channel
reconfiguration in hard
handover procedure. Note:
The value range of
"HoPhychRecfgTmr" is 1 to
300000 in the current
version. In a later version,
the value range changes into
100 to 300000. In the
RNC HOPHYCHRECFGTMR HOPHYCHRECFGTMR current version, if you enter
a value within the range of 1
to 100 including 1, this value
can still be synchronized and
issued but the system
regards the value as 5000,
the recommended value.
Therefore, you are advised
not to enter a value smaller
than 100.

A timer used to wait for the


RNC RBRECFGRSPTMR RBRECFGRSPTMR RB reconfiguration response
from UE in the RB procedure
When this switch is turned
on, if a UE sets up a non-PTT
service on the DCH, the RNC
includes the Post-
verification period
information element (IE) in a
Uu message to instruct the
UE to perform concurrent
NONPTT_L1_FAST_SYNC_S NONPTT_L1_FAST_SYNC_S uplink and downlink
RNC synchronization. When this
WITCH WITCH switch is turned off, if a UE
sets up a non-PTT service on
the DCH, the RNC does not
include the Post-verification
period IE in a Uu message.
The UE first performs
downlink synchronization
and then uplink
synchronization

Wait time IE contained in


the RRC CONNECTION
REJECT message for a high-
priority RRC connection
setup request, that is, the
minimum time for which a
UE must wait before it sends
another RRC connection
setup request. An RRC
connection setup request
has a high priority only
when one of the following
RNC RrcConnRejWaitTmr RrcConnRejWaitTmr conditions is met: 1. The
value of the IE CN domain
identity contained in the
RRC CONNECTION REQUEST
message sent from the UE to
the RNC is CS domain. 2. The
cause value contained in the
RRC CONNECTION REQUEST
message is Originating
Conversational Call,
Terminating Conversational
Call, or Emergency Call
When the switch is not on, a
new initial SIRTarget value,
during radio link
reconfiguration, is based on
the converged SIRTarget
PC_RL_RECFG_SIR_TARGET_ PC_RL_RECFG_SIR_TARGET_ value of current outer loop
RNC power control. In addition,
CARRY_SWITCH CARRY_SWITCH the UL SIRTarget value is not
included in the radio link
reconfiguration messages to
the NodeB. This switch is
only valid when the OLPC
switch is ON

Duration of a CQI feedback


cycle when the UE is in the
single-RLS state. In each CQI
feedback cycle, the UE
retransmits CQI for N times
Cell CQIFbCK CQIFbCK repeatedly, where N
represents the value of CQI
repetition factor. The value
0 indicates no CQI
information sent from the
UE.

Number of CQI
retransmissions when the
UE is in the single-RLS state.
Assume that the CQI
Cell CQIReF CQIReF
repetition factor is N. The
receiver performs soft
combining on N results
before decoding.

Number of CQI
retransmissions when the
UE is in the multi-RLS state.
Assume that the CQI
Cell CQIReFforSHO CQIReFforSHO
repetition factor is N. The
receiver performs soft
combining on N results
before decoding.

RNC RSVSWITCH5(RESERVED_SW RSVSWITCH5(RESERVED_SW #N/A


ITCH_5_BIT6) ITCH_5_BIT6)
Whether the configured
type of channel that
preferably carries the
RNC SrbChlTypeRrcEffectFlag SrbChlTypeRrcEffectFlag signaling RB is effective in
the case of RRC connection
establishment.

When this switch is turned


on, the SRB of a CS RRC
connection cannot be
established on HSPA
channels. The RNC
determines whether an RRC
connection request is for a
CS service based on the RRC
connection setup cause and
the value of Domain
Indicator. For a UE of a
version earlier than Release
MAP_SRB_ON_DCH_OR_FA MAP_SRB_ON_DCH_OR_FA
RNC CH_CS_RRC_SWITCH CH_CS_RRC_SWITCH 6, the RRC connection setup
cause of CS services is
Originating Conversational
Call or Terminating
Conversational Call. For a UE
of Release 6 or a later
version, the value of Domain
Indicator must be CS and the
RRC connection setup cause
must be Originating
Conversational Call or
Terminating Conversational
Call for a CS service

When the switch is set to


OFF, a penalty is imposed on
a failed directed retry due to
any failures on the Uu
CMP_RAB_DRD_ROLLBACK_ CMP_RAB_DRD_ROLLBACK_ interface during the whole
RNC call. When the switch is set
PUNISH_SWITCH PUNISH_SWITCH to ON, no penalty is
imposed on a failed directed
retry after best cell changed.
By default, this switch is set
to OFF.
Timer for not releasing
signaling over the Iu-PS
interface when no PS RAB is
set up. After this timer
RNC IuPSRelNoRABTmr IuPSRelNoRABTmr
expires, the RNC sends a
RANAP IU RELEASE REQUEST
message to the CN.

to the RNC, the RNC


performs the following
procedure:The RNC sends a
CELL UPDATE CONFIRM
message containing physical
layer information to instruct
the UE to respond.The RNC
waits for the UE to send a
response message. If the
RNC does not receive the
message before a timer
expires, the RNC sends an
RRC RELEASE message to the
UE.The UE will respond with
one of the following
messages:UTRAN MOBILITY
INFORMATION
UE_TRB_RESET_IOT_SWITC UE_TRB_RESET_IOT_SWITC
RNC H H CONFIRM,PHYSICAL
CHANNEL
RECONFIGURATION
COMPLETE,TRANSPORT
CHANNEL
RECONFIGURATION
COMPLETE,RADIO BEARER
RECONFIGURATION
COMPLETE,RADIO BEARER
RELEASE COMPLETE.

When this switch is turned


off, after a UE in the
CELL_FACH state sends a
CELL UPDATE message with
the cause value of TRB reset
to the RNC, the RNC does
not wait for the UE to send a
Whether the RNC processes
the first and the
retransmitted RRC
connection setup requests
from a UE as one RRC
connection setup request.
RELIABILITY_RRC_RETRANS_ RELIABILITY_RRC_RETRANS_ 1: When this switch is
RNC SWITCH SWITCH turned on, the RNC
processes the first and the
retransmitted RRC
connection setup requests
from a UE as one RRC
connection setup request.
0: This switch is turned off.

Whether the RNC


reestablishes a radio link
(RL) when it receives a CELL
UPDATE message carrying
SRB reset information.

1: This switch is turned on.


RNC UE_SRB_RESET_SWITCH UE_SRB_RESET_SWITCH The RNC does not release
the RRC connection and it
reestablishes an RL.

0: This switch is turned off.


The RNC releases the RRC
connection
Whether the RNC
reestablishes a radio link
(RL) when it detects an SRB
reset reported on Layer 2
for decreasing the number
of UE call drops 1: This
RNC SRB_RESET_RL_SETUP_SWIT SRB_RESET_RL_SETUP_SWIT switch is turned on. The RNC
CH(OptimizationSwitch) CH(OptimizationSwitch) reestablishes an RL when it
detects the SRB reset. 0:
This switch is turned off. The
RNC does not reestablish an
RL when it detects the SRB
reset.

Whether active link re-


establishment is allowed
after the radio link fails 1:
This switch is turned on.
Active link re-establishment
is allowed after the RNC
receives a RADIO LINK
FAILURE INDICATION
message and the timer used
to wait for a RADIO LINK
RLFAIL_RL_SETUP_SWITCH( RLFAIL_RL_SETUP_SWITCH( RESTORE INDICATION
RNC
OptimizationSwitch) OptimizationSwitch) message from the NodeB
expires. 0: This switch is
turned off. Active link re-
establishment is not allowed
after the RNC receives a
RADIO LINK FAILURE
INDICATION message and
the timer used to wait for a
RADIO LINK RESTORE
INDICATION message from
the NodeB expires.
Whether to trigger radio
link (RL) reestablishment
during a soft handover. 1:
This switch is turned on. A
UE sends a CELL UPDATE
message to the RNC and
subsequently the RNC
reestablishes the RL for the
UE when both of the
following conditions are
met: -The RNC is waiting for
the UE's response to the
RNC ASU_RL_RESET_SWITCH ASU_RL_RESET_SWITCH ACTIVE SET UPDATE
message. -The RNC detects
that downlink transmission
on signaling radio bearer
(SRB2) is disconnected or
the NodeB reports that all
RLs for the UE are out of
synchronization. 0: This
switch is turned off. The RNC
does not reestablish the RL
for the UE when the
preceding conditions are
met

OptimizationSwitch OptimizationSwitch
RNC #N/A
=MC_RL_RESET_SWITCH =MC_RL_RESET_SWITCH

Whether the RNC


reestablishes a radio link
(RL) when SRBs of a CS
service reset or all its RLs are
out of synchronization. 1:
RNC CS_RL_SETUP_SWITCH CS_RL_SETUP_SWITCH This switch is turned on. The
RNC reestablishes an RL in
the preceding scenario. 0:
This switch is turned off. The
RNC does not reestablish an
RL in the preceding scenario.
1: This switch is turned on.
PS services can trigger active
RNC PS_RL_SETUP_SWITCH PS_RL_SETUP_SWITCH link re-establishment. 0: This
switch is turned off. PS
services cannot trigger
active link re-establishment

1: This switch is turned on. If


there are CS services and
the last radio link fails, the
RNC waits for the radio link
to restore before the timer
RNC RL_RESTORE_SWITCH RL_RESTORE_SWITCH T313 expires. 0: This switch
is turned off. If there are CS
services and the last radio
link fails, the RNC waits for
the radio link to restore
before the original timer
expires.

When this switch is turned


on, a UE sends the RNC a
Cell Update message with
the cause value "Radio Link
Failure" and the RNC
reestablishes the radio link
for the UE under the
following conditions: The UE
has not responded to the
Physical Channel
RNC PHY_RECFG_REEST_SWITCH PHY_RECFG_REEST_SWITCH Reconfiguration message.
The RNC detects interrupted
downlink transmission on
SRB2 or the NodeB reports
that all radio links of the UE
are out of synchronization.
When this switch is turned
off, the RNC does not
reestablish the radio link for
the UE under the preceding
conditions
PROCESSSWITCH4: PROCESSSWITCH4:
RNC RB_SETUP_RL_REEST_SWITC RB_SETUP_RL_REEST_SWITC #N/A
H H

When this switch is turned


on, the RNC deletes the
existing Iur radio links for
the UE during the RNC
performing radio link
RNC IUR_RL_REEST_SWITCH IUR_RL_REEST_SWITCH reestablishment. When this
switch is turned off, the RNC
does not delete the existing
Iur radio links during the
RNC performing radio link
reestablishment

When the switch is turned


on, the RNC considers that it
has received an ACTIVE SET
UPDATE COMPLETE
message during soft
handover procedure after
ASU_RSP_TIMEOUT_HANDL ASU_RSP_TIMEOUT_HANDL the message has expired.
RNC
E_SWITCH E_SWITCH When the switch is turned
off, RABs are directly
released during soft
handover procedure after
the ACTIVE SET UPDATE
COMPLETE message has
expired.

When the switch is turned


on, SRBs are reestablished
during cell update
procedure with the "RL
CELLUPT_RLFAILURE_SRBRE CELLUPT_RLFAILURE_SRBRE Failure" cause value. When
RNC ESTAB_SWITCH ESTAB_SWITCH the switch is turned off,
SRBs are not reestablished
during cell update
procedure with the "RL
Failure" cause value
When this switch is turned
on, the RNC reestablishes a
radio link (RL) for the UE if
the RNC detects a traffic
radio bearer (TRB) reset at
layer 2 (L2) under the
TRB_RESET_RL_REEST_SWIT TRB_RESET_RL_REEST_SWIT following conditions: UE is in
RNC CH CH CELL_DCH state and UE is
not in any signaling
procedure. UE has only one
PS RAB. When this switch is
turned off, the RNC does not
reestablish the radio link for
the UE under the preceding
conditions

When this switch is turned


on, the RNC reestablishes a
radio link (RL) for the UE
during a PS radio bearer (RB)
release procedure under the
following conditions: The
RNC detects a signaling
radio bearer (SRB) reset at
layer 2 (L2) or all uplink RLs
for the UE are out of
synchronization upon
RNC RB_REL_RL_REEST_SWITCH RB_REL_RL_REEST_SWITCH expiration of the RL Restore
timer or UE has no response
to RNC after RNC sends UE a
RADIO BEARER RELEASE
message. The UE has both
CS RAB and PS RAB. The UE
is in CELL_DCH state. When
this switch is turned off, the
RNC does not reestablish
the radio link for the UE
under the preceding
conditions.
When this switch is turned
on, the RNC reestablishes a
radio link (RL) for the UE
during a radio bearer (RB)
setup CELL_DCH-to-
CELL_DCH (D2D) procedure
under the following
conditions: The RNC detects
a signaling radio bearer
(SRB) reset at layer 2 (L2) or
all uplink RLs for the UE are
out of synchronization upon
expiration of the RL Restore
timer and the UE has
RB_SETUP_ENHANCE_RL_RE RB_SETUP_ENHANCE_RL_RE received the RADIO BEARER
RNC EST_SWITCH EST_SWITCH SETUP message. The UE has
no response to the RNC
after the RNC sends UE a
RADIO BEARER SETUP
message. The switch
RB_SETUP_RL_REEST_SWITC
H under "PROCESSSWITCH4"
in the "SET
URRCTRLSWITCH" command
should be turned on. When
this switch is turned off, the
RNC does not reestablish
the radio link for the UE
under the preceding
conditions.

RNC CSRLReEstCellUpdateTmr CSRLReEstCellUpdateTmr #N/A

Time the RNC waits for a cell


PSRLReEstCellUpdateTmr(SE PSRLReEstCellUpdateTmr(SE update message from a UE
RNC T USTATETIMER) T USTATETIMER) with only ongoing PS
services after the RNC turns
off the radio transmitter
Timer 313. T313 stars when
a UE detects N313
successive "out of sync"
indications from Layer 1 and
stops when the UE detects
N315 successive "in sync"
indications form Layer 1.
RNC T313 T313
When T313 expires, the
radio link setup fails. The
protocol-defined default
value is 3. The value of this
parameter is contained in
SIB1 messages.

Maximum number of
successive "out of sync"
indications received from
Layer 1. The protocol-
RNC N313 N313
defined default value is 20.
The value of this parameter
is contained in SIB1
messages
synchronization failure are
fulfilled and only RBs
associated with T314 exist.
T314 stops when the cell
update procedure is
completed. The protocol-
defined default value is 12.
When a UE in the CELL_DCH
state experiences a radio
link synchronization failure,
the UE starts T315 or T314
and sends a CELL UPDATE
message. Before T314 or
T315 expires, the UE
resends the CELL UPDATE
message if radio link
reconfiguration through the
CELL UPDATE CONFIRM
RNC T314 T314 message fails. This provides
an opportunity for radio link
reconfiguration, which is
associated with T302 and
N302. It is recommended
that T314 be set to a value
greater than the product of
T302 and N302. The smaller
the value of T314 is, the
higher the call drop rate of
the corresponding service is.
When T314 expires and the
UE is performing a CS
service, or T315 expires and
the UE is performing a PS
service, the RNC releases
the RRC connection. The
value of this parameter is
synchronization failure are
fulfilled and only RBs
associated with T315 exist.
T315 stops when the cell
update procedure is
completed. The protocol-
defined default value is 180.
When a UE in the CELL_DCH
state experiences a radio
link synchronization failure,
the UE starts T315 or T314
and sends a CELL UPDATE
message. Before T314 or
T315 expires, the UE
resends the CELL UPDATE
message if radio link
reconfiguration through the
CELL UPDATE CONFIRM
RNC T315 T315 message fails. This provides
an opportunity for radio link
reconfiguration, which is
associated with T302 and
N302. It is recommended
that T315 be set to a value
greater than the product of
T302 and N302. The smaller
the value of T315 is, the
higher the call drop rate of
the corresponding service is.
When T314 expires and the
UE is performing a CS
service, or T315 expires and
the UE is performing a PS
service, the RNC releases
the RRC connection. The
value of this parameter is
Timer 302. T302 starts when
a UE sends a CELL
UPDATE/URA UPDATE
message and stops when
the UE receives a CELL
UPDATE CONFIRM/URA
UPDATE CONFIRM message.
When T302 expires, the UE
resends a CELL UPDATE/URA
UPDATE message if the
RNC T302 T302 value of the counter V302 is
smaller than or equal to that
of the parameter N302. If
the value of V302 is larger
than that of N302 when
T302 expires, the UE enters
the idle mode. The protocol-
defined default value is
4000. The value of this
parameter is contained in
SIB1 messages

Maximum number of
retransmissions of the CELL
UPDATE/URA UPDATE
message. The protocol-
RNC N302 N302
defined default value is 3.
The value of this parameter
is contained in SIB1
messages.

Maximum number of
successive "in sync"
indications received from
Layer 1 after T313 starts.
RNC N315 N315 The protocol-defined default
value is 1. The value of this
parameter is contained in
SIB1 messages.
Number of times of
successive in-sync
indications required for
starting the radio link failure
timer. When the radio link
set is in the synchronized
state, the NodeB starts the
timer after it receives
successive out-of-sync
indications of the number
defined by "NOutsyncInd".
The NodeB shall stop and
Cell NOutsyncInd NOutsyncInd reset the timer after
receiving successive in-sync
indications of the number
defined by "NInsyncInd".
"TRlFailure" specifies the
length of the timer. When
the timer expires, the
NodeB triggers the radio link
failure process, and
indicates which radio link
set is out-of-sync.
Number of times of
successive in-sync
indications required for the
NodeB to trigger the radio
link recovery process. The
radio link set remains in the
initial state until it has
received a number (the
number is defined by
"NInsyncInd") of successive
in-sync indications from L1,
Cell NInsyncInd NInsyncInd and then the NodeB triggers
the radio link recovery
process, which indicates
that the radio link set has
been synchronized. Once
the radio link recovery
process is triggered, the
radio link set is considered
to be in the synchronized
state. In the radio link
maintenance process.

Radio link failure timer


duration. When the radio
link set is in the
synchronized state, the
NodeB starts the timer after
it receives successive out-of-
sync indications of the
number defined by
NOutsyncInd. The NodeB
shall stop and reset the
Cell TRLFailure TRLFailure timer after receiving
successive in-sync
indications of the number
defined by NInsyncInd.
When the timer expires, the
NodeB triggers the radio link
failure process, and
indicates which radio link
set is out-of-sync.
When it is checked, RNC will
RNC FAST_DORMANCY_SWITCH FAST_DORMANCY_SWITCH apply FAST DORMANCY
function

When the switch is turned


on, for UEs in the CELL_PCH
state, the RNC triggers the
P2D procedure if the RNC
receives from a UE a cell
update message in which
the value of the IE "Traffic
volume indicator" is TRUE,
RNC_TVM_BASED_P2D_SWI RNC_TVM_BASED_P2D_SWI or if the dynamic traffic
RNC TCH TCH volume measured on the CN
meets a specified threshold.
When the switch is turned
off, the RNC does not trigger
the P2D procedure based on
the value of the IE "Traffic
volume indicator" or on the
dynamic traffic volume
measured on the CN

RRC connection admission


control (CAC) mode. When
this parameter is set to
LOOSE_CAC, the original
RRC admission threshold
remains unchanged. When
RRCCeCodeCacChoice RRCCeCodeCacChoice this parameter is set to
Cell STRICT_CAC, the RRC
admission threshold equals
the RAB admission threshold
plus the RRC admission
threshold offset for the
corresponding service.
The system performs CAC
based on the usage state of
NODEB_CREDIT_CAC_SWITC NODEB_CREDIT_CAC_SWITC NodeB credit. When the
RNC H H NodeB's credit is not
enough, the system rejects
new access requests.

Control Cell Credit


admission control algorithm.
Only when
NODEB_CREDIT_CAC_SWITC
H which is set by the SET
Cell CRD_ADCTRL CRD_ADCTRL
UCACALGOSWITCH
command and this switch
are on,the Cell Credit
admission control algorithm
is valid.

Control HSDPA UU Load


admission control algorithm.
This swtich does not work
Cell HSDPA_UU_ADCTRL HSDPA_UU_ADCTRL
when uplink is beared on
HSUPA and downlink is
beared on HSDPA.

Control HSUPA UU Load


admission control algorithm.
This switch does not work
Cell HSUPA_UU_ADCTRL HSUPA_UU_ADCTRL when uplink is beared on
HSUPA and downlink is
beared on HSDPA.
The algorithms with the
above values represent are
as follow:
ALGORITHM_OFF: Disable
uplink call admission control
algorithm.
ALGORITHM_FIRST: The load
factor prediction algorithm
Cell NBMUlCacAlgoSelSwitch NBMUlCacAlgoSelSwitch will be used in uplink CAC.
ALGORITHM_SECOND: The
equivalent user number
algorithm will be used in
uplink CAC.
ALGORITHM_THIRD: The
loose call admission control
algorithm will be used in
uplink CAC.

The algorithms with the


above values represent are
as follow:
ALGORITHM_OFF: Disable
downlink call admission
control algorithm.
ALGORITHM_FIRST: The load
factor prediction algorithm
will be used in downlink
Cell NBMDlCacAlgoSelSwitch NBMDlCacAlgoSelSwitch
CAC.
ALGORITHM_SECOND: The
equivalent user number
algorithm will be used in
downlink CAC.
ALGORITHM_THIRD: The
loose call admission control
algorithm will be used in
downlink CAC.
Delay time of decision for
HSUPA happy bit. If all the
buffered user data can be
transmitted at the current
rate during the time
Cell HBDelaycnd HBDelaycnd
specified by this parameter,
the HSUPA happy bit is set
to happy; otherwise, the
HSUPA happy bit is set to
unhappy.

RNC RETRYCAPABILITY:TTI_2MS RETRYCAPABILITY:TTI_2MS #N/A

RETRYCAPABILITY:SRB_OVER RETRYCAPABILITY:SRB_OVER
RNC _HSUPA _HSUPA #N/A

Interval between reception


Cell TimeToTrigForPrdInterFreq TimeToTrigForPrdInterFreq of periodical reports and
triggering of the inter-
frequency handover.

Interval between reception


of periodical reports and
Cell TimeToTrigForPrdInterFreq TimeToTrigForPrdInterFreq triggering of the inter-
frequency handover.
measurement is stopped. In
addition, the compressed
mode (if activated) should
be deactivated. The value 0
indicates that the inter-RAT
measurement timer is not
started.
The following factors should
be considered during
setting:
This parameter is designed
to prevent that the UE being
in compressed mode for a
long time when the
handover criteria are not
fulfilled, because the UE
does not move or is moving
in a low speed. If the
Cell InterRATMeasTime InterRATMeasTime compressed mode is
maintained for a long time,
the service quality is
adversely affected and the
total available capacity of
the system decreases.
Most inter-RAT handovers
can be finished within 60s.
Impact on network
performance:
If the parameter is set to a
smaller value, the UE cannot
finish inter-RAT handover. If
the parameter is set to a
larger value, the
compressed mode will not
be disabled, thus affecting
UE measurement. In actual
inter-RAT handover criteria
and the neighboring GSM
cell is verified, an inter-RAT
handover is triggered.
The criterion for triggering
inter-RAT handover is as
follows:
Mother_RAT + CIO >=
Tother_RAT + H/2
If the quality of the
neighboring GSM cell meets
the preceding criterion, the
RAN starts the trigger timer.
After the timer expires, the
RAN makes inter-RAT
handover decision. The
length of the trigger timer is
called the time to trigger
Cell TimeToTrigForVerify TimeToTrigForVerify verified GSM cell.
This parameter and the
hysteresis are used together
to prevent incorrect
decisions caused by signal
jitters during inter-RAT
handover decisions.
Considering that the UE is
on the edge of the system,
this parameter should be set
to a comparatively low
value. In situations where a
GSM cell is verified, the
performance of the GSM cell
is generally regarded as
good. In this case, the
parameter can be set to 0,
which indicates that the
since the UE behavior may
be unknown.
The GSM RSSI measurement
period is 480 ms. Therefore,
the inter-RAT periodical
reporting interval should be
longer than 480 ms. If the
periodical reporting interval
is excessively high, the
handover decision time will
be long, and handovers will
be slow.
The adjustment should be
made according to the
configured GSM RSSI
measurement compressed
mode sequence. According
InterRATPeriodReportInterv InterRATPeriodReportInterv to the current configured
Cell al al GSM RSSI measurement
compressed mode
sequence, the RSSI
measurement of eight GSM
cells can be finished in 480
ms. Therefore, the RSSI
measurement of 16 GSM
cells can be finished in 1000
ms. According to 3GPP
specifications, the number
of inter-RAT neighboring
cells should not exceed 32.
Therefore, the parameter
value can be set to 2000 ms
if the number of neighboring
GSM cells exceeds 16.
The setting of this
parameter has impact on
Length of the timer to avoid
ping-pong handovers
between 2G and 3G
networks.
When a UE in the CS domain
is handed over from a 2G
network to a 3G network,
the system increases the
hysteresis used for event 3A
to prevent the ping-pong
handover between the 2G
Cell InterRATPingPongTimer InterRATPingPongTimer network and the 3G
network in the period
specified by this parameter.
During the penalty time, the
previous periodical report
will be changed to the event
3A report. The value 0
indicates that the system
does not take measures to
avoid ping-pong handover
between 2G and 3G
networks.

After a UE fails to be
handed over to a 2G cell
during an inter-RAT
handover, the RNC forbids
the UE to attempt a
PERFENH_INTERRAT_PENAL PERFENH_INTERRAT_PENAL
RNC TY_50_SWITCH TY_50_SWITCH handover to the 2G cell in a
certain period. When the
switch is set to ON, the
period is 50s. When the
switch is set to OFF, the
period is 30s.
Determines whether
preemption is supported.
When this switch is enabled,
the RNC allows privileged
users or services to preempt
cell resources from the
users or services with the
RNC PreemptAlgoSwitch PreemptAlgoSwitch preempted attributes and
lower priority in the case of
cell resource insufficiency.
When the switch is disabled,
the RNC terminates the
service for the user due to
the failure in cell resource
application

Whether RRC connection


requests for CS services
preempt resources for PS
services when cell resources
are insufficient.When this
switch is turned on, CS
services preempt resources
occupied by PS services to
PREEMPT_ENH_CSRRC_PRE PREEMPT_ENH_CSRRC_PRE access the cell, if RRC
RNC
EMPT_PS_SWITCH EMPT_PS_SWITCH connection requests for CS
services fail due to
insufficient cell
resources.When this switch
is turned off, RRC
connection requests for CS
services cannot initiate a
preemption for resources
occupied by PS services
Whether CS access requests
preempt resources for PS
services when cell resources
are insufficient.When this
switch is turned on, CS
services preempt resources
occupied by PS services to
PREEMPT_ENH_CSRAB_PRE PREEMPT_ENH_CSRAB_PRE
RNC EMPT_PS_SWITCH EMPT_PS_SWITCH access the cell, if CS access
requests fail due to
insufficient cell
resources.When this switch
is turned off, CS access
requests cannot initiate a
preemption for resources
occupied by PS services

Whether preemption is
allowed when the CPU load
is high. When this switch is
turned on, a user checks the
CPU load when attempting
to preempt other users'
resources due to insufficient
PREEMPT_ENH_CPU_HIGHL PREEMPT_ENH_CPU_HIGHL cell resources and cannot
RNC
OAD_CTRL_SWITCH OAD_CTRL_SWITCH preempt other users'
resources when the CPU
usage is higher than 70%.
When this switch is turned
off, the user does not
consider the CPU load when
preempting other users'
resources

Cell UlRRCCeResvSf UlRRCCeResvSf #N/A


Cell DlRRCCeCodeResvSf DlRRCCeCodeResvSf #N/A
Cell RRCCacChoice RRCCacChoice #N/A
Cell RTRRCCacThdOffset RTRRCCacThdOffset #N/A
Cell NRTRRCCacThdOffset NRTRRCCacThdOffset #N/A
Cell OtherRRCCacThdOffset OtherRRCCacThdOffset #N/A
RNC PagingSwitch PagingSwitch #N/A
Whether to activate the PS
BE RRC preemption
algorithm for a cell. When
this switch is turned on, if
the conversational services
(including the calling and
called parties) fail to be
allocated resources at the
RNC PsBERrcPreemptVulnerable PsBERrcPreemptVulnerable RRC connection setup phase
or RAB setup phase and fail
to preempt resources of
other services (such as PS
RABs), the conversational
services can preempt the
resources of PS BE services
having only the RRC
connections

Cell CS_SETUP_OPT_SWITCH CS_SETUP_OPT_SWITCH #N/A

Whether a UE can preempt


resources occupied by PS BE
services after the cell
resource admission fails
under the following
conditions: -The UE moves
from CELL_PCH or URA_PCH
RNC CsP2DPreemptSwitch CsP2DPreemptSwitch to CELL_DCH (P2D). -The
RRC_CELL_UPDATE message
sent by the UE contains the
cause value of Originating
Conversational Call or
Terminating Conversational
Call

Cell QrxlevminExtSup QrxlevminExtSup #N/A


Cell DeltaQrxlevmin DeltaQrxlevmin #N/A

RNC COUNT_CS_REC_IU_REL_C COUNT_CS_REC_IU_REL_C #N/A


MD_SWITCH MD_SWITCH
Type of the channel for
carrying PS BE services and
the initial service access rate
in scenarios of CS+PS BE
combined services.
OFF: The channel bearing
type and initial access rate
of PS BE services are not
limited.
DCH0K: PS BE services are
carried over the DCH in the
uplink and downlink and the
initial access rate of the PS
BE services is 0 kbit/s.
DCH8K: PS BE services are
carried over the DCH in the
RNC BeInitBitrateTypeforCsPs BeInitBitrateTypeforCsPs uplink and downlink and the
initial access rate of the PS
BE services is 8 kbit/s.
DCH8KHSDPA: PS BE
services are carried over the
DCH in the uplink and the
initial access rate of the PS
BE services is 8 kbit/s. In the
downlink, the channel for
carrying PS BE services and
the initial access rate are not
limited.
When this parameter is set
to DCH0K, DCH8K, or
DCH8KHSDPA, periodic
retries of a UE are
prohibited
Whether downlink PS
services of CS and PS
combined services are
carried on DCHs. When this
switch is turned off, the RNC
determines the channel
MAP_CSPS_PS_DL_USE_DC MAP_CSPS_PS_DL_USE_DC carrying the downlink PS
RNC
H_SWITCH H_SWITCH services of the CS and PS
combined services. When
this switch is turned on and
CS and PS combined services
existing, the downlink PS
services must be carried on
DCHs.

Whether the RNC prohibits


the PS RB reconfiguration
triggered by an uplink or
downlink event 4A
measurement report if the
status is congested as
indicated by Combined
Service Power Resource
Congest State. When this
switch is turned off, the RNC
allows the PS RB
RNC PERFENH_CSPS_NO_RATEU PERFENH_CSPS_NO_RATEU reconfiguration triggered by
P_IN_CONJ_SWITCH P_IN_CONJ_SWITCH
an event 4A measurement
report. When this switch is
turned on, the RNC prohibits
the PS RB reconfiguration
triggered by an uplink or
downlink event 4A
measurement report if the
status is congested as
indicated by Combined
Service Power Resource
Congest State
Uplink acceleration load
threshold factor for
combined services.
If the uplink power of a cell
is larger than or equal to the
product of this factor and
the value of the
"UlLdrTrigThd" parameter
RNC MultiRabUlDcccLoadFactor MultiRabUlDcccLoadFactor (in the "ADD UCELLLDM"
command), the uplink
power resources of the
combined services are
congested.
Otherwise, the uplink power
resources of the combined
services are not congested

Downlink acceleration load


threshold factor for
combined services.
If the downlink power of a
cell is larger than or equal to
the product of this factor
and the value of the
"DlLdrTrigThd" parameter
RNC MultiRabDlDcccLoadFactor MultiRabDlDcccLoadFactor (in the "ADD UCELLLDM"
command), the downlink
power resources of the
combined services are
congested.
Otherwise, the downlink
power resources of the
combined services are not
congested
Whether the following two
functions can be enabled:If
the current rate of the PS BE
service is 0 kbit/s and event
4A triggered-DCCC service
rate increasing fails for a
CS+PS BE combined service,
the RNC does not release
the PS BE service after a
timer set by the
"ZeroRateUpFailToRelTimerL
en" parameter in the "SET
DRA_PS_STATE_TRANS_WH DRA_PS_STATE_TRANS_WH
RNC EN_CS_REL_SWITCH EN_CS_REL_SWITCH UCOIFTIMER" command
expires. A UE processing a
CS+PS BE combined service
immediately transits to the
CELL_FACH state if the CS
service is released and the
PS BE service has no data
transmission. ON: This
switch is turned on. The
preceding functions can be
enabled. OFF: This switch is
turned off. The preceding
functions are disabled.

Whether to activate the


combined-service-specific
algorithm for the CQI
feedback period. The CQI
feedback period is equal to
the value of
PC_CQI_CYCLE_BASE_CS_PL PC_CQI_CYCLE_BASE_CS_PL "CQIFBckBaseCsCombServ"
RNC in the "SET UHSDPCCH"
US_PS_SWITCH US_PS_SWITCH command when this switch
is turned on and the UE is
processing CS and PS
services. In addition, CS
services and PS services are
carried over the DCH and
HSDPA, respectively.
Combined-service-specific
CQI feedback period for a
cell where UEs are
RNC CQIFBckBaseCsCombServ CQIFBckBaseCsCombServ processing CS services
carried over the DCH and PS
services carried over the
HSDPA

Combined-service-specific
CQI feedback period for a
cell where UEs are
CELL CQIFBckBaseCsCombServ CQIFBckBaseCsCombServ processing CS services
carried over the DCH and PS
services carried over the
HSDPA

RNC RRC_CONN_SETUP_OPT_SW RRC_CONN_SETUP_OPT_SW #N/A


ITCH ITCH
UM_RRCRELCMP_RLDEL_DE UM_RRCRELCMP_RLDEL_DE
RNC LAY_SWITCH LAY_SWITCH #N/A

Whether to use the


PERFENH_HSUPA_TTI_RECF PERFENH_HSUPA_TTI_RECF
RNC G_PROC_OPT_SWITCH G_PROC_OPT_SWITCH optimized TTI switching
algorithm for BE services

Whether the RNC sends a


SECURITY MODE REJECT
message to the CN when a
RNC SECU_CU_CROSS_SWITCH SECU_CU_CROSS_SWITCH
cell update procedure is
initiated during a security
mode control procedure.

Whether the RNC proceeds


with CS service setups
involving state transitions
RNC AMR_F2D_OVERLAP_CELLU AMR_F2D_OVERLAP_CELLU from CELL_FACH to
PT_SWITCH PT_SWITCH
CELL_DCH if the UEs in
question report cell updates
during the setup procedure.

When the switch is on, the


RNC is allowed to initiate
inter-frequency measure
HO_INTER_FREQ_HARD_HO HO_INTER_FREQ_HARD_HO control or the load-based
RNC
_SWITCH _SWITCH inter-frequency hard
handover upon the
handover decision on inter-
frequency load.
RNC SrbChlType SrbChlType #N/A

RNC MAP_HSUPA_TTI_2MS_SWI MAP_HSUPA_TTI_2MS_SWI When the switch is on, 2 ms


TCH TCH TTI is supported for HSUPA.
RNC MAP_HSUPA_TTI_2MS_SWI MAP_HSUPA_TTI_2MS_SWI When the switch is on, 2 ms
TCH TCH TTI is supported for HSUPA.

Downlink GBR of the BE and


DlGBR DlGBR PTT services. GBR is the
(当 (当 minimum bit rate that the
TRAFFICCLASS=INTERACTIVE TRAFFICCLASS=INTERACTIVE system can guarantee for
RNC /BACKGROUND, /BACKGROUND, the admitted services. When
BEARTYPE=HSPA, BEARTYPE=HSPA, "BearType" is set to R99, the
USERPRIORITY=GOLD/SILVE USERPRIORITY=GOLD/SILVE parameter value is not
R/COPPER时) R/COPPER时) greater than D384.

UlGBR UlGBR Uplink GBR of the BE and


(当 (当 PTT services. GBR is the
TRAFFICCLASS=INTERACTIVE TRAFFICCLASS=INTERACTIVE minimum bit rate that the
RNC /BACKGROUND, /BACKGROUND, system can guarantee for
the admitted services. When
BEARTYPE=R99, BEARTYPE=R99, "BearType" is set to R99, the
USERPRIORITY=GOLD/SILVE USERPRIORITY=GOLD/SILVE
parameter value is not
R/COPPER时) R/COPPER时) greater than D384

Cell CSRABCacOptSwitch CSRABCacOptSwitch #N/A


Whether to activate CE-
based user preemption on
the NodeB side. If this
switch is turned on, the
PREEMPT_ENH_NODEB_PRE PREEMPT_ENH_NODEB_PRE BSC6900 sends the NodeB a
RNC
EMPT_CE_SWITCH EMPT_CE_SWITCH user list containing users
that can be preempted. The
NodeB selects users for
preemption based on the
consumed CEs.

When this switch is turned


on, the RNC supports
rollback caused by failed
hard handovers of CS AMR
speech services. It is
recommended that the
timer T312 be set to 1
second (SET
AMR_HHO_FAIL_ROLLBACK AMR_HHO_FAIL_ROLLBACK UCONNMODETIMER:
RNC _SWITCH _SWITCH T312=1;) before turning on
this switch. If the timer T312
is not set to 1 second, AMR
noise will occur on some
UEs. When this switch is
turned off, the RNC does not
support rollback caused by
failed hard handovers of CS
AMR speech services,
leading to call drops

Upper limit of random


access back-off delay. For
details about this
cell NB01max NB01max parameter, see 3GPP TS
25.331 and 3GPP TS 25.214
protocols

Lower limit of random


access back-off delay. For
details about this
cell NB01min NB01min parameter, see 3GPP TS
25.331 and 3GPP TS 25.214
protocols
Length of the timer for the
inter-frequency
measurement.
If the inter-frequency
handover is not performed
before this timer expires,
the inter-frequency
measurement is stopped
and the compression mode
is disabled (if enabled
CELL InterFreqMeasTime InterFreqMeasTime before). The value 0
indicates that this timer is
not to be started.
This parameter is used to
prevent the long duration of
the inter-frequency
measurement state
(compression mode) due to
unavailability of a target cell
that meets the handover
criteria.

RNC IUCSRELNORABTMR IUCSRELNORABTMR #N/A

FACH_USER_NUM_NOT_CT FACH_USER_NUM_NOT_CT
CELL RL RL #N/A

RNC RESERVED_SWITCH_2_BIT8 RESERVED_SWITCH_2_BIT8 #N/A

Cell ERGCHEHICHCODENUM ERGCHEHICHCODENUM #N/A

RNC PHYCHRECFG_ENH_RL_REES PHYCHRECFG_ENH_RL_REES #N/A


T_SWITCH T_SWITCH
RBRECFG_ENH_RL_REEST_S RBRECFG_ENH_RL_REEST_S
RNC WITCH WITCH #N/A

RB_RECFG_RL_REEST_SWIT RB_RECFG_RL_REEST_SWIT
RNC CH CH #N/A

NON_DCCC_RBRECFG_RL_R NON_DCCC_RBRECFG_RL_R
RNC #N/A
EEST_SWITCH EEST_SWITCH
RNC SMC_RL_REEST_SWITCH SMC_RL_REEST_SWITCH #N/A
PSINACTTMRFORFSTDRMDC PSINACTTMRFORFSTDRMDC
RNC H H #N/A
RNC T323 T323 #N/A

PSINACTTMRFORPREFSTDR PSINACTTMRFORPREFSTDR
RNC M M #N/A
Whether the compressed
mode (CM) can coexist with
the HSUPA service. If this
parameter is set to Permit:
1. the RNC can enable the
CM for HSUPA services. 2.
The HSUPA services can be
enabled when the CM is
enabled. If this parameter is
set to Limited: 1. the CM for
HSUPA services can be
enabled only after the E2D
(E-DCH to DCH) channel
switch. 2. The HSUPA
services cannot be enabled
RNC HsupaCMPermissionInd HsupaCMPermissionInd when the CM is enabled. If
this parameter is set to
BasedonUECap, the RNC
determines whether CM can
be enabled for HSUPA
services and whether HSUPA
services can be enabled
when the CM is enabled by
considering the UE
capability.
This switch is used for the
compatibility of the HSUPA
terminals that do not
support CM when HSUPA is
enabled.

RNC 基于SDU时延的F2D 基于SDU时延的F2D #N/A

CMP_F2D_RLC_ONESIDE_RE CMP_F2D_RLC_ONESIDE_RE
RNC BUILD_SWITCH BUILD_SWITCH #N/A

CMP_D2F_RLC_ONESIDE_RE CMP_D2F_RLC_ONESIDE_RE
RNC #N/A
BUILD_SWITCH BUILD_SWITCH

RNC 关闭2ms周期重试
P-CPICH Ec/N0 on RACH更新
RNC
优化

设置“No有效信号质量报
RNC
告时的ECN0假定值”

HSUPA用户TTI重配置流程
RNC
优化

PERFENH_HRNTI_OPT_SWIT
RNC
CH

Cell HspaPower HspaPower


CMP_DRD_SRBOVERH_SWIT CMP_DRD_SRBOVERH_SWIT
RNC
CH CH

PERFENH_SRB_OVER_HSUP PERFENH_SRB_OVER_HSUP
RNC
A_TTI10_SWITCH A_TTI10_SWITCH
RNC E2FTHROUTHD E2FTHROUTHD

RNC BEF2ETVMTHD BEF2ETVMTHD

RNC FASTDORMANCYF2DHTVMT FASTDORMANCYF2DHTVMT


HD HD

RNC BEF2DTVMTIMETOTRIG BEF2DTVMTIMETOTRIG


RNC BEF2HTVMTIMETOTRIG BEF2HTVMTIMETOTRIG
RNC BEF2ETVMTIMETOTRIG BEF2ETVMTIMETOTRIG
RNC D2FTVMPTAT D2FTVMPTAT
RNC BEH2FTVMPTAT BEH2FTVMPTAT
RNC E2FTHROUPTAT E2FTHROUPTAT
RNC E2FTHROUMEASPERIOD E2FTHROUMEASPERIOD
RNC InactF2PstateTransTimer InactF2PstateTransTimer

RNC_RB_SCRI_NOT_DROP_S RNC_RB_SCRI_NOT_DROP_S
RNC
WITCH WITCH

RNC GTPU_ERR_IND_DEF_SWITC GTPU_ERR_IND_DEF_SWITC


H H

RNC T309 T309

IRATHO_CNT_CORRECT_SWI IRATHO_CNT_CORRECT_SWI
RNC TCH TCH

RNC MaccPageRepeatTimes MaccPageRepeatTimes

RNC PS_RAB_DOWNSIZING_SWIT PS_RAB_DOWNSIZING_SWIT


CH CH

RNC PsInactTmrForFstDrmFach PsInactTmrForFstDrmFach


This parameter defines the
Cell Qqualmin Min Quality Level CPICH Ec/No access
threshold of the cell
This parameter defines the
CPICH RSCP access threshold
of the cell.This parameter is
the minimum required RX
level that corresponds to
Cell Qrxlevmin Min RX level CPICH RSCP. The UE can
camp on the cell only when
the measured CPICH RSCP is
greater than the value of
this parameter

Offset of the measured


CPICH RSCP used for cell
reselection when the UE is
in idle mode. In a cell
reselection procedure, the
Cell IdleQoffset1sn IdleQoffset1sn RNC subtracts this offset
from the measured CPICH
RSCP of a neighboring cell
and then ranks all
neighboring cells. For
details, see 3GPP TS 25.304
Offset of the measured
CPICH Ec/No used for cell
reselection when the UE is
in idle mode. In a cell
IdleQoffset2sn reselection procedure, the
Cell IdleQoffset2sn
RNC subtracts this offset
from the measured CPICH
Ec/No of a neighboring cell
and then ranks all
neighboring cells

It is set according to the


topographic feature.
This parameter is used for
the inter-RAT handover
decision in combination with
the neighboring cell
oriented CIO. The larger the
sum, the higher the
handover priority of the
GSM cell. The smaller the
sum, the lower the
handover priority of the
Cell CIO Cell Individual Offset
GSM cell. The parameter is
generally set to 0.
As for the impact on
network performance:
The larger the value of the
parameter is, the easier it is
to be handed over to the
GSM network. The smaller
the value of the parameter
is, the harder it is to be
handed over to the GSM
network

The CIO value specified in


this parameter cooperates
with the neighboring cell
Cell oriented Cell Individual oriented CIO. For details
Cell CIO Offset about the meaning of this
parameter, refer to 3GPP TS
25.331 and the description
of [CIOOffset]
This parameter specifies the
neighboring cell oriented
Cell Individual Offset (CIO).
The sum of the value of this
parameter, the value of the
cell oriented CIO, and the
actual measurement
quantity is used for the
event evaluation of the UE
or used for the handover
decision procedure on the
RNC side. In a handover
algorithm, this parameter is
used for moving the border
of a cell. In the case of an
event-based intra-frequency
measurement or inter-RAT
Neighboring Cell Oriented measurement, the UE
Cell CIOOffset CIO determines whether to
trigger an event according to
the sum of the value of this
parameter, the value of the
cell oriented CIO, and the
actual measurement
quantity. The UE does not
consider the value of this
parameter when evaluating
an inter-frequency
measurement event.
In the case of a periodical
inter-frequency
measurement or inter-RAT
measurement, the RNC
determines whether to
initiate a handover
according to the sum of the

Cell individual offset (CIO) of


neighboring GSM cells. The
value of this parameter
together with the value of
Neighboring Cell-Oriented the CIO parameter in the
Cell CIOOffset CIO
"ADD UEXT2GCELL"
command determine
whether to perform a
handover. For details, see
3GPP TS 25.331
Cell offset used for CPICH
RSCP measurement value in
cell selection or reselection
when the UE is in connected
mode. During cell selection
or reselection, "QOffset1sn"
is the cell offset
corresponding to CPICH
RSCP, and "QOffset2sn" is
the cell offset corresponding
to CPICH Ec/No. For details
about "QOffset1sn" and
"QOffset2sn", see 3GPP TS
25.331. "QOffset1sn" and
"QOffset2sn" are used when
Cell ConnQoffset1sn ConnQoffset1sn the UE is in idle mode, while
"ConnQoffset1sn" and
"ConnQoffset2sn" are used
when the UE is in connected
mode. "ConnQoffset1sn"
and "ConnQoffset2sn" are
valid only if the SIB12
message is available. The
measured value of the
neighboring cell minus the
value of this parameter is
used for cell reselection
ranking. This parameter
needs to be set based on the
actual situation
Cell offset used for CPICH
Ec/No measurement value
in cell selection or
reselection when the UE is
in connected mode. During
cell selection or reselection,
"QOffset1sn" is the cell
offset corresponding to
CPICH RSCP, and
"QOffset2sn" is the cell
offset corresponding to
CPICH Ec/No. For details
about "QOffset1sn" and
"QOffset2sn", see 3GPP TS
25.331. "QOffset1sn" and
Cell ConnQoffset2sn ConnQoffset2sn "QOffset2sn" are used when
the UE is in idle mode, while
"ConnQoffset1sn" and
"ConnQoffset2sn" are used
when the UE is in connected
mode. "ConnQoffset1sn"
and "ConnQoffset2sn" are
valid only if the SIB12
message is available. The
measured value of the
neighboring cell minus the
value of this parameter is
used for cell reselection
ranking. This parameter
needs to be set based on the
actual situation

Cell individual offset for the


GSM cell.
This parameter is used for
decision making for the
inter-RAT handover. A larger
Neighboring Cell-Oriented value of the parameter
Cell CIOOffset CIO indicates the higher the
handover priority of the
GSM cell. A smaller the
value of the parameter
indicates the lower the
handover priority of the
GSM cell.
MML Command Use Base line Formula

ADD UCELLCAC SF32(SF32)

Huawei E///
ADD UCELLACCESSSTRICT NOT_BARRED RESERVED 0
NOT_RESERVED 1

ADD UCELLACCESSSTRICT NOT_BARRED


ADD UCELLACCESSSTRICT NOT_BARRED

ADD UCELLACCESSSTRICT NOT_BARRED


ADD UCELLACCESSSTRICT NOT_BARRED

ADD UCELLACCESSSTRICT NOT_BARRED


ADD UCELLACCESSSTRICT NOT_BARRED

ADD UCELLACCESSSTRICT NOT_BARRED


ADD UCELLACCESSSTRICT NOT_BARRED

ADD UCELLACCESSSTRICT NOT_BARRED


ADD UCELLACCESSSTRICT NOT_BARRED

ADD UCELLACCESSSTRICT NOT_BARRED


ADD UCELLACCESSSTRICT NOT_BARRED

ADD UCELLACCESSSTRICT NOT_BARRED


ADD UCELLACCESSSTRICT NOT_BARRED

ADD UCELLACCESSSTRICT NOT_BARRED


ADD UCELLACCESSSTRICT NOT_BARRED

(HW)
MaxTargetUlLoadFactor =
Min [90%, Max ((1-1 / 10 ^
(eulMaxOwnUuLoad / 100)),
(1-1 / 10 ^
(eulMaxRotCoverage /
ADD UCELLHSUPA 75 100)))], if the result of the
mapping values greater than
or equal 83 %, you need to
synchronize modify HW
parameter MOD UCELLCAC:
CELLID = xxx, UlCellTotalThd
= 91;

ADD UCELLCAC 95
ADD UCELLCAC 64

ADD UCELLCAC 20
ADD UBCH -20 use E/// value

ADD UCHPWROFFSET -7 use E/// value

ADD UCHPWROFFSET -6 use E/// value

If the setting is greater than


E /// maxFach1Power
HUAWEI baseline, then use
E /// value; otherwise
HUAWEI baseline (FACH
surface mapping signaling
channel maximum
transmitting power, HW side
corresponding SIGRBIND =
TRUE).
ADD UFACH 10 If the setting is greater than
E /// maxFach2Power
HUAWEI baseline, then use
E /// value; otherwise
HUAWEI baseline (mapped
user plane FACH channel
maximum transmitting
power, HW side
corresponding SIGRBIND =
FALSE).
ADD UPCH -20 use E/// value

ADD UPSCH -50 E///

ADD USSCH -50 use E/// value

ADD UPRACHBASIC 20 use E/// value

ADD UPRACHBASIC 2 use E/// value


ADD UPRACHBASIC -20 use E/// value

powerOffsetPpm =
powerOffsetPpm (ADD
UPRACHTFC command CTFC
= 1 and CTFC = 0, two CTFC
In signaling transmission powerOffsetPpm
mode, set PowerOffsetPpm corresponding maps in the
ADD UPRACHTFC to -3; in service transmission original network the same
mode, set PowerOffsetPpm value)
to -2. Note: The relocation project
in the production of the
script, based on a script RNC
baseline, RMV UPRACHTFC,
then ADD UPRACHTFC.
[HW]
HsPdschMPOConstEnum =
Round [([E ///]
maximumTransmissionPowe
r - primaryCpichPower -
ADD UCELLHSDPA 2.5dB hsMeasurementPowerOffse
t) / 10], the nearest values.
Such as 6.1, taken in
accordance with 6.0, 5.4
taken in accordance with
5.5. Step 0.5

E/// HUAWEI
SET UHSDPCCH D2
X DX

SET UCORRMALGOSWITCH 0
E/// HUAWEI
ADD UCNDOMAIN ALLOWED 1 ALLOWED
0 NOT_ALLOWED

E/// HUAWEI
ADD UCNDOMAIN MODE2 0 MODE1
1 MODE2

ADD UCELLALGOSWITCH No

ADD UCELLALGOSWITCH No

ADD UCELLALGOSWITCH No

ADD UCELLALGOSWITCH No

ADD UCELLALGOSWITCH No
ADD UCELLALGOSWITCH No

ADD UCELLALGOSWITCH No

ADD UCELLALGOSWITCH E_F_DPCH_OFF

Huawei E///
ADD UCELLHSDPA Automatic Automatic 1
Manual 0

ADD UCELLHSDPA 4 use E/// value


ADD UCELLHSDPA 5 use E/// value

ADD UCELLHSDPA 5 use E/// value

ADD URACH 3 use E/// value


HUAWEI E///
INFINITY 0
D5 1
D10 2
SET UCONNMODETIMER D30 D30 3
D60 4
D120 5
D360 6
D720 7
SET USTATETIMER 11000

SET UFRC D64 [HUAWEI]DlBeTraffInitBitrat


e=min{[E///]dlPrefRate,D32}
[HUAWEI]UlBeTraffInitBitrat
SET UFRC D64 e=min{[E///]ulPrefRate,D16}
SET URRCESTCAUSE

SET UCORRMALGOSWITCH 0

E/// HUAWEI
ADD UCELLSETUP 0 0 FALSE
1 TRUE
D1024 BEF2DTVMTHD
SET UUESTATETRANS D256 D2F2PTVMTHD

SET URRCTRLSWITCH 0
SET UCORRMALGOSWITCH 0

SET UCORRMALGOSWITCH 0
IF [E///]qRxLevMin (MO
Class
Name:vsDataExternalGsmCe
ll)==100,
[HUAWEI]qRxLevMin=([E///]
qRxLevMin (MO Class
ADD U2GNCELL -50 Name:vsDataUtranCell)
+115)/2-58;
ELSE
[HUAWEI]qRxLevMin=([E///]
qRxLevMin (MO Class
Name:vsDataExternalGsmCe
ll) + 115)/2 - 58
ADD UCELLSELRESEL 1 use E/// value
ADD UCELLSELRESEL -18 use E/// value

ADD UEXT3GCELL -18 use E/// value


ADD UINTERFREQNCELL -18
IF [E///]qRxLevMin (MO
Class
Name:vsDataExternalGsmCe
ll)==100,
[HUAWEI]qRxLevMin=([E///]
qRxLevMin (MO Class
ADD UINTERFREQNCELL -58 Name:vsDataUtranCell)
+115)/2-58;
ELSE
[HUAWEI]qRxLevMin=([E///]
qRxLevMin (MO Class
Name:vsDataExternalGsmCe
ll) + 115)/2 - 58
E/// HUAWEI
ADD UCELLSELRESEL 5 X=0 127
X!=0 [(X-1)*2-32]/2
E/// HUAWEI
ADD UCELLSELRESEL 4 X=0 127
X!=0 [(X-1)*2-32]/2
E/// HUAWEI
ADD UCELLSELRESEL 2 X=0 127
X!=0 X/2

[HUAWEI]TimeToTrig2D =
ADD D(min([E///]timeToTrigger2
UCELLINTERFREQHOCOV D320 dEcno,
[E///]timeToTrigger2dRscp))
[HUAWEI]TimeToTrig2F =
ADD D1280 D(min([E///]timeToTrigger2f
UCELLINTERFREQHOCOV Ecno,
[E///]timeToTrigger2fRscp))

Use E /// <es: userLabel>:


serviceOffset2dEcno
<userLabel / es> under
Interact PS (64/64)..
If [E ///]
(usedFreqThresh2dEcno +
serviceOffset2dEcno) <- 24,
ADD then [HUAWEI]
-14
UCELLINTERFREQHOCOV InterFreqR99PsThd2DEcN0 =
-24;
Otherwise: [HUAWEI]
InterFreqR99PsThd2DEcN0 =
[E ///]
(usedFreqThresh2dEcno +
serviceOffset2dEcno)
[HUAWEI]TrigTime2D=D(mi
n([E///]timeToTrigger2dEcn
ADD UCELLINTERRATHOCOV D320 o,
[E///]timeToTrigger2dRscp))
[HUAWEI]TrigTime2F=D(min
ADD UCELLINTERRATHOCOV D1280 ([E///]timeToTrigger2fEcno,
[E///]timeToTrigger2fRscp))
E/// HUAWEI
0 D0
1 D10
2 D20
3 D40
4 D60
5 D80
6 D100
ADD UCELLINTERRATHOCOV D0 7 D120
8 D160
9 D200
10 D240
11 D320
12 D640
13 D1280
14 D2560
15 D5000
E/// HUAWEI
0 D0
1 D10
2 D20
3 D40
4 D60
5 D80
6 D100
ADD UCELLU2LTEHOCOV D0 7 D120
8 D160
9 D200
10 D240
11 D320
12 D640
13 D1280
14 D2560
15 D5000
Use <es: userLabel>:
serviceOffset2dEcno
<userLabel / es> under,
Conv CS speech 12.2,
preconfigured.
If usedFreqThresh2dEcno +
serviceOffset2dEcno <-24,
the [HUAWEI]
ADD UCELLINTERRATHOCOV -14 InterRATCSThd2DEcN0 =
-24;
Otherwise [HUAWEI]
InterRATCSThd2DEcN0 =
[E ///]
(usedFreqThresh2dEcno +
serviceOffset2dEcno)
Use <es: userLabel>:
serviceOffset2dEcno
<userLabel / es> under,
Interact PS (64/64).
If usedFreqThresh2dEcno +
serviceOffset2dEcno <-24,
the [HUAWEI]
ADD UCELLINTERRATHOCOV -15 InterRATR99PsThd2DEcN0 =
-24;
Otherwise [HUAWEI]
InterRATR99PsThd2DEcN0 =
[E ///]
(usedFreqThresh2dEcno +
serviceOffset2dEcno)
Use E /// <es: userLabel>:
serviceOffset2dRscp
<userLabel / es> under
Interact PS (64/64)..
If [E ///]
(usedFreqThresh2dRscp +
serviceOffset2dRscp) <- 115,
ADD UCELLINTERRATHOCOV -110 then [HUAWEI]
InterRATR99PsThd2DRSCP =
-115;
Otherwise: [HUAWEI]
InterRATR99PsThd2DRSCP =
[E ///]
(usedFreqThresh2dRscp +
serviceOffset2dRscp)
If [E ///] gsmThresh3a <-110,
[HUAWEI] TargetRatCsThd =
0;
If [E ///] gsmThresh3a> -48,
ADD UCELLINTERRATHOCOV 16 [HUAWEI] TargetRatCsThd =
63;
Otherwise: [HUAWEI]
TargetRatCsThd = [E ///]
gsmThresh3a + 111,
If [E ///] gsmThresh3a <-110,
[HUAWEI]
TargetRatR99PsThd = 0;
If [E ///] gsmThresh3a> -48,
ADD UCELLINTERRATHOCOV 16 [HUAWEI]
TargetRatR99PsThd = 63;
Otherwise: [HUAWEI]
TargetRatR99PsThd = [E ///]
gsmThresh3a + 111,
If [E ///] gsmThresh3a <-110,
[HUAWEI] TargetRatHThd =
0;
If [E ///] gsmThresh3a> -48,
ADD UCELLINTERRATHOCOV 16 [HUAWEI] TargetRatHThd =
63;
Otherwise: [HUAWEI]
TargetRatHThd = [E ///]
gsmThresh3a + 111,
ADD UCELLINTRAFREQHO 12 use E/// value
ADD UCELLINTRAFREQHO 12 use E/// value
ADD UCELLINTRAFREQHO 12 use E/// value
ADD UCELLINTRAFREQHO 0 use E/// value

ADD UCELLINTRAFREQHO 0 use E/// value


ADD UCELLINTRAFREQHO 8

[HUAWEI]TimeToTrig2D =
D(min([E///]timeToTrigger2
SET UINTERFREQHOCOV D320 dEcno,
[E///]timeToTrigger2dRscp))

[HUAWEI]TimeToTrig2F =
SET UINTERFREQHOCOV D1280 D(min([E///]timeToTrigger2f
Ecno,
[E///]timeToTrigger2fRscp))
使用E///
<es:userLabel>Conv. CS
speech 12.2 ,
preconfigured</es:userLabel
>下的
serviceOffset2dEcno。
如果[E///]
SET UINTERFREQHOCOV -14 (usedFreqThresh2dEcno+ser
viceOffset2dEcno)<-24,则
[HUAWEI]InterFreqCSThd2D
EcN0=-24;
否则:
[HUAWEI]InterFreqCSThd2D
EcN0=[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno)

使用E///
<es:userLabel>Conv. CS
speech 12.2 ,
preconfigured</es:userLabel
>下的
serviceOffset2dEcno。
如果[E///]
(usedFreqThresh2dEcno+ser
SET UINTERFREQHOCOV -12 viceOffset2dEcno+usedFreq
RelThresh2fEcno)<-24,则
[HUAWEI]InterFreqCSThd2F
EcN0=-24;
否则:
[HUAWEI]InterFreqCSThd2F
EcN0=[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno+usedFreq
RelThresh2fEcno)
SET UINTERFREQHOCOV -14

(EUL/HS)</es:userLabel>下
的serviceOffset2dEcno。具
体映射规则如下:
SET UINTERFREQHOCOV -14 [HUAWEI]InterFreqHThd2DE
cN0=[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno)
E/// <es:userLabel>Interact.
PS
(64/64)</es:userLabel>servi
ceOffset2dEcno。
[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno+usedFreq
RelThresh2fEcno)<-24,
SET UINTERFREQHOCOV -12
[HUAWEI]InterFreqR99PsTh
d2FEcN0=-24;

[HUAWEI]InterFreqR99PsTh
d2FEcN0=[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno+usedFreq
RelThresh2fEcno)

[HUAWEI]InterFreqHThd2FE
cN0=[E///]
SET UINTERFREQHOCOV -12
(usedFreqThresh2dEcno+ser
viceOffset2dEcno+usedFreq
RelThresh2fEcno)
使用E///
<es:userLabel>Conv. CS
speech 12.2 ,
preconfigured</es:userLabel
>下的serviceOffset2dRscp。
如果[E///]
(usedFreqThresh2dRscp+ser
SET UINTERFREQHOCOV -95 viceOffset2dRscp)<-115,则
[HUAWEI]InterFreqCSThd2D
RSCP=-115;
否则:
[HUAWEI]InterFreqCSThd2D
RSCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp)

使用E///
<es:userLabel>Conv. CS
speech 12.2 ,
preconfigured</es:userLabel
>下的serviceOffset2dRscp。
如果[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
SET UINTERFREQHOCOV -92 RelThresh2fRscp)<-113,则
[HUAWEI]InterFreqCSThd2F
RSCP=-113;
否则:
[HUAWEI]InterFreqCSThd2F
RSCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
RelThresh2fRscp)
使用E///
<es:userLabel>Interact. PS
(64/64)</es:userLabel>下的
serviceOffset2dRscp。
如果[E///]
(usedFreqThresh2dRscp+ser
SET UINTERFREQHOCOV -95 viceOffset2dRscp)<-115,则
[HUAWEI]InterFreqR99PsTh
d2DRSCP=-115;
否则:
[HUAWEI]InterFreqR99PsTh
d2DRSCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp)

如果E///禁止H异频异系统
切换(由
licence“IfIratMobilityHsdpaE
ul”控制),则
[HUAWEI]InterFreqHThd2DR
SCP=-115;
如果E///未禁止H异频异系
统切换(由
licence“IfIratMobilityHsdpaE
SET UINTERFREQHOCOV -95 ul”控制),映射策略如下:使
用E///
<es:userLabel>Interact. PS
(EUL/HS)</es:userLabel>下
的serviceOffset2dRscp。具
体映射规则如下:
[HUAWEI]InterFreqHThd2DR
SCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp)
使用E///
<es:userLabel>Interact. PS
(64/64)</es:userLabel>下的
serviceOffset2dRscp。
如果[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
SET UINTERFREQHOCOV -92 RelThresh2fRscp)<-113,则
[HUAWEI]InterFreqR99PsTh
d2FRSCP=-113;
否则:
[HUAWEI]InterFreqR99PsTh
d2FRSCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
RelThresh2fRscp)

如果E///禁止H异频异系统
切换(由
licence“IfIratMobilityHsdpaE
ul”控制),则
[HUAWEI]InterFreqHThd2FR
SCP=-115;
如果E///未禁止H异频异系
统切换(由
licence“IfIratMobilityHsdpaE
SET UINTERFREQHOCOV -92 ul”控制),映射策略如下:使
用E///
<es:userLabel>Interact. PS
(EUL/HS)</es:userLabel>下
的serviceOffset2dRscp。具
体映射规则如下:
[HUAWEI]InterFreqHThd2FR
SCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
RelThresh2fRscp)
[HUAWEI]TrigTime2D=D(mi
n([E///]timeToTrigger2dEcn
SET UINTERRATHOCOV D320 o,
[E///]timeToTrigger2dRscp))
[HUAWEI]TrigTime2F=D(min
SET UINTERRATHOCOV D1280 ([E///]timeToTrigger2fEcno,
[E///]timeToTrigger2fRscp))
SET UINTERRATHOCOV -14
使用 <es:userLabel>Conv.
CS speech 12.2 ,
preconfigured</es:userLabel
>下的
serviceOffset2dEcno,
如果
usedFreqThresh2dEcno+ser
viceOffset2dEcno+usedFreq
SET UINTERRATHOCOV -12 RelThresh2fEcno<-24,则
[HUAWEI]InterRATCSThd2FE
cN0=-24;
否则
[HUAWEI]InterRATCSThd2FE
cN0=[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno+usedFreq
RelThresh2fEcno)
SET UINTERRATHOCOV -15
如果E///禁止H异频异系统
切换(由
licence“IfIratMobilityHsdpaE
ul”控制),则
[HUAWEI]InterRATHThd2DE
cN0=-24;
如果E///未禁止H异频异系
统切换(由
licence“IfIratMobilityHsdpaE
ul”控制),映射策略如下:使
用E///
SET UINTERRATHOCOV -15 <es:userLabel>Interact. PS
(EUL/HS)</es:userLabel>下
的serviceOffset2dEcno。
如果[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno)<-24,则
[HUAWEI]InterRATHThd2DE
cN0=-24;
否则:
[HUAWEI]InterRATHThd2DE
cN0=[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno)
使用E///
<es:userLabel>Interact. PS
(64/64)</es:userLabel>下的
serviceOffset2dEcno。
如果[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno+usedFreq
SET UINTERRATHOCOV -13 RelThresh2fEcno)<-24,则
[HUAWEI]InterRATR99PsThd
2FEcN0=-24;
否则:
[HUAWEI]InterRATR99PsThd
2FEcN0=[E///]
(usedFreqThresh2dEcno+ser
viceOffset2dEcno+usedFreq
RelThresh2fEcno)
SET UINTERRATHOCOV -13
E/// <es:userLabel>Conv. CS
speech 12.2 ,
preconfigured</es:userLabel
>下的serviceOffset2dRscp。
[E///]
(usedFreqThresh2dRscp+ser
SET UINTERRATHOCOV -100 viceOffset2dRscp)<-115,则
[HUAWEI]InterRATCSThd2D
RSCP=-115;
HUAWEI]InterRATCSThd2DR
SCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp)

E/// <es:userLabel>Conv. CS
speech 12.2 ,
preconfigured</es:userLabel
>下的serviceOffset2dRscp。
[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
RelThresh2fRscp)<-113,则
SET UINTERRATHOCOV -97 [HUAWEI]InterRATCSThd2FR
SCP=-113;

[HUAWEI]InterRATCSThd2FR
SCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
RelThresh2fRscp)
SET UINTERRATHOCOV -110
如果E///禁止H异频异系统
切换(由
licence“IfIratMobilityHsdpaE
ul”控制),则
[HUAWEI]InterRATHThd2DR
SCP=-115;
如果E///未禁止H异频异系
统切换(由
licence“IfIratMobilityHsdpaE
ul”控制),映射策略如下:使
用E///
SET UINTERRATHOCOV -110 <es:userLabel>Interact. PS
(EUL/HS)</es:userLabel>下
的serviceOffset2dRscp。
如果[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp)<-115,则
[HUAWEI]InterRATHThd2DR
SCP=-115;
否则:
[HUAWEI]InterRATHThd2DR
SCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp)

使用E///
<es:userLabel>Interact. PS
(64/64)</es:userLabel>下的
serviceOffset2dRscp。
如果[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
SET UINTERRATHOCOV -107 RelThresh2fRscp)<-113,则
[HUAWEI]InterRATR99PsThd
2FRSCP=-113;
否则:
[HUAWEI]InterRATR99PsThd
2FRSCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
RelThresh2fRscp)
如果E///禁止H异频异系统
切换(由
licence“IfIratMobilityHsdpaE
ul”控制),则
[HUAWEI]InterRATHThd2FR
SCP=-115;
如果E///未禁止H异频异系
统切换(由
licence“IfIratMobilityHsdpaE
ul”控制),映射策略如下:使
用E///
<es:userLabel>Interact. PS
SET UINTERRATHOCOV -107 (EUL/HS)</es:userLabel>下
的serviceOffset2dRscp。
如果[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
RelThresh2fRscp)<-115,则
[HUAWEI]InterRATHThd2DR
SCP=-115;
否则:
[HUAWEI]InterRATHThd2DR
SCP=[E///]
(usedFreqThresh2dRscp+ser
viceOffset2dRscp+usedFreq
RelThresh2fRscp)
SET UINTERRATHOCOV 16
SET UINTERRATHOCOV 16
If [E ///] gsmThresh3a <-110,
[HUAWEI] TargetRatHThd =
0;
If [E ///] gsmThresh3a> -48,
SET UINTERRATHOCOV 16 [HUAWEI] TargetRatHThd =
63;
Otherwise: [HUAWEI]
TargetRatHThd = [E ///]
gsmThresh3a + 111,
SET UINTRAFREQHO 6
SET UINTRAFREQHO 6
SET UINTRAFREQHO 6
SET UINTRAFREQHO 12
SET UINTRAFREQHO 12
SET UINTRAFREQHO 12
SET UINTRAFREQHO 0

SET UINTRAFREQHO 0
SET UINTRAFREQHO 8

Huawei E///
D0 0
D10 1
D20 2
D40 3
D60 4
D80 5
D100 6
SET UINTRAFREQHO D320 D120 7
D160 8
D200 9
D240 10
D320 11
D640 12
D1280 13
D2560 14
D5000 15
Huawei E///
D0 0
D10 1
D20 2
D40 3
D60 4
D80 5
D100 6
SET UINTRAFREQHO D640 D120 7
D160 8
D200 9
D240 10
D320 11
D640 12
D1280 13
D2560 14
D5000 15
SET UINTRAFREQHO D640
SET UINTRAFREQHO D4000
SET UINTRAFREQHO D4000

SET UINTRAFREQHO 8
SET UINTRAFREQHO D640
ADD UCELLINTRAFREQHO D4000
ADD UCELLINTRAFREQHO D4000

ADD UCELLINTRAFREQHO 8
ADD UCELLINTRAFREQHO D640
Use <es: userLabel>:
serviceOffset2dEcno
<userLabel / es> under,
Conv CS speech 12.2,
ADD preconfigured.
UCELLINTERFREQHOCOV -12 The [HUAWEI]
TargetFreqCsThdEcN0 =
[E ///]
(NonUsedFreqThresh4_2bEc
no + serviceOffset2dEcno)
If E /// prohibit H-system
inter-frequency handover,
the proposed target cell
threshold parameter to 0dB;
If E /// allow H-system
inter-frequency switching,
use E /// value, namely:
Use <es: userLabel>:
ADD -12 serviceOffset2dEcno
UCELLINTERFREQHOCOV <userLabel / es> under,
Interact PS (EUL / HS).
The [HUAWEI]
TargetFreqHThdEcN0 =
[E ///]
(NonUsedFreqThresh4_2bEc
no + serviceOffset2dEcno)
Use <es: userLabel>:
serviceOffset2dEcno
<userLabel / es> under,
ADD Interact PS (64/64).
-12 The [HUAWEI]
UCELLINTERFREQHOCOV TargetFreqR99PsThdEcN0 =
[E ///]
(NonUsedFreqThresh4_2bEc
no + serviceOffset2dEcno)
Use <es: userLabel>:
serviceOffset2dRscp
<userLabel / es> under,
Conv CS speech 12.2,
ADD preconfigured.
UCELLINTERFREQHOCOV -92 The [HUAWEI]
TargetFreqCsThdRscp =
[E ///]
(NonUsedFreqThresh4_2bRs
cp + serviceOffset2dRscp)
If E /// prohibit H-system
inter-frequency handover,
the proposed target cell
threshold parameter to
-25dB;
If E /// allow H-system
inter-frequency switching,
use E /// value, namely:
Use <es: userLabel>:
ADD
UCELLINTERFREQHOCOV -92 serviceOffset2dRscp
<userLabel / es> under,
Interact PS (EUL / HS).
The [HUAWEI]
TargetFreqHThdRscp =
[E ///]
(NonUsedFreqThresh4_2bRs
cp + serviceOffset2dRscp)
Use <es: userLabel>:
serviceOffset2dRscp
<userLabel / es> under,
ADD Interact PS (64/64).
-92 The [HUAWEI]
UCELLINTERFREQHOCOV TargetFreqR99PsThdRscp =
[E ///]
(NonUsedFreqThresh4_2bRs
cp + serviceOffset2dRscp)
For low
speed(5km/h):Range is
D4~D6, the recommended
value is D5;
for middle
speed(50km/h):Range is
ADD D3~D4, the recommended
value is D4; use E/// value
UCELLINTERFREQHONCOV for high
speed(120km/h):Range is
D2~D4, the recommended
value is D2;
universal value:Range is
D3~D6, the recommended
value is D3.

ADD UCELLINTERRATHOCOV D3 use E/// value


ADD UCELLINTERRATHOCOV D3 use E/// value

SET UCORRMALGOSWITCH 1

SET UCORRMALGOSWITCH 1
use E/// value,
ADD U2GNCELL 0 “vsDataGsmRelation”Qoffse
t1sn。
ADD UCELLINTRAFREQHO 3 use E/// value
ADD UCELLSELRESEL 2 Huawei<==>E/2
ADD UCELLSELRESEL 1 Huawei<==>E/2

ADD UCNDOMAIN 10 use E/// value


If E /// <6, mapped to 6;
SET UFRC 6 If E ///> = 6, the direct use
of the original network value
E ///

ADD UINTERFREQNCELL 0 use E/// value,

ADD UINTERFREQNCELL 0 use E/// value,


ADD UINTRAFREQNCELL 0 use E/// value,

ADD UINTRAFREQNCELL 0 use E/// value,

Huawei E///
CHIP0 0
CHIP256 1
CHIP512 2
CHIP768 3
ADD UCELLSETUP None CHIP1024 4
CHIP1280 5
CHIP1536 6
CHIP1792 7
CHIP2048 8
CHIP2304 9
ADD UCELLSETUP None

ADD UCELLSETUP
ADD
UCELLINTERFREQHOCOV 4 use E/// value
ADD
UCELLINTERFREQHOCOV 4 use E/// value
ADD UCELLINTERRATHOCOV 4 use E/// value
ADD UCELLINTERRATHOCOV 4 use E/// value
ADD UCELLINTRAFREQHO D640
SET UINTERFREQHOCOV 4
SET UINTERFREQHOCOV 4
SET UINTERRATHOCOV 4
SET UINTERRATHOCOV 4
SET UINTRAFREQHO D3 use E/// value
SET UINTRAFREQHO CPICH_EC/NO

SET UINTRAFREQHO D16

SET UINTRAFREQHO D16


ADD UCELLINTRAFREQHO D3 use E/// value
ADD UCELLINTRAFREQHO
CPICH_EC/NO

ADD UCELLINTRAFREQHO D16

ADD UCELLINTRAFREQHO D16


SET UINTERFREQHOCOV -12
SET UINTERFREQHOCOV -12
If E /// prohibit H-system
inter-frequency handover,
the proposed target cell
threshold parameter to 0dB;
If E /// allow H-system
inter-frequency switching,
use E /// value, namely:
Use <es: userLabel>:
SET UINTERFREQHOCOV -12 serviceOffset2dEcno
<userLabel / es> under,
Interact PS (EUL / HS).
The [HUAWEI]
TargetFreqHThdEcN0 =
[E ///]
(NonUsedFreqThresh4_2bEc
no + serviceOffset2dEcno)
SET UINTERFREQHOCOV -92
SET UINTERFREQHOCOV -92
If E /// prohibit H-system
inter-frequency handover,
the proposed target cell
threshold parameter to
-25dB;
If E /// allow H-system
inter-frequency switching,
use E /// value, namely:
Use <es: userLabel>:
SET UINTERFREQHOCOV -92 serviceOffset2dRscp
<userLabel / es> under,
Interact PS (EUL / HS).
The [HUAWEI]
TargetFreqHThdRscp =
[E ///]
(NonUsedFreqThresh4_2bRs
cp + serviceOffset2dRscp)

SET UINTERFREQHOCOV 4
SET UINTERFREQHOCOV 0

SET UINTERFREQHOCOV D0
ms
SET UINTERFREQHOCOV -12

SET UINTERFREQHOCOV -92


SET UINTERFREQHOCOV -12

SET UINTERFREQHOCOV -12


SET UINTERFREQHOCOV -92

SET UINTERFREQHOCOV -92


SET UINTERRATHOCOV 4
SET UINTERRATHOCOV 0
SET UINTERFREQHOCOV 4

SET UINTERFREQHOCOV 1
SET UINTERRATHOCOV 4

SET UINTERRATHOCOV 1
HW = E / 5, the original
network parameters
ADD UCELLSETUP 0 "vsDataUtranCell" tab page
accessible.

ADD UCELLSELRESEL 2
ADD UCELLSELRESEL 1

If E /// <6, mapped to 6;


If E ///> = 6, the direct use
ADD UCNDOMAIN 6 of the original network value
E ///
SET UINTRAFREQHO 0
ADD UINTERFREQNCELL
0
ADD UINTERFREQNCELL
0
SET UINTRAFREQHO 3
ADD UINTRAFREQNCELL
0
ADD UINTRAFREQNCELL
0

ADD UCELLSELRESEL 5
4
ADD UCELLSELRESEL

ADD UCELLINTRAFREQHO 0
D1024 BEF2HTVMTHD take greater
SET UUESTATETRANS than a threshold level
R14之后:D256 D2F2PTVMTHD

SET UFRC D384

SET UFRC D384

ADD UTYPRABDCCCMC 1024

SET URRCTRLSWITCH 0

SET UCORRMPARA 0
SET UCORRMPARA 0

ADD UCELLRLACTTIME 5
SET UCORRMALGOSWITCH 0

ADD UCELLHSDPA OFF(关)


SET UQOSACT NO

SET UQOSACT RateDegrade RateDegrade


SET UQOSACT RateDegrade RateDegrade

SET UQOSACT NO

SET USTATETIMER 5000


SET USTATETIMER 5000

SET USTATETIMER 5000


SET UCORRMPARA 1

SET UDCCC D64


SET UDCCC D64

SET UDCCC D8
RAB业务索引41-93(PS域
交互和背景类各种速率的
ADD UTYPRABRLC RAB),“TRCHTYPE=TRCH
_HSDSCH,
OPPOSITETRCHTYPE=TRCH_
DCH”的 TIMERRST为D450

ADD UCELLDCCC D64

SET UCORRMPARA 0
SET UDPUCFGDATA

SET URRCTRLSWITCH ON
SET URRCTRLSWITCH 0

SET USTATETIMER 5000

SET USTATETIMER 5000


SET UCMCF 80

SET UCORRMALGOSWITCH 1
SET USTATETIMER 5000

SET USTATETIMER 5000


SET URRCTRLSWITCH 0

SET USTATETIMER 4
SET UCORRMALGOSWITCH 0

ADD UCELLHSDPCCH D2

ADD UCELLHSDPCCH 1

ADD UCELLHSDPCCH 1

SET UALGORSVPARA 0
SET UFRCCHLTYPEPARA 0

SET UCORRMALGOSWITCH 1

SET UCORRMALGOSWITCH
0
SET USTATETIMER 300

SET URRCTRLSWITCH 0
SET UNBMPARA 1

SET URRCTRLSWITCH 0
SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0
SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0
SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0
SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0
SET URRCTRLSWITCH 0

Huawei parameters
CS_RL_SETUP_SWITCH = 1
or PS_RL_SETUP_SWITCH =
1, recommended that this
SET URRCTRLSWITCH 0 parameter is set to 1, if
CS_RL_SETUP_SWITCH = 0
and PS_RL_SETUP_SWITCH
= 0, this parameter is set to
baseline.
Huawei parameters
CS_RL_SETUP_SWITCH = 1
or PS_RL_SETUP_SWITCH =
1, recommended that this
SET URRCTRLSWITCH 0 parameter is set to 1, if
CS_RL_SETUP_SWITCH = 0
and PS_RL_SETUP_SWITCH
= 0, this parameter is set to
baseline.

SET USTATETIMER 15000

SET USTATETIMER 35000


SET UCONNMODETIMER 3

SET UCONNMODETIMER D50


SET UCONNMODETIMER 0
SET UCONNMODETIMER 0
Huawei parameters
CS_RL_SETUP_SWITCH = 1
or PS_RL_SETUP_SWITCH =
1, recommended that this
SET UCONNMODETIMER D2000 parameter is set to D1400, if
CS_RL_SETUP_SWITCH = 0
and PS_RL_SETUP_SWITCH
= 0, this parameter is set to
baseline.

Huawei parameters
CS_RL_SETUP_SWITCH = 1
or PS_RL_SETUP_SWITCH =
1, recommended that this
SET UCONNMODETIMER 3 parameter is set to 3, if
CS_RL_SETUP_SWITCH = 0
and PS_RL_SETUP_SWITCH
= 0, this parameter is set to
baseline.

Huawei parameters
CS_RL_SETUP_SWITCH = 1
or PS_RL_SETUP_SWITCH =
1, recommended that this
SET UCONNMODETIMER D1 parameter is set to D20, if
CS_RL_SETUP_SWITCH = 0
and PS_RL_SETUP_SWITCH
= 0, this parameter is set to
baseline.
ADD UCELLSETUP 50 2015删除
ADD UCELLSETUP 5 2015删除

ADD UCELLSETUP 5s 2015删除


SET URRCTRLSWITCH 0

If RncFeature include in
DirectUpswitchUra,
SET URRCTRLSWITCH corresponding featureState
0 = ACTIVATED, then
RNC_TVM_BASED_P2D_SWI
TCH = 1; otherwise = 0;

LOOSE_CAC
ADD UCELLALGOSWITCH LOOSE_CAC
SET UCACALGOSWITCH 0

ADD UCELLALGOSWITCH 0

ADD UCELLALGOSWITCH 0

ADD UCELLALGOSWITCH 0
ADD UCELLALGOSWITCH ALGORITHM_SECOND

ADD UCELLALGOSWITCH ALGORITHM_FIRST


ADD UTYPRABHSPA D50

SET UFRC 1

SET UFRC 0

ADD 0
UCELLINTERFREQHOCOV

ADD
UCELLINTERFREQHOCOV 0
ADD UCELLINTERRATHOCOV 60 s
ADD UCELLINTERRATHOCOV 0
ADD UCELLINTERRATHOCOV D1000
ADD UCELLINTERRATHOCOV 0

SET UCORRMPARA 1
SET UQUEUEPREEMPT OFF

SET UQUEUEPREEMPT:
PreemptEnhSwitch=PREEMP
0
T_ENH_CSRRC_PREEMPT_PS
_SWITCH-1;
SET UQUEUEPREEMPT:
PreemptEnhSwitch=
PREEMPT_ENH_CSRAB_PRE 0
EMPT_PS_SWITCH-1;

SET UQUEUEPREEMPT 1

ADD UCELLCAC SF64(SF64) SF64(SF64)


ADD UCELLCAC SF128(SF128) SF128(SF128)
ADD UCELLALGOSWITCH LOOSE_CAC LOOSE_CAC
ADD UCELLCAC 5 5
ADD UCELLCAC 5 5
ADD UCELLCAC 0 0
SET UDPUCFGDATA ON
SET UQUEUEPREEMPT:
PsBERrcPreemptVulnerable= OFF
ON;

ADD UCELLALGOSWITCH 0

SET UQUEUEPREEMPT:
CsP2DPreemptSwitch=ON; OFF

IF [E///]qRxLevMin (MO
Class
Name:vsDataUtranCell)<-
ADD UCELLSELRESEL 0 115,
[HUAWEI]QrxlevminExtSup(
MML:ADD
UCELLSELRESEL)=TRUE
IF [E ///] qRxLevMin (MO
Class Name:
vsDataUtranCell) <- 115,
[HUAWEI] DeltaQrxlevmin
(MML: ADD UCELLSELRESEL)
ADD UCELLSELRESEL None = ([E ///] qRxLevMin (MO
Class Name:
vsDataUtranCell) +115) / 2
This parameter is not
configured ELSE

SET URRCTRLSWITCH 0

SET UFRC OFF


SET UCORRMALGOSWITCH 0

SET UCORRMPARA 0
SET ULDCALGOPARA 60

SET ULDCALGOPARA 60
SET UCORRMALGOSWITCH 0

SET UCORRMALGOSWITCH 0
SET UHSDPCCH D20

ADD UCELLHSDPCCH D20

SET URRCTRLSWITCH OFF

SET URRCTRLSWITCH OFF

SET UCORRMPARA OFF

SET URRCTRLSWITCH OFF

OFF

SET URRCTRLSWITCH

SET UCORRMALGOSWITCH 0
Characteristics of the
switching follows the
mapping rules, please refer
to the specific
characteristics of the
opening parameters
Manual:
If [E ///]
featureStateFDpchSrbOnHsd
pa == 1 (while
DCH(DCH,DCH) NodeBFunction ::
SET UFRCCHLTYPEPARA licenseStateFDpchSrbOnHsd
pa = ENABLED), then
[HUAWEI] SrbChlType =
HSPA, also set SET
UCORRMPARA:
PerfEnhanceSwitch =
PERFENH_SRB_OVER_HSUP
A_TTI10_SWITCH-1;
Otherwise [HUAWEI]
SrbChlType = DCH

SET UCORRMALGOSWITCH 0
SET UCORRMALGOSWITCH 0

ADD UOPERUSERGBR
D64
MOD UOPERUSERGBR

ADD UOPERUSERGBR
D64
MOD UOPERUSERGBR

ADD UCELLALGOSWITCH OFF OFF


SET UQUEUEPREEMPT 0

SET URRCTRLSWITCH 0

ADD URACH
MOD URACH 10

ADD URACH
MOD URACH 0
ADD
60
UCELLINTERFREQHOCOV

SET USTATETIMER 300

ADD UCELLALGOSWITCH 0

SET UALGORSVPARA 0

1
MOD UCELLCAC

SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0

SET URRCTRLSWITCH 0
SET URRCTRLSWITCH 0
SET UPSINACTTIMER 4
SET UCONNMODETIMER
INVALID

SET UPSINACTTIMER
SET UCORRMALGOSWITCH BasedOnUECap 2015删除

SET UCORRMALGOSWITCH:
SET UCORRMALGOSWITCH CmpSwitch2=CMP_F2D_RLC
0 _ONESIDE_REBUILD_SWITC
H-1;

SET UCORRMALGOSWITCH:
SET UCORRMALGOSWITCH CmpSwitch=CMP_D2F_RLC_
0
ONESIDE_REBUILD_SWITCH-
1;

SET UFRC:
RetryCapability=TTI_2MS-0;
SET UCORRMALGOSWITCH:
DraSwitch2=DRA_PCPICH_E
CN0_ON_RACH_UPDATE_S
WITCH-1;

SET UFRC: FakeEcNo=29;

SET UCORRMPARA:
PerfEnhanceSwitch=PERFEN
H_HSUPA_TTI_RECFG_PROC
_OPT_SWITCH-1;

SET UCORRMALGOSWITCH:
SET ReservedSwitch0=RESERVED
_SWITCH_0_BIT30-1;
UCORRMALGOSWITCH(R1
(R13/14)
3/14) SET
SET UNBMPARA:PerfEnhanceSwi
UNBMPARA(R15/R16) tch=PERFENH_HRNTI_OPT_S
WITCH-1; (R15/R16)

MOD UCELLHSDPA:
CellId=XX, HspaPower=0;
If the original network open
SRB OE, recommends the
implementation of the
following parameters.
//打开RAB DRD阶段限制 // Open RAB DRD stage
SRB承载信道D2H算法开关 restrictions SRB bearer
SET UCORRMALGOSWITCH: channel D2H algorithm
CmpSwitch2=CMP_DRD_SR switch
BOVERH_SWITCH-1; SET UCORRMALGOSWITCH:
CmpSwitch2 =
//打开RAB DRD流程结束后 CMP_DRD_SRBOVERH_SWIT
SRB承载信道由DCH快速重 CH-1;
试到E-DCH算法开关 // Open end of the process
SET UCORRMPARA: after RAB DRD SRB bearer
PerfEnhanceSwitch1=PERFE channel by the DCH quickly
NH_SRB_FAST_HRETRY_AFT retry algorithm switch to E-
ER_DRD_SWITCH-1; DCH
SET UCORRMPARA:
PerfEnhanceSwitch1 =
PERFENH_SRB_FAST_HRETR
Y_AFTER_DRD_SWITCH-1;

If the original network open


SRB OE, recommends the
implementation of the
following parameters.
SET UCORRMPARA
SET UCORRMPARA:
PerfEnhanceSwitch =
PERFENH_SRB_OVER_HSUP
A_TTI10_SWITCH-1;
SET UUESTATETRANS 8 E2FTHROUTHD=downswitch
Threshold

BEF2ETVMTHD [HW] take


more than D2F2PTVMTHD
[HW] gate-level limit
SET UUESTATETRANS D0
FASTDORMANCYF2DHTVMT
HD [HW] take more than
D2F2PTVMTHD [HW] gate-
level limit
SET UUESTATETRANS D1024
SET UUESTATETRANS D0
SET UUESTATETRANS D0
SET UUESTATETRANS D1000
SET UUESTATETRANS D5000
SET UUESTATETRANS 30
SET UUESTATETRANS 4 4
SET UUESTATETRANS D1024 30
If you open the PCH
(characteristic ID is
RabCombination021, which
featureState \ licenseState \
serviceState are open 1:00
showing URA_PCH, the best
road test to determine
whether to open), SET
UCORRMPARA:
PerfEnhanceSwitch3 =
PERFENH_INACTIVE_F2P_S
WITCH-1,
InactF2PstateTransTimer =
inactivityTimer;
Otherwise no maps.

SET UUESTATETRANSTIMER 10
SET URRCTRLSWITCH
0

SET URRCTRLSWITCH 0

SET
SET UCONNMODETIMER 5 UCONNMODETIMER:T309=8
;
SET URRCTRLSWITCH
0

SET UDPUCFGDATA
0

SET UCORRMALGOSWITCH 1
Direct use E /// original
ADD UEXT3GCELL -18 network value
IF [E///]qRxLevMin (MO
Class
Name:vsDataExternalGsmCe
ll)==100,
[HUAWEI]qRxLevMin=([E///]
qRxLevMin (MO Class
ADD UEXT3GCELL -58 Name:vsDataUtranCell)
+115)/2-58;
ELSE
[HUAWEI]qRxLevMin=([E///]
qRxLevMin (MO Class
Name:vsDataExternalGsmCe
ll) + 115)/2 - 58

Direct use E /// net value of


the original, the original
ADD UINTRAFREQNCELL 0 network parameters
obtained in
"vsDataUtranRelation" tab
直接使用E///原网值,原网
参数
ADD UINTRAFREQNCELL 0
在“vsDataUtranRelation”
页签中获取

HW = E / 5, the original
network parameters
ADD UEXT2GCELL 0
"vsDataUtranCell" tab page
accessible.

HW = E / 5, the original
network parameters
ADD UEXT3GCELL 0 "vsDataUtranCell" tab page
accessible.
ADD UINTERFREQNCELL
0 2015删除

ADD UINTRAFREQNCELL
0 2015删除
ADD UINTRAFREQNCELL
0 使用Huawei基线
ADD UINTRAFREQNCELL
0 使用Huawei基线

ADD U2GNCELL 0 2015删除


ESN Parameter ID ESN Meaning ESN Parameter Value Range

Admission limit based on


downlink channelization
code tree usage. Expressed
dlCodeAdm as percentage of the code 0..100
tree currently in use.
Used by Admission Control,
in Admission Request
Handler

Indicates if this cell shall be


cellReserved reserved for operator use. If
NOT_RESERVED;RESERVED
it is reserved, there will be
no service to the UEs.

FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)
FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)

FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)
FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)

FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)
FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)

FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)
FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)

FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)
FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)

FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)
FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)

FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)
FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)

FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)
FALSE(OR True),FALSE(OR
True),FALSE(OR
Specifies which access True),FALSE(OR
classes are barred for the True),FALSE(OR
feature Cell Level Access True),FALSE(OR
Class Barring. True),FALSE(OR
Each boolean in the True),FALSE(OR
accessClassNBarred sequence represents one True),FALSE(OR
access class. The access class True),FALSE(OR
is restricted by setting the True),FALSE(OR
boolean to TRUE ('barred'), True),FALSE(OR
otherwise the boolean is set True),FALSE(OR
to True),FALSE(OR
True),FALSE(OR
True),FALSE(OR True)

Maximum RoT (Rise over


eulMaxOwnUuLoad,eulMax Thermal) level allowed to 0...550
RotCoverage preserve coverage.

Admission limit on ASE in


the uplink.
Used by Admission Control,
in Admission Request
aseUlAdm 0..500
Handler.
Takes effect: Immediately
Unit: ASE
Admission limit for the
number of users assigned to
the HS-PDSCH/HS-SCCH in
hsdpaUsersAdm the cell. This limit is 0..1000
applicable both to HSDPA
RAB setup and to channel
switching.

The maximum number of


Serving EUL users allowed
per cell.
Precondition: If license key
'Number of EUL Users per
Cell' is enabled (see
NodeBFunction::licenseState
NumEulUsers), and Licensing
Emergency Unlock is not
activated, maxNumEulUsers
can not be set to a higher
maxNumEulUsers value than the license key 1..96
allows. If the license key is
disabled, maximum 4 EUL
users are allowed per cell. If
Licensing Emergency Unlock
is activated, maximum 96
EUL users are allowed per
cell.
Takes effect: Increase takes
effect immediately.
Decrease takes effect
gracefully (starving out
resources).
BCH power is the power to
be used for transmitting on
bchPower the BCH, relative to the -350..150
primaryCpichPower value

PICH power is the power to


be used for transmitting on
pichPower the physical channel -10..5
carrying the paging
indicators, relative to the
primaryCpichPower value

AICH power, to be used for


transmitting on AICH,
relative to the
aichPower primaryCpichPower value. -22..5
The value range is set to
cover both the RRC and
NBAP spec

Maximum power, to be used


for transmitting the first
FACH channel, relative the
maxFach1Power\maxFach2P
ower primaryCpichPower value. -350..150
The first FACH is used for
logical channels BCCH, CCCH
and DCCH, control signaling
Maximum power to be used
for transmitting the PCH,
pchPower relative to the -350..150
primaryCpichPower value

Primary SCH power, relative


primarySchPower to the primaryCpichPower -350..150
value

Secondary SCH power,


secondarySchPower relative to the -350..150
primaryCpichPower value

Maximum number of
preambleRetransMax preambles in one preamble 1..64
ramping cycle.

Power step when no


powerOffsetP0 acquisition indicator is 1..8
received
Constant value used by the
UE to calculate the initial
constantValueCprach
power on PRACH according -35..-10
to the Open loop power
control procedure

Power step between


powerOffsetPpm preamble and the message -5..10
part
Offset relative to the P-
CPICH that the UE must use
hsMeasurementPowerOffse when calculating the -60..130
t
assumed HS-PDSCH power
in the CQI estimation

The duration of the CQI


feedback cycle on HS-
DPCCH. If HSDPA Multi-
Carrier with MIMO is used in
a connection, then the CQI
cqiFeedbackCycle feedback cycle used for the
connection is max(4, 2, 4, 8, 10, 20, 40, 80, 160
cqiFeedbackCycle).

Dependencies: Must be set


equal to or greater than 2
ms *
initialCqiRepetitionFactor

Turns Active Queue


activeQueueMgmt Management function on ON,OFF
and off.
Indicates to the UE whether
IMSI attach/detach is
allowed. (Some IMSIs are
not allowed in some LAs.)
att This helps to facilitate the 1
avoidance of unnecessary
paging attempts. The value
is sent on the BCCH

Network operation mode


that indicates whether the
nmo Gs interface between the MODE_I (0)
MODE_II (1)
SGSN and MSC/VLR is
installed.

Feature state for licensed


feature 'Enhanced Layer 2',
featureStateEnhancedLayer DEACTIVATED = 0
2 indicating if the feature is ACTIVATED = 1
ACTIVATED or
DEACTIVATED.

Used to activate and


featureStateHsFach deactivate the feature HS- DEACTIVATED = 0
ACTIVATED = 1
FACH in the cell.

Indicates if 64QAM is DEACTIVATED = 0


featureState64Qam enabled or not for the RBS ACTIVATED = 1

Indicates if MIMO is enabled DEACTIVATED = 0


featureStateMIMO or not in the RBS ACTIVATED = 1

Support of 64QAM and


DEACTIVATED = 0
featureState64QamMimo MIMO Combination on cell ACTIVATED = 1
level
featureStateHsdpaMc Support of Multi Carrier on DEACTIVATED = 0
cell level ACTIVATED = 1

featureStateHsdpaMcMimo Support of Multi Carrier DEACTIVATED = 0


with MIMO on cell level ACTIVATED = 1

Capability information
indicating if F-DPCH is
fdpchSupport supported in the cell as DEACTIVATED = 0
reported by RBS in RSI and ACTIVATED = 1
Audit response.

Feature state for licensed


featureStateHsdpaDynamicC feature 'HSDPA Dynamic
Code Allocation', indicating DEACTIVATED, ACTIVATED
odeAllocation if the feature is ACTIVATED
or DEACTIVATED.

Parameter that determines


numHsScchCodes how many HS-SCCH’s that 1..4
shall be configured.
The maximum number of
maxNumHsPdschCodes HS-PDSCH codes allowed 5..15
per cell.

numHsPdschCodes Number of codes of SF=16 1..15


used for the HS-PDSCH.

maxPreambleCycle Maximum number of 1..32


preamble ramping cycles
Timer in UE between 0: No updating
periodic Cell Updates and 1: 5 min
periodic URA Updates. If 2: 10
timer expires, the UE sends 3: 30
t305 a new Cell Update message 4: 60
(when in state CELL_FACH) 5: 120
or URA Update message 6: 360
(when in state URA_PCH) 7: 720 min
dchRcLostT:
Timer that is started when
all radio links for a
connection are lost. At time-
out, the radio connection is
considered lost.
Special values:
The value 18000 deci
seconds = 1800 s = 30
minutes is used for testing
purposes to "disable" the
Radio Connection
Supervision functionality for
a UE on dedicated channels. dchRcLostT:
Takes effect: The value 0..100 18000..18000
dchRcLostT / hsDschRcLostT CANNOT be changed for an
ongoing connection; that is, hsDschRcLostT:
whenever the attribute is 0..600 18000..18000
reconfigured in the RNC, the
new value shall only apply to
new connections.

hsDschRcLostT:
Controls the RCS timer for
supervision of uplink synch
of RLS containing the serving
HS-DSCH radio link.
Special values:
18000 indicates that the RCS
function is switched off.
Used for test purposes

Preferred target rate in the


downlink for upswitching.
Applicable both when
setting up a non-HSDPA PS
Interactive RAB, and when
increasing the downlink rate 0..0 8..8 16..16 32..32 64..64
dlPrefRate of a PS interactive RAB from 128..128 144..144 256..256
a rate below the preferred 384..384 768..768
rate. 2048..2048
If the flexible initial rate
selection feature is not
active for PS Interactive, 64
kbps is used as the preferred
rate.
Preferred target rate in the
uplink for upswitching.
Applicable both when
setting up a non-EUL PS
Interactive RAB, and when
increasing the uplink rate of
a PS interactive RAB from a 0..0 8..8 16..16 32..32 64..64
ulPrefRate rate below the preferred 128..128 144..144 384..384
rate.
If the flexible initial rate
selection feature is not
active for PS Interactive, 64
kbps is used as the preferred
rate
Defines whether SRB DCH
3.4, SRB DCH 13.6 or SRB on
HS should be used as Stand-
alone SRB in the cell(s).
When set to SRB34, SRB is
setup on DCH(3.4)/DCH(3.4).
When set to SRB136, SRB is
setup on
DCH(13.6)/DCH(13.6). When
set to SRBHS, SRB is setup
SRB34 = 0
on HS if capabilities allow,
standAloneSrbSelector otherwise fallback to SRB136 = 1
SRBHS = 2
SRB136.
When the cells of the active
set are configured
differently, the cell with the
lowest value determines the
outcome, where the values
from the lowest to the
highest are SRB34, SRB136
and SRBHS. In DRNC, SRB is
always setup on DCH 13.6

Indicates whether 2 ms TTI OFF = 0


edchTti2Support(MO:Eul) is supported in the RBS or ON = 1
not.

serviceRestrictions.csVideoC Indicates which services are


FALSE(0);True(1)
alls restricted in this cell.
UL/DL RLC buffer threshold
for upswitching from
FACH/RACH to dedicated ulRlcBufUpswitch:8..8
channel. 16..16 32..32 64..64
When the RLC buffer load in 128..128 256..256 512..512
ulRlcBufUpswitch/dlRlcBufU
pswitch the uplink exceeds this 1024..1024 2048..2048
threshold, a measurement 3072..3072 4096..4096
report is sent from the UE. 6144..6144 8192..8192
An upswitch request is dlRlcBufUpswitch:0~2000
issued upon reception of the
measurement repor

Time after which an inactive


RB in a RAB combination
containing PS Interactive is
released.
When both the downlink
and uplink throughput for
an RB in the combination
have been 0 kbps (no data
has been transmitted) for
inactivityTimeMultiPsInterac this length of time, a release 1..10000
tive of that RB is requested from
the CN.
The timer is used for all RAB
combinations that contain
more than one PS
Interactive RAB.
Unit: 0.1 s
Change takes effect: New
connections
Defines whether 2ms TTI
shall be enabled or disabled
for RAB combinations
consisting of speech
together with EUL. Includes
all speech RABs, including
AMR Single-mode 12.2,
edchTti2SpeechEnabled AMR-NB Multi-mode (single- FALSE(0);True(1)
and multi-rate) and AMR-
WB.

Change takes effect: New


connection

down to multi-RAB SP0


("Speech 12.2 kbps + Packet
0/0 kbps"), if no PS data has
been transmitted.
If the SP0 feature is not
active, the packet part of the
connection is released
instead.
The default setting is based
on packet performance
criteria. However, the
actual setting may need to
deviate from the default
setting in order to limit the
number of simultaneous
multi-RAB connections in
the RBS, typically to deal
downswitchTimerSp with limitations in the 0..180
transport network.

Special values:
0 is used to turn off the use
of this timer, meaning that
the packet part of the
connection will not be
downswitched or released
due to PS inactivity.

Value mapping:
1 : 0.5 s
...
60 : 30 s
...
180 : 90 s
Minimum required
(acceptable) RX level in the
cell.
Used in UE functions for cell
selection/reselection in idle
mode and connected mode.
Value launched by System
information (SIB11) for each
intra-frequency
measurement object
corresponding to adjacent
qRxLevMin (MO Class
cells of serving cell.
Name:vsDataExternalGsmCe -115..-25,100..100
ll)
Special values:
100: Indicates that the
minimum Rx level has not
been specified by the
operator. The parameter is
then not
present in SIB11 for this
neighbor. The UE will use
the serving cell value
(UtranCell MO value)
instead
Control of cell
selection/reselection. Time-
to-trigger for cell
reselection.
treSelection Value launched by System 0..31
information (SIB3).
Unit: s
Used in UE functions for cell
selection/reselection in idle
mode and connected mode.
qQualMin Minimum required
(MO Class -24..0
Name:vsDataUtranCell) (acceptable) quality level in
the cell.

Unit: dB

Minimum required
(acceptable) quality level in
the cell (dB). Used to set cell
border between two cells.
Used in UE functions for cell
selection/reselection in idle
mode and connected mode.
qQualMin Special values:
(MO Class
Name:vsDataExternalUtranC 100: Indicates that the -24..0,100..100
minimum quality level has
ell) not been specified by the
operator. The parameter is
then not
present in SIB11 for this
neighbor. The UE will use
the serving cell value
(UtranCell MO value)
instead
Minimum required
(acceptable) quality level in
the cell (dB). Used to set cell
border between two cells.
Used in UE functions for cell
qQualMin selection/reselection in idle -24..0
mode and connected mode.

Special values:
100: Indicates that the
minimum quality level h
The decision on when
measurements on intra-
sIntraSearch frequencies shall be 0..27
performed
The decision on when
measurements on inter-
sInterSearch frequencies shall be 0..27
performed
The decision on when
measurements on GSM
frequencies shall be
performed is made using
this parameter in relation
with Squal.
sRatSearch If S_qual > this parameter, -32..20
UE need not perform
measurements on GSM
cells.
If S_qual <= this parameter,
UE shall perform meas

Time between detection of


event 2d and sending of the
measurement report, when
the measurement quantity 0..0 10..10 20..20 40..40
is CPICH EC/NO. 60..60 80..80 100..100
timeToTrigger2dEcno,timeT Special values: 120..120 160..160 200..200
oTrigger2dRscp When the value 5000 is set, 240..240 320..320 640..640
the Measurement Control 1280..1280 2560..2560
message will not be sent at 5000..5000
all.
Unit: ms
Change takes effect: Ongo
Time between detection of
event 2d and sending of the
measurement report, when
the measurement quantity 0..0 10..10 20..20 40..40
is CPICH EC/NO. 60..60 80..80 100..100
timeToTrigger2fEcno,timeTo Special values: 120..120 160..160 200..200
Trigger2fRscp When the value 5000 is set, 240..240 320..320 640..640
the Measurement Control 1280..1280 2560..2560
message will not be sent at 5000..5000
all.
Unit: ms
Change takes effect: Ongo

usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dEcno:
usedFreqThresh2dEcno+ser is Ec/No. -24..0
viceOffset2dEcno
serviceOffset2dEcno: serviceOffset2dEcno:
Service-specific offset for -20..20
event 2d when the
measurement quantity is
CPICH Ec/No
Time between detection of
event 2d and sending of the
measurement report, when
the measurement quantity 0..0 10..10 20..20 40..40
is CPICH EC/NO. 60..60 80..80 100..100
timeToTrigger2dEcno,timeT Special values: 120..120 160..160 200..200
oTrigger2dRscp When the value 5000 is set, 240..240 320..320 640..640
the Measurement Control 1280..1280 2560..2560
message will not be sent at 5000..5000
all.
Unit: ms
Change takes effect: Ongo
Time between detection of
event 2d and sending of the
measurement report, when
the measurement quantity 0..0 10..10 20..20 40..40
is CPICH EC/NO. 60..60 80..80 100..100
timeToTrigger2fEcno,timeTo Special values: 120..120 160..160 200..200
Trigger2fRscp When the value 5000 is set, 240..240 320..320 640..640
the Measurement Control 1280..1280 2560..2560
message will not be sent at 5000..5000
all.
Unit: ms
Change takes effect: Ongo
Time between detection of
timeToTrigger3a event 3a and sending of the 0..15
measurement report
Time between detection of
timeToTrigger3a event 3a and sending of the 0..15
measurement report
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dEcno:
is Ec/No. -24..0
usedFreqThresh2dEcno+ser
viceOffset2dEcno
serviceOffset2dEcno: serviceOffset2dEcno:
Service-specific offset for -20..20
event 2d when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dEcno:
is Ec/No. -24..0
usedFreqThresh2dEcno+ser
viceOffset2dEcno
serviceOffset2dEcno: serviceOffset2dEcno:
Service-specific offset for -20..20
event 2d when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dRscp:
is RSCP -115..-25
usedFreqThresh2dRscp+serv
iceOffset2dRscp
serviceOffset2dRscp: serviceOffset2dRscp:
Service-specific offset for -50..50
event 2d when the
measurement quantity is
RSCP
Threshold for event 3a for
GSM. Range is valid for GSM
carrier RSSI.

gsmThresh3a Unit: dBm -115..0


Change takes effect:
Ongoing connections (next
time that inter-RAT
measurements are started)
Threshold for event 3a for
GSM. Range is valid for GSM
carrier RSSI.

gsmThresh3a Unit: dBm -115..0


Change takes effect:
Ongoing connections (next
time that inter-RAT
measurements are started)
Threshold for event 3a for
GSM. Range is valid for GSM
carrier RSSI.

gsmThresh3a Unit: dBm -115..0


Change takes effect:
Ongoing connections (next
time that inter-RAT
measurements are started)
Used by UE functions for
intra-frequency
measurement reporting (in
reportingRange1b
CELL_DCH). Threshold used 0..29
for drop window in
evaluation criteria for event
1b
Used by UE functions for
intra-frequency
measurement reporting (in
reportingRange1b CELL_DCH). Threshold used
for drop window in 0..29
evaluation criteria for event
1b.
Used by UE functions for
intra-frequency
measurement reporting (in
reportingRange1b
CELL_DCH). Threshold used 0..29
for drop window in
evaluation criteria for event
1b
Hysteresis used in addition-
window in evaluation
criteria for event 1a to avoid
ping pong effects. Used by
UE functions for intra-
frequency measurement
reporting in CELL_DCH.
hysteresis1a
0..15
Value mapping:
0 : 0.0dB (no hysteresis)
1 : 0.5dB
...
15 : 7.5dB

Unit: 0.5 dB

Hysteresis used in the drop


window in evaluation
criteria for event type 1b.
hysteresis1b Used by UE functions for 0..15
intra-frequency
measurement reporting in
CELL_DCH
Hysteresis used in drop
window in evaluation
criteria for event type 1d.
hysteresis1d Used by UE functions for 0..15
intra-frequency
measurement reporting (in
CELL_DCH)

Time between detection of


event 2d and sending of the
measurement report, when
the measurement quantity 0..0 10..10 20..20 40..40
is CPICH EC/NO. 60..60 80..80 100..100
timeToTrigger2dEcno,timeT Special values: 120..120 160..160 200..200
oTrigger2dRscp When the value 5000 is set, 240..240 320..320 640..640
the Measurement Control 1280..1280 2560..2560
message will not be sent at 5000..5000
all.
Unit: ms
Change takes effect: Ongo

Time between detection of


event 2d and sending of the
measurement report, when
the measurement quantity 0..0 10..10 20..20 40..40
is CPICH EC/NO. 60..60 80..80 100..100
timeToTrigger2fEcno,timeTo Special values: 120..120 160..160 200..200
Trigger2fRscp When the value 5000 is set, 240..240 320..320 640..640
the Measurement Control 1280..1280 2560..2560
message will not be sent at 5000..5000
all.
Unit: ms
Change takes effect: Ongo
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dEcno:
is Ec/No. -24..0
usedFreqThresh2dEcno+ser
viceOffset2dEcno
serviceOffset2dEcno: serviceOffset2dEcno:
Service-specific offset for -20..20
event 2d when the
measurement quantity is
CPICH Ec/No

usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity
is Ec/No.
usedFreqThresh2dEcno:
serviceOffset2dEcno: -24..0
usedFreqThresh2dEcno+ser Service-specific offset for
viceOffset2dEcno+usedFreq event 2d when the serviceOffset2dEcno:
RelThresh2fEcno measurement quantity is -20..20
CPICH Ec/No
usedFreqRelThresh2fEcno:
usedFreqRelThresh2fEcno: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dEcno:
is Ec/No. -24..0
usedFreqThresh2dEcno+ser
viceOffset2dEcno
serviceOffset2dEcno: serviceOffset2dEcno:
Service-specific offset for -20..20
event 2d when the
measurement quantity is
CPICH Ec/No

usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dEcno:
is Ec/No. -24..0
usedFreqThresh2dEcno+ser
viceOffset2dEcno
serviceOffset2dEcno: serviceOffset2dEcno:
Service-specific offset for -20..20
event 2d when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity
is Ec/No.
usedFreqThresh2dEcno:
serviceOffset2dEcno: -24..0
usedFreqThresh2dEcno+ser Service-specific offset for
viceOffset2dEcno+usedFreq event 2d when the serviceOffset2dEcno:
RelThresh2fEcno measurement quantity is -20..20
CPICH Ec/No.
usedFreqRelThresh2fEcno:
usedFreqRelThresh2fEcno: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
CPICH Ec/No

usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity
is Ec/No.
usedFreqThresh2dEcno:
serviceOffset2dEcno: -24..0
usedFreqThresh2dEcno+ser Service-specific offset for
viceOffset2dEcno+usedFreq event 2d when the serviceOffset2dEcno:
RelThresh2fEcno measurement quantity is -20..20
CPICH Ec/No.
usedFreqRelThresh2fEcno:
usedFreqRelThresh2fEcno: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dRscp:
usedFreqThresh2dRscp+serv is RSCP. -115..-25
iceOffset2dRscp
serviceOffset2dRscp: serviceOffset2dRscp:
Service-specific offset for -50..50
event 2d when the
measurement quantity is
RSCP

usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity
is RSCP.
usedFreqThresh2dRscp:
serviceOffset2dRscp: -115..-25
usedFreqThresh2dRscp+serv Service-specific offset for
iceOffset2dRscp+usedFreqR event 2d when the serviceOffset2dRscp:
elThresh2fRscp measurement quantity is -50..50
RSCP.
usedFreqRelThresh2fRscp:
usedFreqRelThresh2fRscp: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
RSCP
usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dRscp:
usedFreqThresh2dRscp+serv is RSCP. -115..-25
iceOffset2dRscp
serviceOffset2dRscp: serviceOffset2dRscp:
Service-specific offset for -50..50
event 2d when the
measurement quantity is
RSCP

usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dRscp:
usedFreqThresh2dRscp+serv is RSCP. -115..-25
iceOffset2dRscp
serviceOffset2dRscp: serviceOffset2dRscp:
Service-specific offset for -50..50
event 2d when the
measurement quantity is
RSCP
usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity
is RSCP.
usedFreqThresh2dRscp:
serviceOffset2dRscp: -115..-25
usedFreqThresh2dRscp+serv Service-specific offset for
iceOffset2dRscp+usedFreqR event 2d when the serviceOffset2dRscp:
elThresh2fRscp measurement quantity is -50..50
RSCP.
usedFreqRelThresh2fRscp:
usedFreqRelThresh2fRscp: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
RSCP

usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity
is RSCP.
usedFreqThresh2dRscp:
serviceOffset2dRscp: -115..-25
usedFreqThresh2dRscp+serv Service-specific offset for
iceOffset2dRscp+usedFreqR event 2d when the serviceOffset2dRscp:
elThresh2fRscp measurement quantity is -50..50
RSCP.
usedFreqRelThresh2fRscp:
usedFreqRelThresh2fRscp: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
RSCP
Time between detection of
event 2d and sending of the
measurement report, when
0..0 10..10 20..20 40..40
the measurement quantity 60..60 80..80 100..100
is CPICH EC/NO.
timeToTrigger2dEcno,timeT 120..120 160..160 200..200
oTrigger2dRscp Special values: 240..240 320..320 640..640
When the value 5000 is set,
the Measurement Control 1280..1280 2560..2560
5000..5000
message will not be sent at
all.
Change takes effect: Ongo
Time between detection of
event 2d and sending of the
measurement report, when
the measurement quantity 0..0 10..10 20..20 40..40
is CPICH EC/NO. 60..60 80..80 100..100
timeToTrigger2fEcno,timeTo Special values: 120..120 160..160 200..200
Trigger2fRscp When the value 5000 is set, 240..240 320..320 640..640
the Measurement Control 1280..1280 2560..2560
message will not be sent at 5000..5000
all.
Unit: ms
Change takes effect: Ongo
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dEcno:
is Ec/No. -24..0
usedFreqThresh2dEcno+ser
viceOffset2dEcno
serviceOffset2dEcno: serviceOffset2dEcno:
Service-specific offset for -20..20
event 2d when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity
is Ec/No.
usedFreqThresh2dEcno:
serviceOffset2dEcno: -24..0
usedFreqThresh2dEcno+ser Service-specific offset for
viceOffset2dEcno+usedFreq event 2d when the serviceOffset2dEcno:
RelThresh2fEcno measurement quantity is -20..20
CPICH Ec/No.
usedFreqRelThresh2fEcno:
usedFreqRelThresh2fEcno: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dEcno:
is Ec/No. -24..0
usedFreqThresh2dEcno+ser
viceOffset2dEcno
serviceOffset2dEcno: serviceOffset2dEcno:
Service-specific offset for -20..20
event 2d when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dEcno:
is Ec/No. -24..0
usedFreqThresh2dEcno+ser
viceOffset2dEcno
serviceOffset2dEcno: serviceOffset2dEcno:
Service-specific offset for -20..20
event 2d when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity
is Ec/No. usedFreqThresh2dEcno:
-24..0
usedFreqThresh2dEcno+ser serviceOffset2dEcno:
viceOffset2dEcno+usedFreq Service-specific offset for serviceOffset2dEcno:
RelThresh2fEcno event 2d when the -20..20
measurement quantity is
CPICH Ec/No usedFreqRelThresh2fEcno:
0..20
usedFreqRelThresh2fEcno:
Relative threshold for event
2f versus event 2d for the
used frequency when
usedFreqThresh2dEcno:
Threshold for event 2d for
the used frequency when
the measurement quantity
is Ec/No.
usedFreqThresh2dEcno:
serviceOffset2dEcno: -24..0
usedFreqThresh2dEcno+ser Service-specific offset for
viceOffset2dEcno+usedFreq event 2d when the serviceOffset2dEcno:
RelThresh2fEcno measurement quantity is -20..20
CPICH Ec/No.
usedFreqRelThresh2fEcno:
usedFreqRelThresh2fEcno: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
CPICH Ec/No
usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dRscp:
is RSCP. -115..-25
usedFreqThresh2dRscp+serv
iceOffset2dRscp
serviceOffset2dRscp: serviceOffset2dRscp:
Service-specific offset for -50..50
event 2d when the
measurement quantity is
RSCP

usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity
is RSCP.
usedFreqThresh2dRscp:
serviceOffset2dRscp: -115..-25
usedFreqThresh2dRscp+serv Service-specific offset for
iceOffset2dRscp+usedFreqR event 2d when the serviceOffset2dRscp:
elThresh2fRscp measurement quantity is -50..50
RSCP.
usedFreqRelThresh2fRscp:
usedFreqRelThresh2fRscp: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
RSCP
usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dRscp:
is RSCP. -115..-25
usedFreqThresh2dRscp+serv
iceOffset2dRscp
serviceOffset2dRscp: serviceOffset2dRscp:
Service-specific offset for -50..50
event 2d when the
measurement quantity is
RSCP
usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity usedFreqThresh2dRscp:
is RSCP. -115..-25
usedFreqThresh2dRscp+serv
iceOffset2dRscp
serviceOffset2dRscp: serviceOffset2dRscp:
Service-specific offset for -50..50
event 2d when the
measurement quantity is
RSCP

usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity
is RSCP.
usedFreqThresh2dRscp:
serviceOffset2dRscp: -115..-25
usedFreqThresh2dRscp+serv Service-specific offset for
iceOffset2dRscp+usedFreqR event 2d when the serviceOffset2dRscp:
elThresh2fRscp measurement quantity is -50..50
RSCP.
usedFreqRelThresh2fRscp:
usedFreqRelThresh2fRscp: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
RSCP
usedFreqThresh2dRscp:
Threshold for event 2d for
the used frequency when
the measurement quantity
is RSCP.
usedFreqThresh2dRscp:
serviceOffset2dRscp: -115..-25
usedFreqThresh2dRscp+serv Service-specific offset for
iceOffset2dRscp+usedFreqR event 2d when the serviceOffset2dRscp:
elThresh2fRscp measurement quantity is -50..50
RSCP.
usedFreqRelThresh2fRscp:
usedFreqRelThresh2fRscp: 0..20
Relative threshold for event
2f versus event 2d for the
used frequency when the
measurement quantity is
RSCP
Threshold for event 3a for
GSM. Range is valid for GSM
carrier RSSI.

gsmThresh3a Unit: dBm -115..0


Change takes effect:
Ongoing connections (next
time that inter-RAT
measurements are started)
Threshold for event 3a for
GSM. Range is valid for GSM
carrier RSSI.

gsmThresh3a Unit: dBm -115..0


Change takes effect:
Ongoing connections (next
time that inter-RAT
measurements are started)
Threshold for event 3a for
GSM. Range is valid for GSM
carrier RSSI.

gsmThresh3a Unit: dBm -115..0


Change takes effect:
Ongoing connections (next
time that inter-RAT
measurements are started)
Used by UE functions for
intra-frequency
measurement reporting (in
reportingRange1a CELL_DCH). Threshold used 0..29
for addition-window in
evaluation criteria for event
type 1a
Used by UE functions for
intra-frequency
measurement reporting (in
reportingRange1a CELL_DCH). Threshold used
for addition-window in 0..29
evaluation criteria for event
type 1a.
Used by UE functions for
intra-frequency
measurement reporting (in
reportingRange1a
CELL_DCH). Threshold used 0..29
for addition-window in
evaluation criteria for event
type 1a
Used by UE functions for
intra-frequency
measurement reporting (in
reportingRange1b
CELL_DCH). Threshold used 0..29
for drop window in
evaluation criteria for event
1b
Used by UE functions for
intra-frequency
measurement reporting (in
CELL_DCH). Threshold used
reportingRange1b
for drop window in 0..29
evaluation criteria for event
1b.
Used by UE functions for
intra-frequency
measurement reporting (in
reportingRange1b
CELL_DCH). Threshold used 0..29
for drop window in
evaluation criteria for event
1b
Hysteresis used in addition-
window in evaluation
criteria for event 1a to avoid
ping pong effects. Used by
UE functions for intra-
frequency measurement
reporting in CELL_DCH.
hysteresis1a
0..15
Value mapping:
0 : 0.0dB (no hysteresis)
1 : 0.5dB
...
15 : 7.5dB

Unit: 0.5 dB

Hysteresis used in the drop


window in evaluation
criteria for event type 1b.
hysteresis1b Used by UE functions for 0..15
intra-frequency
measurement reporting in
CELL_DCH
Hysteresis used in drop
window in evaluation
hysteresis1d criteria for event type 1d.
Used by UE functions for 0..15
intra-frequency
measurement reporting (in
CELL_DCH)

Time between detection of


event 1a and sending of the
measurement report.
timeToTrigger1a Used by UE functions for 0..15
intra-frequency
measurement reporting in
CELL_DCH
Time between detection of
event 1b and sending of the
measurement report.
timeToTrigger1b Used by UE functions for 0..15
intra-frequency
measurement reporting in
CELL_DCH
Time between detection of
timeToTrigger1d event 1d and sending of the 0..15
measurement report
Interval of event-triggered
periodical reporting in case
of 'cell addition failure' or
'cell replacement failure'.
Indicates the interval in
reportingInterval1a
seconds of periodical 0..7
reporting triggered by event
1a.
Used by UE functions for
intra-frequency
measurement repo
Interval of event-triggered
periodical reporting in case
of 'cell addition failure' or
'cell replacement failure'.
Indicates the interval in
reportingInterval1c seconds of periodical 0..7
reporting triggered by event
1c.
Used by UE functions for
intra-frequency
measurement repo

Used by UE functions for


intra-frequency
measurement reporting (in
hysteresis1c CELL_DCH). Hysteresis used 0..15
in replacement threshold in
evaluation criteria for event
1c to avoid ping pong effects
Time between detection of
event 1c and sending of the
measurement report.
timeToTrigger1c Used by UE functions for 0..15
intra-frequency
measurement reporting in
CELL_DCH
Interval of event-triggered
periodical reporting in case
of 'cell addition failure' or
'cell replacement failure'.
Indicates the interval in
reportingInterval1a seconds of periodical 0..7
reporting triggered by event
1a.
Used by UE functions for
intra-frequency
measurement repo
Interval of event-triggered
periodical reporting in case
of 'cell addition failure' or
'cell replacement failure'.
Indicates the interval in
reportingInterval1c seconds of periodical 0..7
reporting triggered by event
1c.
Used by UE functions for
intra-frequency
measurement repo

Used by UE functions for


intra-frequency
measurement reporting (in
CELL_DCH). Hysteresis used
hysteresis1c in replacement threshold in 0..15
evaluation criteria for event
1c to avoid ping pong
effects.
Time between detection of
event 1c and sending of the
measurement report.
timeToTrigger1c Used by UE functions for 0..15
intra-frequency
measurement reporting in
CELL_DCH
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
Ec/No.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bEc and Rscp quality level of the
no+ serviceOffset2dEcno target cell before an Inter- -24..0
Frequency Handover is
attempt, can also be
disabled for the Ec/No
measurement quantity, by
setting the
NonUsedFreqThresh4_2bEc
no to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
Ec/No.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bEc and Rscp quality level of the -24..0
no+ serviceOffset2dEcno target cell before an Inter-
Frequency Handover is
attempt, can also be
disabled for the Ec/No
measurement quantity, by
setting the
NonUsedFreqThresh4_2bEc
no to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
Ec/No.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bEc and Rscp quality level of the
-24..0
no+ serviceOffset2dEcno target cell before an Inter-
Frequency Handover is
attempt, can also be
disabled for the Ec/No
measurement quantity, by
setting the
NonUsedFreqThresh4_2bEc
no to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
RSCP.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bRs and RSCP quality level of the
cp+ serviceOffset2dRscp target cell before an Inter- -115..25
Frequency Handover is
attempt, can also be
disabled for the RSCP
measurement quantity, by
setting the
NonUsedFreqThresh4_2bRs
cp to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
RSCP.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bRs and RSCP quality level of the
cp+ serviceOffset2dRscp target cell before an Inter- -115..25
Frequency Handover is
attempt, can also be
disabled for the RSCP
measurement quantity, by
setting the
NonUsedFreqThresh4_2bRs
cp to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
RSCP.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bRs and RSCP quality level of the
-115..25
cp+ serviceOffset2dRscp target cell before an Inter-
Frequency Handover is
attempt, can also be
disabled for the RSCP
measurement quantity, by
setting the
NonUsedFreqThresh4_2bRs
cp to its minimum value
Coefficient for layer 3
filtering before inter-
frequency reporting
evaluation, for 0..9 11..11 13..13 15..15
filterCoeff4_2b measurement 4 event 2b.
Change takes effect: 17..17 19..19
Ongoing connections (next
time that inter-frequency
measurements are started)

Coefficient for layer 3


filtering before inter-
frequency measurement
reporting evaluation.
0..9 11..11 13..13 15..15
filterCoefficient2 Change takes effect: 17..17 19..19
Ongoing connections (next
time that 2d/2f
measurements are started
or modified)
Coefficient for layer 3
filtering of GSM quality
before inter-RAT reporting
evaluation. 0..9 11..11 13..13 15..15
gsmFilterCoefficient3
Change takes effect: 17..17 19..19
Ongoing connections (next
time that inter-RAT
measurements are started)

Indicates if the RNC


fddGsmHOSupp supports Inter RAT 0;1
Handover.

Indicates if the RNC


fddGsmHOSupp supports Inter RAT 0;1
Handover.
Signal strength offset
between source and target
cells.

Dependencies:
Used when the IE
qOffset1sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/12 is set to "CPICH
RSCP". This is configured
through
UtranCell::qualMeasQuantit
y
Maximum number of cells in
active set.
The reporting deactivation
threshold, used to control
intra-frequency
maxActiveSet measurements (event 1a), is 2..4
set to maxActiveSet - 1.
The replacement activation
threshold, used to control
intra-frequency
measurements (event 1c)
Cell reselection hysteresis
used in UE functions in idle
qHyst1 and connected mode. Value 0..40
launched by System
information (SIB3)
The hysteresis value of the
serving cell.
qHyst2 Used to perform cell ranking 0..40
for the serving cell

Core Network DRX cycle


length coefficient (k) for UEs
in idle mode, packet
switched.
The cycle length is
t3212 calculated as the k'th 0..255
potential of 2, where k =
6..9. For example, 6
corresponds to cycle length
640 ms, 7 corresponds to
cycle length 1280 ms, etc
The DRX cycle length
coefficient (k) for UEs in
URA_PCH.
The DRX cycle length is the
frequency with which the UE
listens on the paging
utranDrxCycleLength channel. The parameter is 3..9
applicable for both UTRAN
and CN initiated paging in
URA_PCH.

Value mapping:
The cycle length

Signal strength offset


between source and target
cells.

Dependencies:
Used when the IE
qOffset1sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/12 is set to "CPICH
RSCP". This is configured
through
UtranCell::qualMeasQuantit
y

Signal strength offset


between source and target
cells. used when the IE
qOffset2sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/22 is set to "CPICH
Ec/No".
Signal strength offset
between source and target
cells.

Dependencies:
Used when the IE
qOffset1sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/12 is set to "CPICH
RSCP". This is configured
through
UtranCell::qualMeasQuantit
y

Signal strength offset


between source and target
cells. used when the IE
qOffset2sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/22 is set to "CPICH
Ec/No".

Timing delay used for


defining start of SCH, CPICH
tCell 0..9
and the downlink scrambling
codes
Cell identity.
Unique in the RNC.
cId is the identifier of a cell
in one RNC, and is used
together with the
cId RncFunction attribute rncId 0..65535
as cell id at system
information broadcast.

Dependencies:
Changing this attribute may
affect ongoing traffic.

Downlink UTRA Absolute


Radio Frequency Channel
Number. Specifies the
channel number for the
central downlink frequency.
The mapping from channel
uarfcnDl number to physical 0..16383
frequency is described in
3GPP specification TS
25.104.
Dependencies:
An intra-frequency
Hysteresis for event 2d.

Value mapping:
0: 0.0 dB
1: 0.5 dB
...
29: 14.5 dB
hysteresis2d 0..29
Unit: 0.5 db
Change takes effect:
Ongoing connections (next
time that 2d/2f
measurements are started
or modified)
Hysteresis for event 2f.

Value mapping:
0: 0.0 dB
1: 0.5 dB
...
hysteresis2f 29: 14.5 dB 0..29
Change takes effect:
Ongoing connections (next
time that 2d/2f
measurements are started
or modified)
Hysteresis for event 2d.

Change takes effect:


hysteresis2d Ongoing connections (next 0..29
time that 2d/2f
measurements are started
or modified)
Hysteresis for event 2f.

Change takes effect:


hysteresis2f Ongoing connections (next 0..29
time that 2d/2f
measurements are started
or modified)
Time between detection of
timeToTrigger1d event 1d and sending of the 0..15
measurement report
Hysteresis for event 2d.

Change takes effect:


hysteresis2d Ongoing connections (next 0..29
time that 2d/2f
measurements are started
or modified)
Hysteresis for event 2f.

Change takes effect:


hysteresis2f Ongoing connections (next 0..29
time that 2d/2f
measurements are started
or modified)
Hysteresis for event 2d.

Change takes effect:


hysteresis2d Ongoing connections (next 0..29
time that 2d/2f
measurements are started
or modified)
Hysteresis for event 2f.

Change takes effect:


hysteresis2f Ongoing connections (next 0..29
time that 2d/2f
measurements are started
or modified)
Coefficient for layer 3
filtering before intra-
frequency reporting
0..9 11..11 13..13 15..15
filterCoefficient1 evaluation. 17..17 19..19
Change takes effect:
Ongoing connections (next
switch to CELL_DCH)
Used by UE functions for
intra-frequency
measurements (in
CELL_DCH). Quantity to
measure for the chosen
mode. The value of this
measQuantity1 attribute will set the 0
message data CPICH_Ec/No
or CPICH_RSCP accordingly.

Dependencies:
If CN Hard Handover is
supported and

This parameter specifies the


number of reporting times
of event 1A for periodical
amountOfReporting1a reporting. When the actual 1, 2, 4, 8, 16, 32, 64,
reporting times exceeds the INFINITY
set value, the periodical
reporting ends

This parameter specifies the


number of reporting times
of event 1C for periodical
1, 2, 4, 8, 16, 32, 64,
amountOfReporting1c reporting. When the actual INFINITY
reporting times exceeds the
set value, the periodical
reporting ends.
Coefficient for layer 3
filtering before intra-
frequency reporting
0..9 11..11 13..13 15..15
filterCoefficient1 evaluation. 17..17 19..19
Change takes effect:
Ongoing connections (next
switch to CELL_DCH)
Used by UE functions for
intra-frequency
measurements (in
CELL_DCH). Quantity to
measure for the chosen
mode. The value of this
measQuantity1 attribute will set the 0
message data CPICH_Ec/No
or CPICH_RSCP accordingly.

Dependencies:
If CN Hard Handover is
supported and

This parameter specifies the


number of reporting times
of event 1A for periodical
amountOfReporting1a reporting. When the actual 1, 2, 4, 8, 16, 32, 64,
reporting times exceeds the INFINITY
set value, the periodical
reporting ends

This parameter specifies the


number of reporting times
of event 1C for periodical
1, 2, 4, 8, 16, 32, 64,
amountOfReporting1c reporting. When the actual INFINITY
reporting times exceeds the
set value, the periodical
reporting ends.
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
Ec/No.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bEc and Rscp quality level of the
no+ serviceOffset2dEcno target cell before an Inter- -24..0
Frequency Handover is
attempt, can also be
disabled for the Ec/No
measurement quantity, by
setting the
NonUsedFreqThresh4_2bEc
no to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
Ec/No.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bEc and Rscp quality level of the
-24..0
no+ serviceOffset2dEcno target cell before an Inter-
Frequency Handover is
attempt, can also be
disabled for the Ec/No
measurement quantity, by
setting the
NonUsedFreqThresh4_2bEc
no to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
Ec/No.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bEc and Rscp quality level of the -24..0
no+ serviceOffset2dEcno target cell before an Inter-
Frequency Handover is
attempt, can also be
disabled for the Ec/No
measurement quantity, by
setting the
NonUsedFreqThresh4_2bEc
no to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
RSCP.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bRs and RSCP quality level of the
cp+ serviceOffset2dRscp target cell before an Inter- -115..25
Frequency Handover is
attempt, can also be
disabled for the RSCP
measurement quantity, by
setting the
NonUsedFreqThresh4_2bRs
cp to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
RSCP.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bRs and RSCP quality level of the
-115..25
cp+ serviceOffset2dRscp target cell before an Inter-
Frequency Handover is
attempt, can also be
disabled for the RSCP
measurement quantity, by
setting the
NonUsedFreqThresh4_2bRs
cp to its minimum value
Defines the threshold for
event 2b for the non-used
frequency when
measurement quantity is
RSCP.
The initially check
performed for both Ec/No
NonUsedFreqThresh4_2bRs and RSCP quality level of the
cp+ serviceOffset2dRscp target cell before an Inter- -115..25
Frequency Handover is
attempt, can also be
disabled for the RSCP
measurement quantity, by
setting the
NonUsedFreqThresh4_2bRs
cp to its minimum value

Hysteresis used for event 2b


(the estimated quality of the
currently used frequency is 0..75
hyst4_2b below a certain threshold
and the estimated quality of step:0.1dB
a non-used frequency is
above a certain threshold).
Weighting factor for event 0.0...2.0
usedFreqW2d 2d for the used frequency step:0.1

Time between detection of 0; 10; 20; 40; 60; 80; 100;


timeTrigg4_2b event 2b and sending of the 120; 160; 200; 240; 320;
measurement report, for
measurement 4. 640; 1280; 2560; 5000
Relative threshold for event
2b versus event 2d for the
used frequency (the
estimated quality of the
usedFreqThresh2dEcno+ser currently used frequency is
below a certain threshold +
viceOffset2dEcno+usedFreq usedFreqThresh2dEcno and -10..10
RelThresh4_2bEcno the estimated quality of a
non-used frequency is above
a certain threshold), when
the 2d measurement
quantity is Ec/No

Relative threshold for event


2b versus event 2d for the
used frequency (the
estimated quality of the
currently used frequency is
usedFreqThresh2dRscp+serv below a certain threshold +
iceOffset2dRscp+usedFreqR -20..20
elThresh4_2bRscp usedFreqThresh2dRscp and
the estimated quality of a
non-used frequency is above
a certain threshold), when
2d measurement quantity is
RSCP
Relative threshold for event
2b versus event 2d for the
used frequency (the
estimated quality of the
currently used frequency is
usedFreqThresh2dEcno+ser
viceOffset2dEcno+usedFreq below a certain threshold + -10..10
usedFreqThresh2dEcno and
RelThresh4_2bEcno the estimated quality of a
non-used frequency is above
a certain threshold), when
the 2d measurement
quantity is Ec/No

Relative threshold for event


2b versus event 2d for the
used frequency (the
estimated quality of the
usedFreqThresh2dEcno+ser currently used frequency is
below a certain threshold +
viceOffset2dEcno+usedFreq -10..10
RelThresh4_2bEcno usedFreqThresh2dEcno and
the estimated quality of a
non-used frequency is above
a certain threshold), when
the 2d measurement
quantity is Ec/No
Relative threshold for event
2b versus event 2d for the
used frequency (the
estimated quality of the
currently used frequency is
usedFreqThresh2dRscp+serv
iceOffset2dRscp+usedFreqR below a certain threshold + -20..20
usedFreqThresh2dRscp and
elThresh4_2bRscp the estimated quality of a
non-used frequency is above
a certain threshold), when
2d measurement quantity is
RSCP

Relative threshold for event


2b versus event 2d for the
used frequency (the
estimated quality of the
usedFreqThresh2dRscp+serv currently used frequency is
below a certain threshold +
iceOffset2dRscp+usedFreqR -20..20
elThresh4_2bRscp usedFreqThresh2dRscp and
the estimated quality of a
non-used frequency is above
a certain threshold), when
2d measurement quantity is
RSCP
0..15
hysteresis3a Hysteresis used for event 3a step:0.5dB
Weighting factor for event 0.0...2.0
usedFreqW2d 2d for the used frequency step:0.1
Maximum number of
repeated proposals of non-
used frequency cell(s) for
ifHoAmountPropRepeat handover based on the 0..25
same measurement report,
not including the first
attempt

Minimum time interval


between proposals of the
same non-used frequency 0..25
ifHoPropRepeatInterval
cell for handover based on step:0.2s
the same measurement
report.
Maximum number of
repeated proposals (that is,
not including the first
gsmAmountPropRepeat proposal) of GSM cell(s) for 0..25
handover based on the
same measurement report

Minimum time interval


between proposals of the 0..25
gsmPropRepeatInterval same GSM cell for handover
based on the same step:0.2s
measurement report
This offset is added to the
measured quantity before
the UE evaluates if an event
has occurred.
individualOffset Used in UE function event- { -100..100 }
reporting. The parameter is
used both for signaling over
RRC and RNSAP

Cell reselection hysteresis


used in UE functions in idle
qHyst1 and connected mode. Value 0..40
launched by System
information (SIB3)
The hysteresis value of the
serving cell.
qHyst2 Used to perform cell ranking 0..40
for the serving cell

The DRX cycle length


coefficient (k) for UEs in
URA_PCH.
The DRX cycle length is the
frequency with which the UE
listens on the paging
utranDrxCycleLength channel. The parameter is 3..9
applicable for both UTRAN
and CN initiated paging in
URA_PCH.

Value mapping
Weight factor to include
active set cells other than
the best in evaluation
criteria for event 1a.
w1a Used by UE functions for 0..20
intra-frequency
measurement reporting (in
CELL_DCH)
Signal strength offset
between source and target
cells.

Dependencies:
Used when the IE
qOffset1sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/12 is set to "CPICH
RSCP". This is configured
through
UtranCell::qualMeasQuantit
y
Signal strength offset
between source and target
cells. used when the IE
qOffset2sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/22 is set to "CPICH
Ec/No".
Maximum number of cells in
active set.
The reporting deactivation
threshold, used to control
intra-frequency
maxActiveSet measurements (event 1a), is 2..4
set to maxActiveSet - 1.
The replacement activation
threshold, used to control
intra-frequency
measurements (event 1c)
Signal strength offset
between source and target
cells.

Dependencies:
Used when the IE
qOffset1sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/12 is set to "CPICH
RSCP". This is configured
through
UtranCell::qualMeasQuantit
y
Signal strength offset
between source and target
cells. used when the IE
qOffset2sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/22 is set to "CPICH
Ec/No"

The decision on when


sIntraSearch measurements on intra- 0..27
frequencies shall be
performed
The decision on when
measurements on inter-
sInterSearch 0..27
frequencies shall be
performed

Weight factor to include


active set cells other than
the best in evaluation
criteria for event 1a.
Used by UE functions for
intra-frequency
w1a measurement reporting (in 0..20
CELL_DCH).

Change takes effect:


Ongoing connections (next
switch to CELL_DCH
UL/DL RLC buffer threshold
for upswitching from
FACH/RACH to dedicated ulRlcBufUpswitch:8..8
channel. 16..16 32..32 64..64
When the RLC buffer load in 128..128 256..256 512..512
ulRlcBufUpswitch/dlRlcBufU
pswitch the uplink exceeds this 1024..1024 2048..2048
threshold, a measurement 3072..3072 4096..4096
report is sent from the UE. 6144..6144 8192..8192
An upswitch request is dlRlcBufUpswitch:0~2000
issued upon reception of the
measurement repor

None None None

None None None

None None None

None None None

None None None


None None None

None None None


None None None

None None None


None None None

None None None


None None None

None None None

None None None


None None None

None None None


None None None

None None None


None None None

None None None


None None None

None None None

None None None


None None None

None None None


None None None

None none none

None None None


None None None

None None None


None None None

None None None


None None None

None None None


None None None

None None None

None None None

None None None

None None None


None None None

None None None

None None None


None None None

None None None


None None None

None None None


None None None

None None None


None None None

None None None

None None None


None None None

None None None

None None None


None None None

None None None

None None None

None None None


None None None

None None None


None None None

None None None

None None None


None None None

None None None


Maximum time for Call Re-
establishment of CS RABs.
Controls a UE timer that is
started at detection of a RL
Failure. At expiry of the
timer, no more attempts to
reestablish the CS RAB may t314 = 12 { 0, 2, 4, 6, 8, 12,
T314 be initiated by the UE. 16, 20 }
Only used when
RncFeature=CallReestablish
ment is activated. When
RncFeature=CallReestablish
ment is deactivated, IE T314
is hard-coded to 0.
Maximum time for Call Re-
establishment of PS RABs.
Controls a UE timer that is
started at detection of a RL
Failure. At expiry of the
timer, no more attempts to
reestablish the PS RAB may
t315 = 10 { 0, 10, 30, 60,
be initiated by the UE.
T315 Only used when 180, 600, 1200, 1800 }
RncFeature=CallReestablish
ment is activated. When
RncFeature=CallReestablish
ment is deactivated, IE T315
is hard-coded to 0.
None None None

None None None

None None None


Number of frames to be
nOutSyncInd considered for out-of-sync 1..256
detection
Number of frames to be
considered for in-sync
detection.
nInSyncInd 1..256
Dependencies:
(nInSyncInd * 10 ms) <
rlFailureT

Guard period before sending


RL Failure.

Dependencies:
rlFailureT rlFailureT > (nInSyncInd * 10 0..255
ms)

Unit: 0.1 s
None None None

None None None

None None None


None None None

None None None

None None None

None None None


None None None

None None None


None None None

None None None

None None None

None None None

None None None


None None None
None None None
None None None
None None None

None None None


NONE NONE NONE

NONE NONE NONE


NONE NONE NONE

NONE NONE NONE

NONE NONE NONE


NONE NONE NONE
NONE NONE NONE
NONE NONE NONE
NONE NONE NONE
NONE NONE NONE
NONE NONE NONE
NONE NONE NONE

NONE NONE NONE

NONE NONE NONE

None None None


None None None

None None None

None None None


None None None

None None None


None None None

None None None


None None None

None None None


None None None

None None None

None None None

None None None

None None None

None None None

None None None

Indicates if the RNC


supports IFHO. FALSE = 0
fddIFHOSupp
Takes effect: Ongoing TRUE = 1
connections
Feature state for licensed
feature 'SRB on HSDPA' (F-
DPCH + SRB on HSDPA),
indicating if the feature is
ACTIVATED or DEACTIVATED
for this cell.

Possible values:
• ACTIVATED
• DEACTIVATED

Dependencies: Can only be


featureStateFDpchSrbOnHsd DEACTIVATED = 0
pa set to ACTIVATED in case a ACTIVATED = 1
valid license key is installed
for the feature, that is, if
NodeBFunction::licenseState
FDpchSrbOnHsdpa =
ENABLED. If the value is
ACTIVATED when the license
state changes from
ENABLED to DISABLED a
corresponding License Not
Valid alarm is generated.
Takes effect: For new
connections.

EDCH_2MS_TTI_NON_CAPA
BLE = 0
EDCH_2MS_TTI_CAPABLE =
1
Shows whether the cell is E-
DCH 2 ms TTI capable or not.

Possible values:
• EDCH_2MS_TTI_CAPABLE
eDch2msTtiCapability •
EDCH_2MS_TTI_NON_CAPA
BLE

Specification: 3GPP TS
25.433, NBAP, UTRAN Iub
interface NBAP signalling
Feature state for licensed
feature 'EUL 2 ms TTI',
indicating if the feature is
ACTIVATED or
DEACTIVATED.
Possible values:
• ACTIVATED
• DEACTIVATED
featureStateEul2msTti Dependencies: Can only be DEACTIVATED = 0
ACTIVATED = 1
set to ACTIVATED in case a
valid license key is installed
for the feature, that is, if
NodeBFunction::licenseState
Eul2msTti = ENABLED. If the
value is ACTIVATED when
the license state changes
from ENABLED to DISABLED
a corresponding License Not
Valid alarm is generated.

None None None

None None None

NONE NONE NONE


NONE NONE NONE

None None None

None None None

None None None


None None None

None None None

None None None

None None None

None None None

None None None

None None None

None None None

None None None


None None None
Time after which a
connection with low
throughput is downswitched
from HS-DSCH to
CELL_FACH. If CELL_FACH
state is not available, the
connection is downswitched
to IDLE state.
Once the throughput on
both the uplink and
downlink has fallen below
the value of
hsdschInactivityTimer
ChannelSwitching::downswit { -1, 1..255, 7200 }
chTimerThreshold, a
downswitch to FACH/RACH
is normally requested after
this length of time.
However, the downswitch is
not requested if the
throughput has
subsequently increased
above the value of
ChannelSwitching::downswit
chTimerThreshold.
purposes:
- The network uses it to
indicate that the Fast
Dormancy Handling feature
is supported.
- The UE uses it to limit the
frequency ar which the UE
sends Signalling Connection
Release Indication
messages.

The timer is started in the


UE when transmitting a
SIGNALLING CONNECTION
RELEASE INDICATION
message that includes the IE
Signalling Connection
{ 0, 5, 10, 20, 30, 60, 90,
T323 Release Indication Cause. 120 }
When T323 expires, the UE
may determine whether
there have been any
subsequent indications from
upper layers that there is no
more PS data for a
prolonged period, in which
case it triggers the
transmission of a single
SIGNALLING CONNECTION
RELEASE INDICATION
message.

The use of 0 seconds


indicates no need to apply
the timer.
Time after which a
connection in URA_PCH
state is switched down to
InactivityTimerPch IDLE state, if no upswitches
have been subsequently { 0…..240 }
(RNC级)
requested.
None None None

None None None

None None None

None None None

None None None


None None None

None None None

None None None

None None None

None None None


None None None

None None None


downswitchThreshold:
Throughput threshold for
downswitching from
dedicated channel to
FACH/RACH.
Once the throughput on
both the uplink and
downlink has fallen below
this threshold, a downswitch
downswitchThreshold to FACH/RACH is normaly
requested after the length
of time set in
downswitchTimer. However,
the downswitch is not
requested if the throughput
has subsequently increased
above the value of
downswitchTimerThreshold.

None None None

None None None

None None None


None None None
None None None
None None None
None None None
None None None
None None None
Time after which an inactive
connection in CELL_FACH
state is downswitched to
URA_PCH state.
When both the downlink
and uplink throughput have
been 0 kbps (meaning no
data has been transmitted)
for this length of time, a
downswitch from
CELL_FACH to URA_PCH { -1, 1..1440 }
inactivityTimer
state is requested. If
URA_PCH state is not
available, the UE is
downswitched to IDLE state.

Special values:
-1: the value of
ChannelSwitching::inactivity
Timer is used

None None None

None None None

None None None

None None None

Number of preconfigured
subsequent transmissions of { 1..5 }
noOfPagingRecordTransm the same Paging Record.

None None None


Minimum required
(acceptable) quality level in
the cell (dB). Used to set cell
border between two cells.
Used in UE functions for cell
selection/reselection in idle
mode and connected mode.

qQualMin (MO Class Special values:


Name:vsDataExternalUtranC 100: Indicates that the -24..0,100..100
ell) minimum quality level has
not been specified by the
operator. The parameter is
then not
present in SIB11 for this
neighbor. The UE will use
the serving cell value
(UtranCell MO value)
instead
Minimum required
(acceptable) RX level in the
cell. (dBm).
Used in UE functions for cell
selection/reselection in idle
mode and connected mode.
Value launched by System
information (SIB11) for each
intra-frequency
measurement object
corresponding to adjacent
cells of serving cell.
qRxLevMin (MO Class
Values below -115 dBm are
Name:vsDataExternalUtranC only used by the system if a -119..-25,100..100
ell)
valid license key exists.
Special values:
100: Indicates that the
minimum Rx level has not
been specified by the
operator. The parameter is
then not present in SIB11 for
this neighbor. The UE will
use the serving cell value
(UtranCell MO value)
instead

Signal strength offset


between source and target
cells.
Dependencies:
Used when the IE
qOffset1sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/12 is set to "CPICH
RSCP". This is configured
through
UtranCell::qualMeasQuantit
y
Signal strength offset
between source and target
cells. used when the IE
qOffset2sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/22 is set to "CPICH
Ec/No".

This offset is added to the


measured quantity before
the UE evaluates if an event
has occurred.
Used in UE function event-
individualOffset -50..50
reporting. The parameter is
used both for signaling over
RRC and RNSAP.

Unit: dB

This offset is added to the


measured quantity before
the UE evaluates if an event
has occurred.
individualOffset Used in UE function event- { -100..100 }
reporting. The parameter is
used both for signaling over
RRC and RNSAP
This offset is added to the
measured quantity before
the UE evaluates if an event
has occurred.
Used in UE function event-
individualOffset reporting. The parameter is { -100..100 }
used both for signaling over
RRC and RNSAP.

Unit: Db

This offset is added to the


measured quantity before
the UE evaluates if an event
has occurred.
individualOffset { -100..100 }
Used in UE function event-
reporting. The parameter is
used both for signaling over
RRC and RNSAP
Signal strength offset
between source and target
cells.

Dependencies:
Used when the IE
qOffset1sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/12 is set to "CPICH
RSCP". This is configured
through
UtranCell::qualMeasQuantit
y
Signal strength offset
between source and target
cells. used when the IE
qOffset2sn "cell_selection_and_reselec -50..50
tion_quality_measure" in
SIB 11/22 is set to "CPICH
Ec/No"

This offset is added to the


measured quantity before
the UE evaluates if an event
has occurred.
individualOffset Used in UE function event- -50..50
reporting. The parameter is
used both for signaling over
RRC and RNSAP
ESN Original Network Value
Mapping result final value in swap Mapping result Remark

70~95 SF32(SF32)

NOT_RESERVED(不保
0(587)/1(645) maping
留),RESERVED

0 NOT_BARRED maping
0 NOT_BARRED maping

0 NOT_BARRED maping
0 NOT_BARRED maping

0 NOT_BARRED maping
0 NOT_BARRED maping

0 NOT_BARRED maping
0 NOT_BARRED maping

0 NOT_BARRED maping
0 NOT_BARRED maping

0 NOT_BARRED maping
0 NOT_BARRED maping

0 NOT_BARRED maping
0 NOT_BARRED maping

0 NOT_BARRED maping
0 NOT_BARRED maping

91 maping

160(519)/500(713) 200
[10~96] 96

not found 40
-31 -31 maping

-7 -7 maping

-6 -6 maping

maxFach1Power=18&30/ma
xFach2Power=15&30 use smartRNO mapping maping
-4 -4 maping

-18 -18 maping

-35 -35 maping

8 8 maping

3 3 maping
-27 -27 maping

-4 -4 maping
[1.5,2.5]
80 maping
=(460/350-330/240-80)/10

8 D8 maping

0 (OFF) 0
not found ALLOWED maping

not found mode2 maping

not found 0 maping

not found 0 maping

not found 0 NO HSPA+

not found 0 maping

not found 0 NO HSPA+


not found 0 maping

not found 0 maping

0 (OFF) 0 maping

not found Automatic /Manual maping

1(52)/3(576) 3 maping
not found 5,10 maping

1(2)/5(103)/10(522) 5,10 maping

4 4 maping
3 D30 maping
dchRcLostT=50 /
hsDschRcLostT=100 11000

64 D32 maping
64 D16 maping
SigChType=DCH_13.6K_SIGN
ALLING

0 0 maping

not found 0 maping


ulRlcBufUpswitch=256/dlRlc
BufUpswitch=500 D512 maping

not found 1
1 (TRUE) 1 maping

20 1
100(957)/-105(1) [-53,-47] maping
2 2 maping
-18 -18 maping

-18 -18,QqualminInd=False maping


-18
-58
0 127 maping
0(1228)/9(4) 127 maping
4(1230)/8(2) 2 maping

timeToTrigger2dEcno=320/ti
meToTrigger2dRscp=320 D320 maping
timeToTrigger2fEcno=1280/ D1280 maping
timeToTrigger2fRscp=1280

rabindex参数配置无法提取 -11,-9 maping


timeToTrigger2dEcno=320/ti
meToTrigger2dRscp=320 D320 maping
timeToTrigger2fEcno=1280/
timeToTrigger2fRscp=1280 D1280 maping
5 D80 maping
5 D80 maping
rabindex参数配置无法提取 -11,-9 maping
rabindex参数配置无法提取 -11,-9 maping
rabindex参数配置无法提取 -99,-97 maping
-95 16 maping
-95 16 maping
-95 16 maping
5 5 maping
5 5 maping
5 5 maping
0 0 maping

0 0 maping
15 8

timeToTrigger2dEcno=320/ti
meToTrigger2dRscp=320 D320

timeToTrigger2fEcno=1280/ D1280
timeToTrigger2fRscp=1280
usedFreqThresh2dEcno=[-
11]/serviceOffset2dEcno=0 -14

usedFreqThresh2dEcno=[-
11,-
9]/serviceOffset2dEcno=0/u -12
sedFreqRelThresh2fEcno=2
usedFreqThresh2dEcno=[- -14
11]/serviceOffset2dEcno=0

usedFreqThresh2dEcno=[-
16,-
9]/serviceOffset2dEcno=-
2&0 -14
IfIratMobilityHsdpaEul=0&1
(DEACTIVED&ACTIVED)
usedFreqThresh2dEcno=[-
11,- -12
9]/serviceOffset2dEcno=0/u
sedFreqRelThresh2fEcno=2

usedFreqThresh2dEcno=[-
16,-
9]/serviceOffset2dEcno=-
2&0 -12
IfIratMobilityHsdpaEul=0&1
(DEACTIVED&ACTIVED)
usedFreqThresh2dRscp=[-
-95
100]/serviceOffset2dRscp=0

usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0 -92
/usedFreqRelThresh2fRscp=
2
usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0 -95

usedFreqThresh2dRscp=[-
109,-
97]/serviceOffset2dRscp=0&
-4 -95
IfIratMobilityHsdpaEul=0&1
(DEACTIVED&ACTIVED)
usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0 -92
/usedFreqRelThresh2fRscp=
2

usedFreqThresh2dRscp=[-
109,-
97]/serviceOffset2dRscp=0&
-4 -92
IfIratMobilityHsdpaEul=0&1
(DEACTIVED&ACTIVED)
timeToTrigger2dEcno=320/ti
meToTrigger2dRscp=320 D320
timeToTrigger2fEcno=1280/
timeToTrigger2fRscp=1280 D1280
usedFreqThresh2dEcno=[-
11]/serviceOffset2dEcno=0 -14
usedFreqThresh2dEcno=[-
11,-
9]/serviceOffset2dEcno=0/u -12
sedFreqRelThresh2fEcno=2
usedFreqThresh2dEcno=[-
11]/serviceOffset2dEcno=0 -15
usedFreqThresh2dEcno=[-
16,-
9]/serviceOffset2dEcno=-
2&0 -15
IfIratMobilityHsdpaEul=0&1
(DEACTIVED&ACTIVED)
usedFreqThresh2dEcno=[-
11,-
9]/serviceOffset2dEcno=0/u -13
sedFreqRelThresh2fEcno=2
usedFreqThresh2dEcno=[-
16,-
9]/serviceOffset2dEcno=-
2&0 -13
IfIratMobilityHsdpaEul=0&1
(DEACTIVED&ACTIVED)
usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0 -100

usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0
/usedFreqRelThresh2fRscp= -97
2
usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0 -110
usedFreqThresh2dRscp=[-
109,-
97]/serviceOffset2dRscp=0&
-4 -110
IfIratMobilityHsdpaEul=0&1
(DEACTIVED&ACTIVED)

usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0
/usedFreqRelThresh2fRscp= -107
2
usedFreqThresh2dRscp=[-
109,-
97]/serviceOffset2dRscp=0&
-4 -107
IfIratMobilityHsdpaEul=0&1
(DEACTIVED&ACTIVED)
-95 16
-95 16
-95 16 maping
3 6
3 6
3 6
5 12
5 12
5 12
0 0

0 0
15 8

11 D320
12 D640
640 D640
3 D4000
3 D4000

2 8
11 D640
D4000
3 D4000

2 8
11 D640
RABINDEX级的参数无法提
-9, maping

-9 maping
RABINDEX级的参数无法提
-9 maping

RABINDEX级的参数无法提
-95 maping

RABINDEX级的参数无法提
-95 maping

RABINDEX级的参数无法提
-95 maping

2 2 maping

2 2 maping
1 1 maping

1 (TRUE) 1 maping

1 (TRUE) 1 maping
0 0 maping
3 3 maping
2&4 1&2 maping
4 2 maping

10&40 10&40 maping


5 6 maping

0 0 maping

-50..50 -50..50 maping


0 0 maping

-50..50 -50..50 maping

[1,6] [1,6] maping


new plan

new plan
0 0 maping
0 0 maping
0 0 maping
0 0 maping
640 D640
0 4
0 4
0 4
0 4
2 D2 maping
CPICH_EC/NO

D16

D16
2 D2 maping
CPICH_EC/NO

D16

D16
-12
-12
-12 maping
-92
-92
-92 maping

10 4
0 0

100 D0
usedFreqThresh2dEcno=[-
11,-
9]/serviceOffset2dEcno=0/u -12
sedFreqRelThresh4_2bEcno
=-1

usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0
-92
/usedFreqRelThresh4_2bRsc
p=-3
usedFreqThresh2dEcno=[-
11,-
9]/serviceOffset2dEcno=0/u -12
sedFreqRelThresh4_2bEcno
=-1

usedFreqThresh2dEcno=[-
11,-
9]/serviceOffset2dEcno=0/u -12
sedFreqRelThresh4_2bEcno
=-1
usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0 -92
/usedFreqRelThresh4_2bRsc
p=-3

usedFreqThresh2dRscp=[-
100]/serviceOffset2dRscp=0
-92
/usedFreqRelThresh4_2bRsc
p=-3
0 4
0 0
4 4

5 1
1 4

8 1
0 0 maping

2&4 2
4 1

5 6 maping
0 0
0 0
-50..50 0
3 3
0 0
-50..50 0

0 5
4
0(1228)/9(4)

0 0
ulRlcBufUpswitch=256/dlRlc
BufUpswitch=500 D512 maping

None D64

None D384

None 1024

None 1

None 1
None 1

None 8
None 1

None ON
None NO

None RateDegrade
None RateDegrade

None NO

None 10000
None 10000

None 10000
None 1

None D16
None D32

None D8
None D1000

None D8k

None 1
None ON

None ON
None 1

None 10000

None 15000
None D120

None 1
None 10000

None 10000
None 0

None 4
None 1

None D8

None 1

None 1

None 1
None FALSE(否)

None 1

None 1
None 10

None 1
None 1

None 1
None 1 maping

None 1 maping
None 1 maping

None 1 maping

None 1 maping
None 1 maping

None 1 maping

None 1 maping
None 1 maping

None 1 maping

None 1

None 1 maping
None 1 maping

None 1 maping
None 1 maping

None 15000

None 35000
None 3 maping

None D20 maping


空值 8 maping
空值 0 maping
None D1400 maping

None 3 maping

None D20/D1 maping


10 8 maping
D5 maping

10 10 maping
featureState=0、licenseStat 0 maping
e=1、serviceState=0

0 (DEACTIVATED) 0 maping

LOOSE_CAC
None
None 1

None 1

None 0

None 1
None ALGORITHM_SECOND

None ALGORITHM_FIRST
None D50

None 0

None 0

None 0

None 0
None 10
None 0
None D1000
None 0

None 1
None 1

None 1
None 1

None 1

None SF64(SF64)
None SF128(SF128)
None LOOSE_CAC
None 5
None 5
None 0
None ON
None ON

None 0

None ON

UUtranCell提取值为[-115,- FALSE maping


111]
UUtranCell提取值为[-115,- None maping
111]

None 1

None DCH8KHSDPA
None 0

None 1
None 60

None 60
SET
UCORRMALGOSWITCH:Logic
RncId=xxx,DraSwitch2
=DRA_PS_STATE_TRANS_W
HEN_CS_REL_SWITCH=1;
None SET
UCOIFTIMER:LogicRncId=xxx
,ZeroRateUpFailToRelTimerL
en
=180;

None 1
None D20

None D20

None 1

None 1

None 1

None 1

None 1

1 (TRUE) 1 maping
not found DCH maping

edchTti2Support=[1048(OFF 0 maping
),4(ON)]
0 maping

None D8

None D8

None OFF
None 1

None 1

None 50

None 0
None 10s

None 30

None 1

None 1

None MaxHsupaUserNum=40,ER
GCHEHICHCODENUM=2.

None 0,1 maping

None 0,1 maping

None 0,1 maping

None 0,1 maping


None 0,1 maping
空值 4
5 D5 maping

25&29 1500&1740 maping


None Limited

SET
None UUESTATETRANS:BasedTime
F2DThd=28,BasedTimeF2DP
T=30;

SET UCORRMALGOSWITCH:
CmpSwitch2=CMP_F2D_RLC
None _ONESIDE_REBUILD_SWITC
H-1;

SET UCORRMALGOSWITCH:
CmpSwitch=CMP_D2F_RLC_
None
ONESIDE_REBUILD_SWITCH-
1;

None 0
SET UCORRMALGOSWITCH:
DraSwitch2=DRA_PCPICH_E
None CN0_ON_RACH_UPDATE_S
WITCH-1;

None SET UFRC: FakeEcNo=29;

SET UCORRMPARA:
PerfEnhanceSwitch=PERFEN
None H_HSUPA_TTI_RECFG_PROC
_OPT_SWITCH-1;

SET
UNBMPARA:PerfEnhanceSwi
None tch=PERFENH_HRNTI_OPT_S
WITCH-1; (R15/R16)

None 0
None 0 maping

None 0 maping
0 0 maping

None D512 maping

None D512 maping

None D0
None D0
None D0
None D1000
None D1000
None 4
None 30
空值 10 maping

None 1

None 1

None 8

None 1

2 1 maping

None 1

5
-18 baseline
-58,QrxlevminInd=False baseline

0 0 mapping
[-50,50] [-50,50] mapping

0 0 mapping

0 0 mapping
0 0 mapping

0 0 mapping
0 0 mapping
[-50,50] 0 mapping

0 0 mapping
to
DYNAMIC_BW_SHA
PING, flow
allocation for HSDPA
Type
usersof channel that
is performed
preferably
according
Parameterto carries
the
Network Element Parameter ID Parameter Name the
delaysignaling
and packet RB. -
Description
DCH: Both
loss of the uplink
and downlink
Indicates
transmission are
the HSDPA
NodeB SM Scheduling Method preferably
Scheduling carried
Method
interface board
Indicates the powerin
on
of DCH.
the - HSDPA:
SIMPLE_FLOW_CTRL
HS-SCCH is an
NodeB SWITCH Cabinet No Uplink
mode inis dBpreferably
offset to the
carried
transmitonpower
Indicates DCH,
the and
HS-of
NodeB SCCHPWR downlink is
HS-SCCH Power the PCPICH.
SCCH Power Control
HSSCCHPWRCMIND Control Method in preferably
Method in carried
CELL DCH
NodeB CELL DCH state on HS-DSCH. -
state
CH IndicatesUplink
the is
HSUPA:
Indicates
16QAM Switch.
preferably the Power
carriedThe
NodeB PWRMGN Power Margin Margin Ratio
Indicates
function
on the
E-DCH,will andbe
Dynamic Code Dynamic
maximum
enabled
downlink ifCode
power
isthis
NodeB DYNCODESW Switch Switch
used for scheduled
parameter
preferably is set to
carried
users
OPEN.
on after
DCH.When
- thethis
HSPA:
CELL EXTRAPOWER EXTRAPOWER scheduling
switch
Uplink turned on,
is preferably
the cell on
carried throughput
E-DCH,
CELL CME16QAMSW 16QAM Switch improves
Type of Channel and downlink is
Preferably Carrying preferably carried
RNC SrbChlType
PERFENH_SRB_OVE Signaling RB
PERFENH_SRB_OVE on HS-DSCH
PERFENH_SRB_OVE
RNC R_HSUPA_TTI10_S R_HSUPA_TTI10_S R_HSUPA_TTI10_S
WITCH WITCH WITCH
STATIC_BW_SHAPIN
G(静态流量成形),
DYNAMIC_BW_SHA
PING(动态流量成形
),
Recommend
MML Command EPF(Enhanced
NO_BW_SHAPING(PF), Use base line ESN Parameter ID
Parameter Range
SET PF(PF),
无流量成形), RR(Round
ULOCELLMACHSPAR Robin), MAXCI(Max BW_SHAPING_ONO
BW_SHAPING_ONO
A C/I) EPF(增强PF) null
FF_TOGGLE(BW_SH
SET FF_TOGGLE(自选择 APING_ONOFF_TOG
DLFLOWCTRLPARA 流量成形) GLE) null
SET
ULOCELLMACHSPAR CQI(基于CQI的自适
A
SET 0~80 28 null
ULOCELLMACHSPAR 应功控),
A FIXED(功率固定) CQI null
DCH(上行DCH,下
SET MACHSPARA 行DCH),
0~100 HSDPA(上 5 null
行DCH,下行
OPEN(开), CLOSE(关
null
SET MACHSPARA )HSDSCH), HSUPA(上 OPEN
ULOCELLMACHSPAR
行EDCH,下行 0 null
SAET 0~40
ULOCELLMACHSPAR DCH), HSPA(上行
A OPEN, CLOSE DCH(上行DCH,下
OPEN null
EDCH,下行
SET HSDSCH) 行DCH)
UFRCCHLTYPEPARA null

SET UCORRMPARA null


0,1 0
ESN Parameter ESN Original
ESN Meaning Mapping result final
Value Range Network Value

null null null EPF


BW_SHAPING_ONO
FF_TOGGLE(BW_SH
null null null APING_ONOFF_TOG
GLE)
null null null 28

null null null CQI

null null null

null null null OPEN

null null null 0

null null null CLOSE,OPEN(1)

null null null DCH

null null null 0


Mapping result
remark

use baseline

use baseline

use baseline

use baseline

use baseline

use baseline

use baseline

use baseline

use baseline

use baseline
used to select a
feature
This related to
parameter is
HSPA+.
used to Ifselect
a feature a is
selected,
feature it
related
This parameter is indicates
to
that
usedthe
HSPA+. to Ifselect
a feature a is
corresponding
selected,
feature it indicates
related to
This parameter
algorithm is
Huawei
that
The
HSPA+.
used the
parameter
to If aisfeature
select
enabled.
a is
If a feature
corresponding
specifies
selected, the
it isnumber
not
indicates
feature
This related
parameter
selected, to
is
itisindicates
Network algorithm
of
thatHS-DPSCH
Parameter
HSPA+. the If a enabled.
codes.
feature is
Parameter ID Parameter Name used
that
If to select
the is not
a feature a
Element Description
This parameter
corresponding
selected,
feature it
related is
indicates
to
Cell Hspa Plus function This
valid parameter
corresponding
selected,
algorithmonly itwhen is
indicates
isfeature
enabled.
that
HSPA+.
used the
algorithmto If a
selectis a
disabled. is
Cell DL_L2ENHANCED switch that
Allocate
If the Code
a feature
corresponding Mode is
is not
selected,
feature
Note that it
related indicates
toFor
Cell Hspa Plus function corresponding
set tothe
selected,
algorithm
that itother
"Manual". indicates
isfeature
enabled.
HSPA+.
factors
algorithm
detailed
that If
such a is
the information as license
disabled. is
Cell E_FACH switch If a feature
corresponding
selected, it is not
indicates
and
Note
about the
that physical
thisitother
Cell Hspa Plus function corresponding
selected,
algorithm
that
factors the
capability such isparameter,
of indicates
enabled.
NodeB
as
Cell 64QAM switch refer
algorithm
that
If a to
the
feature 3GPP TSlicense
isisdisabled.
not
corresponding
restrict
and
25.308
Note the
that whether
physical
other a
Cell Hspa Plus function corresponding
selected,
algorithm
feature can itis indicates
enabled.
be used
capability
factors
algorithm such of NodeB
as
isfeaturelicense
Cell MIMO switch that
If
even
restrict
and
the
a feature
if this
the whether
physicalisdisabled.
nota is
Note
selected,
selected.thatit
corresponding other
The indicates
Cell Hspa Plus function feature
capability can of be used
NodeB
Cell 64QAM_MIMO switch factors
algorithm
that the
EFACH/MIMO such is as license
disabled.
switch
even
restrict
Maximum
and if
the this
whether feature
number
physical a ofis
Cell Hspa Plus function Note that
corresponding
determines
selected. other
The whether
feature
users
capability
factors can
supported
such of be used
NodeB
as by
license
Cell DC_HSDPA switch algorithm
the cell
EFACH/MIMO
even if this isfeature
supports disabled.
theis
switch
the
and
Note HSDPA
restrict
Maximumthe
that whether channel.
number
physical
other a of
E-FACH/MIMO
determines
selected.
The user The
in whether
this
Cell Hspa Plus function feature
users
capability
factors
feature can
supported
such be
butofrefers used
NodeB
as
does by
license
not
Cell DCMIMO_HSDP If
theE_F_DPCH
cell
EFACH/MIMO
parameter
even if supports
this are the
switch
feature tois
switch the
and
affect HSUPA
restrict
the
selected, thewhether
physical
the channel. a
E-FACH/MIMO
determines
the user
selected.
The usercan with
The
in whether
thisservices
Cell Hspa Enhanced feature
capability
establishment
corresponding
feature be
butofrefers
does used
NodeB
of the
not
Cell E_F_DPCH_ON the
on cell
the
EFACH/MIMO
parameter
even if supports
HSDPA
this the
switch
feature tois
function switch restrict
E-FACH
function
affect
E-FACH/MIMO whether
and
will
thewith the
be a
channel,
determines
the
When
featureuser
selected. the regardless
can The whether
switch services
be ofusedis of
MIMO
MAP_HSUPA_TTI_2M Service Mapping Strategy enabled;
establishment
feature
the numbercell
butotherwise,
does
of RABs the
not
RNC S_SWITCH Switch
on
even 2cell
the
EFACH/MIMO
on,
disabled
E-FACH ifms supports
HSUPA
TTIfeature
this
and the
theis
is switch
affect
carried
E-FACH/MIMO
channel, theon the
regardless HSDPA
determines
supported
selected.
MIMO
establishmentcell The of theof
whether
for HSUPA
Maximum HSDPA user channel.
feature
the number
cell
EFACH/MIMO Maximum
but
supports does not
of switch
RABsthe
Cell MaxHsdpaUserNum E-FACH andthe the
number HSDPA
affect
carried
E-FACH/MIMO
determines user
theon number
HSUPA
whether
Maximum HSUPA user MIMO
cannot
establishment
channel.
feature cell
exceed
Maximum
but does the
of the
not
Cell MaxHsupaUserNum number the cell supports the
HSDPA
E-FACH/MIMO of
E-FACH
HSUPA
affect capability
and
user
the the
number
the
MIMO
cannot NodeB
establishment
feature butproduct,
cell
exceed does the
of theIn
not
practice,
HSUPA
E-FACH
affect the and the ofcan
the
capability value
be
the
MIMOsetNodeBbased
establishmentcell product,onofthetheIn
cell type
practice, and
E-FACH and the can
the the
value
richness
be
MIMOset based of the
cell on the
available
cell type and HSDPA the
power and
richness of codethe
resources.HSUPA
available
power and code
resources
Ericsson

MML Command Use base line ESN Parameter ID Feature


ESN Meaning state for
licensed feature
ADD featureStateEnhanced 'Enhanced Layer 2',
UCELLALGOSWITCH Layer2 indicating if the
Used
feature to isactivate
ACTIVATED and
ADD
featureStateHsFach deactivate
or DEACTIVATED. the feature
UCELLALGOSWITCH HS-FACH
Indicates in the cell.is
if 64QAM
ADD featureState64Qam enabled or not for the
UCELLALGOSWITCH
RBS
Indicates if MIMO is
ADD The maximum
UCELLALGOSWITCH featureStateMIMO enabled or not in the
Support
number
RBS 64QAM
of Serving
ADD featureState64QamMi EUL
and MIMO
users allowed per
UCELLALGOSWITCH mo Combination on cell
cell.
ADD level
Support of Multi
UCELLALGOSWITCH featureStateHsdpaMc Precondition:
Carrier on cellIflevel
Supportkey of Multi
ADD featureStateHsdpaMc license
Capability
Carrier with
'Number
information
MIMO on
UCELLALGOSWITCH Mimo of EUL Users
indicating per Cell'
if F-DPCH is
cell
is level
enabled (see
ADD supported in the cell
UCELLALGOSWITCH fdpchSupport NodeBFunction::licens
as reportedlimit by RBS
SET Admission
eStateNumEulUsers),
Indicates whether for2in
RSI
edchTti2Support(MO: the and
numberAudit of usersin
UCORRMALGOSWITC 0 and
ms Licensing
TTI
response.is supported
Eul) assigned
Emergency to the
UnlockHS-is
H the RBS or not.
PDSCH/HS-SCCH
not activated, in
ADD UCELLCAC 64 hsdpaUsersAdm
the cell. This limit is
maxNumEulUsers can
applicable
not be set to both to
a higher
ADD UCELLCAC 20 maxNumEulUsers HSDPA
value thanRABthe setup and
license
to channel switching.
key allows. If the
license key is
disabled, maximum 4
EUL users are allowed
per cell. If Licensing
Emergency Unlock is
activated, maximum
96 EUL users are
allowed per cell.
Takes effect: Increase
takes effect
immediately.
Decrease takes effect
gracefully (starving
out resources).
Ericsson Mapping result

ESN Parameter Value ESN Original Network


Range Value final value in swap remark
DEACTIVATED = 0 0/1 0/1 mapping
ACTIVATED = 1
DEACTIVATED = 0
0 0 mapping
ACTIVATED = 1
DEACTIVATED = 0 0/1 0/1 mapping
ACTIVATED = 1
DEACTIVATED = 0
ACTIVATED = 1 0 0 mapping
DEACTIVATED = 0 0 0 mapping
ACTIVATED = 1
DEACTIVATED = 0
ACTIVATED = 1 0 0 mapping
DEACTIVATED = 0 0 0 mapping
ACTIVATED = 1
DEACTIVATED = 0
ACTIVATED = 1 0 0 mapping
OFF = 0
ON = 1 0 (OFF)/1(ON,4cell) 0 (OFF)/1(ON,4cell) mapping

0..1000 [10,96] 96 mapping

1..96 4/16/32 40 mapping

You might also like