SSS Parallel Series Scheme A 1V/1T 5B5-01: Neck Middle Bridge

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Scheme No B002 : Last Updated Jul 2018

© Free-Way 2018

REVERSE VIEW OF PICKUPS, SWITCH AND POTENTIOMETERS.

FREE-WAY
5B5-01
Hot
Hot Hot
Grd
Grd Grd

NG NH OP GD B A MH BG BT BH

GROUND WIRES TO CAVITY


NECK MIDDLE BRIDGE SHIELD & SPRING CLAW

FRONT VIEW OF PICKUPS AND SWITCH FRONT VIEW OF PICKUPS AND SWITCH
V

10 5 RING

TIP
IN SERIES N

9 4

NG

O H
N
P
M + N

D
IN PARALLEL

G
No

B
te
8 3 : te

M A
rm

BG H
ina
lA

BT
is
no
IN SERIES M tu

BH
se
d .
7 2 T

IN PARALLEL B + M

6 1
Refer to Free-Way Blade Installation Instructions
Switch metalwork is assumed to be grounded by shielding on
IN SERIES B reverse of scratch-plate which is assumed grounded via the potentiometers

Model No:-
5B5-01 SSS Parallel Series Scheme A 1V/1T
Scheme No B004 : Last Updated Jul 2018
© Free-Way 2018

REVERSE VIEW OF PICKUPS, SWITCH AND POTENTIOMETERS.

FREE-WAY
5B5-01
Hot
Hot Hot
Grd
Grd Grd

NG NH OP GD B A MH BG BT BH

GROUND WIRES TO CAVITY


NECK MIDDLE BRIDGE SHIELD & SPRING CLAW

FRONT VIEW OF PICKUPS AND SWITCH FRONT VIEW OF PICKUPS AND SWITCH
V

10 5 RING

TIP
IN SERIES N

9 4

NG

O H
N
P
M + N

D
IN PARALLEL

G
B
8 3

M A
BG H
BT
IN SERIES M

BH
7 2 T

IN PARALLEL B + M

6 1
Refer to Free-Way Blade Installation Instructions
Switch metalwork is assumed to be grounded by shielding on
IN SERIES B reverse of scratch-plate which is assumed grounded via the potentiometers

Model No:-
5B5-01 SSS Parallel Series Scheme B 1V/1T
Scheme No B006 : Last Updated Jul 2018
© Free-Way 2018

REVERSE VIEW OF PICKUPS, SWITCH AND POTENTIOMETERS.

HUMBUCKER COLOUR KEY

FREE-WAY
Inr/Coil Otr/Coil Inr/Coil Start wire
5B5-01
Hot Hot Inr/Coil Finish wire
Grd Grd
Otr/Coil Finish wire
Otr/Coil Start wire
NG NH OP GD B A MH BG BT BH Shield wire

GROUND WIRES TO CAVITY


NECK MIDDLE BRIDGE SHIELD & SPRING CLAW

FRONT VIEW OF PICKUPS AND SWITCH FRONT VIEW OF PICKUPS AND SWITCH
V

10 5 RING

TIP
IN SERIES N

9 4

NG

O H
N
P
No
M + N

D
IN PARALLEL te
:

G
B
te
rm
8 3 ina

M A
ls

BG H
A,
B
&

BT
BG
IN SERIES M ar

BH
e
no
2 tu
7 se T
d.

IN PARALLEL B + M

6 1 Refer to Free-Way Blade Installation Instructions


Note: ensure all pickups are of compatible phase/polarity
Switch metalwork is assumed to be grounded by shielding on
Humbucker B reverse of scratch-plate which is assumed grounded via the potentiometers

Model No:-
5B5-01 HSS Parallel Series Scheme 1V/1T

You might also like