Schematic Electric GS DC

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

F

E
B

D
C
RD

ECN
RD RD WH

11036S
RD RD RD RD
+ - + -

4-6V
U4

B5

ONLY
7A
1

(OPTIONAL)

GS4047
+ + - + - +

-
- -

BATTERY
CB2
-NOTE-

4-12V

1
P1

E
1

CIRCUIT

DC/AC INVERTER
RD

STOP

BREAKER
- - + +

REV
2

BATTERY
BK RD
POSITION WITH
IN THE STOWED

EMERGENCY
THE POWER OFF
MACHINE SHOWN

RD

-
RD

+
BK
RD
RD

U3
1

F6
1/1

BATTERY
CHARGER
275A FUSE
RD
RD

BL

1/1
BK RD
WH/BK

BK
WH

REVISION DESCRIPTION
-
+

BK
+

2
2

K1

C1

BN
BK
BK
RD
-
GCON

WH
N.O.H.C
KS1

3
2

Contactor
PCON 1

-
+
KEY SWITCH

1/1
Motor Controller
Power Cut-off Option

CHARGER IS PLUGGED IN (OPTION)


BN

TO MOTOR CONTROLLER WHEN THE


WH

BLACK AND WHITE WIRES CUT POWER


BK

WH

1/1
BK
C12 C12 RD C80

MOTOR
CONTROLLER
MANIFOLD V- 8/8 8/8 BN BN RD 1/1 1/1
C85
GS 4047 USES PROPORTIONAL VALVE

BN 1/1 RD
BN

U2

A2 3
B+ M
GN/WH 1/1 1/1 GN/WH BK

B- 1
3A

GN/WH
D1

C74 C75
A1
D1

3
3

OPTION
M5

MC THROTTLE
MOTOR

WITH MOTOR
CONTROLLER
CUT-OFF POWER
NOT CONNECTED

3A
D2

REVISE TO E3,ADD 4047,ADD LARGE SLAB, ADD TEMP CUT-OUT MODULE OPTION
C6 J2 J1 C4
GN 11/12 11/12 1/12 1/12 RD ECM LOGIC
DRIVERV+V+

GN/WH
PLATFORM 1/1 1/1 MC ENABLE GN/WH 8/12 8/12 2/12 2/12 RD PCON V+ OUT
C12 C12 UP C73 C72 3/12 3/12 WH ESTOP
MANIFOLD V- 4/8 4/8 2/2 1/2 PLAT FORM UP COIL OR 1/12 1/12 4/12 4/12 GN DATA LINK+

2
5/12 OR DATA LINK-

4
5/12
4

C17
6/12 6/12 BN PCON V- OUT

Y8
7/12 7/12 BN ECM V-
DOWN PLATFORM
8/12 BK PLATFORM MODE
5/6
4/6
3/6

6/6
2/6
1/6

MANIFOLD V- C18 C18 PLATFORM DOWN COIL 8/12


C41

1
C63
1/8 1/8 BN 2/2 2/2 1/1 1/1 OR/BK 2/12 2/12 9/12 9/12 WH GROUND MODE
10W
R30

200 OHM

1/2 1/2

2
C18
1/6

5/6
3/6

C18
4/6

6/6
2/6

Y7
10/12 10/12 WH/BK E STOP
C41

DOWN PLATFORM 12/12 12/12 RD ECM DRIVER V+

BK
WH

C71 C70 GRAY


1/1 1/1
1/1

2
Y9
GS3246 ONLY
U1
/2.B1

/2.C1
/2.C1
/2.C1
/2.C1

1/1

5
5

J3 C5 C8 C8
C83

STEER LEFT
1/12 1/12 GROUND BN 6/8 6/8

BY
C16 C47 ALARM

TF
MANIFOLD V- 3/8 3/8 BN 2/2 1/2 STEER LEFT COIL BL/BK 3/12 3/12 2/12 2/12 BL ALARM OUT 1/1 1/1 GROUND BN 1/8 1/8
-

BN 2/8 2/8
+

C52
H5

Y4

6/12 6/12 BN GROUND GROUND BN 7/8 7/8


STEER RIGHT
4/12 4/12 WH AUTO HORN OUT1/1 1/1 GROUND BN 5/8 5/8
C15

DATE
-

6/8 6/8 BN 2/2 1/2 BL 4/12 BN 4/8 4/8


+

MANIFOLD V- STEER RIGHT COIL 4/12 C45 C53


H2

11/8/11
2

AUTO STYLE HORN BN 3/8 3/8


(OPTION)
1Y3

3/12 3/12 RD SENSOR V+

MANIFOLD V- C22 C22 C9 C9 C9 C9


ONLY
LARGE SLAB

2/8 2/8 BN 2/2 1/2 PARALLEL COIL RD/WH 5/12 5/12 5/12 5/12 OR/RD
4/4 4/4 BK WH3/4 3/4
B
ELECTRONIC CONTROL MODULE

SIZE

6
6

SPK
2

POTHOLE LIMIT SW
22
21

MODEL
22
21

1Y1
LS8

11/12 11/12
POTHOLE LIM SW
N.C.H.O.

LIFT PRESSURE SELECTOR BN 7/12 7/12 C9 C9 C9


OR/RD

GS 30/32/46
DRIVE FORWARD 2/4 2/4 BK WH 1/4 1/4 C7 C7
CREATED/DRAWN BY

RD 4/12 4/12
22

21

SCALE

MANIFOLD V-
22

21

C14
LS7

7/8 7/8 BN 2/2 1/2 DRIVE FORWARD COIL WH 6/12 6/12


NOT TO SCALE

POTHOLE LIM SW
11/12
1

2
N.C.H.O.

RD 11/12
DATE

C84 C84 SENSOR V+


Y2

WEIGHT
Y6

BN 2/2 1/2 OR/RD 9/12 9/12 C10 C10 C10


C10
REFERENCE
8/29/2011
1

DRIVE REVERSE 7/12 7/12 OR 2/2 2/2 WH 1/2 1/2


8/12
ONLY

RD/BK
14
13

MANIFOLD V- 8/12
14
13

LIFT PRESSURE SELECTOR


GS4047
LS6

5/8 5/8 2/2 1/2 WH/BK 10/12 10/12 9/12 9/12 BK LEVEL SENSOR
DOWN LIMIT SW
7
7

N.O.H.C.

DRIVE REVERSE COIL 12/12 10/12 BK


1

12/12 10/12
2

C13
Y5

12/12 12/12 BK GROUND


TITLE

GROUND
SHEET

BLACK GREEN
MATERIAL

GROUND
1 OF

RD 2/12 2/12
2

RD 7/12 7/12
C21 C21 C64 C62
-
+

1/4 1/4 BK LS GND 1/1


1/1 RD 6/12 6/12
2/4 2/4 BK GROUND
3/4 3/4 BK GROUND
FB(OPTION)
BN

4/4 4/4 C66 C65


ES0534
-
+

1/1 1/1 RD 8/12 8/12


8
8

DRAWING NUMBER

SENSOR V+ RD 1/12 1/12


BN
RD/BK
BK
WH

B/3
A/3
C/3
C11
BK/RD
WH BK

B/3
C/3
A/3

SCHEMATIC, ELEC, ANSI, GS

GT
C11
(OPTION)
BK/RD

GROUP
BK
RD
WH
CUT-OUT MODULE
LOW TEMPERATURE

BN

9
9

E
REVISION
S7

V-
WITH LOW

V+
SIG

TEREX PROPRIETARY, CONFIDENTIAL, AND/OR TRADE SECRET


LEVEL
TEMPERATURE

Do Not Use, Reproduce, Publsih, or Disclose to Others Without Express Written Authorization By TEREX CORPORATION, USA
SENSOR
CUT-OUT OPTION
NOT CONNECTED

F
A

E
B

D
C
1 2 3 4 5 6 7 8 9

AC INPUT
POWER TO PLATFORM
(110V-240V AC) QD30 QD4A
AC
GN 1 1 GN 1 1 GN/YL OUTLET
A BK 2 2 BK 2 2 BK A
WH 3 3 WH 3 3 BL

GND
EN4 Ground
AC STUD
OUTLET BOX

B B

J3 J3 J5 J5
C2 C2 C3 C3 1/6 1/6 1/8 1/8
1/6 1/6 1/6 1/6 2/6 2/8 +
PCON V+ OUT RD RD PCON V+ OUT PCON V+ OUT RD 2/6 2/8 RD 1 H1
/1.A5
ESTOP WH 2/6 2/6 WH ESTOP 2/6 2/6 ESTOP WH 3/6 3/6 3/8 3/8 BK ALARM
/1.A5 2
DATA LINK+ BL 3/6 3/6 BL DATA LINK+ 3/6 3/6 DATA LINK+ BL 4/6 4/6 4/8 4/8 E-STOP+ WH -
/1.A5
DATA LINK- OR 4/6 4/6 OR DATA LINK- 4/6 4/6 DATA LINK- OR 5/6 5/6 5/8 5/8 E-STOP- WH
/1.A5
PCON V- OUT BN 5/6 5/6 BN PCON V- OUT 5/6 5/6 PCON V- OUT BN 6/6 6/6 6/8 6/8 1
/1.A5
6/6 6/6 6/6 6/6 7/8 7/8
P2
8/8 8/8 EMERGENCY
C 2 C
STOP
PLATFORM CONTROLS
PRINTED CIRCUIT BOARD
J4 J4 JC9
1/12 1/12 JOYSTICK AXIS 1 YL 1
2/12 2/12
3/12 3/12 STEER SWITCH COM BK 2
4/12 4/12 DRIVE ENABLE COM YL 3
5/12 5/12 DRIVE ENABLE WH 4
6/12 6/12 STEER LEFT BL 5
7/12 7/12 STEER RIGHT GR 6
8/12 8/12 JOYSTICK 5VDC RD 7
D D
9/12 9/12
10/12 10/12 JOYSTICK GND BK 8
11/12 11/12
12/12 12/12 CHASSIS GND BK 9

PLATFORM
CONTROLLER

E E
-NOTE-
MACHINE SHOWN
IN THE STOWED
POSITION WITH
THE POWER OFF

TEREX PROPRIETARY, CONFIDENTIAL, AND/OR TRADE SECRET


Do Not Use, Reproduce, Publsih, or Disclose to Others Without Express Written Authorization By TEREX CORPORATION, USA
TITLE
F SCHEMATIC, ELEC, ANSI, GS F

SIZE SCALE WEIGHT MATERIAL


B NOT TO SCALE
CREATED/DRAWN BY DATE SHEET DRAWING NUMBER
GROUP REVISION
SPK 8/29/2011 2 OF 2
ECN REV REVISION DESCRIPTION BY DATE MODEL REFERENCE
11036S E REVISE TO E3,ADD 4047,ADD LARGE SLAB TF 11/8/11 GS 30/32/46 ES0534 GT E
1 2 3 4 5 6 7 8 9

You might also like