MOV Instrument Datasheet

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Doc. No.

:
Toyo Engineering Construction Sdn. Bhd.
Level, 25, Menara Haw Par, COCO-P3-EXE-TOYO-PCE-
Jalan Sultan Ismail, 000-INC-MRE-0020
50250 Kuala Lumpur, Malaysia.
Revision : 0
PROVISION OF ENGINEERING, PROCUREMENT,
CONSTRUCTION, AND COMMISSIONING (EPCC) FOR
Page 1 of 11
NEW ETHYLENE EXPORT FACILITY FOR PROJECT COCONUT
FOR PETRONAS CHEMICALS OLEFINS SDN BHD

ATTACHMENT-6

INSTRUMENT DATASHEET FOR CUSTODY TRANSFER


METERING SYSTEM

Open
TOYO ENGINEERING AND CONSTRUCTION
SDN. BHD. (152170-T) Page: 3 of 11
Doc. No. COCO-P3-EXE-TOYO-PCE-000-INC-MRE-0020
Client : PETRONAS CHEMICALS OLEFINS SDN. BHD.
: PETRONAS CHEMICALS ETHYLENE SDN. BHD.
Plant/Unit : PCE
Location : KERTEH, MALAYSIA
Work No. : JB-0393
Req. No. : AYKC511-20

CUSTODY TRANSFER METERING SYSTEMS - INDEX

No TAG NO DESCRIPTION REMARKS Rev


1 TF-0-PG-351 PRESSURE GAUGE
TF-0-PG-352A PRESSURE GAUGE
TF-0-PG-353A PRESSURE GAUGE
TF-0-PG-354A PRESSURE GAUGE
TF-0-PG-352B PRESSURE GAUGE
TF-0-PG-353B PRESSURE GAUGE
TF-0-PG-354B PRESSURE GAUGE
2 TF-0-MOV-351A MOTOR OPERATED VALVE
TF-0-MOV-352A MOTOR OPERATED VALVE
TF-0-MOV-353A MOTOR OPERATED VALVE
TF-0-MOV-354A MOTOR OPERATED VALVE
TF-0-MOV-351B MOTOR OPERATED VALVE
TF-0-MOV-352B MOTOR OPERATED VALVE
TF-0-MOV-353B MOTOR OPERATED VALVE
TF-0-MOV-354B MOTOR OPERATED VALVE
TF-0-MOV-355 MOTOR OPERATED VALVE
TF-0-MOV-356 MOTOR OPERATED VALVE
3 TF-0-FT-351A CORIOLIS FLOW METER
TF-0-FT-351B CORIOLIS FLOW METER
4 TF-0-PT-351A PRESSURE TRANSMITTER
TF-0-PT-351B PRESSURE TRANSMITTER
5 TF-0-TT-351A TEMPERATURE TRANSMITTER
TF-0-TT-351B TEMPERATURE TRANSMITTER
6 TF-0-TW-353A TEST WELL
TF-0-TW-353B TEST WELL
7 TF-0-TG-354 TEMPERATURE GAUGE
TF-0-TG-352A TEMPERATURE GAUGE
TF-0-TG-352B TEMPERATURE GAUGE
TOYO ENGINEERING AND CONSTRUCTION
SDN. BHD. (152170-T) Page: 4 of 11
Doc. No. COCO-P3-EXE-TOYO-PCE-000-INC-MRE-0020
Client : PETRONAS CHEMICALS OLEFINS SDN. BHD.
: PETRONAS CHEMICALS ETHYLENE SDN. BHD.
Plant/Unit : PCE
Location : KERTEH, MALAYSIA
Work No. : JB-0393
Req. No. : AYKC511-20

No Rev
GENERAL NOTES
1 Custody Transfer Metering System shall be fully compliance with COCO-P3-EXE-TOYO-PCE-000-INC-SPC-0008 Specification for Ethylene Custody Trans-
fer Metering System and COCO-P3-EXE-TOYO-PCE-000-INC-SPC-0001 Specification for Field Instrument. Body/Rating/Flanges type shall be relevant with the Specification for Piping Mater
The materials rating shall be as per design pressure / temperature and suitable as per process condition.

PRESSURE GAUGES
2 All Pressure Gauges shall have dual scale (barG And kPaG) , main indication shall be in barG, secondary indication shall be in kPaG.

3 Gauge Saver shall protect the gauge up to the design pressure (if applicable). Gauge Saver shall be 316 SS. 1/2" NPTM inlet x 1/2" NPTF outlet and shall
be in accordance with ASME B-40.6 - 2001.

MOTOR OPERATED VALVES (MOV)


4 Motor supply voltage shall be 415 VAC 3-Phase 50 Hz distributed by Vendor from the Skid Power Distribution Panel.

5 Motor shall have integral motor starter, local open/close/stop switch, protection for instantaneous reversal and thermal overload, Class-F insulation with
Class-B temperature rise padlockable local/off/remote selector switch, padlockable handwheel and adjustable torque limit switch and embedded
thermostat to prevent motor burn-out.

6 Vendor shall provide three separate cable entries for the motor; one for power and two for control. All cable entries shall be ISO M20x1.5. Vendor shall
provide adapter if required. All entries shall be plugged using certified plugs. The following signals are required to be sent to/from Metering System:
- Inhibit open
- Close indication
- Open command
- Local / Remote control indication
- Close command
- Travel indication
- Open indication
- Fault indication

7 All Valve / Actuator assemblies shall be provided with Local Illuminated Position Indication Device (LCD Type preferred) for valve opened, valve closed
and valve travelling, as a minimum.

TEMPERATURE GAUGES
8 Thermometer and Thermowell shall be supplied as complete units. Vendor shall match standard length to suit Thermowell.

9 Temperature Gauge assembly shall be as per Standard Drawing D14.92.010-D. Stem length shall be provided accordingly.

10 Zero adjustment and over-range protection shall be as per manufacturer standard.

11 Thermowell construction shall comply to PTS Standard Drawing D12.92.339-A & D12.92.340-A
TOYO ENGINEERING AND CONSTRUCTION
SDN. BHD. (152170-T) Page: 6 of 11
Doc. No. COCO-P3-EXE-TOYO-PCE-000-INC-MRE-0020
Client : PETRONAS CHEMICALS OLEFINS SDN. BHD.
: PETRONAS CHEMICALS ETHYLENE SDN. BHD.
Plant/Unit : PCE
Location : KERTEH, MALAYSIA
Work No. : JB-0393 Item No. See Index Sheet
Service : CTMS SKID-MOV FOR INLET LINE-1
P&ID No. : COCO-P3-EXE-TOYO-PCE-000-PRO-PID-0003
No DATASHEET FOR MOTOR OPERATED VALVE Rev
1 Process Fluid / State Ethylene Liquid
Maximum Normal Minimum Units
2 Inlet Pressure - 7 - barG
SERVICE o
3 Temperature - -98 - C
CONDITIONS
4 Design Pressure 46 - - barG
o
5 Design Temperature -114 - - C
6 Max Differential Press. (Max Shut-off) 46 - - bar
7 Class / NACE / PWHT 3S119 No No
8 LINE Size / Schedule / Line ID DN100 SCH 10S 108.20 mm
9 Line Number / Insulation 100-P3402-3S119(ET)CC Cool Conservation Insulation
10 Type Full Bore, Floating Ball Valve
11 Code & Standard ASME B16.34
12 Size DN100 (by Vendor)
13 Rating 300#
14 Bonnet / Cap Extended for Cryogenic (by Vendor)
15 TYPE Yoke / Stem by Vendor
16 Connection Flanged
17 F to F/E to Dim. by Vendor
18 Flange Dimension ASME B16.5
19 Flange Size / Rating / Facing DN100 (by Vendor) 300# ASME B16.5 RF
20 Flange Face Finish ASME B16.5 AARH
21 Body / Bonnet Material A351GR.CF8
22 Seats (Disc / Body) ASTM A182 Grade F 316 + Stellite HF
23 Trim Stem / Shaft / Hinge Pin ASTM A182 Grade F 316 + Stellite HF
24 MATERIAL Disc Plate ASTM A182 Grade F 316 + Stellite HF
25 Gasket Material by Vendor
26 G. Packing by Vendor
27 Bonnet Bolt / Nut A320GR.B8(CL.2) / A194GR.8
28 OPERATION Full Stroke Time (Open / Close) 15 seconds (Max) 15 seconds (Max)
29 Seat Leakage Class TSO, IEC 60534-4 Class VI
OTHER
30
31 Enclosure Class Area Classf. IP65 Zone 2, IIB, T3
32 Ex Approved Ex Certification Ex'd' IECEx
33 Ext. Power Supply KW Rating 415 VAC 3-Phase 50 Hz by Vendor
34 Space Heater Insulation Class - Class-F
35 Signal Cable Conn. Power Cable M20x1.5 ISO
36 Position Indicator (Opening,Open/Close) Yes
37 Local / Remote Control Local-Off-Remote Padlockable
ACTUATOR
38 Command Signal from Flow Com. Yes
39 Status Signal to Flow Com. -
40 Communication Protocol -
41 Thermostat (Open/Close Torque Swicth) Yes
42 Local / Remote Indicator in Flow Com. Yes
43 Limit Switch (Open / Close / Other) Open-Close, Proximity SPDT (1A rated at 24VDC)
44 Command (Open / Close / Other) Open-Close-Stop
45 Manual Handwheel Side Mounted Handwheel
ACCESSORIES
46
47 Manufacturer (Valve & Actuator) BY VENDOR
PURCHASER
48 Model (Valve & Actuator) BY VENDOR
NOTES:
1. Actuator shall be sized at least 1.25 times of the valve required torque at full flange full rated differential pressure
2.