8 Juni 2011
GRID
Agenda
AREVA ALSTOM
− Nuclear fuel front end − Marine
processing
− Transport
− Nuclear reactors
− Power
− Nuclear fuel re-processing
− T&D − GRID
HV
HV switchgear
switchgear Power
Power transformers
transformers MV
MV products
products
Energy
Energy Automation
Automation & & Information
Information
(( EAI
EAI ))
Services
Services
EAI : Provide control systems for all stages of power system operation
Market
Market
Mgt
HV / MV Instrument
Transformers Sensors
switchgear Transformers
Transmission network
VHV customer
Sub-
Sub-transmission network
HV customer
Primary
distribution
system Generation
&
Distribution transmission
applications applications
MV customer
or MV / LV transformer ( DMP ) ( EMP )
Presentation title - 15/03/2011 - P 8
Power System Operation
SCADA PLC
Communication network
Reports
Operators PC - Windows
NMS Products Portfolio
e-terramarket
e-terrasettlements Market
e-terracommit Management
e-terraplatform Systems
e-terragridcom
Telecom
NMS 5000
SDH/ PDH e-DXC5000
PDH DXC5000 Telecommunication Network
SDH MSE5000
LMU 5000
PLC 5000 / T390
TP DIP 5000 / TPI
Network Substation
and Network
Substation
MiCOM C264
e-terrartu600
Control Center
Network
Generation
SCADA
Front End
Dedicated telecom
e-terra Control
SCADA / Front End
Internet
e-terracontrol
3 Front End
e-terracontrol
2 Substation Data Server
IED IED
Small Operations
Center
DCS Modem
Equipment Substation 4 SCADA
5 DMS
Remote Terminal Unit
Substation
Modem
Modem
Remote Terminal Unit
e-terracontrol
Presentation title - 15/03/2011 - P 16
EMP / DMP
Product Overview
• EMP = Full EMS solution
• DMP = Full DMS solution
» Common core and basic functionality
Backbone network
High Capacity
Microwave
Optical Fibre
(OPGW, ADSS, Wrapped)
Microwave Radio
High Capacity
Optical Fibre
SDH technology
Low Capacity
Microwave
Low Capacity
Optical Fibre
Access network
UHF/VHF Optical Fibre
Radio
PDH Microwave
TDM/TDMA
Radio
Power Line Carrier (PLC)
UHF/VHF Radio
AF
Cable
PLC Trunked/Cellular Radio
AF Cable
Data
Acquisition
GENERATION
DISPATCHER
SCADA TRAINING
SIMULATOR
Supervisory
Control
NETWORK
SCADA
• Process analogs,
RT data RT data
status,
SCADA limits accumulators
Telemetered limits
• Value replacement
• Calculations
• Limit checking
• Historical data record.
• Intersite data Gen.
Repl. val. • Topology processing set-points
• Tagging
• Controls
NETWORK • Load shedding
GENERATION
OLNETSEQ
AGC
Topology processing
Economic dispatch
State estimation
Reserve monitor
Monitored element processing Gen. sched. / status / part.fact. / costs AGC performance monitor
Bus load model update
Interchange transactions Historic loss model update
Bus load forecasting
Load forecast Production costing
Loss sensitivities
Transaction scheduling
Short-circuit analysis
Contingency analysis Loss sensitivities Load forecasting
Security enhancement
Generation limits Operations planning
Voltage / VAr dispatch
Study generation
Power flow
Transaction evaluation
Optimal power flow
Outage scheduler
Presentation title - 15/03/2011 - P 27
EMP
Functional Scope (1)
SCADA subsystem
− Data acquisition:
• non proprietary environment (PC + serial boards)
• multiple RTU protocols: IEC101&104, DNP3, proprietary protocols
• Core data processing: POINTs, ANALOGs, COUNTs, calculated values,
quality flags, limits, AOR, SOE, ..
• SCADA event logs, exception lists, alarms
− Controls (1,2,3 steps, DO, SBO, group, sequence , interlock,
tagging)
− SCADA related functions :
• Topology, Loadshed, Mapboard
• Disturbance storage & analysis ( HDR )
− Can accommodate large systems ( 300’000 points )
− Interfaces with external systems: ISD, ICCP, ELCOM
(“e-terraComm” / OAG)
NETWORK subsystem:
− Topology
− State Estimation
− Contingency Analysis
− Short Circuit
− Security Enhancement
− Optimal Power Flow
− Volt VAr Dispatch
− Power flow
− Real Time and Study modes
Data
Acquisition
GENERATION
DISPATCHER
SCADA TRAINING
SIMULATOR
Supervisory
Control
NETWORK
Operator Trainee
Presentation title - 15/03/2011 - P 32
EMP / DMP Example of hardware architecture
Other
CCs
Router
Router
Development
Historical computer Inter-center Trouble call OPS
Data servers DTS server WEB FG & work order
data server access server server
server server
Time
Time
Router
Router device
device
Wall board
Operator stations Hard copy or
Communication devices video projection
front-ends GPS time
Office LAN
Presentation title - 15/03/2011 - P 33
EMP / DMP Advantages
Data
Acquisition
OPERATION
SUPPORT
DISPATCHER
GRID
SCADA TRAINING
SIMULATOR
Supervisory
Control DISTRIBUTION
NETWORK
ANALYSIS
AND
OPTIMIZATION
DMP
Functional Scope overview
• DMP = Same SCADA + DTS as EMP
+ Distribution oriented applications
• SCADA related functions
• Radial topology
• Temporary modifications
• Volt VAr Control
• Load shedding
• Sequence switching
• NETWORK analysis and optimization
• Real-Time & Study Power flow with radial constraints
• Radial Network Reconfiguration
• Operation Support
• Trouble Call & Outage Management
• Work Orders Management
• Automatic generation of schematic one-line displays
Presentation title - 15/03/2011 - P 37
DMP
SCADA related functions
• Radial topology
• Downstream of specified links
• Feeder identification (recognize upstream / downstream
relationships)
• Feeder coloring
• Circuit tracing
• Mesh detection
• Temporary Modification Management
• Line CUT (special mark on display)
• Line grounding (special mark on display)
• Switch bypass (considered closed whatever its actual state)
• Switch withdrawal (does not affect topology anymore)
Customers
CIS
Call Callback
Billing info
LV connectivity
Call handling
Medium Voltage
Presentation title - 15/03/2011 - P 43 Network
DMP
Trouble Call & Outage Management
• Electronic Management of Customer Calls & Outages
• Improve Quality of Service and Customer Satisfaction
• Detect and solve network problems as quickly as possible
• Automatically group related calls according to real-time topology
• Consolidate outage information from all sources, including DMS
SCADA
• Manage scheduled outages
• Provide general access to current outage situation ( Web-enabled )
• Track actual outage duration and repair time
• Statistics and reporting, Indexes on quality of service
WORK
WORKORDERS
ORDERS
server
server
Controls Status
MV network
Presentation title - 15/03/2011 - P 45
DMP
Work Orders Management
• Electronic Management of Maintenance, Construction and Emergency
Works
• Enforce Safety Rules
• Standardize and accelerate the job life cycle
• Optimize allocation of resources
• Simulate execution of the tasks, analyze network reconfiguration
• Coordinate automatically with the DMS
(including FDIR & OSW)
• Allow all people involved to monitor progress of work. Web-enabled
• Track actual work time, duration, assignments
• Statistics and reporting
Trouble Call
Work Order
clients
DTS & clients
PBX, CTI & Trouble Call servers Work Orders
development
Presentation title - 15/03/2011 - P 47
server server
DMP Advantages
(according to a customer)
• Proven combination of DMS and VRS
(Voice Response System)
• Automatic generation of operation schematic one-lines
• Good interface with GIS ( Geographic Information System)
• Several key applications for operators, such as
− FDIR (Fault Restoration)
− TCS (Trouble Call System / Outage Management)
− WOM (Work Orders management)
• WEB enabled
• Easy to work with
• Proven record of on-time / fast track deliveries
19- (8) DI (4)DOH (4) (4) (4) (4) (8) (3) (4) GPRS 85 – 265
60 24- +1 7V Pulse VAC/DC
VDC 48V select +/- 1 +/-1mA 1A CT VT Count.A 1A CT + 1A CT +
+FCD ccu.
mA (3) VT (4) VT
Aerial 11KV
Pole mounted Switch & RTU
GPRS
Underground 11KV
RMU (4Ways Switch & CB)
Optical fiber (ring)
LINE TRAP
H.V.
TRANSPORT
NETWORK
COUPLING CAPACITOR
Line Matching
unit
Protection
MICOM
Teleprotection
TA 314 Alspa PLC 1790
Power Line Carrier
LINE TRAP
H.V.
TRANSPORT
NETWORK
Management
Control
command
system
or
SCADA
SPV 5000
Optical link
OCM 5000
Digital Teleprotection
Electrical link DIP 5000
MUX
Cubicle
Management
Services system
Control
command SPV 5000
or
SCADA
TA 314 Available
• Up to 4 commands
Analogue teleprotection • 4 wire analogue interface
•Up to 8 commands
DIP5000 Available
•Optical (1310,1550) interface
Universal teleprotection •V11, G703 electrical interface
•Analogue interface (March 2004)
OCM5000 Available
• 1 V11 or V24 interface
Optical <-> electrical • 1 optical interface
Control Center
Control
SCADA EMS DMS MMS UPS
Rooms
Telecommunications Network
•Design •Fiber Optic
•Engineering •Digital Microwaves
•Pilot Cable
•Hardware •Power Line Carrier
•Software •Teleprotections
•Telephone Network
•Installation •Telecoms Management System
•Commissioning
•Training
•Maintenance
•Product update Substations, Power Stations
RTUs Process
48V DC
DCS Interface
Presentation title - 15/03/2011 - P 60
Agenda
a9
Remote
Diagnose.
a7
Remote
Setup
a8
Remote
Maint.
Telecommunication System
Routing Data Path of FO & Radio Communication
Monitoring of Telecommunication Equipment
5
SCADA AREVA
1 E-terracontrol
IEC 104 Objectives:
» extendable to DMS system
» open system w/ various choices of protocol comm.
» complete w/ historical system
WAN » continues real time data
» larger data sizing
» single system for overall distribution network
2
4
3 Modbus RTU
/ DNP 3.0
RTU MiCOM C264 + Radio Modem
Objectives:
» Safety operation
» Flexible to follow Pola SCADA design
Hardwired I/O
» open system for common use IED comm.
» continues real time data
New Architecture Plan
Presentation title - 15/03/2011 - P 80
BEKASI POWER
Control Centre Architecture
5
SCADA AREVA
1 E-terracontrol
IEC 104 Objectives:
» extendable to DMS system
» open system w/ various choices of protocol comm.
» complete w/ historical system
WAN » continues real time data
» larger data sizing
» single system for overall distribution network
2
6
3 Automation
Network
RTU MiCOM C264 + Radio Modem
Objectives:
» Safety operation
» Flexible to follow Pola SCADA design
Hardwired I/O
» open system for common use IED comm.
» continues real time data
New Architecture Plan
Presentation title - 15/03/2011 - P 81
THANK YOU