Air Louvers
Model: CI - Air L - H
CI - Air L - H
CI - Air L - H
Features:
Designed for use as air intakes or air exhaust louvers for commercial or industrial air conditioning systems.
Combines fine architectural design with good performance meets most requirements.
Louvers are completely weather proof and rain proof blade lips.
Can be provided with bird or insect screens, White and anodized aluminum are the standard color,
other colors are available upon request.
16
0.37 0.43 0.50 0.57 0.64 0.77 0.98 1.18 1.38 1.59 1.79 1.99 2.40
(41)
20
0.52 0.61 0.71 0.80 0.90 1.09 1.38 1.66 1.95 2.24 2.52 2.81 3.38
(51)
24
0.67 0.79 0.91 1.04 1.16 1.41 1.78 2.15 2.52 2.89 3.26 3.63 4.37
(61)
28
0.82 0.79 1.12 1.27 1.42 1.72 2.18 2.63 3.08 3.54 3.99 4.44 5.35
(71)
32
0.97 1.04 1.32 1.505 1.68 2.04 2.58 3.11 3.65 4.18 4.72 5.26 6.33
(81)
36
1.12 1.32 1.53 1.74 1.94 2.36 2.98 3.60 4.22 4.84 5.46 6.08 7.32
(91)
40
1.27 1.50 1.73 1.97 2.20 2.67 3.38 4.08 4.78 5.49 6.19 6.86 8.30
(102)
44
1.41 1.68 1.94 2.20 2.46 2.98 3.78 4.55 5.34 6.12 6.91 7.69 9.26
(112)
48
1.57 1.86 2.15 2.44 2.736 3.31 4.18 5.05 5.92 6.79 7.66 8.53 10.27
(122)
52(
1.72 2.03 2.35 2.67 2.99 3.62 4.58 5.53 6.48 7.44 8.39 9.34 11.25
(132)
56
1.87 2.21 2.56 2.90 2.25 3.94 4.98 6.01 7.05 8.08 9.12 10.16 12.23
(142)
60
2.02 2.39 2.67 3.14 3.51 4.26 5.38 6.50 7.62 8.74 9.86 10.98 13.22
(152)
Note: 1.0
For sizes not shown, the approximate free
area in square feet can be calculated by
using the formula below: 0.5
0.3
W= Width on feet
H= Height on feet 0.2
Ps)
Ps)
T (+
(Sq. Ft.) X (fpm) 0.1
E (-
US
AK
HA
INT
EX
Pressure Loss Inches w. g.
0.05
0.04
0.03
0.02
0.01
0.005
0.004
0.003
0.002
0.001
100 200 300 400 600 1000 2000 3000 4000 5000
CI - Air GS-H
CI - Air GS-H
Features:
A horizontal operatable shutter which operates to equalize the pressure across it.
The frame and blades are constructed of extruded aluminum anodized as standard painted, powder
coated are available on request.
The frame has a typical wall thickness of 1/16” and separated from the movable blades by an extruded
rigid PVC track which is riveted to and becomes an integral part of the frame. A1/8” thick, 3/8” wide foam
tape is installed on the blades where they overlap to insure a good seal and to reduce noise.
Each shutter is carefully designed to equalize the pressure in such areas as a compressor of fan room with
the outside.
The blades are designed and positioned in such a way that if the pressure in the room increase the blades
automatically lift and open relieving the pressure in the room.
When the room pressure is normalized the blades drop to the closed position by gravity.
These devices are also employed at the end of exhaust ducts where they would open when the exhaust
fan was turned on and would close when the fan was turned off.
Listed Height
(Inches) 12 14 16 18 20 24 30 36 42 48 54 60 72
12 0.81 0.96 1.10 1.25 1.40 1.64 2.08 2.47 2.91 3.30 3.74 4.13 4.96
16 1.08 1.27 1.47 2.66 1.86 2.18 2.77 3.29 3.87 4.44 5.02 5.49 6.60
20 1.36 1.60 1.85 2.09 2.33 2.75 3.48 4.13 4.87 5.52 6.25 6.91 8.30
24 1.62 1.92 2.21 2.50 2.79 3.29 4.16 4.95 5.82 6.61 7.48 8.17 9.93
Listed Height
28 1.89 2.23 2.57 2.91 3.25 3.83 4.85 5.76 6.78 7.69 8.71 9.63 11.56
32 2.16 2.55 2.93 3.32 3.71 4.37 5.53 6.57 7.74 8.78 9.94 10.99 13.19
36 2.44 2.87 3.31 3.75 4.19 4.93 6.24 7.42 8.73 9.91 11.22 12.40 14.89
40 2.70 3.19 3.68 4.16 4.65 5.47 6.93 8.23 9.69 11.00 12.45 13.76 16.52
44 2.97 3.50 4.04 4.57 5.11 6.01 7.61 9.05 10.65 12.08 13.68 15.12 18.16
48 3.25 3.83 4.42 5.00 5.59 6.57 8.32 9.89 11.64 13.21 14.97 16.54 19.86
52 3.52 4.15 4.78 5.41 6.04 7.11 9.01 10.71 12.60 14.30 16.20 17.89 21.49
56 3.78 4.46 5.14 5.82 6.50 7.65 9.69 11.52 13.56 15.39 17.43 19.25 23.12
60 4.06 4.79 5.52 6.25 6.98 8.21 10.40 12.36 14.55 16.52 18.71 20.67 24.82
CI - Air SL-H
Features:
The sand trap louver is used to lower the dust loading of conventional filtration as it is designed to separate
large size sand particles at low to medium speeds.
It is also fitted with a bird screen mesh made of galvanized steel to protect against the unwanted objects.
The sand trap louver is a self emptying system, it has a set of holes at the bottom face of the casing to
discharge separated sand particles.
Performance:
Ordering System:
General:
CIC Sand Louver CI - Air DL- H are architectural air inlets. They are
widely used for building exteriors and are suitable for different
HVAC and industrial applications to prevent sand entry.
CI - Air DL- H louvers have 2 inch deep horizontal fixed blades designed carefully for low pressure drop and
to prevent entry of sand.
The frame is 1.25” wide (flat or curved) flanged type and is mechanically joined to give a rugged
construction to the louver.
These louvers are available as optional with galvanized bird screen, aluminum type air filter in 1”, 2” and 4”
thickness and volume control damper.
They are manufactured in a wide range of standard sizes however, they can be supplied in non-standard
sizes, depths or architectural shapes to suit customers requirements.
CI - Air DL- H sand louvers are made of heavy extruded aluminium profiles.
They are available in white polyester powder coated finish or any other RAL standard colour upon
customer’s request.
Bird screens are made of galvanized expanded metal sheets.
Width in inch.
Height in inch.
Accessories:
B : Bird screen
D : Volume Control Damper (VCD)
BD : Bird screen & VCD.
I : Insect Screen.
F1 : Aluminium Filter 1” thick.
F2 : Aluminium Filter 2” thick.
F4 : Aluminium Filter 4” thick.
Use the code of CI - Air DL- H to refer to CIC sand louver with flat frame.
Example:
• CI - Air DL- H - 30 - 18 - B:
CIC Sand Louver - size 30” x 18” with bird screen.
• CI - Air DL- H - 24 - 20 BDF1:
CIC Sand Louver - size 24” x 20” with bird screen, volume control damper and 1” thick aluminium filter.
selection procedure:
To select a suitable size of a sand louver (CI - Air DL- H) for a certain application, follow exactly the same
procedure as been explained previously.
Note:
The approximate effective free area in square feet can be calculated by using the following formula:-
Pressure Requirement
Face Velocity (FPM) 200 300 400 500 600 700 800 900 1000 1200 1400 1600
Intake PD° W.G. 0.007 0.016 0.028 0.044 0.063 0.086 0.112 0.141 0.175 0.252 0.338 0.433
Table No. 2 Intake pressure drop in inches of water as a function of face velocity in FPM for CI - Air DL- H.
Table No. 3. Effective free area in ft² factor) for CI - Air DL- H.
General:
CIC penthouse louvers CI - Air PHL - H are considered as typical louver units for both air intake and exhaust
applications.
They are designed and built to become a permanent part of the building.
They maintain their pleasant appearance and effective weather protection as a result of their rugged,
durable, extruded aluminium construction and careful workmanship.
They are usually furnished with either mullion or mitered corners and incorporate the normal CIC fresh air
louver blades CI - Air PHL - H as standard. However, any other type of CIC louver blades can also be used
as optional.
Penthouse Louver (CI - Air PHL - H) Penthouse Louvers (CI - Air PHL - H)
With Mullion Corner With Mitered Corner
Description:
CI - Air PHL - H penthouse louvers have as a standard 2” deep fixed horizontal blades.
The blades are carefully designed to get low pressure drop, maximum free area and to prevent rain-water
penetration.
They are available in 1.25” flanged frame and are built and mounted to an internal framing with mullion
corners.
The integral framing mullion structures are furnished with a standard 1.6” x 1.6” extruded aluminium
profiles.
For the other mitered corners type penthouse louvers, blades are beveled and welded internally at the
end.
The top of the penthouses are covered with flat or pitched roofs of aluminium sheets.
All of the four louver sides are of removable type for easy maintenance purposes, Penthouse louvers can
also be supplied as optional with galvanized bird or insect screens and / or aluminium washable air filters
of 1”, 2”, or 4” thickness.
CI - Air PHL - H penthouse louvers are made of heavy gauge extruded aluminium profiles. They are
available in white polyester powder coated finish or any other RAL standard colour upon customer’s
request.
Structural mullion corners are of strong aluminium profiles while roof tops are of aluminium sheets
as a standard.
However, galvanized roofs are also available upon request.
Bird screens are made of galvanized expanded metal sheets.
Width in inch.
Length in inch.
Height in inch.
Accessories:
B : Bird Screen
I : Insect Screen
F : Aluminium Filter 1” thick.
F2 : Aluminium Filter 2” thick.
F4 : Aluminium Filter 4” thick.
Example:
CI - Air PHL - H - 18 - 18 - 24 - B:
CIC penthouse louver with 18” x 18” basement
size, 24” height and bird screen.
Definitions:
: Is the air stream velocity measured at the face of a louver in FPM
Face velocity
and it corresponds to the effective free area.
Total pressure drop : Is the sum of static pressure and velocity pressure given in inches W.G
CI - Air PHL - H - F2
Example:
Select a penthouse louver for an exhaust requirements of 3300 CFM with a total pressure drop of 0.1” W.G.
1) From the pressure requirement table 2 it shows that an 800 FPM velocity results an exhaust pressure
drop of 0.1” W.G.
2) Determine the effective free area:
CFM
Effective free area Ak =
Vk
3000
= = 4.125 ft2
800
3) From table 3 the 4.125 ft2 effective free area is suitable for the following penthouse louver’s sizes:
• P = 5 ft, H = 28 inch.
Could be suitable for a penthouse basement dimensions of (WxL) - 12” x 18”.
• P = 6 ft, H = 24 inch.
Could be suitable for a penthouse basement dimensions of (WxL) - 12”x24” or 18” x 18”
depending on the duct size.
Note:
The approximate effective free area in square feet can be calculated by using the following formula:-
Pressure Requirement:
Free Velocity (FPM) 200 300 400 500 600 700 800 900 1000 1200 1400 1600
Intake PD" W.G. 0.006 0.011 0.023 0.037 0.050 0.066 0.087 0.110 0.142 0.193 0.280 0.390
Exhaust PD" W.G. 0.007 0.014 0.028 0.044 0.059 0.080 0.10 0.128 0.159 0.255 0.310 0.425
12 0.875 1.125 1.375 1.625 1.875 2.125 2.375 2.625 2.875 3.125 3.375 3.625 3.875 4.125 4.375 4.625 4.875 5.125 5.375 5.625 5.875
16 1.458 1.875 2.292 2.708 3.125 3.542 3.958 4.375 4.792 5.208 5.625 6.042 6.458 6.875 7.292 7.708 8.125 8.542 8.958 9.375 9.792
CI - Air PHL - H
24 2.625 3.375 4.125 4.875 5.625 6.375 7.125 7.875 8.625 9.375 10.125 10.875 11.625 12.375 13.125 13.875 14.625 15.375 16.125 16.875 17.625
28 3.208 4.125 4.842 5.958 6.875 7.792 8.708 9.625 10.542 11.458 12.375 13.292 14.208 15.125 16.042 16.958 17.875 18.792 19.708 20.625 21.542
32 3.792 4.875 5.958 7.042 8.125 9.208 10.292 11.375 12.458 13.542 14.625 15.708 16.792 17.875 18.958 20.042 21.125 22.208 23.292 24.375 25.458
36 4.375 5.625 6.875 8.125 9.375 10.625 11.875 13.125 14.375 15.625 16.875 18.125 19.375 20.625 21.875 23.125 24.375 25.625 26.875 28.125 29.375
40 4.958 6.375 7.792 9.208 10.625 12.042 13.458 14.875 16.292 17.708 19.125 20.542 21.958 23.375 24.792 26.208 27.625 29.042 30.458 31.875 33.292
44 5.542 7.125 8.708 10.292 11.875 13.458 15.042 16.625 18.208 19.792 21.375 22.958 24.542 26.125 27.708 29.292 30.785 32.458 34.042 35.625 37.208
48 6.125 7.785 9.625 11.375 13.125 14.785 16.625 18.375 20.125 21.875 23.625 25.375 27.125 28.875 30.625 32.375 34.125 35.875 37.625 39.375 41.125
52 6.708 8.625 10.542 12.458 14.375 16.292 18.208 20.125 22.042 23.958 25.875 27.792 29.708 31.625 33.542 35.458 37.375 39.292 41.208 43.125 45.042
56 7.292 9.375 11.458 13.542 15.625 17.708 19.792 21.875 23.958 26.042 28.125 30.208 32.292 34.375 36.458 39.542 40.625 42.708 44.792 46.875 48.958
60 7.875 10.125 12.375 14.625 16.875 19.125 21.375 23.625 25.875 28.125 30.375 32.625 34.875 37.125 39.375 41.625 43.875 46.125 48.375 50.625 52.875
64 8.458 10.875 13.292 15.708 18.125 20.542 22.958 25.375 27.792 30.208 32.625 35.042 37.458 39.875 42.292 44.708 47.125 49.542 51.958 54.375 56.792
68 9.042 11.625 14.208 16.792 19.375 21.958 24.542 27.125 29.708 32.292 34.875 37.458 40.042 42.625 45.208 47.792 50.375 52.958 55.542 58.125 60.708
www.cic-jo.com
72 9.625 12.375 15.125 17.875 20.625 23.375 26.125 28.875 31.625 34.375 37.125 39.875 42.625 45.375 48.125 50.875 53.625 56.375 59.125 61.875 64.625
Table No. 5. Effective free area in ft2 (Ak Factor) for CI - Air PHL - H
19
Stationary Stormproof Louvers
CI - Air SSL - H
General:
Description:
Louvers can be supplied with galvanized bird or aluminium insect screen, volume control damper and
aluminium air filter of 1”, 2” and 4” thickness.
The filters are accessable from the side or backward of the louver depending upon type of installation and
must be specified by the customer.
These louvers are available in standard given sizes, however they can also be supplied in other requested
sizes and architectural shapes upon customers requirements.
CI - Air SSL-H louvers are made of heavy gauge extruded aluminium profiles.
They are available in white polyester powder coated finish or any other RAL standard colour upon
customer’s request.
Bird screens are made of galvanized expanded metal sheets.
Width in inch.
Height in inch.
Accessories:
B : Bird Screen
D :Volume Control Damper (VCD)
BD :Bird screen & VCD.
I :Insect Screen
F1 :Aluminium Filter 1” thick.
F2 :Aluminium Filter 2” thick.
F3 :Aluminium Filter 4” thick.
Dimensional Data
Example:
Example:
Louver size required for an exhaust requirements of 1200 CFM with a total pressure drop of 0.07” W.G.
1) From the pressure requirement table 7 it shows that a 600 FPM velocity results an exhaust pressure
drop of 0.07” W.G.
2) Determine the effective free area:
CFM
Effective free area Ak =
Vk
1200
= = 2.0 ft2
600
3) From table 8 the 2.0 ft2 effective area is mostly suitable for the size 42” x 18”.
Note:
For other louver sizes not shown in table 8. The approximate effective free area in square feet can be
calculated by using the following formula:-
Pressure Requirement:
Free Velocity (FPM) 200 300 400 500 600 700 800 900 1000 1200 1400 1600
Intake PD" W.G. 0.007 0.018 0.031 0.047 0.070 0.092 0.112 0.145 0.183 0.271 0.380 0.50
Table No. 7 Total pressure drop in inches of water as a function of face velocity in FPM for CI - Air SSL-H.
18 0.371 0.636 0.901 1.166 1.431 1.696 1.961 2.226 2.491 2.756 3.021 3.286 3.551 3.816
24 0.574 0.984 1.394 1.804 2.214 2.624 3.034 3.444 3.854 4.264 4.674 5.084 5.494 5.904
30 0.777 1.332 1.887 2.442 2.997 3.552 4.107 4.662 5.217 5.772 6.327 6.882 7.437 7.992
36 0.980 1.680 2.380 3.080 3.780 4.480 5.180 5.880 6.580 7.280 7.980 8.680 9.380 10.080
42 1.183 2.028 2.873 3.718 4.563 5.408 6.253 7.098 7.943 8.788 9.633 10.478 11.323 12.168
48 1.386 2.376 3.366 4.356 5.346 6.336 7.326 8.316 9.306 10.296 11.286 12.276 13.266 14.256
54 1.589 2.724 3.859 4.994 6.129 7.264 8.399 9.534 10.669 11.804 12.939 14.074 15.209 16.344
60 1.792 3.072 4.352 5.632 6.912 8.192 9.472 10.752 12.032 13.312 14.592 15.872 17.152 18.432
66 1.995 3.420 4.845 6.270 7.695 9.120 10.545 11.970 13.395 14.820 16.245 17.670 19.095 20.520
72 2.198 3.768 5.338 6.908 8.478 10.048 11.618 13.188 14.758 16.328 17.898 19.468 21.038 22.608
78 2.401 4.116 5.831 7.546 9.261 10.976 12.691 14.406 16.121 17.836 19.551 21.266 22.981 24.696
84 2.604 4.464 6.324 8.184 10.044 11.904 13.764 15.624 17.484 19.344 21.204 23.064 24.924 26.784
90 2.807 4.812 6.817 8.822 10.827 12.832 14.837 16.842 18.847 20.852 22.857 24.862 26.867 28.872
Table No. 8. Effective free area in ft² (Ak factor) for CI - Air SSL-H.