DEFIBSTART
Desfibrilador externo automatizado
Salvar vidas puede ser más fácil de lo que piensas

1 Monitor
Con ECG en pantalla
Pantalla de cristal liquido
LCD que muestra: Texto

2
comandos, latidos del corazon
detector, Cronometro,
Almohadillas Batteria estatus, 2min CRP
Tiempo de orientacion , BPM,

Desechables y curva ECGG

3
Longitud: aproximada. 3.5”

Ffacil y rapida conexion


Vida util : 24 meses Sistema
de baterias
Longitud de cable:: aprox.:1.0m
Disponible: Adulto y Pediatrico
manos libres electrodos

innovado
5 segundos para cambiarlo
Lithium-Polymer (Li-Po), 11.1 VDC, 2200mAh
Capacidad: Ability to perform up to 140 shocks (150J) on
a fully charged battery; or up to 5 Hours of continuous
ECG monitoring.
Low battery alarm - audible and visual
Battery Life: 5 Years (4 years recommended by the
manufacturer to be exchanged)

Accesorios Indicador de estatus de bateria] - , cargando, cargado, baja

Estuche de transporte Disposable pads Cargador] de baterias

Otros accesosios a peticion

SPo2 sensor ECG cable


Cable para ambulancia USB cable (adulto, pediatrico, neonatal) 3 leads
Be prepared and have the best
technology available for resuscitation
Key advantages
. AED with USB for data transfer* NEW . AED with pulse oximetry (SPO 2)*

Internal Memory to
Pulse Oximeter (SPO2)*
store
Pulse Reading Range:
1000 events
10 to 300BPM
Data transfer through
Tolerance: +/- 3%
USB port (Phoenix
SpO2 Reading Range:
Software)
0% to 100%
Accuracy: 70% - 100%

. AED with 12V DC input for ICU mobile* . AED with ECG option (3 lead cable)*

Standard: 3 lead
12V DC Input for ECG Patient Cable -
ICU Mobile derivation (DII)
Capture the ECG signal
via defibrillation
paddles or via ECG
Patient cable.
Heart rate reading
range: 10 to 300 bpm

. AED with override manual option* It allows the doctor to charge and deliver the shock at anytime. In 5
seconds, this option can be activated, and the device becomes a manual
defibrillator in the same energy protocol configuration of an AED.
* Pre configured options. Made upon request
Technical specifications Automated External Defibrillator - DEFIBSTART
General Battery
Model: DEFIBSTART Lithium-Polymer (Li-Po), 11.1 VDC, 2200mAh
Languages Available: English and Spanish Capacity: Ability to perform up to 140 shocks (150J) on a fully charged battery; or up
to 5 Hours of continuous ECG monitoring.
Defibrillation Low battery alarm - audible and visual
Biphasic Truncated Exponential (BTE) Waveform Battery Life: 5 Years (4 years recommended by the manufacturer to be exchanged)
Standard Discharge sequence:: Adult - 150 - 150 -150 Joules (other discharge Battery status indicator - Low, charging and charged
sequences upon request)
Pediatric mode: 50 - 50 - 50 Joules Defibrillation Electrodes (Disposable Pads)
Adult/Pediatric Selection: Automatic detection of paddle type - Pediatric paddle Shelf life: 24 months
limits the shock charge to a max of 50J Cable lengh: approx. 1.0m
Available: Adult and Pediatric hands-free electrodes
AED
Text and Voice Prompts Data Management*
Beep guidance for CPR (100 Comp/min) Optional: Internal Memory to store 1000 events
Impedance detection in the range of 25 Ohms to 300 Ohms for the shocking Data transfer through USB port (Phoenix Software)
procedures;
Automatic ECG Evaluation (shockable and unshockable arrhythmias) External charger
Maximum time from Power on - Patient Analysis - Shock delivery is approximately Input AC: 100 - 240 VAC – Automatic – 50/60 Hz
30 seconds Output DC: 12.6V 800mA
Optional of 12V DC for Ambulance *
Monitor
Liquid crystal display - LCD which displays: Text commands, Heart beat detector, Accessories (Standard)
Chronometer, Battery status, 2min CPR Timer for guidance, BPM and ECG Curve Adult Disposable Pads
Size: approx. 3.5” AED charger
Carrying Case
Dimensions User Manual
Weight: Approx. 4.18lbs (1.9Kg) Warranty Certificate
Dimensions: Approx. 11.5 x 9 x 6 in.
Accessories (Optional)
ECG* 3-Lead ECG Patient Cable
Standard: 3 lead ECG Patient Cable - derivation (DII) ECG Electrodes
Capture the ECG signal via defibrillation paddles or via ECG Patient cable. SPo2 sensor (adult, pediatric, neonatal)
Heart rate reading range: 10 to 300 bpm Pediatric Disposable Pads
USB Cable
Pulse Oximeter (SPO2)* Phoenix Software
Pulse Reading Range: 10 to 300BPM Ambulance Cable
Tolerance: +/- 3%
SpO2 Reading Range: 0% to 100% * upon request
Accuracy: 70% - 100% MADE IN USA