Cladding Specifications - Ifc Material Specs

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

FIXED FINISHES

ARCHITECTS PLANNERS & ENGINEERS TILE TL

PROJECT DEIRA MALL ITEM CODE TL-09

PROJECT NO A 048 ITEM BULKHEAD CLADDING, MATT

AREA CENTRAL AVENUE REVISION C0 PAGE 1 OF 4

SUPPLIER CROSS REFERENCE N/A


Contractor to provide approved alternative material, to be locally sourced.
LENGTH Refer to ID drawings
Refer to Special Requirements Box below, the specified material must
comply with all the requirements mentioned in the Special Requirements WIDTH Refer to ID drawnings
Box.
THICKNESS Refer to ID drawings
COMPOSITION NA
MANUFACTURER AS PER CLIENT APPROVED MANUFACTURER

TELEPHONE POSITIONING Refer to ID drawings.


DETAILS
FAX

DESCRIPTION Full body porcelain tile in a large 3000mm x 1000mm format, with a
thickness of just 5.6mm

FINISH Light Beige SPECIAL * This specification sheet is for the design intent of this project. The
REQUIREMENTS item specified is the recommendation of RSP to fulfill the design
1) All quantity requirements must be verified prior to installation. intent. The Contractor or Client can propose alternatives for
NOTES 2) Must be of contract quality and suitable for commercial use. approval if required for Value engineering or other Client
3) Specifications must comply with current Civil Defense/NFPA/EHS requirements, for ID review & approval, prior to installation.
regulations for the UAE. * Contractor to use, include and calculate the percentage of recycled
content as required by EHS Building Implementation.
* All adhesives and sealeants must comply with the requirements of
SCAQMD Rule No 1168 and GS-36. Materials with corresponding
product information shall be submitted to Client for review prior to
procurement.

IMAGE (image as intent only refer to actual sample)

TYPICAL STREET , CENTRAL AVENUE - TILECLADDING


The large format minimize the number of joints in tiling for aesthictic and hygiene benefits, durability, versatility, sustainability and special resistance to
chemical and trafiic, it is ideal low-maintenance matrial f or high traffic issues.

RSP ARCHITECTS PLANNERS & ENGINEERS


PREPARED BY BD CHECKED BY LA DATE 15/5/2018 Unit 3503 Marina Plaza, Dubai Marina, United Arab Emirates
TEL: (971) 4 4418456 FAX: (971) 4 4418274 WEBSITE: www.rsp.ae
FIXED FINISHES
ARCHITECTS PLANNERS & ENGINEERS TILE TL

PROJECT DEIRA MALL ITEM CODE TL-09

PROJECT NO A 048 ITEM BULKHEAD CLADDING, MATT

AREA CENTRAL AVENUE REVISION C0 PAGE 2 OF 4

RSP ARCHITECTS PLANNERS & ENGINEERS


PREPARED BY BD CHECKED BY LA DATE 15/5/2018 Unit 3503 Marina Plaza, Dubai Marina, United Arab Emirates
TEL: (971) 4 4418456 FAX: (971) 4 4418274 WEBSITE: www.rsp.ae
FIXED FINISHES
ARCHITECTS PLANNERS & ENGINEERS TILE TL

PROJECT DEIRA MALL ITEM CODE TL-09

PROJECT NO A 048 ITEM BULKHEAD CLADDING, MATT

AREA CENTRAL AVENUE REVISION C0 PAGE 3 OF 3

RSP ARCHITECTS PLANNERS & ENGINEERS


PREPARED BY BD CHECKED BY LA DATE 15/5/2018 Unit 3503 Marina Plaza, Dubai Marina, United Arab Emirates
TEL: (971) 4 4418456 FAX: (971) 4 4418274 WEBSITE: www.rsp.ae
FIXED FINISHES
ARCHITECTS PLANNERS & ENGINEERS TILE TL

PROJECT DEIRA MALL ITEM CODE TL-09

PROJECT NO A 048 ITEM BULKHEAD CLADDING, MATT

AREA CENTRAL AVENUE REVISION C0 PAGE 4 OF 4

RSP ARCHITECTS PLANNERS & ENGINEERS


PREPARED BY BD CHECKED BY LA DATE 15/5/2018 Unit 3503 Marina Plaza, Dubai Marina, United Arab Emirates
TEL: (971) 4 4418456 FAX: (971) 4 4418274 WEBSITE: www.rsp.ae

You might also like