Error Messages From Wirefeeder: Display Plain Text Remedy
Error Messages From Wirefeeder: Display Plain Text Remedy
Efd 8.4 Shortcut circuit of the PPU-motor am the PM43 Check the PPU-motor or the motorwires.
Efd 10.2 Internal Error Update, otherwise change the PM 41 board and
check the ribbon-cable connection
change the SR 41 board
Efd 10.5 Internal Error Update, otherwise change the PM 41 board and
check the ribbon-cable connection
change the SR 41 board
Efd 10.6 Internal Error Update, otherwise change the PM 41 board and
check the ribbon-cable connection
change the SR 41 board
Efd 15.1 Drahtpuffer leer Kontrolle des Schlauchpaketes und der Verschleißteile
Efd 15.2 Drahtpuffer voll Kontrolle des Schlauchpaketes und der Verschleißteile
Efd 15.3 kein Drahtpuffer angeschlossen
Efd 30.1 Keine LHSB Verbindung zur Stromquelle Kontrolle LHSB Kabel und Kabelbaum
Efd 30.3 Keine LHSB Verbindung zum Robacta Drive CMT Kontrolle LHSB Kabel und Kabelbaum
St.1 Eto (Time-out) alignment step is taking too long Start the procedure again
( > 20 sec.) Check the welding torch
Change the PM 41 board
Change the SR 41 board
St.2 Eto (Time-out) alignment step is taking too long Start the procedure again
(20 sec.) Check the welding torch
Change the PM 41 board
Change the SR 41 board
St2. E11 Step 2 was performed under no-load Feed the wire into the torch hosepack and close
Conditions the feed rollers in the wirefeeder and in the torch
re-start.
Err 1 Error in St.1 minimum vd Check the cables from the IWGT in the wirefeeder
no actual speed value for Motor 1 (VR) to the SR 41 board
Change the IWGT
Err 2 Error in St.1 maximum vd Check the cables from the IWGT in the wirefeeder
no actual speed value for Motor 1 (VR) to the SR 41 board
Change the IWGT
Err 3 Error in St.1 minimum vd Check the cables from the IWGT in the wirefeeder
no actual speed value for Motor 1 (VR) to the SR 41 board
Change the IWGT
Err 4 Error in St.1 minimum vd Check the cables from the IWGT in the Robacta
no actual speed value for Motor 2 (RD) Drive to the SR 41 board
Change the IWGT
Err 5 Error in St.1 maximum vd Check the cables from the IWGT in the wirefeeder
no actual speed value for Motor 1 (VR) to the SR 41 board
Change the IWGT
Err 6 Error in St.1 maximum vd Check the cables from the IWGT in the Robacta
no actual speed value for Motor 1 (VR) Drive to the SR 41 board
Change the IWGT
Err 8 Error in St.2 minimum vd Check the cables from the IWGT in the wirefeeder
no actual speed value for Motor 1 (VR) to the SR 41 board
Change the IWGT
Err 9 Error in St.2 minimum vd Check the cables from the IWGT in the Robacta
no actual speed value for Motor 1 (VR) Drive to the SR 41 board
Change the IWGT
Err 13 Error in St.1 maximum vd Check the cables from the IWGT in the Robacta
no actual speed value for Motor 2 (RD) Drive to the SR 41 board
Change the IWGT