Agilent Solutions For Shimaduz GC Systems

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

5991-0431EN_Shimadzu_Poster_Shimadzu 3/17/15 12:37 PM Page 1

Agilent Solutions for Shimadzu GC Systems


Improve the performance of your Shimadzu with Agilent columns and supplies Bring the benefits of Agilent GC Supplies for Shimadzu to your whole lab
• Switch to an Agilent Inert Flow Path for greatly improved data sensitivity Agilent Ultra Inert Liners for Shimadzu GCs
• Ensure clean gas for better reliability and instrument/column lifetime Whether you are analyzing active compounds for the environmental industry or screening
• Use parts specifically designed for your Shimadzu GC, for optimum reliability and robustness for drugs of abuse, Ultra Inert deactivated inlet liners help ensure an inert GC flow path for
higher sensitivity, accuracy, and reproducibility.
Liners for 17A, 2010, and 2014 Systems Ultra Inert Columns Confidence comes from consistent quality 30

Length Volume
Similar to
Shimadzu
Agilent
Ultra Inert
Similar to
Shimadzu
Agilent
Original
Phase ID (mm) Length (m) Film (µm) Temp Limits (°C) 7 in Cage
provided by proprietary manufacturing 25
Description ID (mm) OD (mm) (mm) (µL) Unit Part No. Deactivation Part No. Deactivation DB-5ms Ultra Inert 0.18 20 0.18 -60 to 325/350 121-5522UI
0.25 30 0.25 -60 to 325/350 122-5532UI
processes. These liners are rigorously

% breakdown for Endrin


Splitless Liners

Single taper, wool 3.5 5.0 95 5/pk 221-48335-01 8001-0160 0.25 60 0.25 -60 to 325/350 122-5562UI tested and certified to ensure: 20
221-48876-02 0.32 30 0.25 -60 to 325/350 123-5532UI
Double taper, drilled hole near top 3.5 5.0 95 5/pk 220-94734-01 8001-0158 DB-35ms Ultra Inert 0.18 20 0.18 50 to 340/360 121-3822UI
• Exceptional batch-to-batch uniformity 15
Double taper, drilled hole near bottom 3.5 5.0 95 5/pk 220-94734-02 8001-0159 0.25 30 0.25 50 to 340/360 122-3832UI to provide reproducible results
Straight-through 2.6 5.0 95 500 5/pk 220-94767-00 8001-0151 220-94767-00 8001-0101 0.32 30 0.25 50 to 340/360 123-3832UI 10
Split Liners DB-624 Ultra Inert 0.18 20 1.00 -20 to 260 121-1324UI • Low to no bleed or background
Straight with middle restriction 3.5 5.0 95 800 5/pk 221-41444-01 8001-0156 221-41444-01 8001-0106 0.25 30 1.40 -20 to 260 122-1334UI contamination for better peak integration 5
Straight with middle restriction, wool 3.5 5.0 95 800 5/pk 220-90784-00 8001-0157 0.32 60 1.80 -20 to 260 123-1364UI
Straight-through 3.4 5.0 95 860 5/pk 8001-0153 8001-0103 0.53 30 3.00 -20 to 260 125-1334UI • Superior coverage, even with highly 0
Direct Liners

For 0.53 mm id column 2.6 5.0 95 450 5/pk 220-94768-00 8001-0152 220-94768-00 8001-0102 Agilent's complete offering of GC columns is available in The 2015-2016 GC and GC/MS Essential active compounds, gives sharper peaks 0 50 100
Injections
Split/Splitless Liners
Chromatography & Spectroscopy Catalog. Download your PDF at www.agilent.com/chem/catalog and improves quantitation Agilent UI Liners (n=16) Agilent s tp Liners (n=8) Competitor
Single taper 3.4 5.0 95 5/pk 961-01480-07 8001-0154 8001-0104
Other Liners

PTV 1.25 3.5 95 100 5/pk 221-49300-00 8001-0163


Column Nuts With or without deactivated glass wool, certified Agilent Ultra Inert liners provide both low surface activity
SPME or Purge and Trap, straight 0.75 5.0 95 50 5/pk 220-94769-00 8001-0162
Similar to
Manufacturer
and highly reproducible sample vaporization, facilitating best-in-class delivery for active analytes.
Description Unit Part No. Part No.

Column nut, slotted, 6-sided 2/pk 221-32705-00 8001-0311


Liners for 14 Systems Certificate of Performance
Column nut, no slot, 6-sided 2/pk 221-41533-00 8001-0312
8002-0157 Ultra Inert Liner
Certified performance: Every Ultra Inert liner is packaged with a Certificate of Performance
Agilent Agilent
Length Volume Ultra Inert Original PTV, Strt W/bot Restrict, 2mm 5pk that you can peel and stick into your lab notebook for quick compliance reference.
Description ID (mm) OD (mm) (mm) (µL) Unit Deactivation Deactivation Liner Body Lot: A0023
Self Tightening Column Nuts
Split/Splitless Liners
Deactivation Lot: B39020 Easy traceability: The deactivation lot number is printed directly on the certificate; the liner
Description Part No.
2.0 mm middle gooseneck 3.4 5.0 99 850 5/pk 8001-0155 8001-0105 lot number and part number are permanently etched on the liner glass.
Agilent Self Tightening column nut for Shimadzu GC. Includes nut for SPL inlet, nut for standard detector 8001-0016
connection, 0.4 mm graphite/polyimide ferrules (10/pk) for 250 µm columns
Agilent Self Tightening column nuts for Shimadzu GC system. Includes nut for SPL inlet, nut for standard 8001-0017
85% Polyimide/15% Graphite Capillary Column Ferrules detector connection, 0.5 mm graphite/polyimide ferrules (10/pk) for 320 µm columns

Similar to Agilent Self Tightening column nuts for Shimadzu GC system. Includes nut for SPL inlet and nut for 8001-0018
Manufacturer standard detector connection, 0.8 mm graphite/polyimide ferrules (10/pk) for 530 µm columns
Model Fitting Size (in) Ferrule ID (mm) Column ID (mm) Hole Unit Part No. Part No. Agilent Self Tightening column nut for Shimadzu GC/MS. Includes nut for SPL inlet, nut for MS transfer 8001-0015
QP5000/5050 Standard MS 1/16 0.3 0.18 or smaller 1 10/pk 220-90700-01 8001-0224 line connection, 0.4 mm graphite/polyimide ferrules (10/pk) for 250 µm columns

1/16 0.4 0.25 1 10/pk 220-90700-02 8001-0221 Agilent Self Tightening column nut, for Shimadzu QP-2010 MS with MS adaptor on the inlet. Includes 8001-0020
2 nuts for MS system connections, 0.4 mm graphite/polyimide ferrules (10/pk) for 250 µm columns
1/16 0.5 0.32 1 10/pk 220-90700-03 8001-0222
1/16 0.8 0.53 1 10/pk 220-90700-04 8001-0223 Agilent vials, closures, and septa for Shimadzu GCs
QP2010 1/16
1/16
0.4
0.4
0.25
0.25
1
2
10/pk
10/pk
220-90418-14
225-19056-00
8010-0310
8010-0312
Autosampler Syringes, 1/pk

Similar to Mfr. Replacement


stop unknown peaks from impacting your results
1/16 0.5 0.32 1 10/pk 220-90418-15 8010-0311 Volume Needle Gauge/ Similar to Mfr. Syringe Replacement Plunger or

1/16 0.8 0.53 1 10/pk 220-90418-18 8010-0313


Model (µL) Description Length (mm)/Tip Syringe Part No. Part No. Needle Part No. Needle Part No.
• Cleanliness and consistency for precision lab work
AOC-14, AOC-17, AOC-20 5 Fixed needle 23/42/cone tip 8001-0001
AOC-14, AOC-17, AOC-20 10 Removable needle 23/42/cone tip 220-90282-20 8001-0004 220-90281-20 8001-0005, 2/pk • Engineered with the same quality as Agilent instruments
Graphite Capillary Column Ferrules AOC-14, AOC-17, AOC-20 Removable needle 26/42/cone tip 220-90282-21 8001-0006 220-90281-21 8001-0007, 2/pk

Similar to
AOC-14, AOC-17, AOC-20 50 Fixed needle 23/42/cone tip 221-45243-00 8001-0002 • Wide selection: choose the right vial for your needs at
Model Fitting Size (in) Ferrule ID (mm) Column ID (mm) Hole Unit
Manufacturer
Part No. Part No.
AOC-14, AOC-17, AOC-20 250 Fixed needle, gas tight 23/42/cone tip 221-45244-00 8001-0003
www.agilent.com/chem/SelectVials
2010, 2010 Plus, 2014, 1/16 0.4 0.25 1 10/pk 220-90765-00 8001-0211*
17A, 14A
1/16 0.5 0.32 1 10/pk 221-32126-05 8001-0212* Non-Stick Inlet Septa for Shimadzu GC Systems
1/16 0.8 0.53 1 10/pk 221-32126-08 8001-0213*
Similar to
*Compatible for use with Self Tightening column nuts for Shimadzu. Manufacturer Part No. Part No.
Description Part No. 50/pk 100/pk

Non-Stick Bleed and Temperature Optimized (BTO) Septa


85% Polyimide/15% Graphite Packed Column Ferrules Shimadzu plug
Non-Stick Advanced Green Septa
8010-0231 8010-0232
From injection through instrument…
Similar to

Model Fitting Size (in) Ferrule ID (in) Column OD (in) Hole Unit
Manufacturer
Part No. Part No.
Shimadzu plug 220-90547-00 8010-0215 8010-0216 count on Agilent for everything that touches your sample
220-94781-00
QP5000/5050 Standard MS 1/4 1/4 1/4 1 10/pk 225-09028-00 8010-0314 General Purpose Septa
QP5000/5050 Wide Bore MS 1/16 1/16 1/16 1 10/pk 220-90418-28 8010-0315 Shimadzu plug 8010-0263 8010-0264
Your first choice for Put decades of Deliver the cleanest gas Minimize downtime
QP2010 1/16 1/16 1/16 1 10/pk 8010-0315 reproducible sample prep Agilent innovation for your most on your non-Agilent
17A 5 mm 5 mm 5 mm od 1 10/pk 221-46403-92 8001-0214
behind every separation reliable analysis GC instruments
The cross references to the Shimadzu part numbers listed here serve as a recommendation
that the Agilent products are viable alternatives to Shimadzu products. Agilent products are
compatible with the corresponding Shimadzu instruments, although in some cases, the
Liner O-rings Agilent products may have slightly different designs as compared to the Shimadzu
counterparts. All Agilent supplies are backed by Agilent's 90-day money-back warranty.
Similar to
Manufacturer
Description Unit Part No. Part No.

Non-stick fluoroelastomer O-ring 10/pk 036-11203-84 8001-0201


Graphite O-ring, split 10/pk 221-48393-91 8001-0202
Graphite O-ring, splitless 10/pk 221-47222-91 8001-0203 Agilent Sample Prep products: Agilent J&W GC columns: Agilent Gas Clean filters: Agilent Services:
To learn more about Agilent Solutions for Shimadzu GC Systems, Agilent Bond Elut SPE, Bond Elut • Largest portfolio of innovative • Keep gas lines clean and leak-free • Shimadzu
QuEChERS and Captiva Filtration GC columns, over 3,700 instrument services
visit agilent.com/chem/ShimadzuGCSupplies Sample Prep family of products offer • Best inertness, lowest bleed,
• Protect your instrument and GC
column with sensitive indicators • Compliance
the widest range of solutions for every tightest reproducibility
level of sample cleanliness to help • Stabilize quickly to enhance • Laboratory
you increase throughput and • Quality ensured by most productivity and reduce helium relocation services
increase the quality of your data. stringent testing in the industry gas consumption

This information is subject to change without notice.


© Agilent Technologies, Inc. 2015
Printed in USA March 17, 2015
5991-0431EN

You might also like