NOTES
Y
U
U
B
B
to
to
ww
ww
om
om
k
k
lic
lic
C
C
.c
.c
w
w
tr re tr re
.
.
ac ac
k e r- s o ft w a k e r- s o ft w a
+7.90 +7.90
GENERAL
3,500
23 23
2T12-23 All dimensions are shown in mm
T8-150-01'
T8-150-01'
150
23
900
900
300
unless otherwise
'
01
4T16-02 5T16-06
150
300
300
specified
LINKS: T8-150-01' 23 23 23 +7.00 +7.00 +7.00 +7.00
200
200
200
200
200
SECTION 23-23
3T12-23 23
Only figured dimensions to be
M Q
used.
BM19: 300X200MM
The contractor must check
2,950 and verify all dimensions on site
2T12-24 4T16-02 4T16-04 5T16-06 5T16-08
before commencement of worK
24
CONSTRUCTION
24 24
150
300
300
300
LINKS: T8-150-01' 02 02 04 04 06 06 08 08
'
01
150
3,300
3,300
3,300
3,300
24 24
All slabs at ground to be poured
T8-150-01'
T8-150-01'
T8-150-01'
T8-150-01'
2T12-24 24 200
SECTION 24-24
over 1000 gauge polythene sheet
M BM20: 300X200MM Q DPM
on 50mm thick stone dust or
3,100 murram
7,900
7,900
2T12-25 on approved grade hardcore
25 25 25
+3.50 +3.50 +3.50 +3.50 fillings.
150
7,000
7,000
All soil under the slabs
300
150 150
150 150
150 150
150 150
300
300
'
01
LINKS: T8-150-01'
300
300
300
300
150
25 25 and all around external
foundation to be
200
2T12-25 25 SECTION 25-25
T8-150-01'
T8-150-01'
T8-150-01'
T8-150-01'
2T12-26 26 26
All soils on cut embarkment
26
150
to be stabilised. The slope not to
3,200
3,200
3,200
3,200
300
'
01
300
300
150
LINKS: T8-150-01'
26 26
4T16-01 4T16-03 5T16-05 5T16-07
exceed the natural angle of
repose.
200
SECTION 26-26
2T12-26 26
STRUCTURAL
B BM22: 300X200MM D
300
300
300
300
300
300
300
300
G.B: 200X200MM G.B: 200X200MM G.B: 200X200MM G.B: 200X200MM
all buildings andpaved surfaces
300
300
'
01
150
2T12-27 27 27 27 COLUMN C01: COLUMN C02: COLUMN C03: COLUMN C04: details
200 200x200 MM 200x200 MM 300x200 MM 300x200 MM
SECTION 27-27 Depth of foundations to be
2 BM23: 300X200MM 5
determined
200 200 200 200
300 300
300 300
on site to Structural Engineers
approval.
01 01 02 02 07 07 08 08
01' 01' 03 03 04 04 01' 01'
200
200
200
200
01' 01' 05 05 05 06 06 06
200
200
01' 01' 07 07 08 08
200
200
01 01 02 02 03 04
03 04
1,900 05 05 05 06 06 06
COLUMN C01:
SECTION 01-01
COLUMN C01:
SECTION 02-02 COLUMN C02: COLUMN C02:
COLUMN C03:
COLUMN C04:
SECTION 07-07
COLUMN C04:
SECTION 08-08 All walls less than 200mm thick
3T12-28
SECTION 03-03 SECTION 04-04 COLUMN C03:
SECTION 05-05 SECTION 06-06
300
300
LINKS: T8-150-01'
'
01
28 28
1,000
1,000
1,000
1,000
150
300
300
LINKS: T8-150-01'
300
'
01
150
29 29 REVISIONS
2T12-29 29
NO DESCRIPTIONS DATE
200
SECTION 29-29
150
150
BM25: 300X200MM 5 150MM THK 150MM THK
300
300
G.SLAB G.SLAB
4T12 4T12
1,700
1,700
2,000
2,000
T8-100 T8-100
01 01 02 02 PROJECT DETAILS
CONSULTANT:
250
250
LOCATION:
50MM Thk blinding 50MM Thk blinding
50
50
concrete concrete
1,000
1,400
DRAWN BY:
CHK'D BY:
SCALE: AS SHOWN
5T12-01-150B2
DATE: APRIL - 2020
7T12-01-150B2
DRAWING TITLE
1,400
1,000
BEAM, COLUMNS AND FOOTING
DETAILS
5T12-01-150B1
7T12-01-150B1
1,000 PAPER SIZE: A0
1,400
COLUMN BASE CB1 DRAWING CODE / SHEET NUMBER
COLUMN BASE CB2