INSTALLATION, OPERATION & MAINTENANCE MANUAL

Stainless Steel Cartridge Filters

MODELS
SSC-1 To SSC-600
I N T ROD U C T I O N

Fill in the following information and have it ready when calling for assistance. The serial number
is found on the specification plate located on the system.

Purchased From

Date of Purchase

Model No.

Serial No.

REV. A
APRIL 2018

II 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
IN T ROD UC T ION

INTRODUCTION
This manual provides safety, installation, and operating procedures for the Pure Aqua, Inc.
reverse osmosis system. We recommend that all information contained in this manual be read
prior to installation and operation of the system. Your Pure Aqua system is manufactured from
the finest materials available and is assembled to good quality standards. This system has been
tested at the factory to ensure dependable trouble-free operation.

SERVICE/TECHNICAL ASSISTANCE
If you experience any problems with the installation or operation of your system, contact:
Pure Aqua, Inc. at 1 - 71 4 - 4 3 2 - 9 9 9 6 , or email: s u p p o r t @ p u r e a q u a . c o m

TERMS AND CONDITIONS OF SALE

ORDER ACCEPTANCE: Pure Aqua, Inc. reserves the right to accept or reject any order request.
Possession of a price sheet or a product catalog shall not be construed as an offer to sell the
product listed. Pure Aqua sells wholesale only and does not sell to end users. These terms and
conditions shall be considered a part of all accepted orders and accepted purchase orders.

CANCELLATION OR CHANGE OF ORDER: Orders are processed as they are received. Once an
order is in process (or production), add-ons (or change of orders) may hold up shipment of the
original order (or build), or may be shipped as a separate order. Buyer’s add-ons or changes to
orders are subject to Pure Aqua acceptance. Cancellations are subject to Pure Aqua acceptance
and may incur a minimum 25% restocking fee.

CUSTOM EQUIPMENT: Custom equipment is subject to the terms and conditions detailed on the
separate Pure Aqua quote form and may require a minimum 35% down payment.

PRICES: Products are sold at prices currently in effect at time of order, and are ex works Santa
Ana, CA USA unless otherwise specified. Prices generally coincide with dated Pure Aqua printed
price sheets and web site information. However, Pure Aqua reserves the right to change prices
at any time, without notice and without updating published material on our website or in print.
Freight costs are for the customer’s account.

DELIVERY: Stock items distributed by Pure Aqua are generally shipped within 1 to 4 working
days after receipt of order. Additional time is required on special orders, large orders, or
items not stocked. Pure Aqua is not responsible for delays due to conditions beyond our
control. Orders will be delayed, or not processed, where accounts are found delinquent and no
arrangements have been made with the Credit Department to settle the account.

SHIPPING CHARGES: All shipments are ex works Santa Ana, CA USA, unless otherwise specified
and shipping costs are the customer’s responsibility.

REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A III


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
I N T ROD U C T I O N

TERMS OF PAYMENT:

1. Via Wire Transfers


2. Via Letter of Credit (L/C)
• Letter of credit must be irrevocable, advised and confirmed through any MAJOR
bank in the United States with draft payable at sight.
• Letter of Credit must state that all bank charges inside and outside the United
states are to be borne by the opener.
A minimum purchase requirement of $250 is necessary to help defer handling.

OPEN ACCOUNT: To establish an open account, a complete credit analysis is required. This
involves correspondence with you, your suppliers, and your bank. The time involved depends
on the response time from the references you give us. You will be notified when your credit is
approved. In the interim, all orders must be prepaid.

NO OPEN ACCOUNT TERMS FOR CUSTOMERS OUTSIDE OF THE UNITED STATES.

DAMAGED MERCHANDISE: Pure Aqua is not responsible for damage or loss to a shipment by a
freight carrier. Check shipments for damage before acceptance or note on freight bill “Subject
to inspection for concealed damage.” Consignee is responsible for filing a claim with the freight
carrier for any and all damages or losses.

Return of Damaged Goods will not be authorized.

ERRORS AND RETURN GOODS AUTHORIZATION: No returns will be accepted without prior
authorization. Call Pure Aqua for an RGA number. Freight/shipping must be prepaid. An RGA
not used in 30 days will expire. A return after that will be refused and invoice will be payable
within terms. Special order goods are not returnable. All authorized returns are subject to a 25%
restocking fee.

DEFECTIVE GOODS & WARRANTY PROCESSING: An item returned for warranty consideration
without prior authorization will be refused. Call Pure Aqua for an RGA number. Pure Aqua and
its manufacturers reserve the right to repair or replace defective merchandise. If pre-warranty
replacement merchandise has been sent and the warranted goods are repairable, the repaired
product will be returned to you at our expense and the pre-warranty invoice will be for your
account. If the warranted product is not repairable, an offsetting credit invoice will be issued to
your account. If the warranty consideration is denied, all expenses are for your account.

REV. A
APRIL 2018

IV 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
IN T ROD UC T ION

LIMITED WARRANTY:
Products manufactured by Pure Aqua are warranted to be free of defects in material and
workmanship for a period of one year from the system start up and commissioning, or fourteen
months from the ship date, whichever comes first. Pure Aqua’ s responsibility and liability shall
be limited solely and exclusively to the replacement or the repair of parts manufactured by Pure
Aqua and will not be liable for any cost arising from removal, installation, transportation or any
other charges that may arise in connection with the warranty claim. Products and/or system
components sold by Pure Aqua and manufactured by others are subject to the warranty provided
by the manufacturer of said products and/or components and not by Pure Aqua’ s warranty.
Pure Aqua will not be liable for damage to products caused by incorrect operation, misuse,
abuse, unauthorized alteration, repair, accident or if products were not installed and operated
in accordance to the Pure Aqua operation and installation manual. Pure Aqua will not be liable
for any incidental or consequential damages, losses, or expenses arising from installation, use
or any other causes.

Pure Aqua, In c. an d its sup plie r s re s e r ve th e righ t to re pair o r re p lac e


de fe ct ive go o ds . A ll re turn s mus t b e auth o rize d.
Defe ct ive pro duct mus t be re turn e d to Pure Aq ua, In c . ONLY af te r
o bt ain in g a Re t urn e d Go o d s Auth o rizatio n (RG A ) n umb e r.
A ll re turn s m us t b e s e n t Fre igh t Pre paid.
A ll re turn s are s ub j e c t to a 25% re s to c kin g fe e .

PUR E AQUA WI LL NOT BE LIABLE FOR ANY INCIDE NTAL OR


C O NSEQUENT IA L DA M AGE S, LOS S E S, OR E XPE NS E S ARIS ING
F ROM I NS TA LLAT ION , US E , OR ANY OTHE R CAUS E S.

T H ER E A R E NO EX PR ESS OR IMPLIE D WARRANTIE S ; INCLUDING


M E RCHA NTA BILIT Y OR FITNE SS FOR PARTICULAR PURPOS E ,
W H ICH EX T ENDS BEYON D THOS E WARRANTIE S, DE S CRIBE D OR
R EF ERRE D TO THE ABOVE .

WHERE JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL


OR CONSEQUENTIAL DAMAGES, THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT
APPLY.

DISCLAIMER: No part of this document may be copied or reproduced in any form or by any
means without the prior written permission of Pure Aqua, Inc. Pure Aqua, Inc. makes no
warranties with respect to this documentation. Information in this document is subject to
change without notice. Pure Aqua, Inc. shall not be liable for technical or editorial errors or
omissions that may appear in this document; nor for incidental or consequential damages
resulting from the furnishing, performance, or use of this document.

REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A V


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
I N T ROD U C T I O N

IMPORTANT SAFET Y INFORMATION


NOTES, CAUTIONS AND WARNINGS
Throughout this manual, you will encounter the words NOTE, CAUTION, and WARNING. These
are intended to emphasize certain areas in the interest of operator safety and satisfactory
system operation/maintenance. The definitions of these words are as follows:

NOTE
A NOTE contains highlighted information regarding practices or procedures that
may save time and lessen problems for personnel who use the equipment
or system covered herein.

CAUTION!
A CAUTION contains pertinent information regarding practices or procedures
which, if not carefully observed, may result in damage to or destruction of the
equipment or system covered herein.

WARNING!
A WARNING contains vital information regarding processes which, if not strictly
observed, may result in injury to personnel.

In addition to the warnings and cautions in this manual, use the following
guidelines for safe operation of the system.
► Read all instructions before using equipment.
► Install the equipment only for its intended use as described
in this manual.
► Do NOT use corrosive chemicals with this equipment.
► Do NOT operate this equipment if it has a damaged cord or
plug; if it is not working properly, or if it has been damaged or
dropped.
► This equipment should be serviced and operated by qualified
personnel trained in servicing RO and water treatment
systems.
► Do NOT immerse cord or plug in water.
► System should only be supplied with water at it’s designed
temperature.
► Keep cord away from heated surfaces.
► The Pure Aqua RO-400 system is NOT designed to be used
in pharmaceutical or medical applications; it is intended for
drinking water applications only.

REV. A
APRIL 2018

VI 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
IN T ROD UC T ION

WARNING!

ELECTRICAL SHOCK HAZARD

FA ILUR E T O FOL LOW THESE IN S TRUCTION S


C O UL D R E SULT IN SER IOUS IN JURY OR DEATH.

► Do not use an extension cord with this appliance.


► If any cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person.
► This equipment is to be installed in compliance with all local
electrical codes.

CAUTION!
A LWAYS D IS C ON N ECT THE POW ER SOURCE
B E FO R E PE R FOR MIN G AN Y SERV ICE OR
M A INT E N AN CE ON THE SYS TEM.

A L L E L E C T R ICA L CON N ECTION S MUS T B E IN


AC C O R DA NC E W ITH LOCAL EL ECTR ICAL CODES
A ND A NY OT HER APPL ICAB L E CODES.

WARNING!
D O NOT OV E R -T I GHTEN CON N ECTION S OR THEY
MAY SPL IT
► Tighten 1-2 turns beyond finger tight. It is recommended that plastic fittings be used
when connecting to the system’s plastic connections. This will reduce the possibility
of cracking the connections due to over-tightening.

REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A VII


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
I N T ROD U C T I O N

SAFETY PRACTICES
Handling chemicals can be extremely dangerous and the utmost care must be taken in
observing proper precautionary measures to prevent injury to personnel. It is the purchaser’s
responsibility to ensure that personnel are properly trained in handling chemicals.

Some general rules for safely handling chemicals are:

► Know where and how first aid is immediately available.


► Always wear or use applicable protective clothing and equipment for eyes,
face, neck and hands.
► Do not allow chemicals to come in contact with eyes, skin, or clothing.

WARNING!
A LWAYS A D D C HEMICAL TO WATER . N EV ER
A D D WAT E R T O CHEMICAL W HEN MIX IN G
SOLUTION S.
► Always add chemicals to water slowly and in small portions to
avoid any explosions, boil spattering, or other violent reactions.

WARNING!
R E M A IN I N WEL L -V EN TIL ATED AR EA W HEN
H A ND L ING C H E MICAL S, GR AN UL AR MEDIA ,
O R POW D E R E D MEDIA TO AVOID IN HAL IN G
H A R M F UL FUMES OR DUS T.

WARNING!
NE V E R E NT E R A TAN K OR AN EN CLOSED SPACE
T H AT I S S UB J E CT TO CHEMICAL FUMES OR
M E D I A D US T WITHOUT PROPER V EN TIL ATION
A ND S TA ND BY PER SON N EL IN ATTEN DAN CE.

CAUTION!
DO N OT E XCE E D TH E M A X IM U M F EED PR ES SU R E

THE SYS T E M MUS T BE PROTEC TED F RO M H IG H F EED


PR E S S UR E OVE R 6 0psi . IF TH E F EED WATER S O U RC E
PR E S S UR E IS G R EATER TH A N 6 0 psi A PR ES S U R E
CO N T RO L VA LV E M U S T BE U SED .
REV. A
APRIL 2018

VIII 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
IN T ROD UC T ION

SYSTEM CARE & PRECAUTIONS

PROTECT AGAINST DRYING


Some media, seals, or other components may be damaged by drying. Protect the equipment
from drying by keeping it wet and sealed at all times. If in storage, keep systems in a cool place.

PROTECT AGAINST FREEZING


If the system freezes during operation or storage, irreversible damage may result. Freezing
conditions make many materials to become brittle, and water expands as it freezes. This
combination cracks piping, valve seals, and other components.
PROTECT AGAINST DIRECT SUNLIGHT OR OTHER UV SOURCES
Avoid long-term exposure to direct sunlight or other UV sources. The equipment should be
stored in a shaded location. UV light causes materials to become brittle and susceptible to
breaking.
PROTECT AGAINST HIGH TEMPERATURES OR ABRUPT
VARIATION IN TEMPERATURE
The maximum operating temperature is 104°F (40°C). Temperatures above this can
cause PVC to deform and possibly rupture. Avoid abrupt variations in temperature. Any
temperature variation should be made slowly. Fast temperature transitions can lead to de-
lamination of the constructed materials.
PROTECT AGAINST ROUGH HANDLING OR DROPPING
Mechanical damage, external breakage and/or internal breakage of the equipment
can result if the system is dropped or bumped. Handle with care at all times during
transportation and installation.
PROTECT AGAINST ORGANIC SOLVENTS AND CONCENTRATED ACIDS
Prevent any and all contact of the system with strong solvents, solvents containing chlorine,
or concentrated acids.
Do not use strong solvents or concentrated acids on any plastic parts of the equipment
system. Examples of some solvents to avoid: acetone, methyl acetate (nail polish remover);
hexane (spot removers); turpentine, toluene (paint thinners); dry cleaning solutions,
insecticides.
PROTECT AGAINST ABRASIVE MATERIAL
Materials subject to wear such as valve seals must be protected from abrasive materials
like shavings left in a pipe.
Abrasive materials in contact with these materials can cause irreversible damage. All pipes
must be flushed clean before installing the system. All plastic parts of the equipment
system must be protected from sharp objects like knives, sand paper, or other tools. Cutting
or nicking a plastic part can weaken it and cause a leak. Do not use abrasive cleansers on
any plastic parts.
REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A IX


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
I N T ROD U C T I O N

THIS PAGE HAS BEEN


INTENTIONALLY LEFT BLANK

REV. A
APRIL 2018

X 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL CARTRIDGE FILTERS

MODELS
SSC-1 To SSC-600
STAINLESS STEEL FILTER HOUSINGS

CARTRIDGE FILTERS
The Pure Aqua, Inc. SSC line of cartridge filter housings are constructed of all stainless
steel components. They range in size from a single 10” filter cartridge all the way up to a
150x 40” cartridge capacity with maximum flow rates ranging from 6 gpm up to 3,000 gpm.

There are 3 distinct housing styles across the product line. The following pages will cover
the specifications and filter change procedures for each style housing.

Single Filter Housing: SSC-1 thru SSC-3


The SSC-1 thru SSC-3 are single filter housings constructed of 304 Stainless steel. These
housings feature a fixed top with a cartridge housing secured by a threaded collar. The top
portion has either a 3/4” or 1” FNPT inlet and outlet ports. At the base of the filter housing
is a 1/4” twist drain.

Model Number of Cartridge Pipe Size Max. Flow Rate Drain


Number Cartridges Size GPM (LPM) Size
SSC-1 1 10” 3/4” NPT 6 (23) 1/4”

SSC-2 1 20” 3/4” NPT 12 (45) 1/4”

SSC-3 1 30” 3/4” NPT 6 (23) 1/4”

Each filter housing is supplied with a mounting bracket and a collar wrench.

Mounting Bracket

NOTE
The filter housing should always be relived of
internal pressure before attempting to open
Collar Wrench the housing.

Filter Change Intervals


The filter cartridge will need to be replaced once a pressure differential of
15 psi is observed across the filter. If the filter has been in use for more than
30 days, it should be replaced regardless of the pressure differential or how
clean it may appear.

Most types of filter cartridges break down over time. As the filter breaks down,
it loses its filtering capacity and can cause harmful particles to pass through
potentially damaging downstream equipment.

Details on the various types of replacement cartridges for your model SSC can
be found at the end of this manual.

REV. A
APRIL 2018

2 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

Cartridge Filter Replacement


1
To change the cartridge filter you will need
the collar wrench. The filter housing must be
secured to its bracket when attempting to loosen
the collar .
Drain Port
1. Open the drain valve at the bottom of
the filter housing to bleed off internal
pressure.
2
2. Insert the collar wrench into one of
the side holes on the collar and turn
clockwise as viewed from the top of
the filter.
3. Remove the lower half of the housing
with the collar. Remove the filter and
thoroughly rinse the housing free of
any debris.
4. Inspect the 2 o-rings on the housing
3
lid. Clean and lube the o-rings with
Dow 111 food grade lubricant.
5. Place a new cartridge in the housing.
Remember to remove the plastic
wrapper from the cartridge.
6. Insert the housing onto the lid
taking care not to mar the o-rings.
The housing my need to be pushed 4
upwards with a bit of force while
threading the collar back on. This is
normal as there is a spring seat inside
that helps ensure a sealed fit of the
filter cartridge.
6
7. Thread the collar back on taking care
not to cross-thread it. Use the collar
wrench to tighten the collar.
Do not over tighten.
8. Close the drain valve and resume
operation.

REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A 3


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

Filter Housing: SSC-4 thru SSC-21


The SSC-4 thru SSC-21 are multi cartridge filter housings constructed of 304 or optional
316L Stainless Steel. These filter housings feature flanged interfaces, an air vent valve, and
two drain ports. The upper drain port allows the dirty partition of the housing to be drained
separately, minimizing contamination of the clean partition.

Model Number of Cartridge Connection Max. Flow Rate Drain


Number Cartridges Size Size GPM (LPM) Size
SSC-4 4 10” 24 ( 91 )

SSC-5 5 10” 3 0 ( 114 )

SSC-8 4 20” 4 8 ( 18 2 )

SSC-10 5 20” 6 0 ( 2 27 )

SSC-1 2 4 30”
2"
7 2 ( 27 3 )
1/2”
MNPT
SSC-14 7 20” 8 4 ( 318 )

SSC-15 5 30” 9 0 ( 341 )

SSC-16 4 40” 96 (364)

SSC-20 5 40” 120 (455)

SSC-21 7 30” 1 2 6 ( 47 8 )

Filter Change Intervals


The filter cartridge will need to be replaced once a pressure differential of 15 psi is observed
across the filter. If the filter has been in use for more than 30 days, it should be replaced
regardless of the pressure differential or how clean it may appear.

Most types of filter cartridges break down over time. As the filter breaks down, it loses its filtering
capacity and can cause harmful particles to pass through potentially damaging downstream
equipment.

Details on the various types of replacement cartridges for your model SSC can be found at the
end of this manual.

Cartridge Filter Replacement


The following instructions apply to SSC-4 thru 21 series filter housings.
Items denoted with ” *” are optional accessories.

1. Locate the filter housing and open the Air Vent Valve* (A) at the top of the filter lid to
relieve any residual pressure.

2. Open both filter Drain Valves* (B) at the bottom of the filter housing and allow the
filter to drain completely.

REV. A
APRIL 2018

4 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

C
3. Once all the water has drained from the filter housing
Unscrew the wing nut on the filter Lid Retaining Ring (C) and A
remove the retaining ring and lid.
4. Remove and inspect the rubber O-Ring (D) from the
housing. Remove any dirt and old lubricant with a clean
rag. Lubricate the Rubber O-ring with Dow 111 food grade
O-ring lubricant before replacing. D E
5. Unscrew the Wing Nut (E) holding the filter Retaining Plate
(F) in place and remove the Retaining Plate along with the
Spring Caps (G). F

6. Inspect the inside of the housing for debris and rinse the G
housing out with clean water before removing the filter
cartridges. Leave the Drain Valves* (B) open while rinsing
to allow any dirt and debris to be flushed from the filter.
7. Remove and dispose of the old filter
cartridges. Install the new Filter
Cartridge(s) (H) making sure to seat H
each filter as shown in the cross section
view , right.
Be sure to remove the plastic
wrapping from the filters before
use.
8. Install the Spring Caps, Retaining Plate,
O-Ring, Lid Retaining Ring and Lid in
the opposite order of in which they
were disassembled.

ID ITEM
A VENT VALVE*
B FILTER DRAINS*
C LID RETAINING RING
D LID O-RING SEAL
B
E WING NUT
F RETAINING PLATE
SSC Filter Cross Section and Assembly
G SPRING CAPS
H CARTRIDGE FILTERS

REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A 5


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

Filter Housing: SSC-24 thru SSC-600


The SSC-24 thru SSC-600 are multi cartridge filter housings constructed of 304 or optional
316L Stainless Steel. These filter housings feature flanged interfaces, an air vent valve, and
two drain ports. The upper drain port allows the dirty partition of the housing to be drained
separately, minimizing contamination of the clean partition.

Model Number of Cartridge Flange Size Max. Flow Rate Drain


Number Cartridges Size GPM (LPM) Size
SSC-24 6 40” 3” 14 4 ( 54 6 )

SSC-28 7 40” 3” 16 8 ( 6 37 )

SSC-36 9 40” 3” 216 ( 819 )

SSC-48 12 40” 4” 288 (1,092)

SSC-66 22 30” 4” 3 9 6 ( 1 , 5 01 )

SSC-88 22 40” 6” 5 2 8 ( 2 , 0 01 )

SSC-108 27 40” 6” 6 6 0 ( 2 , 5 01 )
1/2”
SSC-144 36 40” 6” 720 (2,729)
FNPT
SSC-168 42 40” 6” 1, 0 0 8 ( 3 , 8 2 0 )

SSC-220 55 40” 8” 1, 3 2 0 ( 5 , 0 0 3 )

SSC-244 61 40” 8” 1, 4 6 4 ( 5 , 54 9 )

SSC-292 73 40” 8” 1, 7 5 2 ( 6 , 6 4 0 )

SSC-390 98 40” 10” 2,340 (8,869)

SSC-480 120 40” 10” 2 , 8 8 0 ( 10 , 915 )

SSC-600 150 40” 10” 3 , 0 0 0 ( 11 , 37 0 )

Filter Change Intervals


The filter cartridge will need to be replaced once a pressure differential of 15 psi is observed
across the filter. If the filter has been in use for more than 30 days, it should be replaced
regardless of the pressure differential or how clean it may appear.
Most types of filter cartridges break down over time. As the filter breaks down, it loses its filtering
capacity and can cause harmful particles to pass through potentially damaging downstream
equipment.
Details on the various types of replacement cartridges for your model SSC can be found at the
end of this manual.

Cartridge Filter Replacement


The following instructions apply to SSC-24 thru 600 series filter housings.
Items denoted with ” *” are optional accessories.
1. Open the Air Vent Valve* (A) at the top of the filter housing lid.
2. Open both filter Drain Valves* (B) at the bottom of the filter housing and allow the
filter to drain completely.
3. Once all the water has drained from the filter housing Unscrew all the eye nuts on
the filter lid (C) and remove the lid. Be careful not to pinch or tear the O-ring when
removing the lid.
REV. A
APRIL 2018

6 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

4. Remove and inspect the rubber O-Ring (D). Remove any A


dirt and old lubricant with a clean rag. Lubricate the
Rubber O-ring with Dow 111 food grade O-ring lubricant
before replacing. Dispose of and replace if the O-ring has
any tears.
5. Unscrew the Wing Nut(s) (E) holding the filter Retaining E
Plate (F) in place and remove the Retaining Plate along F
with the Spring Caps (G).
6. Inspect the inside of the housing for debris and rinse
the housing out with clean water BEFORE removing the
Filter Cartridges (H). Leave the Drain Valves* (B) open while
rinsing. G

ID ITEM C
A VENT VALVE* D
B FILTER DRAINS*
C EYE NUTS
D LID O-RING SEAL
E WING NUTS
F RETAINING PLATE
G SPRING CAPS H
H CARTRIDGE FILTERS

Filter Dirty Partition

Filter Seat

Clean Partition

SSC Filter Cross Section and Assembly

7. Install the new Filter Cartridge(s) (H) making sure to seat each filter as shown in the
cross section view above.

Be sure to remove the plastic wrapping from the filters before use.
8. Install the Spring Caps, Retaining Plate, O-Ring, Lid, and Eye Nuts in the opposite order of
in which they were disassembled.
9. Lightly snug each nut in a criss-cross pattern first, then progressively tighten each
nut in a criss-cross pattern after they are all snug.

REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A 7


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

OPTIONAL ACCESSORIES
There are a few optional accessories available that will enhance filter performance thru
monitoring. Below are listed each accessory along with a description of their typical
application for the SSC Filters

Pressure Differential Monitoring


When operating the SSC Filters it necessary to monitor the pressure difference between the
inlet and outlet of the filter housing. As the cartridge filters become saturated with trapped
dirt particles and debris, the inlet pressure will rise and the outlet pressure will drop. This
difference in pressures across the filter is referred to as the filter pressure differential.

A filter pressure differential of approximately 15 psi indicates a fully saturated filter and is
ready for immediate replacement.

Differential Pressure Gauge


Depending on the application, and your setup, a single pressure differential gauge may be
all that is needed to monitor the filter’s performance status. These types of gauges only
indicate the pressure differential across the filter and not the inlet/outlet pressures.

Pure Aqua, Inc. carries a complete line of differential pressure gauges suited to your
specific requirements.
S P E C I F I C AT I O N S
Part # DP-030-025
DP Range 0 t 30 psi (.06 to 2 bar)
Maximum Static Pressure 350 psi (25 bar)
Accuracy ± 1% of FSR
Max Temperature 176 F ( 80 C)
Pressure Connections 1/4” FNPT

Differential Pressure Switch w/ Gauge


This differential pressure switch can be wired into the other control systems for status
and alarm monitoring, These switches feature an integrated differential pressure gauge
indicating a 0-30 psi differential scale.

S P E C I F I C AT I O N S
Part # DP-030-025 Switch Type SPDT/REED switch
DP Range 0 t 30 psi (.06 to 2 bar) Switch Set-point 15 psi (1 bar)
Maximum Static Pressure 350 psi (25 bar) Switch Operation N/O or N/C
Accuracy ± 1% of FSR Electrical Connection DIN
Max Temperature 176 F ( 80 C) Hysteresis ± 10% to 15%
Pressure Connections 1/4” FNPT 15 VA, 125 VAC / 200 VDC
Switch Rating
Housing Weather proof IP-65 100 VA, 230 VAC / 300VDC

REV. A
APRIL 2018

8 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS
Inlet/Outlet Pressure Gauge Set
For applications where the actual inlet and outlet pressures need to be know,
Pure Aqua, Inc. carries a complete line of 2.5” diameter, dual scale (PSI, Bar) pressure
gauges. These pressure gauges are constructed of a liquid filled 304 stainless steel casing
with 316 stainless steel wetter parts.

Pressure Glycerin Process


Part Number Dial Size (in) Mount Clamp
Rating (psi) Filled Connection
PG-100-P-316 0-100 2.5 Yes Back Yes 1/4" MNPT

PG-100-S-316 0-100 2.5 Yes Bottom No 1/4" MNPT

PG-150-P-316 0-150 2.5 Yes Back Yes 1/4” MNPT

PG-150-S-316 0-150 2.5 Yes Bottom No 1/4” MNPT

Drain Valves & Air Vent Valves


When performing a filter change on the SSC filters ( SSC-4 thru SSC-600) it is highly
recommended that the filter be drained of the unfiltered water trapped inside the housing
before removing the dirty filters. This will help prevent dirt and debris from passing into the
clean side of the filter housing.

SSC-4 and larger filters have 2 separate drain ports located near their base. The upper
most port is for draining the dirty half of the filter housing. The lower port is for draining
the clean side of the filter housing.

The top of the filter housings also provide a port for a vent valve. This vent allows the water
to drain much easier. Additionally, the vent aids in venting trapped air upon startup after a
filter change.

Pure Aqua, Inc. carries a complete line of high quality, 316 stainless steel ball valves sized
to match the vent and drain ports for all filter models.

S P E C I F I C AT I O N S 1/4” Ball Valve 1/2” Ball Valve


Part # 316BLV.25 316BLV.50
Connection Size 1/4” FNPT 1/2” FNPT
Style 2 Piece, Full Port Ball Valve 2 Piece, Full Port Ball Valve
Material 316 Stainless Steel 316 Stainless Steel
Pressure Rating ANSI 150 lbs. ANSI 150 lbs.

REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A 9


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

Spun Polypropylene Sediment Filter Cartridges


Pure Aqua’s spun polypropylene sediment filters are constructed of multi-layers for superior
depth filtration. The graded density construction captures particles throughout the entire cross
section of the cartridge and reduces surface binding.

These cartridges combine quality and cost effectiveness, providing excellent filtration value.
Available in a variety of micron ratings and sizes. Pure Aqua’s spun polypropylene sediment
filters meet NSF standards.

Specifications
Material Polypropylene
Length 9-7/8” - 40”
Maximum temperature 60°C / 140°F
Micron rating (nominal) 1 - 50
Cartridge packaging Shrink wrapped

2.5” Diameter Filter Cartridges


Part Number Micron Length Case qty
PA - 1 0 1 1 9-7/8” 50
PA - 2 0 1 1 20” 25
PA - 3 0 1 1 30” 25
PA - 4 0 1 1 40” 25
PA - 1 0 5 5 9-7/8” 50
PA - 2 0 5 5 20” 25
PA - 3 0 5 5 30” 25
PA - 4 0 5 5 40” 25
PA - 1 0 2 5 25 9-7/8” 50
PA - 2 0 2 5 25 20” 25
PA - 3 0 2 5 25 30” 25
PA - 4 0 2 5 25 40” 25

Additional micron ratings available upon request.

Applications Features & Benefits


• Reverse Osmosis Pre-Filtration • Multi-Layers Graded Density
• Food & Beverage Industry • Excellent Chemical Resistance
• Potable Water
• Low Cost
• Electronics
• High Dirt Holding Capacity
• Residential
• Wide Range Of Micron Ratings
• Fine Chemicals
• Plating • Wide Range Of Sizes
• Metal Finishing
• Car Wash

REV. A
APRIL 2018

10 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

Pleated Cellulose Sediment Filter Cartridges


Pure Aqua’s pleated cellulose sediment filters are constructed from a pleated cellulose
media that provides superior depth filtration. The pleated cellulose construction captures
particles throughout the entire cross section of the cartridge and reduces surface binding.

These cartridges combine quality and cost effectiveness, providing


excellent filtration value. Available in a variety of micron ratings and sizes.
Pure Aqua’s pleated cellulose sediment filters meet NSF standards.

2.5” Diameter Filter Cartridges


Part Number Micron Length Case qty

PP0.2x10 0.2 10 25

PP0.2x20 0.2 20 25

PP0.2x30 0.2 30 25

PP0.2x40 0.2 40 25

PA - 1 0 1 - P 1 9-7/8” 50

PA - 2 0 1 - P 1 20” 25

PA - 3 0 1 - P 1 30” 25

PA - 4 0 1 - P 1 40” 25

PA - 1 0 5 - P 5 9-7/8” 50

PA - 2 0 5 - P 5 20” 25
Specifications
Material (media) Pleated Cellulose PA - 3 0 5 - P 5 30” 25

Material (end caps) Vinyl Plastisol PA - 4 0 5 - P 5 40” 25


Material (core) Polypropylene
PA - 1 0 2 0 - P 20 9-7/8” 50
Length 9-7/8” - 40”
PA - 2 0 2 0 - P 20 20” 25
Maximum temperature 60°C / 140°F
Micron rating (nominal) 0.2 - 50 PA - 3 0 2 0 - P 20 30” 25

Cartridge packaging Shrink wrapped PA - 4 0 2 0 - P 20 40” 25

Additional micron ratings available upon request.

Applications Features & Benefits


• Reverse Osmosis Pre-Filtration • High Flow Rate
• Food & Beverage Industry • Low Pressure Drop
• Potable Water
• High Dirt Holding Capacity
• Electronics
• Wide Range Of Micron Ratings
• Residential
• Wide Range Of Lengths
• Fine Chemicals
• Washable & Reusable

REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A 11


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

String Wound Polypropylene Sediment Filter Cartridges


Pure Aqua’s string wound polypropylene sediment filters are manufactured from a durable
polypropylene cord that is wound around a rigid polypropylene core. They are an economical
solution to reduce fine sediment, including sand, silt, rust and scale particles.

These cartridges combine quality and cost effectiveness, providing excellent filtration
value. Available in a variety of sizes to meet your application needs.

Specifications
Material (media) Polypropylene fiber cord
Material (core) Polypropylene
Length 9-7/8” - 40”
Diameter 2-1/2” - 4-1/2”
Maximum temperature 74°C / 165°F
Micron rating (nominal) 1 - 50
Cartridge packaging Shrink wrapped

2.5” Diameter Filter Cartridges


Part Number Micron Length Case qty
PA - 1 0 1 - S 1 9-7/8” 50

PA - 2 0 1 - S 1 20” 25

PA - 3 0 1 - S 1 30” 25

PA - 4 0 1 - S 1 40” 25

PA - 1 0 5 - S 5 9-7/8” 50

PA - 2 0 5 - S 5 20” 25

PA - 3 0 5 - S 5 30” 25

PA - 4 0 5 - S 5 40” 25

PA - 1 0 2 5 - S 25 9-7/8” 50

PA - 2 0 2 5 - S 25 20” 25

PA - 3 0 2 5 - S 25 30” 25

PA - 4 0 2 5 - S 25 40” 25

Additional micron ratings available upon request.

Applications Features & Benefits


• Residential • High Flow Rate
• Commercial • Low Pressure Drop
• Fine Chemicals
• High Dirt Holding Capacity
• Metal Finishing
• Wide Range Of Micron Ratings
• Reverse Osmosis Pre-Filtration
• Wide Range Of Lengths
• Food & Beverage Industry
• Potable Water
• Electronics
REV. A
APRIL 2018

12 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

Carbon Block Cartridges & GAC Cartridges


Pure Aqua’s carbon block and granular activated carbon filter cartridges are manufactured
using high quality coconut shell carbon and GAC providing superior depth filtration. The
high quality coconut shell carbon and GAC removes unpleasant taste, odor and chlorine
that may be present in the water source.

These cartridges combine quality and cost effectiveness, providing excellent filtration
value. Available in a variety of sizes to meet your application needs.

Pure Aqua’s carbon block and granular activated carbon filter cartridges meet NSF
standards.

2.5” Diameter Cartridges


Part Number Carbon Type Length Case qty

CBC-10 Block 9-7/8” 12

CBC-20 Block 20” 6

G AC - 1 0 Granulated 9-7/8” 12

G AC - 2 0 Granulated 20” 6

Specifications
Material (media) Coconut Shell Carbon / GAC

Material (end caps) Polypropylene

Material (outside) Polypropylene

Material (inside) Polypropylene

Material (netting) Polypropylene

Material (gaskets) Neoprene

Maximum temperature 82°C/180°F

Cartridge packaging Shrink wrapped

Applications Features & Benefits


• Water Purification • High Flow Rate
• Vending Machines • Low Pressure Drop
• De-Chlorinating • High Filter Capacity
• Color Removal • High Chemical Absorptive Capability
• Drinking Water • Removes Unpleasant Taste
• Cooling Tower Treatment • Removes Unpleasant Odor
• Food & Beverage Industry • Removes Chlorine

REV. A
APRIL 2018

2 2 3 0 S out h Hur on D riv e , Sant a Ana, C A 9270 4 US A 13


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m
STAINLESS STEEL FILTER HOUSINGS

Ion Exchange Filter Elements (Softening Cartridges)

Pure Aqua’s softening cartridges are constructed using high quality ion exchange resin
media. Softening cartridges provide solutions for a variety of applications that need the
removal of calcium and magnesium contaminants. Softening cartridges are also effective in
removing iron from your water source.

Pure Aqua’s softening cartridges provide the best in water


purification and filtration.

2.5” Diameter Cartridges


Capacity
Part Number Length (grains)

S F T- 1 0 9-7/8” 1,260

S F T- 2 0 20” 2,520

Specifications
Material (body) Polyester

Material (cap) ABS

Material (pad) Polyester

Material (gasket) EPDM


38°C/100°F 32°C/90°F
Maximum temperature
(2.5” diameter) (4.5” diameter)
0.5 gpm/0.75 gpm 1.0 gpm/2.0 gpm
Operating flow rate
(2.5”x10”/2.5”x20”) (4.5”x10”/4.5”x20”)
Maximum pressure 125 psi
Cartridge packaging Shrink wrapped

Applications Features & Benefits


• Reverse Osmosis Post Filtration • Easy installation
• Car wash • High quality resin media
• Residential • High capacity
• Commercial • Fits standard and slim housings
• Industrial • Ultrasonic welding
• Durable construction
• FDA approve

REV. A
APRIL 2018

14 2 2 3 0 S out h Hur on D riv e, Sant a Ana, C A 9270 4 US A


P h o n e : + 1 - 71 4 - 4 3 2 - 9 9 9 6 , E m a i l : s a l e s @ p u r e a q u a . c o m , w w w . p u r e a q u a . c o m

You might also like