Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OTDR report

Job info
Job ID : Reason :
Contractor : NK Operator A : rams
Customer : Operator B :
Test date : 10/15/2020 (5:53:05 PM GMT+7:00) File : ITCTOMSC11.sor

Cable info
Fiber ID : Cable ID :
Location A : Location B :
Cable mfr. : Type :
Subset ID : Color ID :

Link measurements
Span loss : 0.872 dB Avg. splice loss : ---
Span length : 2.8594 km Max. splice loss : ---
Average loss : 0.305 dB/km Span ORL : <32.08 dB

OTDR trace

dB

25.00

20.001

15.00
2

10.00

5.00

0.00
500 1000 1500 2000 2500 3000 3500 4000 m

Signature : _________________________ Date : 10/19/2020


EXFO E. O. Engineering Inc. Page 1 / 2
OTDR report
Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Launch Level 0.000 0.000


Fiber Section (2.8594 km) 0.872 0.305 0.872
2 2.8594 Reflective Fault 0.000 41.1 0.872

Marker info
A : 0.0000 km, 11.087 dB B : 0.0000 km, 11.087 dB
a : 0.0000 km, 11.087 dB b : 0.0000 km, 11.087 dB
A to B distance : 0.0000 km, 0.000 dB A to B ORL : *****
3-pt. reflectance : ***** A to B LSA att. : -0.000 dB/km
4-pt. Ev. loss : 0.000 dB

Test and cable setup


Wavelength : 1310 nm (SM-9µm) Acq. time : 5s
Filename : ITCTOMSC11.sor Pulse width : 80 ns
Hardware : Helix factor : 0.00 %
Serial number : 0901001 Splice loss threshold : 0.100 dB
Software : N/A Reflectance threshold : -40.0 dB
Range : 4.1825 km End-of-fiber threshold : 10.000 dB
IOR : 1.468000
RBS : -80.00

Comments
NK

Signature : _________________________ Date : 10/19/2020


EXFO E. O. Engineering Inc. Page 2 / 2

You might also like