Buildings Department Practice Note For Mandatory Building and Window Inspection Schemes PNBI-7 Building Inspection Report
Buildings Department Practice Note For Mandatory Building and Window Inspection Schemes PNBI-7 Building Inspection Report
(a) Checklists for preparing an inspection report for different building elements
(Appendix A);
(c) Sample inspection report on common parts and external walls (Appendix
C).
3. The reference documents listed above are for general guidance and are not
meant to be exhaustive. The RI may include other items as necessary. The checklists
should be used for assuring that essential information is included in the inspection
report. The checklists are however NOT required to be submitted to the BA.
( YU Tak-cheung )
Building Authority
The requirements for inspection report are generally stipulated in the Buildings
Ordinance (BO), the Building (Inspection and Repair) Regulation and related regulations, the
Code of Practice for the Mandatory Building Inspection Scheme and the Mandatory Window
Inspection Scheme (the Code) and PNBIs. To ensure that all the essential information is
contained in the inspection report, the following checklists are provided for RI’s reference:
Checklist
Title
No.
The inspection report is prepared for the following MBIS notice served under section 30B of
the Buildings Ordinance (BO):
- OP date;
- Original and current usage;
- Number of storeys and units;
- Approved floor plans where available;
- Principal construction materials;
- Salient information of previous inspection and
repair;
- Name of Owners’ Corporation and management
company.
2. Reference documents
Checklist No. SC 1 P. 1 / 4
○ Yes □ No or Not Details
and Applicable refer to the
Reported report at
Page No.
3. Method Statement for Building Inspection
4. Inspection Result
Checklist No. SC 1 P. 2 / 4
○ Yes □ No or Not Details
and Applicable refer to the
Reported report at
Page No.
photos showing conditions of the building
inspected where rectification and repair works
are not required.
Checklist No. SC 1 P. 3 / 4
○ Yes □ No or Not Details
and Applicable refer to the
Reported report at
Page No.
- Has the method statement for rectification and ○ □ _____
repair works including details of the proposed
methods, materials, specifications and
precautionary measures been provided?
Checklist No. SC 1 P. 4 / 4
Checklist No. SC2
(4/2018)
Checklist No. SC 2 P. 1 / 1
Checklist No. SC3
○ Canopy
○ Balcony / Verandah
○ Fins
Checklist No. SC 3 P. 1 / 2
○ Features
○ A/C Platform
○ Drying Racks
○ Planter boxes
Checklist No. SC 3 P. 2 / 2
Checklist No. SC4
3. Mean of Escape
Checklist No. SC 4 P. 1 / 2
○ Yes and □ No or Not Details refer
Reported Applicable to the report
at Page No.
- Are there any defects in the integrity of the ○ □ _____
fireman’s lift lobby, such as any unauthorised
opening in the enclosure wall, insufficient
ventilation or obstruction to the fireman’s lift?
- Apart from the above defects, are there any other ○ □ _____
defects observed?
- Apart from the above defects, are there any other ○ □ _____
defects observed?
Brief Description :_________________
Checklist No. SC 4 P. 2 / 2
Checklist No. SC5
4. Defects observed
Checklist No. SC 5 P. 1 / 2
○ Yes □ No or Not Details refer
and Applicable to the report
Reported at Page No.
- Are there any discharge or untreated trade ○ □ _____
effluent, including hot water, into the drainage
system or to external parts of the building or
open area?
Examples:
a. Corrosion, leakage, deformation,
displacement, damage and blockage of drain
pipes and traps;
b. Corrosion, loosening or breaking of metal
brackets;
c. Damage or blockage of manhole/septic tank;
d. Broken of surface channel, gullies and catch
pits;
e. Missing drain pipes or grating at the top of
ventilation pipes; and
f. Deterioration or missing of mica flap in the
fresh air inlet.
Checklist No. SC 5 P. 2 / 2
Checklist No. SC6
Checklist for
Unauthorized Building Works(UBW)/Change in Use
○ Yes □ No or Not Details refer
and Applicable to the report
Reported at Page No.
1. UBW identified:
Examples:
Doors, gates or roller shutters obstructing
escape routes;
Unprotected openings at enclosure walls of
exit routes or compartment walls, floors and
ceilings;
Structures on refuge floors;
Door openings from cocklofts to exit
staircases in single-staircase buildings;
Alteration to escape routes, protected lobbies
or fire resisting construction resulting in
deficiencies in fire safety;
Structures on main or flat roofs resulting in
inadequate means of escape;
Structures on main or flat roofs resulting in
deficiency in fire resisting construction such
as inadequate fire separation between the
structures concerned and the main or flat roof
designated as a refuge floor;
Change in provision of fireman’s lift or lobby
of the fire fighting and rescue stairway; and
Removal of fire doors, fire shutters or other
fire resisting construction.
Examples:
Presence of many flat door openings, door
bells, electricity meters or drain pipe
connections.
Examples:
Storage of hazardous materials;
Exceeding the approved capacity in terms of
means of escape and/or imposed load of a
room or storey.
Checklist No. SC 6 P. 2 / 2
Checklist No. SC7
Checklist No. SC 7 P. 1 / 1
Checklist No. SC8
i. Screeding thickness
ii. Cover of the reinforcement
iii. Size of the reinforcement
i. Span
ii. Thickness of slab
4. RC Elements
Checklist No. SC 8 P. 1 / 3
○ Yes □ No or Details
and Not refer to the
Reported Applicable report at
Page No.
- Apart from the above defects, are there any ○ □ _____
other defects observed? (item no. and in
the Diagram 1)
Examples:
a. Defective tiles/rendering;
b. Cracks or spalling;
c. Delamination;
d. Exposed reinforcement;
e. Voids and honeycombing; and
f. Deformation or displacement.
5. Metal Elements
Examples:
a. Dilapidation;
b. Loose or defective fixing; and
c. Deformation or displacement.
Checklist No. SC 8 P. 2 / 3
○ Yes □ No or Details
and Not refer to the
Reported Applicable report at
Page No.
- Have the deviations caused the structure ○ □ _____
overloaded or seriously impaired the safety of
the structure?
8. Assessment
Checklist No. SC 8 P. 3 / 3
Checklist No. SC9
2. RC Elements
Examples:
a. Defective tiles/rendering;
b. Cracks and spalling;
c. Delamination;
d. Exposed reinforcement;
e. Voids and honeycombing; and
f. Deformation or displacement.
Examples:
a. Dilapidation;
b. Loose or defective fixing;
c. Deformation or displacement;
d. Cracked, loose, broken or missing glass
panels; and
e. Defective sealants.
Checklist No. SC 9 P. 1 / 3
○ Yes □ No or Not Details
and Applicable refer to the
Reported report at
Page No.
- Have the building works found deviated from ○ □ Not applicable _____
the building records constituted obvious
hazard or danger?
6. Assessment
Checklist No. SC 9 P. 2 / 3
Diagram 1: Inspection Items for Balcony (also applies to Verandah)
Ceiling of the Balcony/Verandah Drainage System Thickened finishes
Support of the Balcony/Verandah RC Parapet (internal surface) Glass balustrade
Surface of the Balcony/Verandah Metal Railing
(4/2018)
Checklist No. SC 9 P. 3 / 3
Appendix B
(PNBI-7)
Cover Page
MBIS Inspection Report for Projections
Statutory Notice No: UMB/50C199/1401-999/0055
1. Summary
1.2 *In my opinion the above premises has been rendered dangerous
or is liable to become dangerous, and a prescribed repair is
required to be carried out to render the building safe / in my
opinion the above premises is safe and no prescribed repair is
required.
2. Building Information
3. Reference Documents
(b) Plans and details of minor works carried out under the simplified
requirements:
I have used the following methods and carry out the following tests to
inspect the projections of the premises:
5. Inspection Results
I have personally carried out inspection for the projections of the above-
mentioned premises, including checking the structure and related
drainage pipe and outlet of the projections. Inspection Form is provided
in Section 9.1.
*I have found the following defects: (Please refer to Section 9.2 for the
photos and details)
Other Examples:
*The floor drain at the balcony was blocked.
*Spalling on the internal surface of parapet.
7. Assessment of Conditions
I have copied this report to the owner and explained the content of it to
the owner.
Building Address: Flat 8, 9/F, Block A, Square Tower, Wan Chai Report Page No.: 7
MBIS Notice No: Name of RI: Date of Inspection:
Inspection of Projections
Photo No.
Prescribed Other
Defects Repair
Required?
Corroded metal
Protective
At the balcony railings were Yes 003
barrier
observed
Drainage No defects or
At the balcony No 004
System deficiencies
UBWs:
Type Location Description Any obvious hazard Remarks
Photo No.
or danger ?
Owner was
The protective
informed and
barrier was altered
Protective recommended to
At the balcony from metal No 005
Barrier consider rectifying
balustrade to glass
and removing the
balustrade
UBWs
6/9
MBIS Inspection Report for Projections
Statutory Notice No: UMB/50C199/1401-999/0055
9.2 Annotated photos and marked up plans for building defects and deficiencies
Location Plan
Floor Plan
Floor Plan
Elevation
Elevation
7/9
MBIS Inspection Report for Projections
Statutory Notice No: UMB/50C199/1401-999/0055
Photos Descriptions
Photo 1
No defects or
deficiencies.
Photo
Photo 2
Photo
8/9
MBIS Inspection Report for Projections
Statutory Notice No: UMB/50C199/1401-999/0055
Photo 3
Corroded metal railings
were noted.
Photo
Photo 4
No defects or
deficiencies.
Photo
Photo 5
Photo
(4/2018)
9/9
Appendix C
(PNBI-7)
RI signature My Signature
Name of RI: Lau YIM
1. Summary
1.1 I carried out the prescribed inspection personally as required by the above
statutory notice for the common parts / external walls of the subject building
on 10 February 2017. *I also engaged representatives (particulars,
qualifications and experience at Annex A) to assist me in ascertaining the
extent of the defects.
1.2 In my opinion, *the above building has been rendered dangerous or is liable
to become dangerous, and a prescribed repair is required to be carried out to
render the building safe/the above building is safe and no prescribed repair
is required.
1.3 *There are unauthorised building works (UBWs) in the above building.
However, in my opinion, the UBWs do not constitute any obvious hazard or
danger. I have informed the IO/owner(s) and advised him/her/them to
consider removing the UBWs.
2. Building Information
3. Reference Documents
(b) Plans and details of minor works carried out under the simplified
requirements:
(c) Plans and documents submitted to the BA under section 39C of the BO:
(d) Fire Safety Directions (FSDn) served by the BD on the building owners:
2
*: Denotes possible items
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Documents Description
N/A N/A
I have inspected the various types of building elements by the following methods
and tests:
5. Inspection Results
6. Assessment
* CCTV survey has been conducted for the underground drainage. Damaged
underground drain pipes identified in the survey should be replaced. Please
refer to the CCTV survey report in Annex G.
* Investigation has been carried out for the CSC facing Tai Yuen street and
assessment has been conducted in accordance with sections 4.3.3 and 4.3.4 of the
CoP to ascertain the safety of the canopy . No remedial work is considered
necessary before the next cycle of inspection. Please refer to the investigation
report and structural assessment in accordance with the requirement of the CoP
in Annex H.
* The conditions of the CSC facing Tai Yuen Street require regular maintenance
for maintaining safety until the next cycle of inspection. The owners have been
advised on the need for regular maintenance of such CSC.
* The UBWs identified in Section 5 item (f) above do not constitute any obvious
hazard or danger. Nevertheless, the owners have been advised to remove such
UBWs.
I have copied this report to the IO/owners and explained the content of it to them.
7. Repair Proposal
The owners may also wish to take this opportunity to carry out other
improvement or upgrading works (which are outside the scope of the MBIS
notice) concurrently as detailed below:
6
*: Denotes possible items
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Annex A –
Particulars of RI’s Representative engaged
in Prescribed Inspection
(Relevant documents to be enclosed under this Annex as appropriate)
7
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Annex B –
Latest Set of Approved Floor Plans
(Relevant documents to be enclosed under this Annex as appropriate)
8
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Annex C –
Photos of Each Elevation
(Relevant photos to be enclosed under this Annex as appropriate)
9
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Annex D –
Summary Tables
10
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Building Address: Block A, Square Tower, Wan Chai Report Page No.:
MBIS Notice No. Name of Registered Inspector: Date of Inspection: 10.2.2017
UMB/5OC199/1401-999/0001 Lau YIM
Time: 10:00 to 17:00 Weather Condition: Sunny
Inspection of External Elements and Other Physical Elements
Follow-up
Location Actions
Required
Defect
Remarks
Common Parts
Element type
Type*
Photo No.
Elevation
Internal
Repair
Others
Floor
* Defect Types:
1 Loose or missing tiles and rendering 7 Displacement of cladding panels
2 Cracks 8 Cracked or loose cladding panels
3 Bulging, bowing, separation, delamination, etc. 9 Defective sealing joints
4 Stains 10 Corrosion of fixing anchors or metal frames
5 Deterioration 11 Defective components such as hinges, track,
6 Spalling guide rail and stopper
12 Others (please specify)
11
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Building Address: Block A, Square Tower, Wan Chai Report Page No.:
MBIS Notice No. Name of Registered Inspector: Date of Inspection: 10.2.2017
UMB/5OC199/1401-999/0001 Lau YIM
Time: 10:00 to 17:00 Weather Condition: Sunny
Inspection of Structural Elements
Follow-up Actions
Required
Defect
Location Element Remarks
Type*
Photo No.
Repair
Others
D1
(Open up at 2
locations (Section
3.4.2(A) of CoP
refers))
1/F Cantilevered S009 No defects or
beam & slab deficiencies
type canopy
(Concealed by
false ceiling.
Not less than 30%
of the concealed
area has been
removed (Section
3.4.2(B) of CoP
refers))
Flat A, 3/F Drying racks, 2, 3, 4 √ S010
planter box
and window
canopy
12
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
* Defect Types:
1 Dampness 6 Exposed reinforcement
2 Rust stains/Corrosion of reinforcement, structural 7 Voids and honeycombing
steel or bolts 8 Deformation or displacement
3 Cracks 9 Others (please specify)
4 Spalling
5 Delamination
13
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Building Address: Block A, Square Tower, Wan Chai Report Page No.:
MBIS Notice No. Name of Registered Inspector: Date of Inspection: 10.2.2017
UMB/5OC199/1401-999/0001 Lau YIM
Time: 10:00 to 17:00 Weather Condition: Sunny
Inspection of Fire Safety Elements
Follow-up Actions
Required
UBWs Repair/ Others
Type**/Un- Reinstatement
Defect
Location Element authorised Remarks
Type*
Photo No.
Change in
Use***
14
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Building Address: Block A, Square Tower, Wan Chai Report Page No.:
MBIS Notice No. Name of Registered Inspector: Date of Inspection: 10.2.2017
UMB/5OC199/1401-999/0001 Lau YIM
Time: 10:00 to 17:00 Weather Condition: Sunny
Inspection of Drainage System
Follow-up
Actions
Required
Defect UBW
Location Element Remarks
Photo No.
Type* Type**
Repair
Others
DI
15
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Form 6 – UBW
Building Address: Block A, Square Tower, Wan Chai Report Page No.:
MBIS Notice No. Name of Registered Inspector: Date of Inspection: 10.2.2017
UMB/5OC199/1401-999/0001 Lau YIM
Time: 10:00 to 17:00 Weather Condition: Sunny
UBW
16
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Annex E –
Annotated Photo Record
17
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
Photo E002
No defects or
deficiencies
Photo
* * *
* * *
* * *
* * *
18
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
* * *
* * *
* * *
* * *
Photo No. Descriptions
Photo E009
No defects or
deficiencies
Photo
Photo E010
Bulging of tiles at 2/F
Photo
19
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
* * *
* * *
* * *
* * *
Photo E017
No defects or
deficiencies
Photo
20
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
Photo E019
No defects or
deficiencies
Photo
* * *
* * *
Photo E021
No defects or
deficiencies
Photo
21
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
* * *
* * *
* * *
* * *
Photo S004
No defects or
deficiencies
Photo
22
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
Photo S006
No defects or
deficiencies
Photo
Photo S007
Spalling and
reinforcement
corrosion (as shown in
the red circles) were
Photo observed at R/F
staircase
23
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
Photo S009
No defects or
deficiencies
Photo
Photo S010
Corroded drying racks
and cracks and
spalling at planter box
and window canopy at
Photo Flat A, 3/F
24
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
Photo F002
Door with inadequate
FRC at Flat A, 1/F
Photo
Photo F003
No defects or
deficiencies
Photo
25
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
Photo F005
No defects or
deficiencies
Photo
Photo F006
Wrong swing
direction of door at
5/F staircase
Photo
26
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
27
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Defective surface
Photo water pipes
Photo D002
Defective surface
water pipes
Photo
Photo D003
Defective surface
water pipes
Suspected
Photo unauthorised waste
pipe connected to
surface water system
at 2/F
28
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
Photo D005
Defective surface
water pipes
Photo
Photo D006
Defective surface
water pipes
Photo
29
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
Photo D008
No defects or
deficiencies
Photo
30
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo U002
Flat roof structure at
Flat B, 1/F
Photo
Photo U003
Dilapidated drying
rack at Flat A, 4/F
Photo
31
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Photo
Photo U005
Prefabricated structure
at R/F
Photo
32
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Annex F –
Mark-up Plans
33
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Mark-up Plans
North Elevation
South Elevation
34
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Mark-up Plans
G/F Plan
1/F Plan
2/F Plan
35
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Mark-up Plans
3/F Plan
4/F Plan
5/F Plan
36
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Mark-up Plans
Roof Plan
37
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Annex G –
CCTV Survey Report for Underground
Drainage
(Relevant documents to be enclosed under this Annex as appropriate)
38
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Annex H –
Investigation Report and Structural
Assessment for CSC facing Tai Yuen Street
(Relevant documents to be enclosed under this Annex as appropriate)
39
MBIS Inspection Report
Statutory Notice No: UMB/5OC199/1401-999/0001
Annex I –
Particulars of RI’s Representatives in
Supervision Team for Prescribed Repair
(Relevant documents to be enclosed under this Annex as appropriate)
40