SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010

METROLOGOS ESPECIALIZADOS E INGENIEROS ELÉCTRICOS S. DE R.L. DE C.V.


Sur 105a #702 Colonia Sector Popular Iztapalapa
Ciudad de México 09060
Emmanuelle David Mora Muñiz Phone: 76914255
Web: www.metrologosmeie.com

PROFICIENCY TESTING PROVIDER

Valid To: June 30, 2022 Certificate Number: 4853.01

In recognition of the successful completion of the A2LA evaluation process, this proficiency testing provider has been
found to meet the ISO/IEC 17043:2010, “Conformity assessment-General Requirements for Proficiency testing.”
Therefore, in recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
provider to offer the following proficiency testing programs*:

DISCIPLINE SUB-DISCIPLINE PROPERTIES MEASURED


TYPE OF TEST
RANGE OF MEASUREMENT

FLUID Volume of water: (flow) Test of cold ISO 4064: 2016; NTC 1063-1:1995;
drinking water meters DN15 by the NTC 1063-3:1994; NTC 1063-1:2007;
collection method. NTC 1063-3: 2007; NTC-ISO 4064-1:
2016; NOM-012-SCFI-1994; NMX-
CH-1/3-1993-SCFI

Volume: Calibration of vertical and API MPMS 2.2 A; API MPMS 2.2 B;
horizontal cylindrical tanks (Large API MPMS 2.2 D; API MPMS 2.22 E;
Volumes) API STD 252; ISO 12917:2012

Flow: Calibration of mass flow ISO 4064:2005; NTC 1063-3-2007;


meters and volumetric flow NOM-012-SCFI-1994; NTE INEN ISO
4064; API MPMS CAP 12.2.3; API
2555; API MPMS 11.2.3; API MPMS
11.4.1; ISO 4269; NTC 2728:2005
Annex B; OIML R-137-1and 2:2012;
PTB 29:2003; ISO 9951:1993

Calibration of CH4 and CO gas Measurement range: 0 ppm, 1000 ppm


detectors and 10 000 ppm for CH4;
Measurement rage: 0 ppm, 15 ppm, 50
ppm for CO; Standard: QU-012:2008
Digital Edition 1

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 1 of 10


DISCIPLINE SUB-DISCIPLINE PROPERTIES MEASURED
TYPE OF TEST
RANGE OF MEASUREMENT

DIMENSIONAL 1D – Portable gauging and hand Measurement range: 0 mm to 500 mm;


tools Length – outdoor micrometer resolution of 0.001 mm
calibration

MECHANICAL Calibration of pressure manometers Measurement range: (0 psi to 10000


psi); DKD-R 6-1:2014; NTC 2263;
COVENIN 2333-93; NMX- CH-003-
1993-FCFI

ELECTRICAL – DC/LOW Measurement procedures for energy NTC 4856:2015


FREQUENCY meters: calibration by the pulse
comparison method, clause 4.4.2.2 of
the standard: NTC 4856: 2015;
energy verification method
(Verification test of the constant by
the energy metering method)
numeral 4.4.3.2 of standard: NTC
4856: 2015

Calibration of transformers of Numerals 7.2.6.301, 7.3.5.301 of the


medium voltage and electric current Standard: NTC 2207:2017 (IEC 61869-
3:2011), numeral 7.10 of the standard:
NTC 5787:2010 (IEEE C57.13:2008)
(for voltage transformers); numerals
7.2.6.201, 7.3.5.201 of the standard:
NTC 2205:2013 (IEC 61869-2:2012);
numeral 6.11 of the standard NTC
5787:2010 (IEEE C57.13:2008) (for
current of current transformers); IEC
61869-2; IEC 61869-3

Calibration of test equipment for Colombian Technical Standard: NTC


energy meters (EPM) 2423: 2017

Calibration of digital multimeters Voltage in c.c. current in c.c., resistance


(from 4 ½ to 5 ½ digits) Ω, voltage in c.a., current in c.a.

THERMODYNAMICS Calibration of direct reading Measurement range: 0 °C to 600 °C


thermometers (TLD)

Calibration for thermohygrometers Measurement range: 0 °C to 60 °C for


temperature;
Measurement range: 0 % a 60 % for
relative humidity

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 2 of 10


PROGRAM SUB-DISCIPLINE PROPERTIES MEASURED
TYPE OF TEST
RANGE OF MEASUREMENT

VOLUME TESTING Test of determination of Colombian Technical Standard: NTC


volumetric expansion (permanent 5171: 2013; CGA-C1; NTC 522-1:
volumetric expansion) and 2011; NTC 2699: 2009; NTC 4828:
hydrostatic pressure and rupture 2001; NOM-008-SESH/SCFI-2010;
test NOM-009-SESH-2011

ELECTRICAL TESTING/ENERGY Protection against access to living Subsection 8 of the standard: NMX-J-
EFFICIENCY parts 521/1-ANCE-2012, Subsection 8 of
the standard: IEC 60335-1:2010;
Subsection 9.1 of the standard: NMX-
J-524/1-ANCE-2013; Subsection 9 of
the standard: IEC 60745-1 Edition 4;
Subsection 6.3.2 of the standard:
NOM-022-ENER / SCFI-2014;
numeral 8 of the standard: NTC 2252;
numeral of the standard; 8 (8.1.1 to
8.1.5) of the standard NTC 2183;
standard: NTE INEN-IEC 60335-1;
Numeral 10.1 of the standard: NTC
1337:2004; Numeral 10.102 of the
standard: UNE EN 60669-2-1: 2005;
Numeral 10.103 of the standard:
UNE EN 60669-2-1:2005; Numeral
10.1; 10.5 and 10.6 of the standard:
NTC 1650: 2004; NMX-J-515-
ANCE-2014; NTC 2386 subsection 8;
subsection 5.1.2 of the standard
NOM-019-SCFI-1998

ELECTRICAL TEST/ENERGY Input power and current Subsection 10 of the standard: NMX-
EFFICIENCY/MECHANICAL J-521/1-ANCE-2012; Subsection 10
METAL of the standard: IEC 60335-1:2010;
Subsection 6.3.4 of the standard:
NOM-022-ENER / SCFI-2014; NTC
2183; NTE INEN-IEC 60335-1;
subsection 14 of the standard NOM-
019-SCFI-1998

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 3 of 10


PROGRAM SUB-DISCIPLINE PROPERTIES MEASURED
TYPE OF TEST
RANGE OF MEASUREMENT

ELECTRICAL TESTING/ENERGY Heating Subsection 11 of the standard: NMX-


EFFICIENCY J-521/1-ANCE-2012; Subsection 11
of the standard: IEC 60335-1:2010;
Subsection 6.3.5 of the standard:
NOM-022-ENER/SCFI-2014;
subsection 11 of the standard: NTC
2252; Subsection 11 of standard NTC
2183; NTE INEN-IEC 60335-1;
numerals: 7.3.1.5, 7.3.1.2.1; 7.3.1.5;
7.3.1.1 and 7.3.1.2.1 of the standard:
NTC 2832; paragraphs 5.2 and 8 of
the standard: NOM-001-SCFI-1993;
subsections 4.2 y 5.2 of the standard
NOM-016-SCFI-1993; subsection 15
of the standard: NOM-019-SCFI-
1998; subsection 17 of the standard:
NTC 1337:2004; Subsection 17 of
standard IEC 60669-1, Subsection 6.5
and 8.5 of Standard: NOM-064-SCFI-
2000

ELECTRICAL TESTING Dielectric leakage current and Subsection 13 and 16 of the standard:
/ENERGY EFFICIENCY resistance NMX-J-521/1-ANCE-2012;
subsection 13 and 16 of the standard:
IEC 60335-1:2010; Sections 6.3.6.6
and 6.3.8.2 of the standard: NOM-
022-ENER/SCFI-2014; Sections 13
and 15 of the standard: NMX-J-
524/1-ANCE-2013; Sections 13 and
15 of the standard: IEC 60745-1
Edition 4; Sections 13 and 16 of the
standard: NTC 2252; Subsections 13
and 16 of the standard: NTC 2183;
NTE INEN-IEC 60335-1;
Subsections 13 and 16 of the
standard: NTC 2386; numerals 13 and
16 of the standard: NTC 2252;
Subsection 5.7 of the Standard NOM-
016-SCFI-1993; Subsection 6.2.3 of
the standard NMX-J-508-ANCE-
2010; Subsection 9.13 of the Standard
NMX-J-024-ANCE-2005

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 4 of 10


PROGRAM SUB-DISCIPLINE PROPERTIES MEASURED
TYPE OF TEST
RANGE OF MEASUREMENT

ELECTRICAL TESTING Protection against overloading of Paragraph 17 of the standard: NMX-


transformers and associated J-521/1-ANCE-2012; Subsection 17
circuits of the standard: IEC 60335-1:2010;
Subsection 16 of the standard: NMX-
J-524/1-ANCE-2013; Subsection 11
of the standard NOM-001-SCFI-1998

Subsection 6.3.8.3 of the standard:


ENERGY TESTING/EFFICIENCY Dielectric strength (insulation NOM-022-ENER/SCFI-2014;
requirements) subsection 6.4 of the standard: NMX-
J-515-ANCE-2008; Section 11.2 (b)
of the standard: NOM-001-SCFI-
1993, Clause 5.5 of the standard:
NOM-016-SCFI-1993, Clause 17 of
the standard: NOM-019-SCFI-1998;
Subsection 8.4.7 of the standard:
NOM-010-SEHS-2012; ASTM-120-
14A; ASTM D-1049: 98; ASTM
D1050-05; ASTM D104814; ASTM-
F4962014; NTC-2830; ASTM-
F2321-14; ANSI / SAIA- A92.2;
ASTM-F479-06; IEEE 978-1984;
Numeral 6.2 of the standard: NTC
5786: 2010; UL2556:2015;
Subsection 6.2.2 of the standard
NMX-J-508-ANCE-2010; Subsection
9.5 of the standard NMX-J-024-
ANCE-2005

TEST/ENERGY Insulation resistance Subsection 11.2 (a) of the standard:


EFFICIENCY/MECHANICAL NOM-001-SCFI-1993; subsection 5.6
METAL of the standard: NOM-016-SCFI-
1993; Subsection 8.4.8 of the
standard: NOM-010-SEHS-2012; IEC
60065; ANSI / UL60065; Seventh
edition; UL 6500; ANSI / UL 60065
CAN / CSA-C22.2 No. 60065-2003
Amendment 1: 2006; Section
6.1.10.2.2 of the standard IFT 004-
2016; Standard NMX-J-294-ANCE-
2008

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 5 of 10


PROGRAM SUB-DISCIPLINE PROPERTIES MEASURED
TYPE OF TEST
RANGE OF MEASUREMENT

ENERGY TESTING/EFFICIENCY/ Determination of the diameter and Subsection 15 of the standard: NOM-
MECHANICAL METAL cross-sectional area of the electric 001-SCFI-1993; Sub-paragraph: 25.8
conductors of the standard: NMX J-521/1-
ANCE-2012; Paragraph 25.8 of the
standard: IEC 60335-1:2010;
Subsection 24.5 of the standard:
NMX-J-524/1-ANCE-2013;
subsection 24.5 of the standard: IEC
60745-1, Edition 4; Standard: NMX-
J-066-ANCE-2017 and IEC62067;
Subsection 8.4.2 of the standard:
NOM-010-SEHS-2012; numeral 7 of
the standard: NTC 5891; standard:
IEC 62552:2007; ASTM B263

ELECTRICAL TESTING Determination of electrical Standard: NMX-J-212-ANCE-2017;


resistance to direct current IEC 60228

ELECTRICAL TEST Determination of the cross- Included in the standard: NMX-J-


sectional area of electric 129-ANCE-2007; NTC 3203: 2006;
conductors according to their mass UL 1581: 2014; subsections 3.1, 3.2
and 3.3 of the standard: UL 2556:
2015; NTE INEN 2 345:2004; No.
013-2016- PRODUCE; subsection 3.2
of the standard: NTC 5786: 2010

ENERGY TESTING/EFFICIENCY Energy efficiency and temperature Subsection 9 of the standard: NOM-
test to pull down 015-ENER-2012; Subsection 5 of the
standard: AHAM STANDARD HRF-
1-2008; Subsection 15 of the
standard: ISO 15502 (E) Edition 1;
paragraph 9 of the Ecuadorian
technical regulation: RTE INEN 009
(1R); subsections 6.1 and 6.2 of the
standard: NOM-022-ENER / SCFI-
2014; IEC 62552-1-2 3: 2015; NTC
5891 2011-12-14 number 15

ENERGY EFFICIENCY TEST Energy efficiency of washing Subsection 9 of the standard: NOM-
machines 005-ENER-2012 (NMX-J-585-
ANCE-2014; INEN-2259-2013);
UNE EN 60456: 2014; IEC 60456:
2010; NMX-J-528-ANCE-2011; NTE
INEN 2659: 2016; PRTE INEN 077

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 6 of 10


PROGRAM SUB-DISCIPLINE PROPERTIES MEASURED
TYPE OF TEST
RANGE OF MEASUREMENT

ELECTRIC Security procedures for Measurement of the resistance ohmic of


transformers the winding, included in the Colombian
technical standard: NTC 375 (approved
2017-11-15), subsection 2.1.1, subsection
5 of the standard: IEEE Std C57.12.90-
2015, subsection 11.2 of the standard: IEC
60076- 1-2011, paragraphs 4.3.2 and 4.3.3
of the standard: NMX-J-169-ANCE-2015;
NMX-J-351-2-ANCE-2016;
Transformation ratio, included in the
Colombian technical standard: NTC 471
(Approved 2017-05-17), subsection 7 of
the standard: IEEE Std. C57.12.90-2015;
subsection 11.3 of the standard: IEC
60076-1-2011, subsection 6.2.2 of the
standard: NMX-J-169-ANCE-2015, NMX-
J-351-2-ANCE-2016; Lost in vacuum and
current of excitation, Colombian Technical
Standard: NTC 1031 (First edition),
subsection 8 of the standard: IEEE Std.
C57.12.90-2015; subsection 11.5 of the
standard: IEC 60076-1-2011, subsections
7, 7.1, 7.2, 7.2.1.2 of the standard: NMX-J-
169-ANCE-2015, NMX-J-351-2-ANCE-
2016; Measurement of impedance and
short circuit losses due to load Colombian
Technical Standard: NTC 1031 (first
update), subsection 9 of the standard: IEEE
Std C57.12.90-2015; subsection 11.4 of the
standard: IEC 60076-1-2011, subsection 4
of the standard NTC-1005, Section 8, 8.1,
8.2, 8.3, 8.4 of the standard: NMX-J-169-
ANCE-2015, NMX-J-351-2-ANCE-2016;
Measurement of insulation resistance,
Section 9.9 of the standard: NMX-J-169-
ANCE-2015, NMX-J-351-2-ANCE-2016;
Voltage applied and Induced, sections 9.5
and 9.6 of the standard: NMX-J-169-
ANCE-2015, NMX-J-351-2-ANCE-2016;
Polarity, phasor diagram, phase sequence,
section 5.1.1 of the standard: NMX-J-169-
ANCE-2015; Air tightness, section 11 of
the standard: NMX-J-169-ANCE-2015;
Measurement of temperature rise
(measurement of heating) of transformer
windings, sections 10, 10.2, 10.3, 10.3.1,
10.3.5 of standard NMX-J-169-ANCE-
2015, sections 10.4.2, 10.4.3, 10.4.4 of
standard NMX-J-169-ANCE-2004,
Standard NTC-316

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 7 of 10


PROGRAM SUB-DISCIPLINE PROPERTIES MEASURED
TYPE OF TEST
RANGE OF MEASUREMENT

ELECTRICAL/CHEMICAL Determination of the dielectric Subsection 6.19 of the standard: MX-


TESTING rupture by flat electrodes and semi- J-123-ANCE-2008; Subsection 6.19
spherical of the standard: NMX J-123-ANCE-
2005; ASTM D877 (reclaimed 2007)
and ASTM D877/D877M-13;
COVENIN 1403

TEST/ELECTRICITY – Determination of the power factor NMX-J-123-ANCE-2008 Section


ELECTRONIC 6.18; ASTM D924-15; COVENIN
1182

TEST/CHEMISTRY Determination of neutralization NMX-J-123-ANCE-2008 Section


number 6.16; ASTM D974-14

TEST/CHEMISTRY Content of polychlorinated NMX-J-123-ANCE-2008 Section


biphenyls (BPC'S) 6.17; ASTM D4059-00; standard US
EPA 8082 A (2007); NOM-133-
SEMARNAT-2015; IEC CEI/IEC
61619:1997; ASTM D923; EPA
525.3

TEST/CHEMISTRY Determination of kinetic viscosity NMX-J-123-ANCE-2008 Section 6.8;


at 40 °C ASTM D445-06; ASTM D445:17a;
EN-ISO 12937:2000

TEST/CHEMISTRY Determination of relative density NMX-J-123-ANCE-2008 Section 6.3;


(specific gravity or API gravity) ASTM D1298-12b; ASTM D 1298-
99

TEST/CHEMISTRY Determination of water content by NMX-J-123-ANCE-2008 Section


method Karl Fischer 6.13; ASTM D1533-12; ASTM E
1064/2012; ASTM E203-16

TEST/CHEMISTRY/INSPECTION Sampling in waters, which NMX-AA-003-1980; NMX-AA-3-


(SAMPLING) includes sampling of wastewater 1980; NMX-AA-014-1980; NOM-
and sampling of receiving bodies 001-SEMARNAT-1996; NOM-002-
(DQO and DBO) SEMARNAT-1996 and NOM-003-
SEMARNAT-1997; NTC ISO 5667-
10; SM 5210B; SM 4500-OC; SM
4500-OD; SM 5220C; ASTM D888-
12 Method C; ASTM D-1252-06
method B

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 8 of 10


PROGRAM SUB-DISCIPLINE PROPERTIES MEASURED
TYPE OF TEST
RANGE OF MEASUREMENT

TEST/CHEMISTRY Direct and physicochemical DQO, DBO, SOLIDS; NOM-001-


measurements in wastewater (S SEMARNAT-1996; NOM-002-
standard methods for the SEMARNAT-1996 y NOM-003-
examination of water and SEMARNAT-1997; SM 5210B; SM
wastewater) 4500-OC; SM 4500-OD; SM 5220C;
ASTM D888-12 method C; ASTMD-
1252-06 method B

TEST/CHEMISTRY Standard test method for ASTM D86-11a; ASTM D86:2016a;


distillation of petroleum products ASTM-D86:17
at atmospheric pressure

TEST/CHEMISTRY Standard test method for flash Procedures A, B, C, of the standard


point by closed cup Penskyn – ASTM D-93-08; Procedures A, B, C
Martens of the standard ASTM D-93-10a;
ASTM D93-16a

TEXTILE TESTS Textile physical measurement Determination of mass per unit area
procedures (weight) of fabric (determination of
tissue mass per unit length and area)
included in the Colombian technical
standard: NTC 230; Columbia
technical standard NTC 380; Standard
NMX-A-3801-INNTEX-2012;
ASTM D3776; BS 2471; ISO 3801;
JIS L 1096; DIN 53854

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 9 of 10


PROGRAM FOR SUB-DISCIPLINE PROPERTIES MEASURED TYPE
INSPECTORS OF TEST RANGE OF
MEASUREMENT

INSPECTION** Room volume measurement and Standard: NTC 2505; NTC 3631;
inspection observations, selected Standard: NOM-002-SECRE-2010;
(Inspections of installation of quantitative measurements and NOM-010-SCRE-2002 and Technical
natural gas and electrical for related qualitative inspection Regulation Resolution 4 1385 of
residential and commercial observations December 07 of 2017; Technical
buildings, gas exploration Regulation resolution 9 0902 of 2013.
facilities, and service stations) Resolution no. 90708 (August 30, 2013)
and Amending Resolutions 90907
(October 25, 2013), 90795 (July 25,
2014), 40492 (April 24, 2015),
Technical Regulation of Electrical
Installations (RETIE in Spanish):
Resolutions 90708 (August 30, 2013),
90907, 90795; Technical Regulation
Resolution 4 1385 of 2017; D.S.66
(External Resolution No. 1250); D.S.222

INSPECTION** Selected quantitative NTC 4231; NTC 4984; NTC 4983; NTC
measurements and related 5375; NTC 5365; NMX-AA-13-1976;
(Exhaust emissions from vehicles qualitative inspection observations NTE INEN 2202: 2013; ISO 8178-10:
using diesel fuel or gas) 2001; ISO 11614: 1999; SAE J 1667:
1996; Standards: NOM-045-
SEMARNAT-2006; NOM-045-
SEMARNAT-2017; NOM-167-
SEMARNAT-2017; NOM-068-SCT-2-
2014 and Resolution 910 of the Ministry
of environment and housing and
territorial development; NOM-047-
SEMARNAT-2014; NOM-050-
SEMARNAT-1993; NOM-041-
SEMARNAT-2015; NOM-042-
SEMARNAT-2003

* Assigned values for all property values are reference values that are metrologically traceable, where possible,
to the International System of Units (SI) or other reference standards.

** Expected results for inspection observations are determined by the subcontractor.

(A2LA Cert. No. 4853.01) Revised 10/24/2019 Page 10 of 10


Accredited Proficiency Testing Provider
A2LA has accredited

METROLOGOS ESPECIALIZADOS E INGENIEROS


ELÉCTRICOS MEIE S. DE R.L. DE C.V.
Ciudad de México, MEXICO
This accreditation covers the specific proficiency testing schemes listed on the agreed upon Scope of Accreditation.
This provider is accredited in accordance with the recognized International Standard ISO/IEC 17043: 2010
Conformity assessment - General requirements for proficiency testing. This accreditation demonstrates technical
competence for a defined scope and the operation of a quality management system.

Presented this 1st day of June 2018.

_______________________
Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4853.01
Valid to June 30, 2022
Revised on October 24, 2019

For the proficiency testing schemes to which this accreditation applies, please refer to the provider’s Scope of Accreditation.

You might also like