Foundation Plan (Truss Type)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

8 8 7 6 5 4 3 2 1

A B C D E F G H I
F 48000
6000 6000 6000 6000 6000 6000 6000 6000

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
3 4
S.2 S.2
1000 1000 1000 1000

2000

2000

2000

2000

2000

2000

2000
1000

1000
1

1000

1000
2000

2000

2000

2000

2000

2000

2000
P2 P2
300 x 300mm 300 x 300mm

2000 x 2000 x 300 mm 2000 x 2000 x 300 mm


P1 P1 P1 P1 P1 P1 P1
500 x 500mm 500 x 500mm 500 x 500mm 500 x 500mm 500 x 500mm 500 x 500mm 500 x 500mm

6000
2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm

E
1000 1000 1000 1000

1000

1000
2

1000

1000
P3 P3
400 x 500mm 400 x 500mm

6000 2000 x 2000 x 300 mm 2000 x 2000 x 300 mm


24000

1000 1000 1000 1000

1000

1000
3
1000

1000
D

P1 P1
500 x 500mm 500 x 500mm

2000 x 2000 x 300 mm 2000 x 2000 x 300 mm


6000

1000 1000 1000 1000


1000

1000
4
1000

1000
2
P3 S.2 P3
400 x 500mm 400 x 500mm

2000 x 2000 x 300 mm 2000 x 2000 x 300 mm


C
6000

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

1000 1000 1000 1000


2000

2000

2000

2000

2000

2000

2000
1000

1000
5 48000
1000

1000
2000

2000

2000

2000

2000

2000

2000
P2 P2
300 x 300mm 300 x 300mm

2000 x 2000 x 300 mm 2000 x 2000 x 300 mm


P1 P1 P1 P1 P1 P1 P1
500 x 500mm 500 x 500mm 500 x 500mm 500 x 500mm 500 x 500mm 500 x 500mm 500 x 500mm

2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm 2000 x 4000 x 300mm

1 STANDARD WAREHOUSE FOUNDATION PLAN


1 : 100 M

3000

1500
4000
16@300 BOT BARS EW. 2000

16@300 BOT BARS EW.


VERIFY

A 1500
1500
16mm dia. @ 200 mm O.C.
2000

2000
300

16 mm dia. @ 300 mm O.C.

2 TYPICAL SECTION 3 2000 x 2000 x 300 mm 4 2000 x 4000 x 300 mm


1500x1500x300
1 : 50 M 1 : 50 M 1 : 50 M
1500x3000x300

DESIGN AND BUILD: RA 9266 SECTION 33 CG - A&E DIVISION CG - R&D CG - SDD CG - EMDD - MECHANICAL CG - EMDD - FIRE PROTECTION PROJECT: OWNER: SHEET CONTENTS: APPROVED BY: SHEET NO:
DRAWING AND SPECIFICATIONS AND OTHER OPERATION GROUP
CONTRACT DOCUMENTS DULY SIGNED , STAMPED OR ROLAND JAMES B. ARIMADO - - -
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND THE DOCUMENTS OF
THE ARCHITECT, WHETHER THE OBJECT FOR WHICH
R&D HEAD SDD HEAD DESIGN MANAGER DESIGN MANAGER
STANDARD
THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE JEREMY G. ACOSTA
CG - EMDD CG - EMDD - ELECTRICAL CG - EMDD - PLUMBING
- FOUNDATION PLAN CONSTRUCTION MANAGEMENT S.2
UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO
MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE A&E HEAD WAREHOUSE
REPETITION OF AND FOR OTHER PROJECTS OR
DATE:
LIBERATO Q. GONZAGA II - - -
BUILDINGS, WHETHER EXECUTED PARTLY OR IN REVISED: RELEASED:
WHOLE, WITHOUT THE WRITTEN CONSENT OF
DESIGN MANAGER EMDD HEAD DESIGN MANAGER DESIGN MANAGER
ARCHITECT OR AUTHOR OF SAID DOCUMENTS. SCALE: AS SHOWN
© 2015 TECHNICAL SUPPORT DIVISION TEMPLATE

You might also like