SITRANS P measuring instruments for pressure

Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series

■ Overview
2

SITRANS P pressure transmitters, DS III series, are digital pres-


sure transmitters featuring extensive user-friendliness and high ■ Application
accuracy. Parameterization is performed using input keys or by The pressure transmitters of the DS III series, can be used in in-
means of HART communication. dustrial areas with extreme chemical and mechanical loads.
Extensive functionality enables the pressure transmitter to be Electromagnetic compatibility in the range 10 kHz to 1 GHz
precisely adapted to the plant’s requirements. Operation is very makes the DS III pressure transmitters suitable for locations with
simple in spite of the numerous setting options. high electromagnetic emissions.
Transmitters with type of protection "Intrinsic safety" and "Explo- Pressure transmitters with type of protection "Intrinsic safety" and
sion-proof" may be installed within potentially explosive atmos- "Explosion-proof" may be installed within potentially explosive at-
pheres (zone 1) or in zone 0. The transmitters are provided with mospheres (zone 1) or in zone 0. The pressure transmitters are
an EC type examination certificate and comply with the corres- provided with an EC type examination certificate and comply
ponding harmonized European standards (ATEX). with the corresponding harmonized European standards
(ATEX).
The transmitters can be equipped with various designs of re-
mote seals for special applications such as the measurement of Pressure transmitters with the type of protection "Intrinsic safety"
highly viscous substances. for use in zone 0 may be operated with power supply units of ca-
tegory "ia" and "ib".
Various versions of the DS III pressure transmitters are available
for measuring: The transmitters can be equipped with various designs of re-
mote seals for special applications such as the measurement of
• Pressure highly viscous substances.
• Absolute pressure
The pressure transmitters can be programmed locally using
• For differential pressure transmitters three input keys or externally through HART communication.
• Level
Pressure transmitters for pressure
• Volume
Measured variable: Pressure of aggressive and non-aggressive
• Volume flow
gases, vapors and liquids.
• Mass flow
Nominal measuring ranges: 1 ... 400 bar (14.5 ... 5802 psi)
■ Benefits Pressure transmitters for absolute pressure
• High quality and long life Measured variable: Absolute pressure of aggressive and non-
• High reliability even under extreme chemical and mechanical aggressive gases, vapors and liquids.
loads Nominal measuring ranges: 250 mbar ... 100 bar
• Extensive diagnosis and simulation functions (3.63 ... 1450 psi)
• Separate replacement of measuring cell and electronics wit- There are two series:
hout recalibration
• Pressure series
• Minimum conformity error
• Differential pressure series
• Small long-term drift
• Wetted parts made of high-grade materials (e.g. stainless Pressure transmitters for differential pressure and flow
steel, Hastelloy, gold, Monel, tantalum) Measured variables:
• Measuring range 1 mbar ... 400 bar • Differential pressure
• High measuring accuracy • Small positive or negative pressure
• Parameterization using input keys and HART communication

Siemens FI 01· 2005 2/23


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series
• Flow q ~ √∆p (together with a primary differential pressure de- The electrical connections for the power supply and screen are
2 vice)
Nominal measuring ranges: 20 mbar ... 30 bar (0.29 ... 435 psi)
accessible by unscrewing the rear cover. The bottom part of the
housing contains the measuring cell with process connection
(1). The measuring cell is protected from rotating by a locking
Pressure transmitters for level screw (8). As the result of this modular design, the measuring
cell and the electronics can be replaced separately from each
Measured variable: Level of aggressive and non-aggressive li- other. The set parameter data are retained.
quids in open and closed vessels.
At the top of the housing is a plastic cover (5), under which the
Nominal measuring ranges: 250 mbar ... 5 bar (3.63 ... 72.5 psi) input keys can be found.
Nominal diameter of the mounting flange:
• DN 80 or DN 100 ■ Function
• 3 inch or 4 inch Mode of operation of the electronics
In the case of level measurements in open containers, the low-
pressure connection of the measuring cell remains open 9
(measurement "compared to atmospheric"). 8
0 0 00 0
In the case of measurements in closed containers, the lower- M 00
pressure connection has to be connected to the container in or-
der to compensate the static pressure. 10
2 3 4 5
The wetted parts are constructed from a variety of materials de-
mC IA, UH
pending on the degree of corrosion resistance required.
7
■ Design
HART interface

EEPROM
6

Electronics
1 6
EEPROM

Sensor

Pe
Measuring cell

1 Measuring cell sensor


2 Instrument amplifier
3 Analog-to-digital converter
4 Microcontroller
5 Digital-to-analog converter
6 One non-volatile memory each in the measuring cell and electronics
7 HART interface
8 Three input keys (local operation)
9 Digital display
10 Diode circuit and connection for external ammeter
IA Output current
UH Power supply
Pe Input variable

Front view Function diagram of the electronics


The transmitter consists of various components depending on The bridge output voltage created by the sensor (1, Figure
the order. The possible versions are listed in the ordering infor- "Function diagram of the electronics") is amplified by the instru-
mation. The components described below are the same for all ment amplifier (2) and digitized in the analog-to-digital converter
transmitters. (3). The digital information is evaluated in a microcontroller, its li-
The rating plate (3, Figure "Front view") with the Order No. is lo- nearity and temperature response corrected, and converted in a
cated on the side of the housing. The specified number together digital-to-analog converter (5) into an output current of 4 to
with the ordering information provide details on the optional de- 20 mA.
sign details and on the possible measuring range (physical pro- The diode circuit (10) protects against incorrect polarity.
perties of built-in sensor element).
The data specific to the measuring cell, the electronics data, and
The approval label is located on the opposite side. the parameter data are stored in the two non-volatile memories
The housing is made of die-cast aluminium or stainless steel pre- (6). The one memory is coupled to the measuring cell, the other
cision casting. A round cover is screwed on at the front and rear to the electronics. As the result of this modular design, the elec-
of the housing. The front cover (6) can be fitted with a viewing tronics and the measuring cell can be replaced separately from
pane so that the measured values can be read directly on the di- each other.
gital display. The inlet (4) for the electrical connection is located Using the 3 input keys (8) you can parameterize the pressure
either on the left or right side. The unused opening on the oppo- transmitter directly at the point of measurement. The input keys
site side is sealed by a blanking plug. The protective earth con- can also be used to control the view of the results, the error mes-
nection is located on the rear of the housing. sages and the operating modes on the digital display (9).

2/24 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series
The HART modem (7) permits parameterization using a protocol Measuring cell for absolute pressure from differential pressure
according to the HART specification.
The pressure transmitters with spans ≤ 63 bar measure the input
series
2
pressure compared to atmosphere, transmitters with spans
≥ 160 bar compared to vacuum.
2 3 4 1 Reference vacuum
Mode of operation of the measuring cells 2 Overload diaphragm
Measuring cell for pressure 3 Silicon pressure sensor
4 O-ring
5 5 Process flange
6 Seal diaphragm
1 pe 7 Body of measuring cell
6 8 Filling liquid
pe Absolute pressure as
input variable
5
4
8 7

3
1 1 Measuring cell
2 Process connection
3 Seal diaphragm
4 Filling liquid Measuring cell for absolute pressure from differential pressure series,
5 Silicon pressure sensor functional diagram
pe Pressure as input variable The input pressure pe is transmitted through the seal diaphragm
2
(6, Figure "Measuring cell for absolute pressure from differential
pressure series, functional diagram") and the filling liquid (8) to
p the silicon pressure sensor (3).
e
The difference in pressure between the input pressure pe and
the reference vacuum (1) on the low-pressure side of the measu-
Measuring cell for pressure, functional diagram ring cell flexes the measuring diaphragm. The resistance of the
four piezo-resistors fitted in the diaphragm in a bridge circuit
The pressure pe is applied through the process connection (2, thus changes. This change in resistance results in a bridge out-
Figure "Measuring cell for pressure, functional diagram) to the put voltage proportional to the absolute pressure.
measuring cell (1). This pressure is subsequently transmitted
further through the seal diaphragm (3) and the filling liquid (4) to An overload diaphragm is installed to provide protection from
the silicon pressure sensor (5) whose measuring diaphragm is overloads. If the measuring limits are exceeded, the overload di-
then flexed. The resistance of the four piezo-resistors fitted in the aphragm (2) is flexed until the seal diaphragm rests on the body
diaphragm in a bridge circuit thus changes. This change in re- of the measuring cell (7), thus protecting the silicon pressure
sistance results in a bridge output voltage proportional to the in- sensor from overloads.
put pressure.
Measuring cell for differential pressure and flow
Measuring cell for absolute pressure from pressure series

2 3 4

1 Seal diaphragm
2 O-ring
3 Overload diaphragm
5 4 Silicon pressure sensor
4 1 - + 1 5 Process flange
5 6 Body of measuring cell
3
7 Filling liquid
1
1 Measuring cell
7 6
2 Process connection
3 Seal diaphragm
4 Filling liquid
5 Silicon absolute pressure sensor
pe Absolute pressure as input variable Measuring cell for differential pressure and flow, functional diagram

2 The differential pressure is transmitted through the seal dia-


pe phragms (1, Figure "Measuring cell for differential pressure and
flow, functional diagram") and the filling liquid (7) to the silicon
pressure sensor (4).
The measuring diaphragm is flexed by the applied differential
pressure. The resistance of the four piezo-resistors fitted in the
Measuring cell for absolute pressure from the pressure series, functional
diagram diaphragm in a bridge circuit thus changes. This change in re-
sistance results in a bridge output voltage proportional to the ab-
The absolute pressure pe is transmitted through the seal dia- solute pressure.
phragm (3, Figure "Measuring cell for absolute pressure from
pressure series, functional diagram") and the filling liquid (4) to An overload diaphragm is installed to provide protection from
the silicon absolute pressure sensor (5) whose measuring dia- overloads. If the measuring limits are exceeded, the overload di-
phragm is then flexed. The resistance of the four piezo-resistors aphragm (2) is flexed until the seal diaphragm rests on the body
fitted in the diaphragm in a bridge circuit thus changes. This of the measuring cell (7), thus protecting the silicon pressure
change in resistance results in a bridge output voltage proporti- sensor from overloads.
onal to the input pressure.

Siemens FI 01· 2005 2/25


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series
Measuring cell for level The following diagnostics functions are available using HART
2 communication:
• Zero correction display
3 4 5 6 7 • Event counter
• Limit transmitter
2 • Saturation alarm
8
+
• Slave pointer
- • Simulation functions
• Maintenance timer
1 10
9 Parameterization using the input keys (local operation)
With the input keys you can easily set the most important para-
meters without any additional equipment.
1 Flange with tube 6 Silicon pressure sensor
2 Seal diaphragm on 7 O-ring Parameterization using HART communication
mounting flange 8 Process flange
3 Seal diaphragm 9 Filling liquid Parameterization using HART communication is performed with
4 Body of measuring cell 10 Capillary with filling liquid a HART communicator or a PC.
5 Overload diaphragm of mounting flange
+

Measuring cell for level, functional diagram


SITRANS P 230 ... 1100 W Power supply
The input pressure (hydrostatic pressure) acts hydraulically on transmitter
the measuring cell through the seal diaphragm on the mounting
flange (2, Figure "Measuring cell for level, functional diagram"). HART
This differential pressure is subsequently transmitted further th- communicator
rough the measuring cell (3) and the filling liquid (9) to the silicon
pressure sensor (6) whose measuring diaphragm is then flexed.
HART communication between a HART communicator and a pressure
The resistance of the four piezo-resistors fitted in the diaphragm transmitter
in a bridge circuit thus changes.
This change in resistance results in a bridge output voltage pro- When parameterizing with the HART communicator, the connec-
portional to the differential pressure. tion is made directly to the 2-wire system.

An overload diaphragm is installed to provide protection from


overloads. If the measuring limits are exceeded, the overload di-
aphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure SITRANS P 230 ... 500 W Power supply
sensor from overloads. transmitter

Parameterization PC or
HART laptop
Depending on the version, there are different possibilities for pa- modem
rameterizing the pressure transmitter and for setting or scanning
the parameters. RS 232

Adjustable parameters
HART communication between a PC communicator and a pressure
Parameters Input keys HART com- transmitter
munication
Start of scale x x When parameterizing with a PC, the connection is made through
a HART modem.
Full-scale value x x
The signals needed for communication in conformity with the
Electrical damping x x HART 5.x or 6.x protocols are superimposed on the output cur-
Start-of-scale value without application of a x x rent using the Frequency Shift Keying (FSK) method.
pressure ("Blind setting")
Physical dimensions available for the display
End-of-scale value without application of a x x
pressure ("Blind setting") Physical variable Physical dimensions
Zero adjustment x x Pressure (setting can also Pa, MPa, kPa, hPa, bar, mbar, torr, atm,
be made in the factory) psi, g/cm2, kg/cm2, inH20, inH20 (4 °C),
Current transmitter x x mmH20, ftH20, inHg, mmHg
Fault current x x Level (height data) m, cm, mm, ft, in
Disabling of keys, write protection x x 1) Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp,
Type of dimension and actual dimension x x gallon, bushel, barrel, barrel liquid

Characteristic (linear / square-rooted) x 2) x 2) Volume flow m3/d, m3/h, m3/s, l/min, l/s, ft3/d, ft3/min,
ft3/s, US gallon/min, US gallon/s
Input of characteristic x
Mass flow t/d, t/h, t/min, kg/d, kg/h, kg/min, kg/s, g/d,
Freely-programmable LCD x g/h, g/min, g/s, lb/d, lb/h, lb/min, lb/s,
LTon/d, LTon/h, STon/d, STon/h, STon/min
Diagnostics functions x
1)
Total mass flow t, kg, g, lb, oz, LTon, STon
Cancel apart from write protection
2)
Only differential pressure Temperature K, °C, °F, °R
Miscellaneous %, mA

2/26 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for pressure

■ Technical specifications
2
Process connection Connection shank G½A to DIN
EN 837-1, female thread ½-14
SITRANS P pressure transmitters, DS III series, for pressure NPT or oval flange (PN 160
(MWP 2320)) with mounting
Input thread M10 or 7/16-20 UNF to EN
Measured variable Pressure 61518

Span (continuously adjustable) Maximum working pressure Power supply UH

• 0.01 ... 1 bar (0.145 ... 14.5 psi) 6 bar (87 psi) Terminal voltage on transmitter 10.5 ... 45 V DC
10.5 ... 30 V DC in intrinsically-
• 0.04 ... 4 bar (0.58 ... 58 psi) 10 bar (145 psi) safe mode
• 0.16 ... 16 bar (2.32 ... 232 psi) 32 bar (464 psi) Certificates and approvals
• 0.6 ... 63 bar (9.14 ... 914 psi) 100 bar (1450 psi) Classification according to pressure For gases of fluid group 1 and
equipment directive liquids of fluid group 1; complies
• 1.6 ... 160 bar (23.2 ... 2320 psi) 250 bar (3626 psi) (DRGL 97/23/EC) with requirements of article 3,
• 4.0 ... 400 bar (58 ... 5802 psi) 500 bar (7252 psi) paragraph 3 (sound engineering
practice)
Lower measuring limit
Explosion protection
• Measuring cell with silicone oil fil- 30 mark (0.435 psi) absolute
ling • Intrinsic safety "i" PTB 99 ATEX 2122
Upper measuring limit 100% of max. span (max. 160 bar - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6
(2320 psi) with oxygen measure- - Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
ment and inert liquid)
re temperature class T4;
Output -40 ... +70 °C (-40 ... +158 °F)
temperature class T5;
Output signal 4 ... 20 mA -40 ... +60 °C (-40 ... +140 °F)
Measuring accuracy temperature class T6
Reference conditions Increasing characteristic - Connection To certified intrinsically-safe cir-
Start-of-scale value 0 bar cuits with maximum values:
Stainless steel seal diaphragm Ui = 30 V, Ii = 100 mA,
Silicone oil filling Pi = 750 mW; Ri = 300 Ω
Room temperature (25 °C (77 °C)) - Effective internal inductance/ca- Li = 0.4 mH, Ci = 6 nF
r: Span ratio (r = max. span / set pacitance
span)
• Explosion-proof "d" PTB 99 ATEX 1160
Error in measurement and fixed-
point setting (including hysteresis - Identification Ex II 1/2 G EEx d IIC T4/T6
and repeatability) - Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
• Linear characteristic re temperature class T4;
-40 ... +60 °C (-40 ... +140 °F)
- r ≤ 10 ≤ (0.0029 ⋅ r +0.071)% temperature class T6
- 10 < r ≤ 30 ≤ (0.0045 ⋅ r +0.071)% - Connection To circuits with values:
- 30 < r ≤ 100 ≤ (0.005 ⋅ r +0.05)% UH = 10.5 ... 45 V DC
Influence of ambient temperature • Dust explosion protection for zone PTB 01 ATEX 2055
20
• With -10 ... +60 °C (14 ... 140 °F) ≤ (0.08 ⋅ r +0.1)%
- Identification Ex II 1 D IP65 T 120°°C
• With -40 ... -10 °C and ≤ (0.1 ⋅ r +0.15)% / 10 K Ex II 1/2 D IP65 T 120 °C
+60 °C ... +85 °C (≤ (0.1 ⋅ r +0.15)% / 18 °F)
(-40 ... +14 and 140 ... 185 °F) - Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
re
Rated conditions
- Max.surface temperature 120 °C (248 °F)
Degree of protection (to EN 60529) IP65
- Connection To certified intrinsically-safe cir-
Process temperature cuits with maximum values:
• Measuring cell with silicone oil fil- -40 ... +100 °C (-40 ... +212 °F) Ui = 30 V, Ii = 100 mA,
ling Pi = 750 mW, Ri = 300 Ω

• Measuring cell with inert filling li- -20 ... +100 °C (-4 ... +212 °F) - Effective internal inductance/ca- Li = 0.4 mH, Ci = 6 nF
quid pacitance

• In conjunction with dust explosion -20 ... +60 °C (-4 ... +140 °F) • Dust explosion protection for zone PTB 01 ATEX 2055
protection 21/22

Design - Identification Ex II 2 D IP65 T 120 °C

Weight (without options) ≈ 1.5 kg (≈ 3.3 lb) - Connection To circuits with values:
UH = 10.5 ... 45 V DC;
Wetted parts materials Pmax = 1.2 W
• Connection shank Stainless steel, mat. No. • Type of protection "n" (zone 2) TÜV 01 ATEX 1696 X
1.4404/316L or Hastelloy C4, mat.
No. 2.4610 - Identification Ex II 3 G EEx nA L IIC T4/T5/T6

• Seal diaphragm Stainless steel, mat. No. • Explosion protection to FM Certificate of Compliance
1.4404/316L or Hastelloy C276, 3008490
mat. No. 2.4819 - Identification (XP/DIP) or (IS); CL I, DIV 1, GP ABCD T4...T6;
Measuring cell filling Silicone oil or inert filling liquid (NI) CL II, DIV 1, GP EFG; CL III; CL I,
(max. 160 bar (2320 psi) with oxy- ZN 0/1 AEx ia IIC T4...T6; CL I,
gen measurement) DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III

Siemens FI 01· 2005 2/27


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for pressure

2
• Explosion protection to CSA Certificate of Compliance
1153651
- Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

■ Dimensional drawings

15 55 4)
138 (5.4) (0.6) ca. 30 (1.2) 100 (3.94)
(0.6)
69 50 28 ca. 96 (3.78) 6 2
(2.7) (1.97) (1.1)
(0.8)
20

(1.97)
50
(3.15)
ø 80

3 3
117 (4.6)

171 (6.7)
1) 8

237 (9.3)
1) 4
5
68 (2.7)

120 (4.7)
1
72 (2.8)

(1,44)
36,5
123 (4.8)
7
min. 77 (3.0) 5)
105 (4.1)

1 Process connection:
- ½-14 NPT,
- connection shank G½A or
- oval flange
2 Blanking plug
3 Electrical connection:
- screwed gland Pg 13,5 (adapter)2) 3),
- screwed gland M20x1,5 3),
- screwed gland ½-14 NPT or
- Han 7D/ Han 8U plug 2) 3)
4 Terminal side
5 Electronics side, digital display (longer overall
length for cover with window) 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing
6 Protective cover over keys 2) Not with type of protection "explosion-proof enclosure"
7 Mounting bracket (option) 3) Not with type of protection "FM + CSA [is + xp]"
8 Screw cover - safety bracket (only for type of protection 4) 45 mm (1.8 inch) for Pg 13,5 with adapter
"Explosion-proof enclosure", not shown in the drawing) 5) Minimum distance for rotation

SITRANS P pressure transmitters, DS III series for pressure, dimensional drawing, dimensions in mm (inch)

2/28 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for pressure

2
Selection and Ordering data Order No. 1) For oxygen application, add Order code E10.
SITRANS P pressure transmitter, DS III series, } 7 M F 4 0 3 3 - 2) Without cable gland, with blanking plug
for pressure 3) With enclosed cable gland EEx ia and blanking plug
77777 - 7777 4) Not together with type of protection "Explosion-proof"
2-wire system
Measuring cell filling Measuring cell
cleaning
Silicone oil Standard } 1
Inert liquid1) Grease-free 3
Measured span
0.01 ... 1 bar (0.15 ... 14.5 psi) } B
0.04 ... 4 bar (0.58 ... 58 psi) } C
0.16 ... 16 bar (2.32 ... 232 psi) } D
0.63 ... 63 bar (9.14 ... 914 psi) } E
1.6 ... 160 bar (23.2 ... 2320 psi) } F
4.0 ... 400 bar (58.0 ... 5802 psi) } G
Wetted parts materials
Seal diaphragm Process connection
Stainless steel Stainless steel } A
Hastelloy Stainless steel B
Hastelloy Hastelloy C
Version as diaphragm seal Y0
Process connection
• Connection shank G½B to EN 837-1 } 0
• Female thread ½-14 NPT 1
• Oval flange made of stainless steel,
max. span 160 bar (2320 psi)
- Mounting thread 7/16-20 UNF to 2
EN 61518
- Mounting thread M10 to DIN 19213 3
Non-wetted parts materials
• Housing made of die-cast aluminium } 0
• Housing stainless steel precision casting 3
Design
• Standard design 1
• International version, English label inscriptions, } 2
documentation in 5 languages on CD
Explosion protection
• without A
• with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)" B
- "Explosion-proof (EEx d)" 2) D
- "Intrinsic safety and explosion-proof enclosure } P
(EEx ia + EEx d)" 3)
- "n (zone 2)" E
- "Intrinsic safety, explosion-proof enclosure and R
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 3)
• with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 2) NC
Electrical connection / cable inlet
• Screwed gland Pg 13.5 (adapter) 4) A
• Screwed gland M20x1.5 } B
• Screwed gland ½-14 NPT C
• Han 7D plug (plastic housing) incl. mating D
connector 4)
Display
• without (digital indicator hidden, setting: mA) } 1
• with visible digital indicator, setting: mA 6

• with customer-specific digital indicator (setting 7


as specified, Order code "Y21" or "Y22" required)
} Available ex stock
Power supply units see "SITRANS I power supply units and input isola-
tors".
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation

Siemens FI 01· 2005 2/29


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for pressure

2
Further designs Order code Additional data Order code
Please add "-Z" to Order No. and specify Order code. Please add "-Z" to Order No. and specify Order code.
Pressure transmitter with mounting bracket made of: Measuring range to be set Y01
• Steel A01 specify in plain text:
• Stainless steel A02 Y01: ... to ... mbar, bar, kPa, MPa, psi
Plug Measuring point number/identification Y15
• Han 7D (metal, gray) A30 max. 16 characters, specify in plain text:
• Han 8U (instead of Han 7D) A31 Y15: ...........................................

Rating plate inscription Measuring point text Y16


(instead of German) max. 27 characters, specify in plain text:
Y16: ...........................................
• English B11
• French B12 Entry of HART address (TAG) Y17
• Spanish B13 max. 8 characters, specify in plain text:
• Italian B14 Y17: ...........................................

English rating plate B21 Setting of pressure indicator in pressure units Y21
Pressure units in inH2O or psi specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Manufacturer's test certificate M C11 Note:
(calibration certificate) The following pressure units can be selected:
to DIN 55350, Part 18 and to ISO 8402 bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
Acceptance test certificate B C12 psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
to EN 10204-3.1.B *) Reference temperature 20 °C

Factory certificate C14 Setting of pressure indicator in non-pressure units Y22 + Y01
to EN 10204-2.2 specify in plain text:
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
Certificate "Functional Safety (SIL)" C20 (specification of measuring range in pressure units
"Y01" is essential, unit with max. 5 characters)
Setting of upper limit of output signal to 22.0 mA D05
Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
Acid gas version to NACE D07 factory
(only together with seal diaphragm made of Hastelloy)
Ordering example
Type of protection IP68 D12 Item line: 7MF4033-1EA00-1AA7-Z
(not together with Han 7D / Han 8U plug, B line: A01 + Y01 + Y21
Pg 13.5 screwed gland)
C line: Y01: 10 ... 20 bar (145 ... 290 psi)
Digital indicator along side the input keys D27 C line: Y21: bar (psi)
(only together with the devices 7MF4033-....0-.A.6
or -.A.7-Z, Y21 or Y22 + Y01)
Use in or at zone 1D/2D E01
(only together with type of protection "Intrinsic safety
(EEx ia)"
Use at zone 0 E02
(only together with type of protection "Intrinsic safety
(EEx ia)"
Oxygen application E10
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

2/30 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from pressure series)

■ Technical specifications
2
Process connection Connection shank G½A to DIN
EN 837-1, female thread ½-14
SITRANS P pressure transmitters, DS III series for absolute pres- NPT or oval flange (PN 160
sure, from the pressure series (MWP 2320)) with mounting
thread M10 or 7/16-20 UNF to
Input EN 61518
Measured variable Absolute pressure Power supply UH
Span Maximum working pressure Terminal voltage on pressure trans- 10.5 ... 45 V DC
• 8.3 ... 250 mbar (0.12 ... 3.6 psi) 6 bar (87 psi) mitter 10.5 ... 30 V DC in intrinsically-
safe mode
• 43 ... 1300 mbar (0.62 ... 18.9 psi) 10 bar (145 psi)
Certificates and approvals
• 160 ... 5000 mbar 30 bar (435 psi)
(2.32 ... 72.5 psi) Classification according to pressure For gases of fluid group 1 and
equipment directive liquids of fluid group 1; complies
• 1 ... 30 bar (14.5 ... 435 psi) 100 bar (1450 psi) (DRGL 97/23/EC) with requirements of article 3,
paragraph 3 (sound engineering
Lower measuring limit practice)
• Measuring cell with silicone oil fil- 0 mark (0 psi) absolute Explosion protection
ling
• Intrinsic safety "i" PTB 99 ATEX 2122
Upper measuring limit 100% of max. span (max. 160 bar
(2320 psi) with oxygen measure- - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6
ment and inert liquid)
- Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
Output re temperature class T4;
-40 ... +70 °C (-40 ... +158 °F)
Output signal 4 ... 20 mA temperature class T5;
Measuring accuracy -40 ... +60 °C (-40 ... +140 °F)
temperature class T6
Reference conditions Increasing characteristic
Start-of-scale value 0 bar - Connection To certified intrinsically-safe cir-
Stainless steel seal diaphragm cuits with maximum values:
Silicone oil filling Ui = 30 V, Ii = 100 mA,
Room temperature (25 °C (77 °F)) Pi = 750 mW; Ri = 300 Ω
r: Span ratio
- Effective internal inductance/ca- Li = 0.4 mH, Ci = 6 nF
(r = max. span / set span) pacitance
Error in measurement and fixed- • Explosion-proof "d" PTB 99 ATEX 1160
point setting (including hysteresis
and repeatability) - Identification Ex II 1/2 G EEx d IIC T4/T6
• Linear characteristic - Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
re temperature class T4;
- r ≤ 10 ≤ (0.0029 ⋅ r +0.071)% -40 ... +60 °C (-40 ... +140 °F)
- 10 < r ≤ 30 ≤ (0.0045 ⋅ r +0.071)% temperature class T6
Influence of ambient temperature - Connection To circuits with values:
UH = 10.5 ... 45 V DC
• With -10 ... +60 °C (14 ... 140 °F) ≤ (0.1 ⋅ r +0.2)%
• Dust explosion protection for PTB 01 ATEX 2055
• With -40 ... -10 °C and ≤ (0.1 ⋅ r +0.15)% / 10 K zone 20
+60 °C ... +85 °C (≤ (0.1 ⋅ r +0.15)% / 18 °F)
(-40 ... +14 and 140 ... 185 °F) - Identification Ex II 1 D IP65 T 120 °C
Ex II 1/2 D IP65 T 120 °C
Rated conditions
- Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
Degree of protection (to EN 60529) IP65 re
Process temperature - Max.surface temperature 120 °C (248 °F)
• Measuring cell with silicone oil fil- -40 ... +100 °C (-40 ... +212 °F) - Connection To certified intrinsically-safe cir-
ling cuits with maximum values:
• Measuring cell with inert filling li- -20 ... +100 °C (-4 ... +212 °F) Ui = 30 V, Ii = 100 mA,
quid Pi = 750 mW, Ri = 300 Ω
• In conjunction with dust explosion -20 ... +60 °C (-4 ... +140 °F) - Effective internal inductance/ca- Li = 0.4 mH, Ci = 6 nF
protection pacitance
Design • Dust explosion protection for zone PTB 01 ATEX 2055
21/22
Weight (without options) ≈ 1.5 kg (≈ 3.3 lb)
- Identification Ex II 2 D IP65 T 120 °C
Wetted parts materials
- Connection To circuits with values:
• Connection shank Stainless steel, mat. No. UH = 10.5 ... 45 V DC;
1.4404/316L or Hastelloy C4, mat. Pmax = 1.2 W
No. 2.4610
• Type of protection "n" (zone 2) TÜV 01 ATEX 1696 X
• Seal diaphragm Stainless steel, mat. No.
1.4404/316L or Hastelloy C276, - Identification Ex II 3 G EEx nA L IIC T4/T5/T6
mat. No. 2.4819 • Explosion protection to FM Certificate of Compliance
Measuring cell filling Silicone oil or inert filling liquid 3008490
(max. 160 bar (2320 psi) with oxy- - Identification (XP/DIP) or (IS); CL I, DIV 1, GP ABCD T4...T6;
gen measurement) (NI) CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III

Siemens FI 01· 2005 2/31


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from pressure series)

2
• Explosion protection to CSA Certificate of Compliance
1153651
- Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

■ Dimensional drawings

15 55 4)
138 (5.4) (0.6) ca. 30 (1.2) 100 (3.94)
(0.6)
69 50 28 ca. 96 (3.78) 6 2
(2.7) (1.97) (1.1)
(0.8)
20

(1.97)
50
(3.15)
ø 80

3 3
117 (4.6)

171 (6.7)
1) 8

237 (9.3)
1) 4
5
68 (2.7)

120 (4.7)
1
72 (2.8)

(1,44)
36,5
123 (4.8)
7
min. 77 (3.0) 5)
105 (4.1)

1 Process connection:
- ½-14 NPT,
- connection shank G½A or
- oval flange
2 Blanking plug
3 Electrical connection:
- screwed gland Pg 13,5 (adapter)2) 3),
- screwed gland M20x1,5 3),
- screwed gland ½-14 NPT or
- Han 7D/ Han 8U plug 2) 3)
4 Terminal side
5 Electronics side, digital display (longer overall
length for cover with window) 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing
6 Protective cover over keys 2) Not with type of protection "explosion-proof enclosure"
7 Mounting bracket (option) 3) Not with type of protection "FM + CSA [is + xp]"
8 Screw cover - safety bracket (only for type of protection 4) 45 mm (1.8 inch) for Pg 13,5 with adapter
"Explosion-proof enclosure", not shown in the drawing) 5) Minimum distance for rotation

SITRANS P pressure transmitters, DS III series for absolute pressure, from the pressure series, dimensional drawing, dimensions in mm (inch)

2/32 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from pressure series)
4) Not together with type of protection "Explosion-proof"

2
Selection and Ordering data Order No. E) Combinations of the versions marked with E) are subject to the export regu-
SITRANS P pressure transmitters, DS III series 7MF 4 2 3 3 - lations AL: 2B230, ECCN: N.
for absolute pressure from the pressure series
2-wire system 77777 - 7777
Measuring cell filling Measuring cell
cleaning
Silicone oil Standard 1
Inert liquid Grease-free 3
Measured span
8.3 ... 250 mbar (0.12 ... 3.63 psi) E) D
43 ... 1300 mbar (0.62 ... 18.9 psi) E) F
0.16 ... 5 bar (2.32 ... 72.5 psi) E) G
1 ... 30 bar (14.5 ... 435 psi) H
Wetted parts materials
Seal diaphragm Process connection
Stainless steel Stainless steel A
Hastelloy Stainless steel E) B
Hastelloy Hastelloy E) C
Version for diaphragm seal 1) Y0
Process connection
• Connection shank G½B to EN 837-1 0
• Female thread ½-14 NPT 1
• Oval flange made of stainless steel,
max. span 160 bar (2320 psi)
- Mounting thread 7/16-20 UNF to 2
EN 61518
- Mounting thread M10 to DIN 19213 3
Non-wetted parts materials
• Housing made of die-cast aluminium 0
• Housing stainless steel precision casting 3
Design
• Standard design 1
• International version, English label inscriptions, 2
documentation in 5 languages on CD
Explosion protection
• without A
• with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)" B
- "Explosion-proof (EEx d)" 2) D
- "Intrinsic safety and explosion-proof enclosure P
(EEx ia + EEx d)" 3)
- "n (zone 2)" E
- "Intrinsic safety, explosion-proof enclosure and R
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 3)
• with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 2) NC
Electrical connection / cable inlet
• Screwed gland Pg 13.5 4) A
• Screwed gland M20x1.5 B
• Screwed gland ½-14 NPT C
• Han 7D plug (plastic housing) incl. mating D
connector 4)
Display
• without (digital indicator hidden, setting: mA) 1
• with visible digital indicator 6
• with customer-specific digital indicator (setting 7
as specified, Order code "Y21" required)
Power supply units see "SITRANS I power supply units and input isola-
tors".
The device is delivered together with brief instructions (Leporello) and
a CD-ROM containing detailed documentation.

1) Version 7MF4233-1DY... only up to max. span 200 mbar (2.9 psi)


2) Without cable gland, with blanking plug
3) With enclosed cable gland EEx ia and blanking plug

Siemens FI 01· 2005 2/33


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from pressure series)

2
Further designs Order code Further designs Order code
Please add "-Z" to Order No. and specify Order code. Please add "-Z" to Order No. and specify Order code.
Pressure transmitter with mounting bracket made of: Additional data
• Steel A01 Measuring range to be set Y01
• Stainless steel A02 specify in plain text:
Plug Y01: ... to ... mbar, bar, kPa, MPa, psi
• Han 7D (metal, gray) A30 Measuring point number/identification Y15
• Han 8U (instead of Han 7D) A31 max. 16 characters, specify in plain text:
Rating plate inscription Y15: ...........................................
(instead of German) Measuring point text Y16
• English B11 max. 27 characters, specify in plain text:
• French B12 Y16: ...........................................
• Spanish B13 Entry of HART address (TAG) Y17
• Italian B14 max. 8 characters, specify in plain text:
English rating plate B21 Y17: ...........................................
Pressure units in inH2O or psi Setting of pressure indicator in pressure units Y21
Manufacturer's test certificate M C11 specify in plain text (standard setting: mA):
(calibration certificate) Y21: mbar, bar, kPa, MPa, psi, ...
to DIN 55350, Part 18 and to ISO 8402 Note:
The following pressure units can be selected:
Acceptance test certificate B C12 bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
to EN 10204-3.1.B psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
Factory certificate C14 *) Reference temperature 20 °C
to EN 10204-2.2 Setting of pressure indicator in non-pressure units Y22 + Y01
Certificate "Functional Safety (SIL)" C20 specify in plain text:
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
Setting of upper limit of output signal to 22.0 mA D05 (specification of measuring range in pressure units
"Y01" is essential, unit with max. 5 characters)
Acid gas version to NACE D07
(only together with seal diaphragm made of Hastelloy) Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
factory
Type of protection IP68 D12
(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)
Digital indicator along side the input keys D27
(only together with the devices 7MF4233-....0-.A.6
or -.A.7-Z, Y21 or Y22 + Y01).
Use in or at zone 1D/2D E01
(only together with type of protection "Intrinsic safety
(EEx ia)"
Use at zone 0 E02
(only together with type of protection "Intrinsic safety
(EEx ia)"
Oxygen application E10
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

2/34 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from differential pressure series)

■ Technical specifications
2
Measuring cell filling Silicone oil or inert filling liquid
(max. 160 bar (2320 psi) with oxy-
SITRANS P pressure transmitters, DS III series for absolute pres- gen measurement)
sure, from the differential pressure series Process connection Female thread ¼-18 NPT and
Input flange connection to DIN 19 213
with mounting thread M10 or
Measured variable Absolute pressure 7/ -20 UNF
16
Span Maximum working pressure Power supply UH
• 8.3 ... 250 mbar (0.12 ... 3.6 psi) 32 bar (464 psi) Terminal voltage on pressure trans- 10.5 ... 45 V DC
• 43 ... 1300 mbar (0.62 ... 18.9 psi) 32 bar (464 psi) mitter 10.5 ... 30 V DC in intrinsically-
safe mode
• 160 ... 5000 mbar 32 bar (464 psi)
(2.32 ... 72.5 psi) Certificates and approvals

• 1 ... 30 bar (14.5 ... 435 psi) 160 bar (2320 psi) Classification according to pressure For gases of fluid group 1 and
equipment directive liquids of fluid group 1; complies
• 5.3 ... 100 bar (76.9 ... 1450 psi) 160 bar (2320 psi) (DRGL 97/23/EC) with requirements of article 3,
With connection thread M10 and paragraph 3 (sound engineering
7/ -20 UNF in the process flan- practice)
16
ges Explosion protection
Lower measuring limit • Intrinsic safety "i" PTB 99 ATEX 2122
• Measuring cell with silicone oil fil- 0 mark (0 psi) absolute - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6
ling
- Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
Upper measuring limit 100% of max. span (max. 160 bar re temperature class T4;
(2320 psi) with oxygen measure- -40 ... +70 °C (-40 ... +158 °F)
ment and inert liquid) temperature class T5;
Start of scale Continuously adjustable between -40 ... +60 °C (-40 ... +140 °F)
the measuring limits temperature class T6

Output - Connection To certified intrinsically-safe cir-


cuits with maximum values:
Output signal 4 ... 20 mA Ui = 30 V, Ii = 100 mA,
Pi = 750 mW; Ri = 300 Ω
Measuring accuracy
- Effective internal inductance/ca- Li = 0.4 mH, Ci = 6 nF
Reference conditions Increasing characteristic
pacitance
Start-of-scale value 0 bar
Stainless steel seal diaphragm • Explosion-proof "d" PTB 99 ATEX 1160
Silicone oil filling
Room temperature (25 °C (77 °F)) - Identification Ex II 1/2 G EEx d IIC T4/T6
r: Span ratio - Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
(r = max. span / set span) re temperature class T4;
Error in measurement and fixed- -40 ... +60 °C (-40 ... +140 °F)
point setting (including hysteresis temperature class T6
and repeatability) - Connection To circuits with values:
Linear characteristic UH = 10.5 ... 45 V DC

- r ≤ 10 ≤ (0.0029 ⋅ r + 0.071)% • Dust explosion protection for zone PTB 01 ATEX 2055
20
- 10 < r ≤ 30 ≤ (0.0045 ⋅ r + 0.071)%
- Identification Ex II 1 D IP65 T 120 °C
Influence of ambient temperature Ex II 1/2 D IP65 T 120 °C
• With -10 ... +60 °C (14 ... 140 °F) ≤ (0.1 ⋅ r +0.2)% - Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
Twice the value with 20-mbar re
(0.29 psi) measuring cell
- Max.surface temperature 120 °C (248 °F)
• With -40 ... -10 °C and ≤ (0.1 ⋅ r +0.15)% / 10 K
+60 °C ... +85 °C (≤ (0.1 ⋅ r +0.15)% / 18 °F) - Connection To certified intrinsically-safe cir-
(-40 ... +14 and 140 ... 185 °F) Twice the value with 20-mbar cuits with maximum values:
(0.29 psi) measuring cell Ui = 30 V, Ii = 100 mA,
Pi = 750 mW, Ri = 300 Ω
Rated conditions
- Effective internal inductance/ca- Li = 0.4 mH, Ci = 6 nF
Degree of protection (to EN 60529) IP65 pacitance
Process temperature • Dust explosion protection for PTB 01 ATEX 2055
zone 21/22
• Measuring cell with silicone oil fil- -40 ... +100 °C (-40 ... +212 °F)
ling - Identification Ex II 2 D IP65 T 120 °C
• Measuring cell with inert filling li- -20 ... +100 °C (-4 ... +212 °F) - Connection To circuits with values:
quid UH = 10.5 ... 45 V DC;
Pmax = 1.2 W
• In conjunction with dust explosion -20 ... +60 °C (-4 ... +140 °F)
protection • Type of protection "n" (zone 2) TÜV 01 ATEX 1696 X
Design - Identification Ex II 3 G EEx nA L IIC T4/T5/T6
Weight (without options) ≈ 4.5 kg (≈ 9.9 lb) • Explosion protection to FM Certificate of Compliance
3008490
Wetted parts materials
- Identification (XP/DIP) or (IS); CL I, DIV 1, GP ABCD T4...T6;
• Seal diaphragm Stainless steel, mat. No.
(NI) CL II, DIV 1, GP EFG; CL III; CL I,
1.4404/316L, Hastelloy C276,
ZN 0/1 AEx ia IIC T4...T6; CL I,
mat. No. 2.4819, Monel, mat. No.
DIV 2, GP ABCD T4...T6; CL II,
2.4360, tantalum or gold
DIV 2, GP FG; CL III

Siemens FI 01· 2005 2/35


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from differential pressure series)

2
• Explosion protection to CSA Certificate of Compliance
1153651
- Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

■ Dimensional drawings

15
(0.6) 138 (5.4) approx. 30 (1.2) 5) 100 (3.94)
50 6 2
(1.97)
(0.8)
20

(1.97)
50
(3.15)
Ø 80

117 (4.6)

198 (7.8)

approx. 261 (10.3)


1)
4
69 (2.7)
5 1) 77 (3) 4) 9
10
Space for rotation

8
1
of housing
134 (5.27)

96 (3.8)
11
ca. 96 (3.78) 52 (2.05)

72 (2.83)
105 (4.1) 68 (2.7)
120 (4.7)
1 Process connection: ¼-18 NPT (EN 61518)
2 Blanking plug
3 Electrical connection:
- screwed gland Pg 13,5 (adapter) 2) 3),
- screwed gland M20x1,5 3),
- screwed gland ½-14 NPT or
- Han 7D/ Han 8U plug 2) 3)
4 Terminal side
5 Electronics side, digital display (longer overall length for cover with window)
6 Protective cover over keys
7 Mounting bracket (option)
8 Sealing screw with valve (option) 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing
9 Screw cover - safety bracket (only for type of protection 2) Not with type of protection "explosion-proof enclosure"
"Explosion-proof enclosure", not shown in the drawing) 3) Not with type of protection "FM + CSA [is + xp]"
10 Lateral venting for liquid measurement 4) 92 mm (3.62 inch) for minimum distance to permit rotation with indicator
11 Lateral venting for gas measurement (suffix H02) 5) 45 mm (1.8 inch) for Pg 13,5 with adapter

SITRANS P pressure transmitters, DS III series for absolute pressure, from the differential pressure series, dimensional drawing, dimensions in mm
(inch)

2/36 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from differential pressure series)

2
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS P pressure transmitters, DS III series 7MF 4 3 3 3 - SITRANS P pressure transmitters, DS III series 7MF 4 3 3 3 -
for absolute pressure from the series for absolute pressure from the series
Differential pressure Differential pressure
2-wire system 77777 - 7777 2-wire system 77777 - 7777
Measuring cell filling Measuring cell Display
cleaning • without (digital indicator hidden, setting: mA) 1
Silicone oil Standard 1 • with visible digital indicator 6
Inert liquid1) Grease-free 3 • with customer-specific digital indicator (setting 7
Measured span as specified, Order code "Y21" required)
8.3 ... 250 mbar (0.12 ... 3.63 psi) E) D Power supply units see "SITRANS I power supply units and input isola-
43 ... 1300 mbar (0.62 ... 18.9 psi) E) F tors".
0.16 ... 5 bar (2.32 ... 72.5 psi) E) G Included in delivery of the device:
1 ... 30 bar (14.5 ... 435 psi) H • Brief instructions (Leporello)
5.3 ... 100 bar (76.9 ... 1450 psi) KE • CD-ROM with detailed documentation
• Sealing plug(s) or sealing screw(s) for the process flanges(s)
Wetted parts materials
Seal diaphragm Parts of measuring cell 1) For oxygen applications, add Order code E10.
2) Version 7MF4433-1DY... only up to max. span 200 mbar (2.9 psi)
Stainless steel Stainless steel A 3) Not for span "5.3 ... 100 bar (76.9 ... 1450 psi)"
Hastelloy Stainless steel E) B 4) Without cable gland, with blanking plug
Hastelloy Hastelloy E) C 5) With enclosed cable gland EEx ia and blanking plug
Tantalum Tantalum E 6) Not together with type of protection "Explosion-proof"
Monel Monel E) H E) Combinations of the versions marked with E) are subject to the export
Gold Gold L regulations AL: 2B230, ECCN: N.
Version for diaphragm seal 2) Y
Process connection
Female thread ¼-18 NPT with flange connection
• Sealing screw opposite process connection
- Mounting thread M10 to DIN 19213 0
- Mounting thread 7/16-20 UNF to EN 61518 2
• Vent on side of process flange 3)
- Mounting thread M10 to DIN 19213 4
- Mounting thread 7/16-20 UNF to EN 61518 6
Non-wetted parts materials
Process flange screws Electronics housing
Stainless steel Die-cast aluminium 2
Stainless steel Stainless steel precision 3
casting
Design
• Standard design 1
• International version, English label inscriptions, 2
documentation in 5 languages on CD
Explosion protection
• without A
• with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)" B
- "Explosion-proof (EEx d)" 4) D
- "Intrinsic safety and explosion-proof enclosure P
(EEx ia + EEx d)" 5)
- "n (zone 2)" E
- "Intrinsic safety, explosion-proof enclosure and R
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 5)
• with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 4) NC
Electrical connection / cable inlet
• Screwed gland Pg 13.5 6) A
• Screwed gland M20x1.5 B
• Screwed gland ½-14 NPT C
• Han 7D plug (plastic housing) incl. mating D
connector 6)

Siemens FI 01· 2005 2/37


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from differential pressure series)

2
Further designs Order code Further designs Order code
Please add "-Z" to Order No. and specify Order code. Please add "-Z" to Order No. and specify Order code.
Pressure transmitter with mounting bracket made of: Additional data
• Steel A01 Measuring range to be set Y01
• Stainless steel A02 specify in plain text:
O-rings for process flanges Y01: ... up to ... mbar, bar, kPa, MPa, psi
(instead of FPM (Viton)) Measuring point number/identification Y15
• PTFE (Teflon) A20 max. 16 characters, specify in plain text:
• FEP (with silicone core, approved for food) A21 Y15: ...........................................
• FFPM (Kalrez, compound 4079) A22 Measuring point text Y16
• NBR (Buna N) A23 max. 27 characters, specify in plain text:
Plug Y16: ...........................................
• Han 7D (metal, gray) A30 Entry of HART address (TAG) Y17
• Han 8U (instead of Han 7D) A31 max. 27 characters, specify in plain text:
Sealing screws A40 Y17: ...........................................
¼-18 NPT, with valve in material of process flanges Setting of pressure indicator in pressure units Y21
Rating plate inscription specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
(instead of German)
Note:
• English B11 The following pressure units can be selected:
• French B12
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
• Spanish B13 psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
• Italian B14 *) Reference temperature 20 °C
English rating plate B21 Setting of pressure indicator in non-pressure units Y22 + Y01
Pressure units in inH2O or psi specify in plain text:
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
Manufacturer's test certificate M C11
(specification of measuring range in pressure units
(calibration certificate)
"Y01" is essential, unit with max. 5 characters)
to DIN 55350, Part 18 and to ISO 8402
Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
Acceptance test certificate B C12 factory
to EN 10204-3.1.B
Factory certificate C14
to EN 10204-2.2
Certificate "Functional Safety (SIL)" C20
Setting of upper limit of output signal to 22.0 mA D05
Acid gas version to NACE D07
(only together with seal diaphragm made of Hastelloy)
Type of protection IP68 D12
(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)
Digital indicator along side the input keys D27
(only together with the devices 7MF4333-....0-.A6 or
-.A.7-Z, Y21 or Y22 + Y01)
Use in or at zone 1D/2D E01
(only together with type of protection "Intrinsic safety
(EEx ia)"
Use at zone 0 E02
(only together with type of protection "Intrinsic safety
(EEx ia)"
Oxygen application E10
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)
Interchanging of process connection side H01
Vent on side for gas measurements H02
Process flange
• Hastelloy K01
• Monel K02
• Stainless steel with PVDF insert K04
max. PN 10 (MWP 145 psi),
Max. temperature of medium 90 °C (194 °F)

2/38 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

■ Technical specifications
2
Influence of ambient temperature
• With -10 ... +60 °C (14 ... 140 °F) ≤ (0.08 ⋅ r +0.1)%
SITRANS P pressure transmitters, DS III series, for differential pres-
sure and flow • With -40 ... -10 °C and ≤ (0.1 ⋅ r +0.15)% / 10 K
+60 °C ... +85 °C (≤ (0.1 ⋅ r +0.15)% / 18 °F)
Input (-40 ... +14 and 140 ... 185 °F) Twice the value with 20-mbar
Measured variable Differential pressure and flow (0.29 psi) measuring cell.
Span Maximum working pressure Rated conditions
• PN 32 (MWP 464 psi) Degree of protection (to EN 60529) IP65
- 1 ... 20 mbar (0.0145 ... 0.29 psi) 32 bar (464 psi) Process temperature
• PN 160 (MWP 2320 psi) • Measuring cell with silicone oil fil- -40 ... +100 °C (-40 ... +212 °F)
- 1 ... 60 mbar (0.0145 ... 0.87 psi) 160 bar (2320 psi) ling

- 2.5 ... 250 mbar 160 bar (2320 psi) • Measuring cell with inert filling li- -20 ... +100 °C (-4 ... +212 °F)
(0.036 ... 3.63 psi) quid

- 6 ... 600 mbar (0.087 ... 8.7 psi) 160 bar (2320 psi) • In conjunction with dust explosion -20 ... +60 °C (-4 ... +140 °F)
protection
- 16 ... 1600 mbar 160 bar (2320 psi)
(0.232 ... 23.2 psi) Design

- 50 ... 5000 mbar 160 bar (2320 psi) Weight (without options) ≈ 4.5 kg (≈ 9.9 lb)
(0.725 ... 72.5 psi) Wetted parts materials
- 0.3 ... 30 bar (4.35 ... 435 psi) 160 bar (2320 psi) • Seal diaphragm Stainless steel, mat. No.
• PN 420 (MWP 6092) 1.4404/316L, Hastelloy C276,
mat. No. 2.4819, Monel, mat. No.
- 2.5 ... 250 mbar 420 bar (6092 psi) 2.4360, tantalum or gold
(0.036 ... 3.63 psi)
Measuring cell filling Silicone oil or inert filling liquid
- 6 ... 600 mbar (0.087 ... 8.7 psi) 420 bar (6092 psi) (max. 160 bar (2320 psi) with oxy-
gen measurement)
- 16 ... 1600 mbar 420 bar (6092 psi)
(0.232 ... 23.3 psi) Process connection Female thread ¼-18 NPT and
flange connection to DIN 19 213
- 50 ... 5000 mbar 420 bar (6092 psi) with mounting thread M10 or
(0.725 ... 72.5 psi) 7/ -20 UNF to EN 61518
16
- 0.3 ... 30 bar (4.35 ... 435 psi) 420 bar (6092 psi) Power supply UH
Lower measuring limit Terminal voltage on pressure trans- 10.5 ... 45 V DC
• Measuring cell with silicone oil fil- -100% of max. span mitter 10.5 ... 30 V DC in intrinsically-
ling (-33% with 30 bar (435 psi) safe mode
measuring cell) or Certificates and approvals
30 mbar (0.44 psi) absolute
Classification according to pressure
Upper measuring limit 100% of max. span (max. 160 bar equipment directive
(2320 psi) with oxygen measure- (DRGL 97/23/EC)
ment and inert liquid)
• PN 32/160 (MWP 464/2320) For gases of fluid group 1 and
Output liquids of fluid group 1; complies
Output signal 4 ... 20 mA with requirements of article 3,
paragraph 3 (sound engineering
Measuring accuracy practice)
Reference conditions Increasing characteristic • PN 420 (MWP 6092) For gases of fluid group 1 and
Start-of-scale value 0 bar liquids of fluid group 1; complies
Stainless steel seal diaphragm with basic safety requirements of
Silicone oil filling article 3, paragraph 1 (appendix
Room temperature (25 °C (77 °F)) 1); assigned to category III, con-
r: Span ratio formity evaluation module H by
(r = max. span / set span) the TÜV Nord
Error in measurement and fixed- Explosion protection
point setting (including hysteresis
and repeatability) • Intrinsic safety "i" PTB 99 ATEX 2122
• Linear characteristic - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6
- r ≤ 10 ≤ (0.0029 ⋅ r + 0.071)% - Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
re temperature class T4;
- 10 < r ≤ 30 ≤ (0.0045 ⋅ r + 0.071)% -40 ... +70 °C (-40 ... +158 °F)
- 30 < r ≤ 100 ≤ (0.005 ⋅ r +0.05)% temperature class T5;
-40 ... +60 °C (-40 ... +140 °F)
• Square-root characteristic (flow temperature class T6
> 50%)
- Connection To certified intrinsically-safe cir-
- r ≤ 10 ≤ 0.1% cuits with maximum values:
Ui = 30 V, Ii = 100 mA,
- 10 < r ≤ 30 ≤ 0.2%
Pi = 750 mW; Ri = 300 Ω
• Square-root characteristic (flow
- Effective internal inductance/ca- L i = 0.4 mH, Ci = 6 nF
25 ... 50%)
pacitance
- r ≤ 10 ≤ 0.2%
- 10 < r ≤ 30 ≤ 0.4%

Siemens FI 01· 2005 2/39


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

2
• Explosion-proof "d" PTB 99 ATEX 1160
- Identification Ex II 1/2 G EEx d IIC T4/T6
- Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
re temperature class T4;
-40 ... +60 °C (-40 ... +140 °F)
temperature class T6
- Connection To circuits with values:
UH = 10.5 ... 45 V DC
• Dust explosion protection for PTB 01 ATEX 2055
zone 20
- Identification Ex II 1 D IP65 T 120 °C
Ex II 1/2 D IP65 T 120 °C
- Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
re
- Max.surface temperature 120 °C (248 °F)
- Connection To certified intrinsically-safe cir-
cuits with maximum values:
Ui = 30 V, Ii = 100 mA,
Pi = 750 mW, Ri = 300 Ω
- Effective internal inductance/ca- Li = 0.4 mH, Ci = 6 nF
pacitance
• Dust explosion protection for zone PTB 01 ATEX 2055
21/22
- Identification Ex II 2 D IP65 T 120 °C
- Connection To circuits with values:
UH = 10.5 ... 45 V DC;
Pmax = 1.2 W
• Type of protection "n" (zone 2) TÜV 01 ATEX 1696 X
- Identification Ex II 3 G EEx nA L IIC T4/T5/T6
• Explosion protection to FM Certificate of Compliance
3008490
- Identification (XP/DIP) or (IS); CL I, DIV 1, GP ABCD T4...T6;
(NI) CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III
• Explosion protection to CSA Certificate of Compliance
1153651
- Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

2/40 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

■ Dimensional drawings
2
15
(0.6) 138 (5.4) approx. 30 (1.2) 5) 100 (3.94)
50 6 2
(1.97)

(0.8)
20

(1.97)
50
(3.15)
Ø 80

117 (4.6)
3

198 (7.8)

approx. 261 (10.3)


1)
4
69 (2.7)
5 1) 77 (3) 4) 9
10
Space for rotation

8
1
of housing
134 (5.27)

96 (3.8)
11
ca. 96 (3.78) 52 (2.05)

72 (2.83)
105 (4.1) 68 (2.7)
120 (4.7)
1 Process connection: ¼-18 NPT (EN 61518)
2 Blanking plug
3 Electrical connection:
- screwed gland Pg 13,5 (adapter) 2) 3),
- screwed gland M20x1,5 3),
- screwed gland ½-14 NPT or
- Han 7D/ Han 8U plug 2) 3)
4 Terminal side
5 Electronics side, digital display (longer overall length for cover with window)
6 Protective cover over keys
7 Mounting bracket (option)
8 Sealing screw with valve (option) 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing
9 Screw cover - safety bracket (only for type of protection 2) Not with type of protection "explosion-proof enclosure"
"Explosion-proof enclosure", not shown in the drawing) 3) Not with type of protection "FM + CSA [is + xp]"
10 Lateral venting for liquid measurement 4) 92 mm (3.62 inch) for minimum distance to permit rotation with indicator
11 Lateral venting for gas measurement (suffix H02) 5) 45 mm (1.8 inch) for Pg 13,5 with adapter

SITRANS P pressure transmitters, DS III series for differential pressure and flow, dimensional drawing, dimensions in mm (inch)

Siemens FI 01· 2005 2/41


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

2 15
(0.6) 138 (5.4)
approx. 30 (1.18)8)
100 (3.94)
50 ca. 96 (3.78) 6 2
69 (2.7) (1.97)

(0.8)
20

(1.97)
50
(3.15)
Ø 80

3 3
4 1)

approx. 217 (8.54)7)


9
Space for rotation
5 1) 77 (3)4)
of housing

ca. 85 (3.35)6)
+ 8
8

67 (2.64)5) ca. 84,6 (3.33)

1 Process connection: ¼-18 NPT (EN 61518)


2 Blanking plug
3 Electrical connection:
- screwed gland Pg 13,5 (adapter) 2) 3),
- screwed gland M20x1,5 3),
- screwed gland ½-14 NPT or
- Han 7D/ Han 8U plug 2) 3) 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing
4 Terminal side 2) Not with type of protection "explosion-proof enclosure"
5 Electronics side, digital display (longer overall length for cover with window) 3) Not with type of protection "FM + CSA [is + xp]"
6 Protective cover over keys 4) 92 mm (3.6 inch) for minimum distance to permit rotation with indicator
7 Mounting bracket (option) 5) 74 mm (2.9 inch) for PN ³ 420 (MWP ³ 6092 psi)
8 Sealing screw with valve (option) 6) 91 mm (3.6 inch) for PN ³ 420 (MWP ³ 6092 psi)
9 Screw cover - safety bracket (only for type of protection 7) 219 mm (8.62 inch) for PN ³ 420 (MWP ³ 6092 psi)
"Explosion-proof enclosure", not shown in the drawing) 8) 45 mm (1.8 inch) for Pg 13,5 with adapter

SITRANS P pressure transmitters, DS III series for differential pressure and flow, with process covers for vertical differential pressure lines, dimensional
drawing, dimensions in mm (inch)

SITRANS P pressure transmitters, DS III series for differential pressure


and flow, with process covers for vertical differential pressure lines

2/42 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

7
4 6 2

183 (7.2)
115 (4.5) 1

77
(3.0)

2
193 (7.6)

TERMINALS
FIELD 1 Process connection, ¼-18 NPT (EN 61 518)
2 Terminal side, analog indicator (optional)
3 External digital indicator (optional)
4 Sealing plug
5 Fixing screw
6 Blanking plug
7 Protective cover for keys
3 8 Electrical connection

SITRANS P pressure transmitters, DS III series for differential pressure and flow, with digital indicator beside control keys, dimensional drawing, dimen-
sions in mm (inch)

SITRANS P pressure transmitters, DS III series for differential pressure


and flow, with digital indicator beside control keys

Siemens FI 01· 2005 2/43


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

2
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS P pressure transmitters, } 7MF 4 4 3 3 - SITRANS P pressure transmitters, } 7MF 4 4 3 3 -
DS III series for differential pressure and flow DS III series for differential pressure and flow
77777 - 7777 77777 - 7777
PN 32/160 (MWP 464/2320 psi) PN 32/160 (MWP 464/2320 psi)
2-wire system 2-wire system
Measuring cell filling Measuring cell Display
cleaning • without (digital indicator hidden, setting: mA) } 1
Silicone oil standard } 1 • with visible digital indicator 6
Inert liquid1) grease-free 3 • with customer-specific digital indicator (setting 7
Measured span as specified, Order code "Y21" required)
PN 32 (MWP 464 psi) } Available ex stock
1 ... 20 mbar 2) (0.0145 ... 0.29 psi) } B Power supply units see "SITRANS I power supply units and input isola-
PN 160 (MWP 2320 psi) tors".
1 ... 60 mbar (0.0145 ... 0.87 psi) } C Included in delivery of the device:
2.5 ... 250 mbar (0.036 ... 3.63 psi) } D • Brief instructions (Leporello)
6 ... 600 mbar (0.087 ... 8.70 psi) } E • CD-ROM with detailed documentation
16 ... 1600 mbar (0.232 ... 23.2 psi) } F • Sealing plug(s) or sealing screw(s) for the process flanges(s)
50 ... 5000 mbar (0.725 ... 72.5 psi) } G 1) For oxygen application, add Order code E10.
0.3 ... 30 bar (4.35 ... 435 psi) } H 2) Not suitable for connection of remote seal
Wetted parts materials 3) Only together with max. spans 250, 1600, 5000 and 30000 mbar
(3.63, 23.2, 72.5 and 435 psi).
(stainless steel process flanges) 4) Without cable gland, with blanking plug
Seal diaphragm Parts of measuring cell 5) With enclosed cable gland EEx ia and blanking plug
Stainless steel Stainless steel } A 6) Not together with type of protection "Explosion-proof"
Hastelloy Stainless steel B
Hastelloy Hastelloy C
Tantalum 3) Tantalum E
Monel 3) Monel H
Gold 3) Gold L
Version for diaphragm seal Y
Process connection
Female thread ¼-18 NPT with flange connection
• Sealing screw opposite process connection
- Mounting thread M10 to DIN 19213 } 0
- Mounting thread 7/16-20 UNF to EN 61518 2
• Vent on side of process flange 2)
- Mounting thread M10 to DIN 19213 4
- Mounting thread 7/16-20 UNF to EN 61518 6
Non-wetted parts materials
Process flange screws Electronics housing
Stainless steel Die-cast aluminium } 2
Stainless steel Stainless steel precision 3
casting
Design
• Standard design 1
• International version, English label inscriptions, } 2
documentation in 5 languages on CD
Explosion protection
• without A
• with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)" B
- "Explosion-proof (EEx d)" 4) D
- "Intrinsic safety and explosion-proof enclosure } P
(EEx ia + EEx d)" 5)
- "n (zone 2)" E
- "Intrinsic safety, explosion-proof enclosure and R
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 5)
• with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 4) NC
Electrical connection / cable inlet
• Screwed gland Pg 13.5 6) A
• Screwed gland M20x1.5 } B
• Screwed gland ½-14 NPT C
• Han 7D plug (plastic housing) incl. mating D
connector 6)

2/44 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

2
Further designs Order code Further designs Order code
Please add "-Z" to Order No. and specify Order code. Please add "-Z" to Order No. and specify Order code.
Pressure transmitter with mounting bracket made of: Oxygen application E10
• Steel A01 (max. 160 bar (2320 psi) with oxygen measurement
• Stainless steel A02 and inert liquid)
O-rings for process flanges Interchanging of process connection side H01
(instead of FPM (Viton)) Vent on side for gas measurements H02
• PTFE (Teflon) A20
Stainless steel process flanges for vertical H03
• FEP (with silicone core, approved for food) A21 differential pressure lines
• FFPM (Kalrez, compound 4079) A22 (not together with K01, K02 and K04) 1)
• NBR (Buna N) A23
Process flange
Plug • Hastelloy K01
• Han 7D (metal, gray) A30 • Monel K02
• Han 8U (instead of Han 7D) A31 • Stainless steel with PVDF insert K04
Sealing screws Max. PN 10 (MWP 145 psi)
¼-18 NPT, with valve in material of process flanges A40 Max. temperature of medium 90 °C (194 °F)

Rating plate inscription


(instead of German) Additional data
• English B11 Measuring range to be set
• French B12 specify in plain text:
• Spanish B13 • with linear characteristic: Y01
• Italian B14 Y01: ... up to ... mbar, bar, kPa, MPa, psi
• with square-root characteristic: Y02
English rating plate (calibration certificate) B21 Y01: ... up to ... mbar, bar, kPa, MPa, psi
Pressure units in inH2O or psi
Measuring point number/identification Y15
Manufacturer's test certificate M C11 max. 16 characters, specify in plain text:
to DIN 55.350, Part 18 and to ISO 8402 Y15: ...........................................
Acceptance test certificate B C12 Measuring point text Y16
to EN 10 204-3.1.B max. 27 characters, specify in plain text:
Factory certificate C14 Y16: ...........................................
to EN 10.204-2.2 Entry of HART address (TAG) Y17
Certificate "Functional Safety (SIL)" C20 max. 27 characters, specify in plain text:
Y17: ...........................................
Setting of upper limit of output signal to 22.0 mA D05
Setting of pressure indicator in pressure units Y21
Acid gas version to NACE D07 specify in plain text (standard setting: mA):
(only together with seal diaphragm made of Hastelloy) Y21: mbar, bar, kPa, MPa, psi, ...
Type of protection IP68 D12 Note:
The following pressure units can be selected:
(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland) bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
Digital indicator along side the input keys D27 *) Reference temperature 20 °C
(only together with the devices 7MF4433-....0-.A.6 or
-.A.7-Z, Y21 or Y22 + Y01) Setting of pressure indicator in non-pressure units Y22 2)+
specify in plain text: Y01 or Y02
Use in or at zone 1D/2D E01 Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
(only together with type of protection "Intrinsic safety (specification of measuring range in pressure units
(EEx ia)" "Y01" or "Y02" is essential, unit with max. 5 characters)
Use at zone 0 E02 Only the settings for "Y01", "Y21", "Y21", "Y22" and "D05"can be made in
(only together with type of protection "Intrinsic safety the factory
(EEx ia)"
1) Not suitable for connection of remote seal
TÜV approval to AD/TRD E06 2) Not together with over-filling safety device for flammable and
non-flammable liquids (Order code "E08")
Overfilling safety device for flammable and E08
non-flammable liquids
(max. PN 32 (MVWP 464 psi), basic device with type of
protection "Intrinsic safety (EEx ia)", to WHG and VbF)

Siemens FI 01· 2005 2/45


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

2
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS P pressure transmitters, DS III series 7MF 4 5 3 3 - SITRANS P pressure transmitters, DS III series 7MF 4 5 3 3 -
for differential pressure and flow for differential pressure and flow
77777 - 7777 77777 - 7777
PN 420 (MWP 6092 psi) PN 420 (MWP 6092 psi)
2-wire system 2-wire system

Measuring cell filling Measuring cell cleaning Display


Silicone oil Standard 1 • without (digital indicator hidden, setting: mA) 1
Measured span • with visible digital indicator 6
2.5 ... 250 mbar (0.036 ... 3.63 psi) D • with customer-specific digital indicator (setting 7
as specified, Order code "Y21" required)
6 ... 600 mbar (0.087 ... 8.70 psi) E
16 ... 1600 mbar (0.232 ... 23.2 psi) F Power supply units see "SITRANS I power supply units and input isola-
50 ... 5000 mbar (0.725 ... 72.5 psi) G tors".
0.3 ... 30 bar (4.35 ... 435 psi) H Scope of delivery: Pressure transmitter as ordered (Instruction Manual is
extra ordering item)
Wetted parts materials
(stainless steel process flanges) 1) Not together with max. span 600 mbar
Seal diaphragm Parts of measuring cell 2) Without cable gland, with blanking plug
3) With enclosed cable gland EEx ia and blanking plug
Stainless steel Stainless steel A
4) Not together with type of protection "Explosion-proof"
Hastelloy Stainless steel B
Gold 1) Gold L
Process connection
Female thread ¼-18 NPT with flange connection
• Sealing screw opposite process connection
- Mounting thread M12 to DIN 19213 1
- Mounting thread 7/16-20 UNF to 3
EN 61518
• Vent on side of process flanges
- Mounting thread M12 to DIN 19213 5
- Mounting thread 7/16-20 UNF to 7
EN 61518
Non-wetted parts materials
Process flange screws Electronics housing
Stainless steel Die-cast aluminium 2
Stainless steel Stainless steel precision 3
casting
Design
• Standard design 1
• International version, English label inscriptions, 2
documentation in 5 languages on CD
Explosion protection
• without A
• with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)" B
- "Explosion-proof (EEx d)" 2) D
- "Intrinsic safety and explosion-proof enclosure P
(EEx ia + EEx d)" 3)
- "n (zone 2)" E
- "Intrinsic safety, explosion-proof enclosure and R
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 3)
• with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 2), NC
max. PN 360
Electrical connection / cable inlet
• Screwed gland Pg 13.5 4) A
• Screwed gland M20x1.5 B
• Screwed gland ½-14 NPT C
• Han 7D plug (plastic housing) incl. mating D
connector 4)

2/46 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

2
Further designs Order code Further designs Order code
Please add "-Z" to Order No. and specify Please add "-Z" to Order No. and specify
Order code. Order code.
Pressure transmitter with mounting bracket made of: Additional data
• Steel A01 Measuring range to be set
• Stainless steel A02 specify in plain text:
O-rings for process flanges • with linear characteristic: Y01
(instead of FPM (Viton)) Y01: ... up to ... mbar, bar, kPa, MPa, psi
• PTFE (Teflon) A20 • with square-root characteristic: Y02
• FEP (with silicone core, approved for food) A21 Y01: ... up to ... mbar, bar, kPa, MPa, psi
• FFPM (Kalrez, compound 4079) A22 Measuring point number/identification Y15
• NBR (Buna N) A23 max. 16 characters, specify in plain text:
Y15: ...........................................
Plug
• Han 7D (metal, gray) A30 Measuring point text Y16
• Han 8U (instead of Han 7D) A31 max. 27 characters, specify in plain text:
Y16: ...........................................
Sealing screws A40
¼-18 NPT, with valve in material of process flanges Entry of HART address (TAG) Y17
max. 27 characters, specify in plain text:
Rating plate inscription Y17: ...........................................
(instead of German)
Setting of pressure indicator in pressure units Y21
• English B11
specify in plain text (standard setting: mA):
• French B12 Y21: mbar, bar, kPa, MPa, psi, ...
• Spanish B13 Note:
• Italian B14 The following pressure units can be selected:
English rating plate B21 bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
Pressure units in inH2O or psi psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 °C
Manufacturer's test certificate M C11
(calibration certificate) Setting of pressure indicator in non-pressure units Y22 +
specify in plain text: Y01 or Y02
to DIN 55350, Part 18 and to ISO 8402
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
Acceptance test certificate B C12 (specification of measuring range in pressure units
to EN 10204-3.1.B "Y01" or "Y02" is essential, unit with max. 5 characters)
Factory certificate C14 Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
to EN 10204-2.2 factory
Certificate "Functional Safety (SIL)" C20
Setting of upper limit of output signal to D05
22.0 mA
Acid gas version to NACE D07
(only together with seal diaphragm made of Hastelloy)
Type of protection IP68 D12
(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)
Digital indicator along side the input keys D27
(only together with the devices 7MF4533-....2-.A.6 or
-.A.7-Z, Y21 or Y22 + Y01)
Use in or at zone 1D/2D E01
(only together with type of protection "Intrinsic safety
(EEx ia)"
Use at zone 0 E02
(only together with type of protection "Intrinsic safety
(EEx ia)"
Interchanging of process connection side H01
Stainless steel process flanges for vertical H03
differential pressure lines

Siemens FI 01· 2005 2/47


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level

■ Technical specifications
2
Measuring cell with silicone oil filling
- High-pressure side pabs ≥ 1 bar: -40 ... +175 °C
SITRANS P pressure transmitters, DS III series, for level (-40 ... +347 °F)
Input pabs < 1 bar: -40 ... +80 °C
Measured variable Level (-40 ... +176 °F)

Span Maximum working pressure - Low-pressure side -40 ... +100 °C (-40 ... +212 °F)
(nominal pressure) -20 ... +60 °C (-4 ... +140 °F) in
conjunction with dust explosion
• 25 ... 250 mbar (0.36 ... 3.63 psi) See "Mounting flange" protection
• 25 ... 600 mbar (0.36 ... 8.7 psi) Design
• 53 ... 1600 mbar (0.77 ...23.2 psi) Weight (without options)
• 160 ... 5000 mbar • To DIN (pressure transmitter with ≈ 11 ... 13 kg (≈ 24.2 ... 28.7 lb)
(2.32 ... 72.5 psi) mounting flange, without tube)
Lower measuring limit (measuring -100% of max. span or 30 mbar • To ANSI (pressure transmitter with ≈ 11 ... 18 kg (≈ 24.2 ... 39.7 lb)
cell with silicone oil filling) (0.435 psi) abs., depending on mounting flange, without tube)
mounting flange
Wetted parts materials
Upper measuring limit 100% of max. span
• High-pressure side: Seal dia- Stainless steel, mat. No.
Output phragm of mounting flange 1.4404/316L,
Output signal 4 ... 20 mA Monel 400, mat. No. 2.4360,
Hastelloy B2, mat. No. 2.4617,
Measuring accuracy Hastelloy C276, mat. No. 2.4819,
Reference conditions Increasing characteristic Hastelloy C4, mat. No. 2.4610,
Start-of-scale value 0 bar tantalum, PTFE, ECTFE
Stainless steel seal diaphragm Measuring cell filling Silicone oil
Mounting flange without tube
Silicone oil filling Process connection
Room temperature (25 °C (77 °F)) • High-pressure side Flange to DIN and ANSI
r: Span ratio
(r = max. span / set span) • Low-pressure side Female thread ¼-18 NPT and
flange connection to DIN 19213
Error in measurement and fixed- with mounting thread M10 or
point setting (including hysteresis 7/ -20 UNF to EN 61518
16
and repeatability)
Power supply UH
• Linear characteristic
Terminal voltage on pressure trans- 10.5 ... 45 V DC
- r ≤ 10 ≤ 0.15% mitter 10.5 ... 30 V DC in intrinsically-
- 10 < r ≤ 30 ≤ 0.3% safe mode
- 30 < r ≤ 100 (0.0075 ⋅ r + 0.075)% Certificates and approvals
Influence of ambient temperature Classification according to pressure For gases of fluid group 1 and
equipment directive liquids of fluid group 1; complies
• With -10 ... +60 °C (14 ... 140 °F) (DRGL 97/23/EC) with requirements of article 3,
- 250-mbar (3.63 psi) measuring ≤ (0.5 ⋅ r + 0.2)% (0.4 instead of paragraph 3 (sound engineering
cell 0.2 with 10 < r ≤ 30) practice)

- 600-mbar (8.7 psi) measuring ≤ (0.3 ⋅ r + 0.2)% (0.4 instead of Explosion protection
cell 0.2 with 10 < r ≤ 30)
• Intrinsic safety "i" PTB 99 ATEX 2122
- 1,600 and 5,000 mbar (23.2 and ≤ (0.25 ⋅ r + 0.2)% (0.4 instead of
0.2 with 10 < r ≤ 30) - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6
72.5 psi) measuring cells
- Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
• With -40 ... -10 °C and re temperature class T4;
+60 °C ... +85 °C -40 ... +70 °C (-40 ... +158 °F)
(-40 ... +14 and 140 ... 185 °F) temperature class T5;
- 250-mbar (3.63 psi) measuring ≤ (0.25 ⋅ r +0.15)% / 10 K -40 ... +60 °C (-40 ... +140 °F)
cell (≤ (0.25 ⋅ r +0.15)% / 18 °F) temperature class T6
(Twice the value for 10 < r ≤ 30) - Connection To certified intrinsically-safe cir-
- 600-mbar (8.7 psi) measuring ≤ (0.15 ⋅ r +0.15)% / 10 K cuits with maximum values:
cell (≤ (0.15 ⋅ r +0.15)% / 18 °F) Ui = 30 V, Ii = 100 mA,
(Twice the value for 10 < r ≤ 30) Pi = 750 mW; Ri = 300 Ω

- 1,600 and 5,000 mbar (23.2 and ≤ (0.12 ⋅ r +0.15)% / 10 K - Effective internal inductance/ca- Li = 0.4 mH, Ci = 6 nF
72.5 psi) measuring cells (≤ (0.12 ⋅ r +0.15)% / 18 °F) pacitance
(Twice the value for 10 < r ≤ 30) • Explosion-proof "d" PTB 99 ATEX 1160
Rated conditions - Identification Ex II 1/2 G EEx d IIC T4/T6
Degree of protection (to EN 60529) IP65 - Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F)
Process temperature Note: Note the assignment of the re temperature class T4;
max. permissible operating tem- -40 ... +60 °C (-40 ... +140 °F)
perature to the max. permissible temperature class T6
operating pressure of the respec- - Connection To circuits with values:
tive flange connection! UH = 10.5 ... 45 V DC

2/48 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level

2
• Dust explosion protection for PTB 01 ATEX 2055 Mounting flange
zone 20
Nom. diam. Nom. press.
- Identification Ex II 1 D IP65 T 120 °C
Ex II 1/2 D IP65 T 120 °C • To EN 1092-1
- Permissible ambient temperatu- -40 ... +85 °C (-40 ... +185 °F) - DN 80 PN 40
re - DN 100 PN 16
- Max.surface temperature 120 °C (248 °F) PN 40
- Connection To certified intrinsically-safe cir- • To ASME B16.5
cuits with maximum values: - 3 inch class 150
Ui = 30 V, Ii = 100 mA, class 300
Pi = 750 mW, Ri = 300 Ω
- 4 inch class 150
- Effective internal inductance/ca- Li = 0.4 mH, Ci = 6 nF class 300
pacitance
• Dust explosion protection for zone PTB 01 ATEX 2055
21/22
- Identification Ex II 2 D IP65 T 120 °C
- Connection To circuits with values:
UH = 10.5 ... 45 V DC;
Pmax = 1.2 W
• Type of protection "n" (zone 2) TÜV 01 ATEX 1696 X
- Identification Ex II 3 G EEx nA L IIC T4/T5/T6
• Explosion protection to FM Certificate of Compliance
3008490
- Identification (XP/DIP) or (IS); CL I, DIV 1, GP ABCD T4...T6;
(NI) CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III
• Explosion protection to CSA Certificate of Compliance
1153651
- Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

Siemens FI 01· 2005 2/49


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level

■ Dimensional drawings
2
approx. 30 (1.18)5)
185
15
100 (3.94) 138 (5.4) (0.6)
6 50
(1.97) 69 (2.72)

2
3
51)

165 (6.5)
L 77 (3)4)
9

d4
d5

D
54 (2.1) 108 (4.25) k
3 1

Space for rotation


of housing
nxd 2
b
approx. 96 (3.78)
f

1 Process connection of low pressure side ¼-18 NPT (EN 61 518)


2 Blanking plug
3 Electrical connection:
screwed gland Pg 13.5 (adapter) 2) 3), 6
screwed gland M20x1.5, screwed gland ½-14 NPT or 51)
Han 7D/ Han 8U plug 2) 3) 41)
4 Terminal side
5 Electronics side, digital display (longer overall length for cover with window)
6 Protective cover over keys
8 Sealing screw with valve (option)
9 Screw cover safety bracket (only for type of protection "Explosion-proof enclosure",
not shown in the drawing)

1) Allow approx. 20 mm (0.79 inch) thread length in addition


2) Not with type of protection "Explosion-proof enclosure"
3) Not with type of protection "FM + CSA [is + xp]"
4) 92 mm (3.62 inch) for minimum distance to permit rotation without indicator
5) Approx. 45 mm (1.77 inch) for Pg 13.5 with adapter
SITRANS P pressure transmitters, DS III series for level, including mounting flange, dimensional drawing, dimensions in mm (inch)
Connection to EN 1092-1
Nom. diam. Nom. press. b D d d2 d4 d5 dM f k n L
mm mm mm mm mm mm mm mm mm mm mm
DN 80 PN 40 24 200 90 18 138 76 72 1) 2 160 8 0, 50, 100,
150 or 200
DN 100 PN 40 20 220 115 18 158 94 89 2 180 8
PN 40 24 235 115 22 162 94 89 2 190 8

Connection to ASME B16.5


Nom. diam. Nom. press. b D d2 d4 d5 dM f k n L
lb/sq.in. inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)
3 inch 150 0.94 7.5 0.75 5 3 2.81 1) 0.06 6 4 0, 2, 3.94,
(23.8) (190.5) (19.0) (127) (76) (72) (1.6) (152.4) 5.94 or 7.87
(0, 50, 100,
300 1.12 8.25 0.87 5 3 2.81 1) 0.06 6.69 8 150 or 200)
(28.6) (209.5) (22.2) (127) (76) (72) (1.6) (168.3)
4 inch 150 0.94 9 0.75 6,19 3.69 3.5 0.06 7.5 8
(23.8) (228.5) (19.0) (157.2) (94) (89) (1.6) (190.5)
300 1.25 10 0.87 6,19 3.69 3.5 0.06 7.88 8
(31.7) (254) (22.2) (157.2) (94) (89) (1.6) (200)

d: Internal diameter of gasket to DIN 2690 1) 89 mm = 3½ inch with tube length L = 0.


dM: Effective diaphragm diameter

2/50 Siemens FI 01· 2005


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level

2
Selection and Ordering data Order No. Further designs Order code
SITRANS P pressure transmitters, DS III series 7MF 4 6 3 3 - Please add "-Z" to Order No. and specify Order code.
for level
O-rings for process flanges
2-wire system 77 Y77 - 7777 (instead of FPM (Viton))
Measuring cell filling Measuring cell cleaning • PTFE (Teflon) A20
Silicone oil Standard 1 • FEP (with silicone core, approved for food) A21
• FFPM (Kalrez, compound 4079) A22
Measured span
• NBR (Buna N) A23
25 ... 250 mbar (0.363 ... 3.63 psi) D
25 ... 600 mbar (0.363 ... 8.70 psi) E Plug
53 ... 1600 mbar (0.77 ... 23.2 psi) F • Han 7D (metal, gray) A30
0.16 ... 5 bar (2.32 ... 72.5 psi) G • Han 8U (instead of Han 7D) A31
Process connection of low-pressure side Sealing screws A40
Female thread ¼-18 NPT with flange connection ¼-18 NPT, with valve in material of process flanges
• Mounting thread M10 to DIN 19213 0 Rating plate inscription
• Mounting thread 7/16-20 UNF to EN 61518 2 (instead of German)
Non-wetted parts materials • English B11
Process flange screws Electronics housing • French B12
• Spanish B13
Stainless steel Die-cast aluminium 2
• Italian B14
Stainless steel Stainless steel precision 3
casting English rating plate B21
Design Pressure units in inH2O or psi
• Standard design 1 Manufacturer's test certificate M C11
• International version, English label inscriptions, 2 (calibration certificate)
documentation in 5 languages on CD to DIN 55350, Part 18 and to ISO 8402
Explosion protection Acceptance test certificate B C12
• without A to EN 10204-3.1.B
• with ATEX, Type of protection: Factory certificate C14
- "Intrinsic safety (EEx ia)" B to EN 10204-2.2
- "Explosion-proof (EEx d)" 1) D
- "Intrinsic safety and explosion-proof enclosure P Certificate "Functional Safety (SIL)" C20
(EEx ia + EEx d)" 2) Setting of upper limit of output signal to 22.0 mA D05
- "n (zone 2)" E
Type of protection IP68 D12
- "Intrinsic safety, explosion-proof enclosure and R
dust explosion protection (EEx ia + EEx d + (not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)
zone 1D/2D)" 2)
• with FM + CSA, Type of protection: Use in or at zone 1D/2D E01
- "Intrinsic safety and explosion-proof (is + xp)" 1) NC (only together with type of protection "Intrinsic safety
(EEx ia)"
Electrical connection / cable inlet
Use at zone 0 E02
• Screwed gland Pg 13.5 3) A
(only together with type of protection "Intrinsic safety
• Screwed gland M20x1.5 B (EEx ia)"
• Screwed gland ½-14 NPT C
• Han 7D plug (plastic housing) incl. mating D Overfilling safety device for flammable and E08
connector 3) non-flammable liquids
(max. PN 32, only together with type of protection
Display "Intrinsic safety (EEx ia)"), to WHG and VbF
• without (digital indicator hidden, setting: mA) 1
Interchanging of process connection side H01
• with visible digital indicator 6
• with customer-specific digital indicator (setting 7
as specified, Order code "Y21" required)
Ordering information:
1st order item: Pressure transmitter 7MF4633-...
2nd order item: Mounting flange 7MF4912-3...
Example of ordering:
Item line 1: 7MF4633-1EY20-1AA1-Z
B line: Y01
C line: Y01: 80 to 143 mbar (1.16 to 2.1 psi)
Item line 2: 7MF4912-3GE01
Power supply units see "SITRANS I power supply units and input isola-
tors".
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing plug(s) or sealing screw(s) for the process flanges(s)

1) Without cable gland, with blanking plug


2) With enclosed cable gland EEx ia and blanking plug
3) Not together with type of protection "Explosion-proof"

Siemens FI 01· 2005 2/51


SITRANS P measuring instruments for pressure
Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level

2
Further designs Order code Selection and Ordering data Order No. Ord. code
Please add "-Z" to Order No. and specify Order code. Mounting flange 7MF 4 9 1 2 -
Additional data directly fitted to pressure transmitter 3 7777 777
SITRANS P (converter part) for level,
Measuring range to be set Y01 for DS III series
specify in plain text:
Y01: ... up to ... mbar, bar, kPa, MPa, psi Wetted parts materials
• Stainless steel 316L A
Measuring point number/identification Y15
- Coated with PFA 1) D
max. 16 characters, specify in plain text:
Y15: ........................................... - Coated with PTFE 1) E0
- Coated with ECTFE 1) F
Measuring point text Y16
max. 27 characters, specify in plain text: • Monel 400, mat. No. 2.4360 G
Y16: ........................................... • Hastelloy B2, mat. No. 2.4617 H
• Hastelloy C276, mat. No. 2.4819 J
Entry of HART address (TAG) Y17
• Hastelloy C4, mat. No. 2.4610 U
max. 8 characters, specify in plain text:
Y17: ........................................... • Tantalum K

Setting of pressure indicator in pressure units Y21 Other version Z K1Y


Add Order code and plain text:
specify in plain text (standard setting: mA): Wetted parts materials: ...
Y21: mbar, bar, kPa, MPa, psi, ... Sealing face, see "Technical data"
Note:
The following pressure units can be selected: Tube length
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, • without 0
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or % • 50 mm (1.97 inch) 1
*) Reference temperature 20 °C • 100 mm (3.94 inch) 2
Setting of pressure indicator in non-pressure units Y22 1)+ Y01 • 150 mm (5.90 inch) 3
specify in plain text: • 200 mm (7.87 inch) 4
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... Other version: 9 L1Y
(specification of measuring range in pressure units Add Order code and plain text:
"Y01" is essential, unit with max. 5 characters) Tube length: ...
Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the Filling liquid
factory • Silicone oil M5 1
• Silicone oil M50 2
1) Not together with over-filling safety device for flammable and
non-flammable liquids (Order code "E08") • High-temperature oil 3
• Halocarbon oil (for O2 measurements) 4
Selection and Ordering data Order No. Ord. code • Vegetable 5
• Glycerin / water2) 6
Mounting flange 7MF 4 9 1 2 -
Other version 9 M1 Y
directly fitted to pressure transmitter 3 7777 777
Add Order code and plain text:
SITRANS P (converter part) for level,
Filling liquid: ...
for DS III series
Ordering example see previous page
Connection to EN 1092-1
Nom. diam. Nom. press. 1) For vacuum on request
DN 80 PN 40 D 2) Not suitable for use in low-pressure range
DN 100 PN 16 G
PN 40 H Further designs Order code
Connection to ASME B16.5 Please add "-Z" to Order No. and specify Order code.
Nom. diam. Nom. press. Spark arrestor A01
3 inch Class 150 Q for mounting on zone 0 (including documentation)
Class 300 R
Manufacturer's test certificate M C11
4 inch Class 150 T
to DIN 55.350, Part 18 and to ISO 8402
Class 300 U
Other version Acceptance test certificate B C12
Z J1Y
Add Order code and plain text: to EN 10 204-3.1B
Nominal diameter: ...; Nominal pressure: ...
Vacuum-proof design V04
(for use in low-pressure range)
Calculation of span of associated pressure Y05
transmitter
(enclose filled-in questionnaire with order)
Note:
Suffix "Y01" required with pressure transmitter

2/52 Siemens FI 01· 2005