Features
■ Fire rated
■ Virtually odourless resin with a high flash point
■ Good wetting of concrete by the adhesive: high bond strength
■ Capsule contains graded quartz crystals that roughen core drilled holes
■ Can be used in dry or damp base material
■ No expansion force in base material
■ Good resistance to chemicals
■ Capsules won’t drop out of overhead holes
■ Wide installation temperature range -5ºC to +40ºC
■ Components in capsule are in correct measured amounts that
ensures reliable mixing and no air pockets in hole
■ Quick curing
■ Tough, flexible capsule
Technical data
For external thread HAS-E For internal thread HIS-N/HIS-RN
Hole Designation Hole Nrec Vrec Designation Hole Nrec Vrec Foil capsule size
depth, threaded diameter, kN kN internally diameter, kN kN Designation
h1 (mm) rod d1 (mm) fc,cyl=20MPa fc,cyl=20MPa threaded d1 (mm) fc,cyl=20MPa fc,cyl=20MPa HVU
80 HAS M8 10 7.8 5.6 — — — — HVU M8 x 80
90 HAS M10 12 11.8 9.0 HIS-N M8 14 8.7 6.3 HVU M10 x 90
110 HAS M12 14 17.0 13.1 HIS-N M10 18 13.8 9.9 HVU M12 x 110
125 HAS M16 18 24.8 24.7 HIS-N M12 22 20.1 14.5 HVU M16 x 125
170 HAS M20 24 44.9 38.6 HIS-N M16 28 37.4 26.9 HVU M20 x 170
210 HAS M24 28 64.7 55.6 HIS-N M20 32 58.6 42.0 HVU M24 x 210
270 HAS M30 35 104.0 142.4 — — — — HVU M30 x 270
330 HAS M36 40 145.2 208.2 — — — — HVU M36 x 330
Nrec = Recommended working load in tension Vrec = Recommended working load in shear fc,cyl=20MPa concrete
For stainless steel, please contact your local Hilti Engineer or call 131 292
Curing time
Base material temperature ≥+20°C +10°C ≥0°C ≥– 5°C
Time between setting and loading 20 min. 30 min. 1 hour 5 hours
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Item Ordering Anchor Hole Hole Max Fasten. Tighten. Package Price
no. designation length dia. Depth Thickness Torque contents per
(Nm)
Steel (Grade 5.8 - 500 MPa) zinc plated to min. 5 microns
332219 HAS-E M8 x 80/14 106mm 10mm 80mm 14mm 15 20 100
332220 HAS-E M10 x 90/21 125mm 12mm 90mm 21mm 30 20 100
332221 HAS-E M12 x 110/28 153mm 14mm 110mm 28mm 50 20 100
332222 HAS-E M16 x 125/38 182mm 18mm 125mm 38mm 100 20 100
332223 HAS-E M20 x 170/48 240mm 24mm 170mm 48mm 160 10 100
332224 HAS-E M24 x 210/54 290mm 28mm 210mm 54mm 240 10 100
Steel (Grade 5.8, - 500 MPa) hot dipped galvanised to min. 40 microns
333143 HAS-E-F M8 x 80/14 106mm 10mm 80mm 14mm 15 20 100
333145 HAS-E-F M10 x 90/21 125mm 12mm 90mm 21mm 30 20 100
333148 HAS-E-F M12 x 110/28 153mm 14mm 110mm 28mm 50 20 100
333153 HAS-E-F M16 x 125/38 182mm 18mm 125mm 38mm 100 20 100
333158 HAS-E-F M20 x 170/48 240mm 24mm 170mm 48mm 160 10 100
333163 HAS-E-F M24 x 210/54 290mm 28mm 210mm 54mm 240 10 100
▲ 333165 HAS-E-F M30 x 270/70 (grade 8.8) 380mm 35mm 270mm 70mm 300 4 100
▲ 333167 HAS-E-F M36 x 330/90 (grade 8.8) 460mm 40mm 330mm 90mm 1500 2 100
For assistance in anchor design contact your local Hilti Engineer or call 131 292
1/2" DRIVE SOCKET (can also be used for double nut setting of threaded rods)
060186 For M8 rod
060187 For M10 rod
060188 For M12 rod
060189 For M16 rod
3/4" DRIVE SOCKET (can also be used for double nut setting of threaded rods)
001958 For M12 rod
060190 For M16 rod
060191 For M20 rod
060192 For M24 rod
3092011 For M30 rod
3092009 For M36 rod
Connection shafts
Connection shafts can be used with appropriate drive socket for setting HAS-E, HAS-E-F,
HAS-E-R anchor rods, or with HIS-S setting tools and drive socket for setting HIS-N, HIS-RN.
Item Ordering For For Use
No. Designation Connection in Rotary
thread Hammer
032220 TE-C connection shaft 1/2” M 8, M 10, M 12, M 16 TE 7-C, TE 16-C, TE 16-M*
332169 TE-T connection shaft 3/4” M 12, M 16, M 20, M 24, M 30, M 36 TE 35-C
032221 TE-Y connection shaft 3/4” M 12, M 16, M 20, M 24, M 30, M 36 TE 56, TE 56-ATC, TE 76-ATC
* with TE-C chuck
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Technical data
For external thread HAS-E For internal thread HIS-N
Hole Designation Hole Nrec Vrec Hole Designation Hole Nrec Vrec
depth, threaded diameter, kN kN depth, internally diameter, kN kN
h1 (mm) rod d1 (mm) fc,cyl=20MPa fc,cyl=20MPa h1 (mm) threaded d1 (mm) fc,cyl=20MPa fc,cyl=20MPa
80 HAS M8 10 6.0 5.6 — — — —
90 HAS M10 12 8.0 9.0 95 HIS-N M8 14 8.2 6.3
110 HAS M12 14 12.0 13.1 115 HIS-N M10 18 12.3 9.9
125 HAS M16 18 15.3 24.7 130 HIS-N M12 22 15.6 14.5
170 HAS M20 24 26.0 38.6 175 HIS-N M16 28 26.9 26.9
210 HAS M24 28 32.4 55.6 210 HIS-N M20 32 32.2 42.0
Nrec = Recommended working load in tension Vrec = Recommended working load in shear fc,cyl=20MPa concrete
For stainless steel, please contact your local Hilti Engineer or call 131 292
Curing time
Base material temperature ≥+20°C +5°C ≥0°C ≥– 5°C
Time between setting and loading 50 min. 1.5 hours 3 hour 6 hours
330ml/500ml/1400ml foil pack
Steel (Grade 5.8, - 500 MPa) hot dipped galvanised to min. 40 microns
333143 HAS-E-F M8 x 80/14 106mm 10mm 82mm 14mm 15 20 100
333145 HAS-E-F M10 x 90/21 125mm 12mm 92mm 21mm 30 20 100
333148 HAS-E-F M12 x 110/28 153mm 14mm 115mm 28mm 50 20 100
333153 HAS-E-F M16 x 125/38 182mm 18mm 130mm 38mm 100 20 100
333158 HAS-E-F M20 x 170/48 240mm 24mm 175mm 48mm 160 10 100
333163 HAS-E-F M24 x 210/54 290mm 28mm 215mm 54mm 240 10 100
For assistance in anchor design contact your local Hilti Engineer or call 131 292
For assistance in anchor design contact your local Hilti Engineer or call 131 292
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Features
■ Comprehensive sets of accessories for maximising your HIT
performances and productivity gain
■ Great opportunity to customise your HIT installation equipment
according to your application needs
Item Ordering
no. designation
For assistance in anchor design contact your local Hilti Engineer or call 131 292
ED 3500 dispenser
Application
• Injection of Hilti HIT adhesive mortar for fastening anchor rods and
rebars in concrete, masonry and stone
Technical data
Dispensing time* 70 sec
Dispenser piston force 3000 N
Battery capacity: SFB 126 (12 V, 3.0 Ah NiMH) 75 foil packs
Features
■ Suitable for 330ml and 500ml tubes
■ Ideal for use in difficult to reach areas and repetitive applications
■ Very easy to use—allows mortar to be dispensed quickly and easily
■ Increase job site productivity
■ Powerful tool with the pressure of a pneumatic system but without
the need for a heavy compressor
■ Easy dispensing capability in cold temperatures and deep holes
ED 3500 dispenser
Item no. Ordering designation
For assistance in anchor design contact your local Hilti Engineer or call 131 292
MD 2000 / 2500
dispenser HIT-BD 2000
dispenser
Item Ordering
no. designation
HIT mixers
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Technical data
Recommended load, (kN), non-cracked concrete, fc = 20 MPa
Extract from application conditions in Hilti fastening technology manual; please observe
“special regulations” when designing and making anchor fastenings.
Anchor size HSL-3 M8 HSL-3 M10 HSL-3 M12 HSL-3 M16 HSL-3 M20 HSL-3 M24
HSL-3 B M12 HSL-3 B M16 HSL-3 B M20 HSL-3 B M24 Features
Tensile load, Nrec. (kN) 11.1 14.0 17.2 24.0 33.5 44.1 ■ Integrated plastic section:
Shear load, Vrec. (kN) 17.8. 28.1 41.0 57.8 81.1 101.4 - to avoid turning in the hole
- to telescope and pull down
tightly (bridging of gaps)
■ The bolt can be retorqued
■ Fire rated
■ Indicator nut version, HSL-3-B, with red cap nut which breaks off
when anchor correctly set to reveal green cap nut
■ Immediate keying and friction hold
■ High pull out and lateral shear load values
■ Safe and reliable fastening thanks to torque controlled force
expansion
■ Steel strength 8.8 with rolled thread, zinc plated to 5 microns thick
Item Ordering Hole Min. Hole Max Fasten. Tighten. Package Price
no. designation dia. Depth Thickness Torque contents per
(Nm)
Item Ordering Hole Min. Hole Max Fasten. Tighten. Package Price
no. designation dia. Depth Thickness Torque contents per
(Nm)
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Safe rings
Material
Three types of Safering are available:
Hot-dip galvanised
Drop-forged from Grade 8.8. high tensile steel
White nylon coated
Hot-dip galvanised Safe ring with a nylon coating for an
attractive appearance
Stainless Steel
Drop-forged from premium quality stainless steel and then
electro-polished. Required for exterior use
Program
Thread Thread
Diam.mm Length.mm
Saferings material
Stainless steel, white coated,
Galvanised, NW 35x16 plastic washer 12 85
Minimum spacing and edge distance Smin and Cmin=200mm
Specifications
Hilti Saferings and fixing systems are designed to comply with the
requirements of BS 5845, AS 1891, AS 2317, AS 4626 & AS 4488.2, the
standard specification for permanent anchors used in association with
industrial safety belts and harnesses. As a quality check each Safe ring is
proof loaded to 10kN after manufacture. After installation each anchorage
must be subjected to a mandatory test in which the anchors are
proof loaded to a force of 7.5kN as per AS/NZS 1891.4, or 6 kN as per
AS/NZS 4488.2
Ringbolts
Item Ordering Hole Hole Package Price
no. designation dia. Depth contents per
HSL-3 system
371781 HSL-3 M12/25 18mm 125mm 20 100
371808 HSL-3-B M12/25 18mm 125mm 20 100
067946 HSL-G-R M12 component set (S/S) 18mm 125mm 1 100
Chemical injection technique solution available on request.
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Note: These values are given for single anchors without influence from neighbouring anchors or concrete edges.
Consult the Hilti Fastening Technology Manual for more detailed design.
For assistance in anchor design contact your local Hilti Engineer or call 131 292
TO SUIT TE 35-C *
332089 TE-C-HDA-B 20 x 100 20-M10 x 100 — 1
332091 TE-C-HDA-B 22 x 125 22-M12 x 125 — 1
332090 TE-C-HDA-B 20 x 120 — 20-M10 x 100/20 1
332092 TE-C-HDA-B 22 x 155 — 22-M12 x 125/30 1
332093 TE-C-HDA-B 22 x 175 — 22-M12 x 125/50 1
TO SUIT TE 56-ATC
237449 TE-Y-HDA-B 20 x 100 20-M10 x 100/20 — 1
237450 TE-Y-HDA-B 20 x 120 — 20-M10 x 100/20 1
237451 TE-Y-HDA-B 22 x 125 22-M12 x 125/30, 22-M12 x 125/50 — 1
237452 TE-Y-HDA-B 22 x 155 — 22-M12 x 125/30 1
237453 TE-Y-HDA-B 22 x 175 — 22-M12 x 125/50 1
TO SUIT TE 76-ATC
332097 TE-Y-HDA-B 30 x 190 30-M16 x 190 — 1
332098 TE-Y-HDA-B 30 x 230 — 30-M16 x 190/40 1
332099 TE-Y-HDA-B 30 x 250 — 30-M16 x 190/60 1
339271 TE-Y-HDA-B 37 x 300 — 37-M20 x 250/50 1
339272 TE-Y-HDA-B 37 x 350 — 37-M20 x 250/100 1
339270 TE-Y-HDA-B 37 x 250 37-M20 x 250 — 1
*With TE-C chuck
Setting tools
To expand the anchor correctly
Item Ordering For For Price
no. designation HDA-P HDA-T per
TO SUIT TE 35-C *
331843 TE-C-HDA-ST 20-M10 20-M10 x 100 20-M10 x 100 1
331844 TE-C-HDA-ST 22-M12 22-M12 x 125 22-M12 x 125 1
TO SUIT TE 56-ATC
287133 TE-Y-HDA-ST 20-M10 20-M10 x 100 20-M10 x 100 1
287134 TE-Y-HDA-ST 22-M12 22-M12 x 125 22-M12 x 125 1
TO SUIT TE 76-ATC
331846 TE-Y-HDA-ST 30-M16 30-M16 x 190 30-M16 x 190 1
339269 TE-Y-HDA-ST 37-M20 37-M20 x 250 37-M20 x 250 1
*With TE-C chuck
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Technical data
Recommended load, (kN), non-cracked concrete, fc,cyl = 20 MPa
Features
HSC-I HSC-IR ■ Shallow embedment depth, avoids hitting rebars
Anchor size M8x40 M10x50 M10x60 M12x60 M8x40 M10x50 M10x60 M12x60 ■ Anchor hole drilled as usual, without undercutting
Tensile load, Nrec. 6.1 8.5 11.1 11.1 6.1 8.5 11.1 11.1 ■ Automatic undercutting by anchor when anchor sleeve is
Shear load, Vrec. 12.6 17.1 35.4 56 30.9 38.1 66.6 100 driven over anchor stud
If used in cracked concrete, multiply the tensile load by the factor 0.7. ■ Fire rated
HSC-I internally threaded, zinc plated; HSC-IR internally threaded, stainless steel ■ Maximum safety due to the undercut and keying action
HSC-I HSC-IR ■ Small spacings between fastening and edges
Anchor size M8x40 M10x40 M12x60 M8x40 M10x40 M12x60 ■ Fast setting: no specials undercutting tool required
Tensile load, Nrec. 6.1 6.1 11.1 6.1 6.1 11.1 ■ For use anywhere, in the compression or cracked tension zone
Shear load, Vrec. 8.3 13.3 19.3 5.9 9.3 13.5 of concrete
If used in cracked concrete, multiply the tensile load by the factor 0.7.
HSC-A externally threaded, zinc plated; HSC-AR externally threaded, stainless steel
For assistance in anchor design contact your local Hilti Engineer or call 131 292
For assistance in anchor design contact your local Hilti Engineer or call 131 292
For assistance in anchor design contact your local Hilti Engineer or call 131 292
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Applications
■ For the medium load range; fastenings with bolts and threaded rods for
plumbing, heating, air-conditioning and ventilation installations, pipe
suspension, air ducts etc., for securing channels, rails, plates, brackets
and suspended ceilings
■ Use in concrete and hard natural stone Features
■ A flared end for accurate setting flush with the surface, independent
Technical data
of the hole depth; ideal for repetitive fastening with threaded rods of
Recommended load, (kN), non-cracked concrete, fc,cyl ≥ 20 MPa
equal length
Extract from application conditions in Hilti fastening technology manual; Please
observe “special regulations” when designing and making anchor fastenings. ■ No damage to the thread when driving in the anchor; easy to expand
■ Visual verification of full expansion
Standard anchorage depth:
■ Anchor and setting tools form a matched system
Anchor size M6 M8 M10: 3/8" M12 M16 M20
1 ■ Manual or mechanically assisted setting tools
/4" 5
/16" x30 x40 1
/2" 5
/8" 3
/4"
■ Complete expansion after a few hammer blows
Tensile load, Nrec. 2.1 3.3 3.3 5.1 7.1 12.6 17.2
■ Fire rated
Shear load, Vrec. 2.1 3.9 4.2 4.6 8.1 12.5 19.9
For assistance in anchor design contact your local Hilti Engineer or call 131 292
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Item Ordering Hole Min. Hole Thread Max Fasten. Package Price
no. designation dia. Depth Size Thickness contents per
Item Ordering Hole Min. Hole Thread Max Fasten. Package Price
no. designation dia. Depth Size Thickness contents per
HLC eyebolt
Item Ordering Hole Min. Hole Thread Max Fasten. Package Price
no. designation dia. Depth Size Thickness contents per
For assistance in anchor design contact your local Hilti Engineer or call 131 292
HT10
With countersunk head screw (set with Posi-Drive No.3)
Item Ordering Hole Hole Anchor Package Price
no. designation dia. Depth Length contents per
Nrec. = Tensile working load (static) in concrete fc,cyl ≥ 20-45 MPa., 0.8 kN for both sizes
Vrec. = Shear working load (static) in concrete fc,cyl ≥ 20-45 MPa., 1.1 kN for both sizes
For assistance in anchor design contact your local Hilti Engineer or call 131 292
lightweight fastenings are needed in weak base materials ■ Ergonomic setting tool for thread size M4 to M8
■ Fastening battens, channels, panels, decorative items ■ Quick and trouble-free installation
SETTING TOOLS
332076 HHD-SZ 2 (for all sizes) 1 1
Features
■ "Shark's tooth" design for correct positioning and quick installation
■ Cuts its own thread
■ One Hilti bit for anchor and screw. No setting tool required.
■ HSP and HFP delivered with or without screws
HSP HFP
HP-S HFP-S Bit for HSP and HFP (D-B PH2 HSP/HFP)
For assistance in anchor design contact your local Hilti Engineer or call 131 292
+
For assistance in anchor design contact your local Hilti Engineer or call 131 292
HRD-U 10
Plastic anchor body, HRD-UGT, Torx T40 head screw HRD-UGS, with hex. head screw
screw steel, zinc plate
Item Ordering Hole Hole Max. fasten. Package Price
no. designation dia. Depth thickness contents per
HRD-U 14
Plastic frame anchor HRD-UGT Countersunk head screw HRD-UGS Hexagon head screw
For assistance in anchor design contact your local Hilti Engineer or call 131 292
■ A plastic toggle anchor for use in a wide range of base materials from ■ Resilient toggling action to suit every base material
4-20 mm thick ■ Versatile in thin walled materials, even if they are of low strength
■ Fastening to virtually all base materials, especially panels or similar ■ Resistance to rotation in hole
For assistance in anchor design contact your local Hilti Engineer or call 131 292
STANDARD
260369 HPS-1 4/0 x 20 4mm 25mm 2mm 250 100
260395 HPS-1 5/0 x 20 5mm 25mm 2mm 250 100
260347 HPS-1 5/5 x 25 5mm 30mm 5mm 200 100
260348 HPS-1 5/15 x 35 5mm 30mm 15mm 200 100
247850 HPS-1 5/15 x 35 bulk 5mm 30mm 15mm 2400 100
260349 HPS-1 6/5 x 30 6mm 40mm 5mm 150 100
230516 HPS-1 6/10 x 35 6mm 40mm 10mm 150 100
260350 HPS-1 6/15 x 40 6mm 40mm 15mm 150 100
247852 HPS-1 6/15 x 40 bulk 6mm 40mm 15mm 1350 100
260351 HPS-1 6/25 x 50 6mm 40mm 25mm 100 100
247853 HPS-1 6/25 x 50 bulk 6mm 40mm 25mm 900 100
260352 HPS-1 6/40 x 65 6mm 40mm 40mm 100 100
252804 HPS-1 6/40 x 65 bulk 6mm 40mm 40mm 900 100
260353 HPS-1 8/10 x 40 8mm 50mm 10mm 100 100
230518 HPS-1 8/20 x 50 8mm 50mm 20mm 50 100
260354 HPS-1 8/30 x 60 8mm 50mm 30mm 50 100
230519 HPS-1 8/40 x 70 8mm 50mm 40mm 50 100
260355 HPS-1 8/60 x 90 8mm 50mm 60mm 50 100
260356 HPS-1 8/80 x 110 8mm 50mm 80mm 50 100
COUNTERSUNK HEAD
260375 HPS-1 5/15 S x 35 5mm 30mm 15mm 200 100
230529 HPS-1 5/30 S x 50 5mm 30mm 30mm 150 100
For assistance in anchor design contact your local Hilti Engineer or call 131 292
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Threaded rod
Item Ordering Price
no. designation per
Couplers
Item Ordering Price
no. designation per
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Masonry plug
Cable ties
Installation accessories
For assistance in anchor design contact your local Hilti Engineer or call 131 292
Flat washer
Item Ordering Package Price
no. designation contents per
Item Ordering Hole Min. hole Anchor Max Fasten. Package Price
no. designation dia. Depth length Thickness contents per
(Nm)
Nail-in plug
Item Ordering Hole Min. hole Package Price
no. designation dia. depth contents per
MUSHROOM HEAD
3419465 5 x 25M 5mm 30mm 500 100
3419466 6.5 x 25M 6.5mm 30mm 300 100
3419467 6.5 x 37M 6.5mm 40mm 200 100
3419468 6.5 x 50M 6.5mm 55mm 100 100
3419469 6.5 x 75M 6.5mm 80mm 100 100
ROUND HEAD
3419470 5 x 25R 5mm 30mm 200 100
3405671 6.5 x 25R 6.5mm 30mm 200 100
Spaghetti plug
Item Ordering Hole Price
no. designation dia. per
PB brass anchor
Item Ordering Hole Min. Hole Anchor Max Fasten. Package Price
no. designation dia. Depth length Thickness contents per
For assistance in anchor design contact your local Hilti Engineer or call 131 292
PROFIS Anchor
More features for design freedom
Hilti PROFIS Anchor offers more flexibility and functionality than any other
anchor design program. Included within the software are a number of features,
exclusive to Hilti, that greatly enhances the user’s choice and efficiency.
■ Easy-to-use 3D interactive display
■ Change and modify designs at the touch of a button
■ A comprehensive easy-to-use anchor selector
■ A database of CAD drawings for all Hilti anchors which can be exported
to other formats
■ 3D baseplate design plus finite element analysis for baseplate
Other major features include:
■ Fully defined designs
thickness calculations
■ Graphical input with all dimensions and loadings visible
■ Personalised settings for user-defined views
■ User-defined print output
PROFIS anchor is available free of charge. ■ Easy-to-understand anchor setting animations
Download it at www.hilti.com.au, or order ■ Supports 13 different anchor design methods and 16 languages
it on CD ROM, ring 131 292. ■ Always up to date with regular downloads and add-ons
Your local Hilti Engineer will be pleased to show it to you ■ Workshop drawings to ensure the fabricators get it right
Advantages
■ Well thought-out: All the information needed for design work provided
quickly by a clear and informative Hilti specification guide, advanced Hilti
Exbar overlay design software or Hilti technical specialists
■ Easier: The connectors require no advance preparation
■ Quicker: Levelling and height adjustment can be carried out during
installation
■ Practical: Loading is possible immediately after setting, so rebar can be
laid while the resin is curing
■ Controllable: Injection of the optimum quantity of adhesive is ensured by
a visual check
■ Dependable: The connectors and the system as a whole have been developed
and tested by Hilti in cooperation with several European Universities
Call your local Hilti Engineer on 131 292 for more information on the
HCC-B system & software