Test Data Sheet: Ref: IS 2185 P-3 - (1984) Format No. F01 (5.4) Issue Date: 01.01.2018

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 2

TEST DATA SHEET

DETERMINATION OF DIMENSIONS TEST OF AAC BLOCK


Ref: IS 2185 P-3-(1984)

Format No. F01(5.4) Issue Date : 01.01.2018

Source/Location Ambient Temperature


27

Type of block Relative Humidity

OBSERVATION & RESULTS

Sr. No. Characteristic Parameters Symbol Unit Results

1 Four position Length of whole block. 625 623 623 625


L mm

2 Six position Height of whole block. 245 246 246 246 247 245
W mm

3 Seven position Thickness of whole block. 222 223 223 223 223 223 223
T mm

4 Avg. Length of whole block. L 624.00


mm

5 Avg. Height of whole block. W 245.83


mm

6 Avg. Thickness of whole block. 222.86


T mm

Remarks:-

TESTED BY CHECKED BY

Page 1 OF 1
TEST DATA SHEET
DETERMINATION OF COMPRESSIVE STRENGTH FOR AUTOCLAVED CEELLULAR CONCERETE (ACC)
[ IS 6441 P-5 (1972) ]
Lab Code Ambient Temprature
Type of block Relative Humidity
Dimension LXWXH-(mm) Loading Rate

Observation & Results


S.No Characteristics Parameters Computation
Block 1 Block 2 Block 3

1 Length (mm) L

Dimension of Block
2 (mm) Width (mm) W

3 Height (mm) H

4 Area of Block (mm2) A = LW

5 Volume of Block (cc) V = ((LWH)/1000)

6 Weight of loss during dring.(g) ΔW

7 Weight of dried out sample.(g) WI

8 Moisture Content Of Block. F=(ΔW/WI)x100

9 Bulk Density of Block. (g/cc) ꝨV = (WI/F)/V

10 Braking Load of Block. (kN) kN

11 Compressive Strength Block. (N/mm 2) Ra = kN/A × 1000

12 Compressive Strength Block. (KG/cm 2) Ra x10.2


_
13 Average Compressive Strength Block. (KG/cm2)
_
14 Average Moisture Content Block.
_
15 Average Bulk Density Block.

Remarks:

TESTED BY CHECKED BY

DOC NO: IS 6441-P-5 (1972)


Test Data Sheet for Compressive Strength of (ACC BLOCK)
ISSUE DATE: 01.01.2020 F02(7.11)