MINERVA® Marine
Features:
MINERVA® Marine Panel Range The decision to sound the alarm is made at the
controller allowing adjustments and compensations
MINERVA® MX is a comprehensive range of fire to be made for changes in environmental conditions.
controllers designed and built to BSEN ISO9001/2 In short, maximum security whilst minimising the risk
and EN54. An advanced proven microprocessor of false alarms.
based system, MINERVA® MX provides conventional
and digital addressable detection for new, refurbished Modular in design MINERVA® MX provides
and refitted detection systems. economical fire detection for small vessels but is also
flexible enough to implement the complex event
A wide range of detectors and ancillaries makes procedures required in larger ones. Detectors are
MINERVA® MX suitable for applications from general controlled in groups of up to 240 zones all software
cargo vessels to large passenger vessels and offshore configurable, so avoiding the expensive need to
installation. hardwire each zone back to the control panel. Further
savings are made possible by harnessing the power of
What should you expect of your fire the latest micro-processing technology to enable a
detection system? single loop of two-core cabling to carry both detection
In broad terms: cost effective reliability and flexibility. and command signals.
In today's vessels under today's conditions you should
also be looking for ease of operation, flexible Backwards compatibility is also achieved by using an
programming, precise fire source pin-pointing and the ancillary module which allows existing fire systems to
kind of circuitry and sensitivity which ensures rapid be updated and extended cost effectively, utilising
activation in the event of a fire. existing wiring where possible and with minimal
disruption. Other ancillary modules offer even greater
MINERVA® MX meets all these system flexibility: short circuit sensing isolation
expectations as a matter of course ensures the T2000 continues in operation, even if a
T2000 is a comprehensive range of fire controllers wiring fault occurs. Local sounder activation further
designed and built to BSEN ISO9001/2 by the reduces wiring costs and switch monitoring allows
world’s leading fire and security company. The T2000 easy interface to a vessels machinery control system.
has been approved by all the major marine authorities.
Further flexibility and installation savings can be made
An advanced proven micro-processor based system using the loop power T2000 options. Loop powered
MINERVA® MX provides conventional as well as T2000 panels allow sounders to be powered from
addressable detection at the price of today's the same loop wires that carry communications and
conventional systems. power to the detectors and other ancillaries.
www.acornfiresecurity.com
Fire Detection
PSF126UM.qxp 20/03/2006 16:49 Page 2
www.acornfiresecurity.com
T2000 Repeaters
The MINERVA® MX full function repeater is an The back box contains the PSM800 power
EN54 Marine approved repeater with optional supply and space for 2 x 7 Ah batteries to
addressable EN54:Pt.4 power supply. The provide 72 h backup.
repeater consists of a stainless steel or mild
steel backbox and cast aluminium front door The T2000 repeater with Power Supply is
which incorporates the ODM800 operator connected to the Panel via the remote bus
display module with a 16 x 40-character (RS485, 1200 m distance). A maximum of 7
backlit LCD display, simple alphanumeric repeaters (including one MX REMOTE
keypad and 5 softkeys. The OCM800 repeater) can be linked to each T2000 panel
operator control module provides all and can provide full repeater functions for all
mandatory operator control keys and LED panels on the system.
functions including Manned/Unmanned
The operator control module (OCM800) can
switching. Two control keys and 2 indication
support up to 80 inputs and outputs in the
LEDs are provided for vessel-specific
form of LED annunciators, IOB800
functions.
input/output modules, XIOM universal I/O
Control keys and LEDs are labelled in English modules or the XIOM 800 LED mimic
according to the default approved module.
functionality. The slide in decals can be
reversed and alternative text added.
www.acornfiresecurity.com
PSF126UM.qxp 20/03/2006 16:49 Page 3
www.acornfiresecurity.com
T2000CV
The T2000 panels are intelligent EN54 The panel has a strong cast aluminium front
approved and marine approved panels, door, which incorporates a modular user
designed for commercial vessels where a interface that fully complies with EN54:pt.2.
large networked system is not required. The user interface incorporates the ODM800
operator display module with a 16 x 40-
The T2000CV panel provides three
character backlit LCD display, simple
loops supporting up to 750 addressable
alphanumeric keypad and 5 softkeys. The
devices
OCM800 operator control module provides
The panel consists of a mild steel enclosure, all mandatory operator control keys and LED
containing: functions including Manned/Unmanned
switching. Two control keys and 2 indication
• PSB800 5A 24Vd.c. battery backed power LEDs are provided for vessel-specific
supply and loop booster functions.
• FIM801CV field interface PCB incorporating
one MX DIGITAL loop Control keys and LEDs are labelled in English
• CPU800 32 bit processor and memory according to the default approved
Card functionality. The slide in decals can be
• XLM800 loop expansion card containing reversed and alternative text added.
two MX Digital loops
• Optional remote diagnostic modem
• Optional IOB800 input/output expansion
card mounted on the PSB800
www.acornfiresecurity.com
PSF126UM.qxp 20/03/2006 16:49 Page 4
www.acornfiresecurity.com
Interfacing Options
MX Remote
PC
OEM
Interface
Modem
Modem
Network
Interface
MX Graph
To PLC
TLO530 TLO530
Fibre Fibre
Interface Interface
Max distance between
nodes is 4000m using
fibre optic cable
VDR
www.acornfiresecurity.com
PSF126UM.qxp 20/03/2006 16:49 Page 5
www.acornfiresecurity.com
Command Modules
Environmental SNM800 Sounder Module
Operating Temp. Range _ 8°C to + 55°C RIM800 Relay Module
Storage Temp. Range _ 20°C to + 70°C CIM800 Contact Monitor Module
Humidity Up to 95% RH (Non-condensing) SB520 Sounder Booster Module
Housing Protection To IP42 TM520 Timer Module
DIM800 Conventional Detector Module
Electrical APM800 Power Supply Monitor Module
Mains Supply 120V-240Vac + 10% / -15% at MIM800 Mini Input Module
50/60Hz CP820M Indoor Callpoint
Secondary Supply 24V d.c. Nominal CP830M Outdoor Callpoint
MIO800 Multi-Input Output Module
T2000R CV Indicating Repeater
Input Voltage 24V d.c. Nominal 8 Loop Support (T2000 Only)
SB800MK 8 Loop Power Expansion Kit
Input XLM800 Loop Expansion Card (Loops)
T2000 Panel T2000 8 Loop Mounting Kit
No. of Loops 2, expandable to 8
Addresses per panel 1000 Max
T2000CV Panel
No. of Loops 3
Addresses per panel 750 Max
Output
T2000 Panel & T2000CV
Display 240 Zone
16 x 40 Character
Sounder There are two separate monitored
sounder outputs each rated at 2A.
Alarm Fire _ Relay output rated at 30V d.c.
at 1.0A volt free c/o.
Fault _ Relay output rated at 30V d.c.
at 1.0A volt free c/o.
www.acornfiresecurity.com