Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

RTKcalc powered by CONVAL® Version 2.0 (Build 2.0.

2)

RTKcalc REGELTECHNIK KORNWESTHEIM GmbH


2/6/2021 Max-Planck-Straße 3 ; 70806 Kornwestheim GERMANY
1:12:04 AM http://www.rtk.de ; info@rtk.de

Calculation header
Identifier New calculation
Tag No. / KKS-Nr. PV2
Text 1 Concise valve Examlple 1
Text 2
Text 3

Medium selection and state


Medium Water
State Liquid

Maximum design parameters


Maximum design temperature tD,max 25.0 °C
Minimum design temperature tD,min 25.0 °C
Maximum design pressure pD,max 13.987 bar(g)

Operating data
Maximum flow Minimum flow
Operating temperature t1 25.0 °C
Pressure upstream of valve p1 15.0 bar(a)
Pressure downstream of valve p2 2.0 bar(a)
Pressure difference p 13.0 bar
Mass flow rate qm 598,610.0 kg/h
Volume flow rate (operating conditions) qv 600.0 m³/h
Discharge coefficient Kv 168.94 m³/h
Type of flow Choking cavitation

Load-dependent values
Calculation standard (noise, lquid) IEC 60534-8-4 (2005-08)
Maximum flow Minimum flow
Stroke/angle-of-rotation ratio s/s100 39.7 %
Flow velocity u1 3.3953 m/s
Sound pressure level of valve (A-weighted) LpAe 82.8 dB(A)

Fluid operating data


Maximum flow Minimum flow
Operating density (t1, p1) 1 997.68 kg/m³
Vapour pressure (t1) pv1 0.031697 bar(a)

Viscosity and laminar flow


Calculation standard (viscosity) IEC 60534-2-1 (1998-09)
Valve Reynolds number Re,v 586,660.0 -
Reynolds number factor FR 1.0 -

Valve data
Series PV 6911
Safety function Air failure open AFO
Actuator type Pneumatic control valve
Valve style Globe valve
Selected valve size DN DN 250
Pressure class PN 25

1(3)
RTKcalc powered by CONVAL® Version 2.0 (Build 2.0.2)

RTKcalc REGELTECHNIK KORNWESTHEIM GmbH


2/6/2021 Max-Planck-Straße 3 ; 70806 Kornwestheim GERMANY
1:12:04 AM http://www.rtk.de ; info@rtk.de

Valve data (continued)


Plug type Perforated plug
Flow direction FTO
Basic characteristic Linear
Nominal flow coefficient Kvs 413.0 m³/h
Seat diameter d 200.0 mm
Valve stroke hV 80.0 mm

Valve configuration
Body material Cast steel EN-GP240-GH
Spindle sealing Stuffing box (standard)
Stuffing box material PTFE-carbon chevron-type
Packing type Standard
End connection Flanges with flat face acc. to DIN 2526 form C
Plug/seat sealing metallically sealing
Seat leakage < 0,01% Kvs (class IV)
Seat options Standard
Painting Surface treatment with zinc dust primary coat
Certificate without
Stem heater without
Power supply stem heater -
Max. design temperature TS 250°C
Max. design pressure PS acc. to DIN EN 1092

Pipe downstream of valve


Material number 1.7357
Material short name A 217 (WC6)
Size class downstream of valve DN2 DN 250
Pressure class downstream of valve PN2 PN 16

Noise prediction data


Calculation standard (noise, lquid) IEC 60534-8-4 (2005-08)
Low-noise design Multihole plug
Sound pressure level of valve (A-weighte... LpAe 82.8 dB(A)

Maxiumum shut-off pressures


Max. upstream pressure (valve closed) p1,A 15.0 bar(a)
Max. downstream pressure (valve clo... p2,A 2.0 bar(a)

Required actuator forces


Friction force (packing box) FrS 1,800.0 N
Min. closing force FDm 1,885.0 N
Fluid force (close position) Fm0 40,328.0 N
Min. closing force (close position) Fs0,m 44,013.0 N
Min. opening force (close position) Fo0,m -38,528.0 N

Actuator selection
Safety reserve fRes 10.0 %
Air supply pressure p,air 6.0 bar(g)
Actuator manufacturer STI
Actuator 420/100

2(3)
RTKcalc powered by CONVAL® Version 2.0 (Build 2.0.2)

RTKcalc REGELTECHNIK KORNWESTHEIM GmbH


2/6/2021 Max-Planck-Straße 3 ; 70806 Kornwestheim GERMANY
1:12:04 AM http://www.rtk.de ; info@rtk.de

Actuator selection (continued)


Opening force (close position) Fs0 81,960.0 N
Opening force (close position) Fo0 81,960.0 N

Pneumatic actuator
Active area 1366 cm²
Fail-safe position at air failure valve CLOSE
Manual operation without
Positioner without
Input signal -
Output signal -
Pressure indicator without
Position feedback without
Limit alarm (regulated by stroke) -
Operating direction positioner -
Operating direction actuator stem -
Booster -
Solenoid valve / Locking relay without
Voltage solenoid valve -
Airset without
Limit switches without

Warning:
Maximum cavitation (choked flow) p (13.0 bar) > 12.58 bar

Hint:
The calculation according to IEC 60534-8-4 (2005-08) was modified based on measured manufacturer
values.

Confirmation:
Values for Flow velocity - u1 (3.395 m/s) are not critical.

Legend
Calculated value
Lookup value
Warning
Hint
Confirmation

3(3)