Static Strength Test Report - BV Signed
Static Strength Test Report - BV Signed
6058 mm X 2438 mm X 2210 mm UN PORTABLE TANK T8 WITH UNIVERSAL COLLAR (SET OUT)
effected subject to the BUREAU VERITAS Regulations ETTC-GM and on basis of ISO standards 1496-3
Tested at CRRC Yangtze Co., Ltd from July 17, 2018 to July 19, 2018
CAQ93-00-00-000 Rev. A
List of drawings CAQ93-01-00-000 Rev. A Maximum payload 26,520KG
CAQ93-08-00-000 Rev. A
MR. Xiong Zhenyan – CRRC Design Engineer, Mr. Shuai Yang – CRRC QC Manager
In attendance of MR. Rocky Zhuang --BV SURVEYOR
I - Condition of freight container on arrival at test centre ( Checking of dimensions : see page 5,6,7 )
B
C Stacking 2 S 8,9
D
E
F Lifting by top corner fittings 3 S 10,12
G
H
I Lifting by bottom corner fittings 4 S 11,12
K
L 5 S 13
Static restraint
M
N
U
Lifting at the base at the grappler arms
V positions
P
Q Lifting by forkligt pockets
S
X
Y Floor strength
Z
Endwall strength
Roof Strength
Mark ** List of tests carried out (continuoued) * Order of tests Comments Page
Transverse rigidity 6 S 17
Longitudinal rigidity 7 S 18
Other tests
KA
Dynamic restraint
LA
CA
Stacking nine-high
DA
CB
Stacking on n heights
DB
FA
Lifting from top corner fittings with slings at 45°
GA
PA
QA Lifting by forklift pockets
SA
before tests 1 S
Dimensions check 5,6,7
after tests
11 S
Mark List of test carried out ( continued ) Order of tests Comments Page
Category D2
± C2
Design dimensions
D1 B2
+0
Length OA 6058 Check of dimensions A2
-6 C1
+0
Width OA 2438 B1
-5
+0
Heigh OA 2210
-5 A1
Diagonals Length
Position Ref. ± Position Ref. ±
Before After Before After
K1 19 16 13 10
Value of K
K2 10 10 10 10
ISO/TC 104 1161
Value of K is given by document
Result SATISFACTORY
C1
A1
C2 A2 Check of dimensions ( continued)
Y
0
X = 101.5 - 1.5 mm
0
Y = 89 - 1.5 mm
Y
B1
D Condition of corner fittings
B2
D
2
Roof SATISFACTORY
Result :
Transverse member
+5
- 1.5
12.5 mm
300 min
0
80 min.
12
-2
100 min.
51 min
2400 min.
Base of corner fittings
Result : N.A.
C2 A2
(D2) (B2)
Dimensions
Container
mm
A B C D A’ B’ C’
C X 1D
C1 900 305 102 20
D D 1E
1F ±50 min. min. min.
C1 B1 1
A1 B
(D1)
A1
A
X
Result N.A
Section X X
Dimensions
A
Lt 3150 ~ 3500 mm
Length
D 6 ± 2 mm
D Lt 3
Width At 1029 ± mm
0
Bt 120 0 mm
Height -3
+5
C 12.5 mm
-1.5
Bt
Result
N.A
Stacking test
Test method :
The container evenly loaded to R (R=tare + load) will be placed on 4 level pads and subjected to a vertical test load of 192,000kg
equally distributed over the 4 upper corner fittings, by means of four chocks and substantially of the same plane dimensions,
one over each top corner fittings, offset in the same direction by 25 mm (1”) lateral and 38 mm (1 1/2”) longitudinally.
D2 25 B2 D2 B2
D1 B1 D1 B1
C2 A2 C2 A2
C1 A1 25 C1 A1
Note :
THE MAXIMUM ALLOWABLE STACKING LOAD IS DESIGNED TO 121,920 kg.
D2
B2
D1 h a B1
NOTE : Measurements of deflections will be
g b
taken at the centre of and at half the
f c
height of corner structures.
C2 e d A2
C1 A1
Test load Summary of corner structures deflections during test Changes in length of corner
A1A2, B1B2, C1C2, D1D2. structures
A1A2, B1B2, C1C2, D1D2.
1st test :
Offset direction
Test load at : 54864 kg/post
Before Test 0 0 0 0 0 0 0 0
2nd test :
Offset direction
Test load at : 54864 kg/post
Before Test
Comments :
Result SATISFACTORY
Test method :
The freight container under test is loaded to 2R, and is lifted by all four top corners in such a way that no significant
acceleration or deceleration forces are applied.
For series 1A, 1AA, 1B, 1BB, 1C and 1CC containers, the lifting forces shall be applied vertically.
For containers designated 1D, 1E and 1F, lifting shall be carried out by means of slings, the angle of each leg being at 30º
from the vertical.
The container shall be suspended for not less than 5 minutes and then lowered to the ground.
Test method :
This test shall be carried out on 1A, 1AA, 1B, 1BB, 1C, 1CC and 1D containers. It shall be carried out on 1E and 1F containers,
if they are equipped with bottom corner fittings. The container under test shall be loaded to a total weight equivalent to 2R, and
carefully lifted from the four bottom corner fittings in such a way that no significant acceleration or deceleration forces are
applied. In each case, the line of action of the lifting forces shall be 38 mm (1 1/2 in) form the face of the corner fittings and
parallel to it.
The container shall be suspended for five minutes, then lowered to the ground.
The lifting test can be carried out by attaching additional load weights in such a manner that the forces are conducted through
the tank supporting points.
It is not permitted to attached additional load weights to either the corner fittings or the frame. This test must be carried out
prior to mounting the tank’s outer casing ; It is not applicable in every case to multi-shell tanks.
D2 B2
Position of points at which deflections are measured
C2 A2
Condition Mark 1 2 3 4 5 6 7
Empty 0 0 0 0 0 0 0 0
Condition Mark 1 2 3 4 5 6 7
Empty O
Result SATISFACTORY
Test method
The freight container, loaded with a uniformity distributed load to a total weight of R, shall be secured to rigid anchor
points by the bottom securing points, at one end. A load equal to 2 x R (daN) shall be applied longitudinally to the
container, through the bottom securing points, at the other end, first in compression, and then in tension.
D2
R = 30,480KG B2
A2
2R = 60,960KG C2
D1
B1
C1
A1
Force applied at the bottom part of corner fittings ( 5 minutes )
1 2
Loading Before test During test After test Longitudinal Vertical
deformation deformation
Mark J K L
A1 C1 0 -1 0
1
B1 D1 0 -1 -1
Compression
A1 C1 0 -1 0
2
B1 D1 0 -1 1
Mark L M N
A1 C1 0 +1 +1 +1
1
Traction
B1 D1 -1 +1 0 0
A1 C1 0 1 1 1
2
B1 D1 1 1 1 1
Comments
Result SATISFACTORY
Deflections of the longitudinal frame and transverse members under differents loads
e p e p e p e p e p e p e p
O EMPTY On pads 0 0 0 0 0 0 0
A R-T On pads
B R-T On pads 0 0 0 0 0 0 0
D 1.8R-T On pads 0 0 0 0 0 0 0
DA R-T On pads
DB KR-T* On pads
E 2R-T On pads 0 0 0 1 0 0 2
G 2R-T On pads 0 0 1 0 0 0 1
e = Elastic deformation (*) (k) and (n) : Values to be laid down by client or by test centre
p= Permanent set v = vertical
Deflections of the longitudinal frame and transverse members under differents loads
E p e p e p e p e p e p e p
I 2R-T On pads 0 0 0 0 0 0 0
GA 2R-T On pads
J R-T On pads 0 0 0 0 0 0 0
L R-T On pads 0 1 0 1 0 0 0
N R-T On pads 1 1 1 1 1 0 1
LA R-T On pads
e = Elastic deformation
p= Permanent set
e p e p e p e p e p e p e p
S 1.6R-T On pads
V 1.25R-T On pads
X EMPTY On pads
Z EMPTY On pads
Comments
e= Elastic deformation
C1 A1 B
D1
c 1
Pushing Pushing
0 0 0 0 0 0 0 0 0 0 0
50 50
90 90
125 125
150(**) 1 1 2 60 150(**) 1 1 2 60
0 1 0 1 0 1 1 2
Pulling Pulling
0 0
50 50
90 90
125 125
150(**) 1 0 1 60 150(**) 1 1 2 60
After tests
0 1 0 1 10 0 1 1 2 10
A2 B2 D2
C2
75kN
75kN
C1 D1
A1 B1
Force (kN) Displacement of C2or A2 Limit Force (kN) Displacement of D2or B2 Limit
Pushing Pushing
0 0 0 0
40 40
75(**) 3 25 75 (**) 2 25
0 1 0 1
Pulling Pulling
0 0
40 40
75 (**) 1 25 75 (**) 1 25
After tests
0 0 7 0 0 7
1C-1CC = 7 mm
(***) 1B-1BB = 8.3 mm
1A-1AA = 9.7 mm
Result SATISFACTORY
Test method :
The tank container under test shall be loaded to R. The tank container shall be positioned with its transverse axis vertical. It
shall be held in this position by supports at the lower end of the base structure of the tank container acting through the bottom
corner fittings in such a manner as to provide vertical and lateral securements. At the upper end of the base structure of the
tank container, anchor devices acting through the bottom corner fittings shall be provided to give lateral restraint only. No
securements shall be fixed to the top corner fittings. The tank container shall be held in this position for not less than 5
minutes.
Before test 0
During test 1
After test 0
Result
SATISFACTORY
Walkway test
Test method :
Walkways, where provided, shall be tested with a load equal to 300 kg distributed over an area of 600mm x 300mm located at
its weakest part.
SATISFACTORY
Result
Ladder test
Test method :
Ladders, where provided, shall be tested with a load equal to 200kg on any rung.
SATISFACTORY
Result
NOTES :
• THE ABOVE TEST REPORT IS SUBJECT TO WITNESS BASED ON ISO 1496-3 AND BV RULE RELEVANT
CHAPTERS/CLAUSES;