NORSOK STANDARD

SYSTEM REQUIREMENTS

DERRICK/MAST AND HOISTING EQUIPMENT


SYSTEM NO. 10-10

D-SR-001

Rev. 1, December 1994

Please note that whilst every effort has been made to ensure the accuracy of the NORSOK standards neither OLF nor TBL or any of their members
will assume liability for any use thereof.

1 FOREWORD

This standard has been developed by the NORSOK standardisation work group and agreed by the
Norwegian industry for the widest possible national and international application.

2 SCOPE

3 NORMATIVE REFERENCES

• API spec. 8C PSC 2 (Replace with ISO 13535 in development).


• API spec. 9A (Replace with ISO 10425 in development).
• API spec. 4F (Replace with ISO 13626 in development).
• API spec. 7K.

4 DEFINITIONS AND ABBREVIATIONS

4.1 Definitions

4.2 Abbreviations

5 FUNCTIONAL REQUIREMENTS

5.1 General

The derrick/mast and hoisting equipment shall transport tubulars and equipment in and out of the
wellbore, as well as providing a predetermined weight on the bit (WOB).

D-SR-001, Rev. 1, December 1994 page 1


5.2 Products/Services

5.3 Equipment/Schematic

The system should consist of the following main items:

• Derrick or mast w/crown block, guide rails, ladders, gangways, lightening etc.
• Travelling block.
• Elevators/spiders.
• Drawwork.
• Drill line.
• Deadline anchor.
• Derrick escape line.
• Power slips.

5.4 Performance

Class I Class II
Derrick/mast and hoisting equipment rating (kN) 4448 (500 ton) 5783 (650 ton)
Drawwork horsepower (kw) (or equivalent for hydr. 1500 2250
drawworks)

5.5 Regularity

5.6 Process/Ambient Conditions

North Sea environmental conditions shall apply.

5.7 Operational Requirements

• The derrick shall be capable of skidding with full set back in 25m/s wind.
• A travelling block hang off system shall be included in the design. The system shall support
the weight of the top drive and the travelling block.
• A stop/warning system to prevent collision of the travelling block/top drive with drill-floor,
crown block and pipehandling system racking-arms etc. shall be included in the design.
• The derrick/mast shall include sufficient number of certified pad eyes for snatch blocks.
• The derrick/mast shall be equipped with a retractable guiding system for travelling
block/topdrive with enough offset to avoid interference between the drillpipe in the rotary
table and the travelling block/top drive.
• The hoisting arrangement shall allow for entering of wireline tools through the top drive.
• Lubrication points with difficult access, f.ex. sheaves below the crown block, shall be
collected in a central lubrication system.
• An escape arrangement in addition to the normal access way, leading away from the
derrick/mast to a safe area, shall be provided.
• The derrick/mast design shall allow for conductor installation.
• All equipment, light, etc. in the derrick/mast shall be secured with soft wires.

D-SR-001, Rev. 1, December 1994 page 2


5.8 Maintenance Requirements

It shall be possible to dismantle the crowblock without laying down the derrick/mast.

5.9 Isolation and Sectioning

5.10 Layout Requirements

5.11 Interface Requirements

5.12 Commissioning Requirements

Norsok HomePage

Send comments to NORSOK standards

D-SR-001, Rev. 1, December 1994 page 3