Submission Prohibited

NEC Group Internal Use Only


GGS-000376-06E
January 2017

iPASOLINK VR 10
SPECIFICATIONS

NEC Corporation
7-1, Shiba 5-Chome, Minato-Ku, Tokyo 108-8001, Japan
Submission Prohibited
NEC Group Internal Use Only
GGS-000376-06E

© 2015 – 2017 by NEC Corporation

GGS-000376-06E
Printed in Japan
Submission Prohibited
NEC Group Internal Use Only
CONTENTS –i–

iPASOLINK VR 10
SPECIFICATIONS

CONTENTS

1. INTERFACES 1-1

1.1 iPASOLINK VR 10 and Designated Slots . . . . . . . . . . . . . . . . . . . . . . . 1-1


1.1.1 Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.1.2 Card Slots on iPASOLINK VR 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2 Location of Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1 Fundamental Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1.1 MC-MV (Main Card) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1.2 TERM-MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1.3 PS-MV (Power Supply) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.2.1.4 FAN-MV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.2.2 Cards for Universal Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.2.1 MODEM-A/EA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.2.2 MODEM-AV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.2.3 MSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.2.4 STM1-A THROUGH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.2.5 16E1-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.2.6 GbE-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.2.2.7 XGbE-MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.2.3 CWDM Filter Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.2.3.1 CWDMFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.2.3.2 CWDMFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

2. SPECIFICATION 2-1

2.1 Interface Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1


2.1.1 Ethernet Traffic Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.2 E1 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.3 STM1-A Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.4 Radio Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.5 Management Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


January 2017
Submission Prohibited
NEC Group Internal Use Only
– ii/END – CONTENTS

2.1.6 Other Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2


2.2 Supported Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.1 Radio Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.1.1 Modulation and Radio Capacity — MODEM-A . . . . . . . . . . . . . . . 2-4
2.2.1.2 Modulation and Radio Capacity — MODEM-EA . . . . . . . . . . . . . . 2-4
2.2.1.3 Modulation and Radio Capacity — MODEM-AV . . . . . . . . . . . . . . 2-5
2.2.2 TDM Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.2.3 ETH Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2.2.4 MPLS-TP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.2.5 Management Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.2.6 Synchronization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.2.7 Performance Monitor and Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.3 Traffic Interface Specifications and Standards . . . . . . . . . . . . . . . . . . 2-9
2.3.1 STM-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
2.3.2 1000BASE-X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
2.3.3 10GBASE-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11

3. SYSTEM PERFORMANCES 3-1

3.1 Power Consumption and Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1


3.2 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.2.1 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.2.2 Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.3 Power Line Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.3.1 Input Voltage and Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.3.2 Rated Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.4 Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

GGS-000376-06E iPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
INTERFACES 1-1

1. INTERFACES

1.1 iPASOLINK VR 10 and Designated Slots

1.1.1 Front View

1.1.2 Card Slots on iPASOLINK VR 10

Universal Slot #1 Universal Slot #2 Universal Slot #3 Universal Slot #4

Universal Slot #5 Universal Slot #6 Universal Slot #7 Universal Slot #8 FAN1

Universal Slot #9 MAIN CARD 1 Main Card Slot #1

Universal Slot #10 Main Card Slot #2

Universal Slot #11 Universal Slot #12 Universal Slot #13 Universal Slot #14 FAN2

TERM PS 1 PS Slot #2

Slots for fundamental cards that must be mounted.

Slot # Slots for option cards, which can be left vacant.


PS Power Supply

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
1-2 INTERFACES

1.2 Location of Terminals

1.2.1 Fundamental Cards

1.2.1.1 MC-MV (Main Card)

➀ ➁ ➂ ➃ ➄

Ref. # Indication Element Description

➀ EOW Pin Jack Connecting terminal for OW Headset.

➁ CALL Push Button Press the button to call the opposing site by OW.

➂ PROTECT Rocker Switch Switch to manage OOS (Out Of Service)

➃ MEM USB Type-A Connecting terminal for USB memory device. (Supporting
a memory device only.)

➄ LCT RJ-45 Connector Ethernet port for connecting WebLCT. (Supporting 10/
100BASE-TX; Auto-Negotiation, Auto-MDI/MDIX.)

1.2.1.2 TERM-MV

➀ ➁ ➂

CLK

Ref. # Indication Element Description

➀ NMS RJ-45 Connector Terminal for connecting to upstream of DCN Network.

➁ NE1 RJ-45 Connector Terminal for connecting to downstream of DCN Network.

➂ CLK High Density D-Sub Terminal for Clock Signal input/output. (15 pins)
Connector

GGS-000376-06E IPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
INTERFACES 1-3

1.2.1.3 PS-MV (Power Supply)

Ref. # Indication Element Description

➀ PWR / SELV D3100 S Connector Terminal for –48 V DC power supply. Use the Safety Extra
Low Voltage (SELV).

1.2.1.4 FAN-MV

Standard Type High-Powered Type Standard Type


(Original) (Remodeled) (Remodeled)

Ref. # Indication Element Description

—— —— —— FAN-MV provides no front-accessing terminals.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
1-4 INTERFACES

1.2.2 Cards for Universal Slots

1.2.2.1 MODEM-A/EA
NOTE: MODEM-A is currently not available to use when the Equipment
Mode is set to MPLS-TP.

 Available Slots: Restricted (Slots #1 to #8, #11 to #14)

➀ ➁ ➂ ➃

Ref. # Indication Element Description

➀ IF TNC Connector IF Terminal connecting to the Outdoor Unit (ODU).

➁ Cross Slot Screw Grounding terminal; screw shaft diameter is 4 mm.

➂ XIF IEC-MIN Connector Connecting terminals for configuring XPIC.

➃ MD/ODU PWR Toggle Switch Switch to supply power to MODEM and ODU.

1.2.2.2 MODEM-AV
NOTE: MODEM-AV is currently not available to use when the Equipment
Mode is set to MPLS-TP.

 Available Slots: Restricted (Slots #1 to #8)

➀ ➁ ➂

Ref. # Indication Element Description

➀ IF TNC Connector IF Terminal connecting to the Outdoor Unit (ODU).

➁ Cross Slot Screw Grounding terminal; screw shaft diameter is 4 mm.

➂ MD/ODU PWR Toggle Switch Switch to supply power to MODEM and ODU.

GGS-000376-06E IPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
INTERFACES 1-5

1.2.2.3 MSE
 Available Slots: All Slots (#1 to #14)

Ref. # Indication Element Description

—— —— —— MSE Card provides no front-accessible terminals.

1.2.2.4 STM1-A THROUGH

 Available Slots: All Universal Slots (#1 to #14)

SFP Module Ports ➀ ➁ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN 1 SFP Module Port STM-1 Optical Port 1; using SFP.

➁ OUT IN 2 SFP Module Port STM-1 Optical Port 2; using SFP.

1.2.2.5 16E1-A

 Available Slots: All Universal Slots (#1 to #14)

Ref. # Indication Element Description

➀ 2M IN/OUT MDR Connector E1 Traffic Signal Input/Output

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
1-6 INTERFACES

1.2.2.6 GbE-A
 Available Slots: Restricted (Slots #9 to #12)

➀ ➁ ➂ ➃ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ 1 RJ-45 Connector Traffic Terminal for FE/GbE Interface.

➁ 2 RJ-45 Connector Traffic Terminal for FE/GbE Interface.

➂ 3 SFP Module Port Traffic Terminal for GbE Interface.

➃ 4 SFP Module Port Traffic Terminal for GbE Interface.

1.2.2.7 XGbE-MV
NOTE: XGbE-MV is currently not available to use when the Equipment
Mode is set to MPLS-TP.
 Available Slots: Restricted (Slots #13 and #14)

➀ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN 1 SFP+ Module Port Traffic Terminal for 10GbE [SR/LR/ER] Interface.

GGS-000376-06E IPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
INTERFACES 1-7

1.2.3 CWDM Filter Box

1.2.3.1 CWDMFA

CLASS 1 LASER PRODUCT ➀ ➁


CLASS 1M LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN SFP Module Port Traffic Terminal for GbE Interface.

➁ CWDM LC Connector Traffic Terminal for CWDM Interface.

1.2.3.2 CWDMFB

CLASS 1 LASER PRODUCT ➀ ➁


CLASS 1M LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN SFP Module Port Traffic Terminal for GbE Interface.

➁ CWDM LC Connector Traffic Terminal for CWDM Interface.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
1-8/END INTERFACES

This page is intentionally left blank.

GGS-000376-06E iPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
SPECIFICATION 2-1

2. SPECIFICATION

2.1 Interface Capacity

iPASOLINK VR supports various interfaces conforming to the ITU-T Standards and


IEEE Standards:

2.1.1 Ethernet Traffic Interfaces


INTERFACE SPEC CONNECTOR SUPPORTING CARD

10GBASE-SR/LR/ER 10 Gbps LC (SFP+ Module) 1 on XGbE (up to 2 ports per IDU)


NOTE:

1000BASE-SX/LX/CWDM 1.25 Gbps LC (SFP Module) 2 on GbE-A (up to 8 ports per IDU)
[802.3]

10/100/1000BASE-T/TX (TX) 125 Mbps RJ-45 2 on GbE-A (up to 8 ports per IDU)
(T) 10 Mbps

NOTE: 10 GbE Interface is currently not available when the Equipment Mode is set to
MPLS-TP.

2.1.2 E1 Interface
INTERFACE SPEC CONNECTOR SUPPORTING CARD

HDB-3 [G.703] 16 × E1 (2.048 Mbps) MDR68 16 on 16E1-A (up to 224 ports per
IDU)
75 ohms, 120 ohms (selectable)

2.1.3 STM1-A Interface


INTERFACE SPEC CONNECTOR SUPPORTING CARD

S-1.1 / L-1.1 [G.957] 2 × 155.52 Mbps LC (SFP Module) 2 on STM1-A Through (up to 28
ports per IDU)(
CWDM

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
2-2 SPECIFICATION

2.1.4 Radio Interface


INTERFACE SPEC CONNECTOR DESCRIPTION

IF (IDU-ODU Interface) –48 V DC, TX IF, TNC 1 on MODEM-A/EA (up to 12 ports per IDU)
RX IF, ODU SV NOTE:

1 on MODEM-AV (up to 8 ports per IDU)


NOTE:

NOTE: MODEM-A and MODEM-AV Cards are currently not available to use when the
system urns in the MPLS-TP mode.

2.1.5 Management Interface


INTERFACE SPEC CONNECTOR DESCRIPTION

10/100BAE-T/TX (TX) 125 Mbps RJ-45 1 (LCT) on MC-MV


(T) 10 Mbps
1 (NMS) on TERM-MV

1 (NE1) on TERM-MV

2.1.6 Other Interfaces


INTERFACE SPEC CONNECTOR DESCRIPTION

Oderwire Headset 4-Wire Voice Channel Pin Jack 1 (EOW) on MC-MV

External Storage USB Type-A Female 1 (MEM) on MC-MV

GGS-000376-06E IPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
SPECIFICATION 2-3

2.2 Supported Functions


iPASOLINK VR 10 supports the following functions:

2.2.1 Radio Functions


Functions Supported Items
Channel Spacing MODEM-A
7 MHz, 14 MHz, 28 MHz, 40 MHz, 56 MHz
NOTE 1., NOTE 2. MODEM-EA
MODEM-AV 7 MHz, 14 MHz, 28 MHz, 40 MHz, 56 MHz, 80 MHz, 112 MHz
Modulation MODEM-A 7 Modulation Schemes are changeable: QPSK, 16QAM,
32QAM, 64QAM, 128QAM, 256QAM, 512QAM
NOTE 1., NOTE 2.
MODEM-EA 9 Modulation Schemes are changeable: QPSK, 16QAM,
32QAM, 64QAM, 128QAM, 256QAM, 512QAM, 1024QAM,
2048QAM
MODEM-AV 10 Modulation Schemes are changeable: QPSK, 16QAM,
32QAM, 64QAM, 128QAM, 256QAM, 512QAM, 1024QAM,
2048QAM, 4096QAM
Configuration 1+0 MODEM-A
Up to 12 systems per IDU
MODEM-EA
MODEM-AV Up to 8 systems per IDU
1+1 SWG MODEM-A
Up to 6 Switch Groups per IDU
MODEM-EA
NOTE 3.
MODEM-AV Up to 4 Switch Groups per IDU
RTA Group MODEM-A
Up to 8 configurations per IDU
MODEM-EA
NOTE 4.
MODEM-AV Up to 6 configurations per IDU
1+0 XPIC MODEM-A
Up to 6 configurations per IDU
Group MODEM-EA
MODEM-AV Up to 4 configurations per IDU
1+1 XPIC MODEM-A
Up to 3 configurations per IDU
Group MODEM-EA
MODEM-AV Up to 2 configurations per IDU

NOTES:
1. MODEM-A Card is currently not available to use when the Equipment Mode is set
to MPLS-TP.
2. MODEM-AV Card is currently not available to use when the Equipment Mode is set
to MPLS-TP.
3. The 1+1 SWG Configuration is currently not available when the Equipment Mode is
set to MPLS-TP.
4. RTA Configuration is currently not available when the Equipment Mode is set to
MPLS-TP.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
2-4 SPECIFICATION

2.2.1.1 Modulation and Radio Capacity — MODEM-A

Radio Capacity
Modulation
CS: 7 MHz CS: 14 MHz CS: 28 MHz CS: 40 MHz CS: 56 MHz

512QAM 50MB 100MB 200MB 300MB 400MB

256QAM 50MB 100MB 200MB 300MB 400MB

128QAM 50MB 100MB 150MB 200MB 300MB

64QAM 50MB 100MB 150MB 150MB 300MB

32QAM 50MB 50MB 100MB 150MB 200MB

16QAM 50MB 50MB 100MB 100MB 200MB

QPSK 50MB 50MB 50MB 50MB 100MB

NOTE: MODEM-A is currently not available to use when the Equipment


Mode is set to MPLS-TP.

2.2.1.2 Modulation and Radio Capacity — MODEM-EA

Radio Capacity
Modulation
CS: 7 MHz CS: 14 MHz CS: 28 MHz CS: 40 MHz CS: 56 MHz

2048QAM N/A 100MB 300MB 400MB 500MB

1024QAM 50MB 100MB 200MB 300MB 500MB

512QAM 50MB 100MB 200MB 300MB 400MB

256QAM 50MB 100MB 200MB 300MB 400MB

128QAM 50MB 100MB 150MB 200MB 300MB

64QAM 50MB 100MB 150MB 150MB 300MB

32QAM 50MB 50MB 100MB 150MB 200MB

16QAM 50MB 50MB 100MB 100MB 200MB

QPSK 50MB 50MB 50MB 50MB 100MB

GGS-000376-06E IPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
SPECIFICATION 2-5

2.2.1.3 Modulation and Radio Capacity — MODEM-AV

Radio Capacity
Modulation
CS: CS: CS: CS: CS: CS: CS:
7 MHz 14 MHz 28 MHz 40 MHz 56 MHz 80 MHz 112 MHz

4096QAM N/A N/A 300MB 400MB 600MB N/A N/A

2048QAM N/A 100MB 300MB 400MB 500MB 600MB 1000MB

1024QAM 50MB 100MB 200MB 300MB 500MB 600MB 800MB

512QAM 50MB 100MB 200MB 300MB 400MB 600MB 800MB

256QAM 50MB 100MB 200MB 300MB 400MB 500MB 600MB

128QAM 50MB 100MB 150MB 200MB 300MB 500MB 600MB

64QAM 50MB 100MB 150MB 150MB 300MB 400MB 500MB

32QAM 50MB 50MB 100MB 150MB 200MB 300MB 500MB

16QAM 50MB 50MB 100MB 100MB 200MB 300MB 400MB

QPSK 50MB 50MB 50MB 50MB 100MB 100MB 200MB

NOTE: MODEM-AV is currently not available to use when the Equipment Mode is set
to MPLS-TP.

2.2.2 TDM Functions


Functions Supported Items
Crossconnect Terminal Point 16E1-A Up to 16 per card, up to 224 per IDU
(E1 Channel)
STM1-A Up to 63 per card, up to 882 per IDU
MODEM-A/EA Up to 152 per card, up to 1824 per IDU NOTE 1.
MODEM-AV Up to 152 per card, u to 1216 per IDU NOTE 2.
MSE-A Up to 64 per card, up to 128 per IDU
Crossconnect Terminal Point STM1-A Up to 2 per card, up to 28 per IDU
(STM-1 Channel)
MODEM-A/EA Up to 2 per card, up to 24 per IDUNOTE 1.
MODEM-AV Up to 2 per card, up to 16 per IDUNOTE 2.
Crossconnect Capacity E1 Channel 2-Way Up to 975 per IDU
[(12 × MODEM-152CH) + (2 × STM1-A-63CH)]  2

NOTES:
1. MODEM-A is currently not available to use when the Equipment Mode is set to
MPLS-TP.
2. MODEM-AV is currently not available to use when the Equipment Mode is set to
MPLS-TP.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
2-6 SPECIFICATION

2.2.3 ETH Functions

Functions Supported Items

VLAN VLAN ID Up to 4094 per IDU

C-Bridge Instance Up to 16 per IDU


NOTE 1: This option is currently not available
when the Equipment Mode is set to MPLS-TP.

Customer Bridge Up to 15 per C-Bridge Instance


(in C-Bridge Instance) NOTE 2: This option is currently not available
when the Equipment Mode is set to MPLS-TP.

VLAN Swap Up to 256 per IDU


NOTE 3: This option is currently not available
when the Equipment Mode is set to MPLS-TP.

FDB All Entries


Up to 32K per IDU
(Dynamic + Static)

Static Entries Up to 256 per IDU

Filter Ingress Filter Up to 16 per IDU

Egress Filter Up to 16 per IDU

Filter Rules (L2/L3) Up to 512 per IDU

QoS (VLAN Based) VLAN Group Up to 8 per IDU


NOTE: Up to 4095 VLANs per VLAN Group

Priority Shaper Up to 8 per IDU

Mapping Table Up to 16 per IDU

QoS (Port Based) Classification Profile Up to 16 per IDU

Policer Policer Instance Up to 256 per IDU

Policer Rate Profiler Up to 64 per IDU

ETH OAM MEG Instances Up to 128 per IDU

MEP Instances Up to 128 per IDU

Peer MEP Up to 32 per IDU

Ethernet Ring Ring Index Up to 16 per IDU

RSTP/MSTP MSTI Up to 4 per Instances

Link Aggregation LAG Member Up to 8 per LAG

LAG Instance Up to 8 per IDU

NOTE: QoS (VLAN Based) is currently not available when the Equipment Mode is set
to MPLS-TP.

GGS-000376-06E IPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
SPECIFICATION 2-7

2.2.4 MPLS-TP
Functions Supported Items

E2E (End-to-End) Path Channel PW Up to 128 per IDU

Path LSP Up to 2048 per IDU

XC Up to 1024 per IDU

Linear Protection E2E LSP Up to 128 per IDU

MPLS-TP OAM MEG Up to 128 per IDU


[G.8113.1]
MEP LSP MEP Up to 128 per IDU

Peer MEP Up to 128 per IDU

MIP Up to 64 per IDU

2.2.5 Management Plane


Functions Supported Items

Inband Management VLAN Inband Interface Up to 4 per IDU

NMS Management VLAN NMS Port Up to 4 per IDU

Software Bridge Software Bridge ID Up to 8 per IDU

User Account User Account Up to 100 per IDU

ARP ARP Cache Up to 1024 per IDU

Static ARP Up to 256 per IDU

Routing Static Route Up to 128 per IDU

NTP NTP Server Up to 4 per IDU

DHCP DHCP Server Up to 3 per IDU

DHCP Relay Up to 4 per IDU

SNMP SNMP Community Up to 10 IDU

SNMP Trap Up to 3 per IDU

RADIUS RADIUS Server Up to 3 per IDU

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
2-8 SPECIFICATION

2.2.6 Synchronization
Functions Supported Items

Timing Source Up to 3 per IDU

PTP Port Entry Up to 26 Physical Ports per IDU


NOTE:
Master Entry Up to 5 Physical Ports per IDU

NOTE: PTP is currently not available when the Equipment Mode is set to MPLS-TP.

2.2.7 Performance Monitor and Logs


Functions Supported Items

Log History Log Command, Event, Alarm


Up to 8,000 items per system

PM 15-Min History (Instance)

1-Day History (Instance)

VLAN Counter Up to 256 per IDU

LSP Counter Up to 256 per IDU

GGS-000376-06E IPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
SPECIFICATION 2-9

2.3 Traffic Interface Specifications and Standards

2.3.1 STM-1
ITEM SPECIFICATIONS

Nominal Bit Rate 155.520 Mbit/s

Application Code [ITU-T G.957] S-1.1 L-1.1 CWDM

Transmitter at Reference Point S

Operating Wavelength Range 1261 to 1360 nm 1263 to 1360 nm 1471 to 1611 nm

Maximum Mean Launched Power –8 dBm 0 dBm 5 dBm

Minimum Mean Launched Power –15 dBm –5 dBm 0 dBm

Minimum Extinction Ratio (dB) 8.2 dB or more 10 dB or more 10 dB or more

Receiver at Reference Point R

Operating Wavelength Range 1261 to 1360 nm 1263 to 1360 nm 1260 to 1620 nm

Maximum Mean Launched Power –28 dBm –34 dBm –34 dBm

Minimum Mean Launched Power –8 dBm –10 dBm –3 dBm

Others

Type of Fiber Cable SMF

Connector LC Connector using SFP

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
2-10 SPECIFICATION

2.3.2 1000BASE-X
ITEM SPECIFICATIONS

Application IEEE802.3 Full Duplex

1000BASE-SX 1000BASE-LX CWDM

Nominal Bit Rate 1250 Mbit/s

Coding Method 8B/10B

Transmitter at Reference Point S

Operating Wavelength Range 770 to 860 nm 1270 to 1355 nm 1471 to 1611 nm

SMSR 0.85 dB (RMS) 4 dB (RMS) 5 dB

Maximum Mean Launched Power 0 dBm –3 dBm 5 dBm

Minimum Mean Launched Power –9.5 dBm –11 dBm 0 dBm

Minimum Extinction Ratio (dB) 9 dB or more 9 dB or more 9 dB or more

Receiver at Reference Point R

Operating Wavelength Range 770 to 860 nm 1270 to 1355 nm 1260 to 1620 nm

Maximum Mean Launched Power –17 dBm –19 dBm –22 dBm

Minimum Mean Launched Power –0 dBm –3 dBm –3 dBm

Others

Target Distance 550 m 5 km 40 km or longer

Type of Fiber Cable MMF: GI Cable SMF: SI Cable


(Core/Clad dia.: 50/125 µm) (Core/Clad dia.: 9/125 µm)

Connector LC Connector using SFP

GGS-000376-06E IPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
SPECIFICATION 2-11

2.3.3 10GBASE-R
NOTE: 10 GbE Interface is currently not available hen the Equipment Mode is set to
MPLS-TP.

ITEM SPECIFICATIONS

Application IEEE802.3 Full Duplex

10GBASE-SR 10GBASE-LR 10GBASE-ER

Nominal Bit Rate 10.3125 Gbit/s

Coding Method 64B/66B

Transmitter at Reference Point S

Operating Wavelength Range 840 to 860 nm 1260 to 1355 nm 1530 to 1565 nm

SMSR —— 30 dB 30 dB

Maximum Mean Launched Power –2.8 dBm 0.5 dBm 4.0 dBm

Minimum Mean Launched Power –4.3 dBm –8.2 dBm –4.7 dBm

Minimum Extinction Ratio (dB) 3 dB 3.5 dB or more 3.0 dB

Receiver at Reference Point R

Operating Wavelength Range 840 to 860 nm 1260 to 1355 nm 1530 to 1565 nm

Maximum Mean Launched Power –1 dBm 0.5 dBm –1.0 dBm

Minimum Mean Launched Power –9.9 dBm –14.4 dBm –15.8 dBm

Others

Target Distance 300 m 10 km 40.km

Type of Fiber Cable MMF: Core/Clad SMF: Core/Clad SMF: Core/Clad


(dia. 50/125 µm) (dia. 9/125 µm) (dia. 9/125 µm)

Connector LC Connector using SFP+

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
2-12/END SPECIFICATION

This page is intentionally left blank.

GGS-000376-06E iPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
SYSTEM PERFORMANCES 3-1

3. SYSTEM PERFORMANCES

3.1 Power Consumption and Size


POWER DIMENSIONS
Ref. OBJECT WEIGHT DESCRIPTION
CONSUMPTION [W × H × D] mm

IDU 322 W 15 kg Fully installed (approx.)


1 483 × 129 × 230
——— 7.0 kg Chassis (vacant slots)

2 MC-MV 26 W★ 300 × 22 × 220 0.7 kg Main Card

CLK-MV Installed on MC-MV; External


3-1 3W 65 × 22 × 80 0.1 kg
(Type 001) Clock IN/OUT, 1588v2 BC
CLK-MV Installed on MC-MV; External
3-2 1W 65 × 22 × 80 0.1 kg
(Type 002) Clock IN/OUT
4 PS-MV —— 150 × 22 × 220 0.4 kg Power Supply
5 TERM-MV 3W 100 × 22 × 220 0.2 kg Term Card
FAN-MV Cooling Fan (Standard Type,
6-1 6W 30 × 66 × 220 0.6 kg
(Type 001/003) Original)
FAN-MV High-Powered Colling Fan (for Using
6-2 17 W 30 × 66 × 220 0.6 kg
(Type 002) MODEM-AV)

MODEM-A ODU Interface


7-1 17 W 100 × 22 × 220 0.4 kg NOTE 1: MODEM-A is currently
not available in MPLS-TP mode.
7-2 MODEM-EA 14 W 100 × 22 × 220 0.4 kg ODU Interface
MODEM-AV ODU Interface
7-3 35 W 100 × 22 × 220 0.5 kg NOTE 2: MODEM-AV is currently
not available in MPLS-TP mode.
8 16E1-A 8W 100 × 22 × 220 0.4 kg 16 × E1 Interface
9 STM1-A 8 W★ 100 × 22 × 220 0.4 kg STM-1 Interface; Class 1 Product

GbE-A 4×GbE [2×SFP + 2×RJ45];


10 8 W★ 100 × 22 × 220 0.4 kg
Class 1 Product
XGbE-MV 1 × XGbE [SFP+]; Class 1 Product
11 8 W★ 100 × 22 × 220 0.4 kg NOTE 3: XGbE is currently not
available in MPLS-TP mode.
12 MSE-A 10 W 100 × 22 × 220 0.4 kg Multi Service Engine for PWE
13 SFP+ 2W 14 × 10 × 57 0.015 kg On XGbE Ports
14 SFP 1W 14 × 10 × 57 0.015 kg On STM-1 Ports, GbE Ports
15 CWDMFA 0W 100 × 22 × 210 0.4 kg Class 1/1M Laser Product
16 CWDMFB 0W 100 × 22 × 210 0.4 kg Class 1/1M Laser Product
CWDMF Box
17 —— 433 × 32 × 200 1.2 kg Supporting Frame for CWDM
Mount
★: The value does not include that of SFP/SFP+ modules.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
3-2 SYSTEM PERFORMANCES

3.2 Environmental Conditions

3.2.1 Temperature

Condition Requirements

Operating –5 to +50°C
Reference: –5 to+45°C by ETSI EN 300 019-1-3
Class 3.1E in the EU market

Transportation –40 to +70°C (ETSI EN 300 019-1-2 Class 2.3)

Storage –25 to +55°C (ETSI EN 300 019-1-1 Class 1.2)

3.2.2 Humidity

Condition Requirements

Operating Up to 95% (at +50°C, no condensing)


Reference: ETSI EN 300 019-1-3 Class 3.1E in the
EU market

Transportation ETSI 300 019-1-2 Class 2.3

Storage ETSI 300 019-1-1 Class 1.2

GGS-000376-06E IPASOLINK VR 10: SPECIFICATIONS


Submission Prohibited
NEC Group Internal Use Only
SYSTEM PERFORMANCES 3-3

3.3 Power Line Requirements

3.3.1 Input Voltage and Connector

Condition Requirements

Input Voltage Range –48 V DC (–40.5 to –57 V DC)


ETSI EN 300 132-2

Connector 10-Pin, 3.81 mm Pitch [1-178288-8]

3.3.2 Rated Current

Rated current is indicated on the equipment label:

here

The rated current for iPASOLINK VR 10, which previously was 23 A, has been
changed to 27 A since July 2016 due to newly added systems and functions.

iPASOLINK VR 10: SPECIFICATIONS GGS-000376-06E


Submission Prohibited
NEC Group Internal Use Only
3-4/END SYSTEM PERFORMANCES

3.4 Others
Category Standards

EMC Conforms to ETSI EN 301 489-1, ETSI EN 301 489-4,


EN 55022, EN 55024, Class A

LVD Conforms to EN 60950-1, IEC 60950-1, UL 60950,


EN 50385

Spectrum Conforms to ETSI EN 302 217-2-2

GGS-000376-06E iPASOLINK VR 10: SPECIFICATIONS