Exciter Drive Line Report

CLIENT/PROJECT: FLUOR / SOCIEDAD MINERA CERRO VERDE . DATE: 17/09/2014


SCREEN SIZE: BRU - 2 - 3685B - 3 x HE 150 LS. JOB #: SN-100462
PROCESS/DUTY: Ball Mill Feed Screen. SERIAL#:
MINE SERIAL #: Screen C2 - 3310 - SC - proyecto

Drive Side Drive Side


1581 1581
2132

278 826 276


823

277 823 826 276

2130

1580 1583

RIGHT HAND SIDE LEFT HAND SIDE

Bearing Cover Temperature (°C)

Exciter LH Exciter Central Exciter RH Exciter


Serial #: HE15-0331 Serial #: HE15-0320 Serial #: HE15-0303
Time of Ambient
readings Temp. (°C) A B C D A B C D A B C D

Start: 10:10:00 a.m. 18.1


11:20:00 p.m. 18.3 55.4 55.5 58.2 58.8 55.8 55.6 59.4 59 55.2 55.4 57.9 58.4

12:30:00 p.m. 19.2 65.3 65.4 71.6 71 65.4 65.9 72.5 71.8 65.9 65.3 71 70.5

13:40:00 p.m. 21.1 68.7 69.7 75.5 74.5 69.6 69.6 76 76.5 69.4 69.3 74.6 74.4

14:45:00 p.m. 22.1 70.2 69.5 75.7 75.2 70.1 70.2 75.6 75.7 70.8 69.5 75.2 75.3

Motor: Motor de Prueba. 135 Kw. Power (kW): 135

Rated RPM: 840 Actual RPM: 6 Rated Amps: Run Amps:

Stroke Req'd: 11 mm Stroke Actual: 8 11.1 mm

Number and type of Inserts: Lead: Steel: 2 Hollow: 1

Exciter Type: HE 150 LS. Exciter Angle: 45

Oil Level: OK. Litres of Oil: 8

Dipstick location: "Z" Dipstick Graduations: 256 mm +/- 13 mm

Inspected by: Date: Eng. Approval: Date:

QSE Form 8027 Rev 3 Page 1 of 2


Exciter Drive Line Report

RH LH
C
PRE-LOADED
MATERIAL
FLOW
DIRECTION

A
B

FOR GEARED EXCITERS RH Exciter Central Exciter LH Exciter

Location RH LH RH LH RH LH

198 198 198 198 197 197


Dimension A
995 995 995 996 996 996
Dimension B

Dimension C

Relative C/Weight Alignment (deg)

FOR NON-GEARED EXCITERS RH Exciter Central Exciter LH Exciter

Location A B C D A B C D A B C D

LONG SHAFT - LONG SHAFT

SHORT SHAFT - SHORT SHAFT

ENERGY USAGE INSTRUCTIONS:

MAX Starting Current: 146 Amps (Refer to the METER instructions to do specific tasks)

1.) Zero the meter

Power Draw: KW 2.) Start the screen

3.) Record the MAX current in Amps

4.) Record the Power currently being drawn in KW.

Inspected by: Ivan Lupa Mamani Date: 17/09/2014 Eng. Approval: Date: