Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

PROPOSED BUS STAND AT MINI

SMART CITY CHANDIYA


M/S:- ATUL KURARIYA
M.P.URBAN DEVELOPMENT CO.LTD., BHOPAL (M.P.)
DWG.NO.:- MPUDCL/MSC/CHANDIYA/A.K./21/12 NOTES:-
736(ANCHORAGE)

736(ANCHORAGE)
1.READ THIS DRAWING IN CONJUCTION WITH RELEVANT
ARCHITECTURAL/SERVICE DRAWINGS.
2.ALL DIMENSIONS & LEVELS ARE IN MM. UNLESS NOTED OTHERWISE.
4 1 2 3 6 1 7 3.DO NOT SCALE THE DRAWING. READ FIGURED DIMENSIONS ONLY.

600 600 400 DESIGN CAPACITY:-


6400 5500 300 300 300 300
4.FOUNDATION HAS BEEN DESIGNED CONSIDERING A NET SAFE
1600 1600 BEARING CAPACITY OF 150 KN/SQ.M. AT 2.5 M DEPTH
4-T16 4-T12 4-T16 4-T16
4-T16 4-T12 4-T16 CONCRETE:-

500

500

500

500
STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 5.GRADE OF CONCRETE FOR ALL BUILDING WORK, RE WALL AND DRAIN
SHALL BE M-20. UNLESS NOTED OTHERWISE.
3-T16 3-T16 3-T16 3-T16 6.GRADE OF CONCRETE FOR ALL ROAD WORK SHALL BE M-40.
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 (LOC: 0 TO 1600) (LOC: 1600 TO 4800) (LOC: 4800 TO 6400) B101
UNLESS NOTED OTHERWISE.

33-2L-T8 29-2L-T8 SECTION 1-1 (B100 TO B133) SECTION 2-2 (B100 TO B133) SECTION 3-3 (B100 TO B133) (SCALE 1:25)
REINFORCING STEEL:-
@200 C/C @200 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
7.ALL REINFORCEMENT BARS SHALL BE HIGH YEILD STRENGTH
DEFORMED BARS OF GRADE Fe-415 CONFORMING TO 1786:2008 WITH
1 2 3 1 A MINIMUM YEILD STRENGTH OF 415 N/SQMM.
C60 C30 C5 COVER:-
B100 TO B133 :300x500 B101:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) 8.CLEAR COVER TO MAIN R/F SHALL BE:-
a.) FOOTING = 50 MM.
b.) FOOTING (SIDE) = 50 MM.
c.) PEDESTAL = 40 MM.
736(ANCHORAGE)

736(ANCHORAGE)

d.) COLUMN = 40 MM.


e.) BEAM = 25 MM.

736(ANCHORAGE)

736(ANCHORAGE)
f.) SLAB = 20 MM.
6 1 2 3 7
600 400 300 300 300 BEAM - COLUMN JUNCTIONS:-
5500 6 1 2 3 7
300 300 300 9.AT BEAM & COLUMN JUNCTIONS BEAM BARS IF IN CONFLICT WITH
1375 1375 3-T16 3-T12 3-T16 600 5500 400 COLUMN BARS, SHALL BE GRADUALLY BENT & PLACED CLEAR OFF
STP 2L-T8 STP 2L-T8 STP 2L-T8 3-T16 3-T12 3-T16 COLUMN BARS. UNDER NO CIRCUMSTANCES COLUMN VERTICAL
500

500

500
3-T16 3-T12 3-T16 SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF 1375 1375 STP 2L-T8 STP 2L-T8 STP 2L-T8 BARS SHALL BE BENT TO ACCOMMODATE BEAM BARS.

500

500

500
1 - T10 EF
3-T16 3-T16 3-T16 3-T16 3-T12 3-T16 SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF 10.EXTRA TOP OR BENT UP BARS SHALL BE EXTENDED UPTO 0.3 x L IN
ADJACENT SPAN OVER A CONTINOUS SUPPORT. IF EXTRA TOP ARE
(LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500) 1 - T10 EF 3-T16 3-T16 3-T16
736(ANCHORAGE)

736(ANCHORAGE)

NOT PROVIDED THEN ANCHOR DOWN AT THE END SUPPORT.


3-T16
SECTION 1-1 (B140) SECTION 2-2 (B140) SECTION 3-3 (B140) (LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500)
12-2L-T8 9-2L-T8 12-2L-T8 CONSTRUCTION DETAILS:-

736(ANCHORAGE)

736(ANCHORAGE)
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) 3-T16 SECTION 1-1 (B146) SECTION 2-2 (B146) SECTION 3-3 (B146)
@180 C/C @200 C/C @180 C/C 12-2L-T8 9-2L-T8 12-2L-T8 11.LAP LENGTH & BOND LENGTH SHALL BE AS PER IS 456: 2000.
1833 1833 (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
@180 C/C @200 C/C @180 C/C 12.LAPPING OF BARS SHALL BE STAGGERED. AT ANY CROSS SECTION
C48 1 2 3 C23 1833 1833 NOT MORE THAN 50% OF THE BARS SHALL BE LAPPED.
13.LAPPING OF R/F BARS IN BEAMS & SLABS SHALL BE AVOIDED IN
B140:300x500 C49 1 2 3 C24 THE FOLLOWING CASES.
(SCALE: H = 1:50 / V = 1:50)
B146:300x500 a.) TOP BARS NEAR SUPPORT b.) BOTTOM BARS AT MIDSPAN
14.OVERLAP OF BARS IS NOT PERMITTED IN HANGERS.
736(ANCHORAGE)

736(ANCHORAGE)
15.STIRRUPS FOR CANTILEVER BEAMS TO HAVE HOOKS AT BOTTOM
16.ANY TYPE OF OPENINGS (CUTOUT/BLOCKOUT) SHALL BE MATCHED
1 1 2 1 3 1 4 1 5 1 6 1 2 3 7 WITH THE SERVICES DRAWINGS.
300 3200 300 3200 300 3050 600 3050 300 3050 600 5500 400 300 300 300 300 17.COLUMN REBARS SHALL BE BENT AT CHANGE OF SECTION WITH
SLOPE OF (1:6) AS AND WHERE REQUIRED.
1375 1375 3-T16 3-T16 3-T12 3-T16
3-T16 3-T12 3-T16 AREA OF STATETMENT

500

500

500

500
STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8
3-T16 3-T16 3-T16 3-T16 11853.0 SQ.M
Total plot area
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 B134 TO B138 (LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500)
17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 29-2L-T8 (SCALE 1:25) SECTION 1-1 (B139) SECTION 2-2 (B139) SECTION 3-3 (B139)
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
1 1 1 1 1 1 2 3 Total builtup area 11376.0 SQ.M
C95 C89 C83 C77 C54 C47 C22
B134:300x500 B135:300x500 B136:300x500 B137:300x500 B138:300x500 B139:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
Bus stand building area 1450.0 SQ.M
736(ANCHORAGE)

736(ANCHORAGE)

Boundary wall length 453.0M


1 1 1 1 1

300
1 2
300 300
3 4
300
5
300
6
300 300 300 CLIENT'S SEAL & SIGN
3200 3200 3200 3200 3200
3-T16 3-T16
500

500
3-T16 STP 2L-T8 STP 2L-T8
3-T16 3-T16
736(ANCHORAGE)

736(ANCHORAGE)

3-T16 B141 TO B145 B142


17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 (SCALE 1:25) (SCALE 1:25)
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C B43

C96
1
C90
1
C84
1
C78
1
C55
1 APPROVAL AGENCY SEAL & SIGN
B141:300x500 B142:300x500 B143:300x500 B144:300x500 B145:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
736(ANCHORAGE)

1 1 1 1 1 1 2 3
736(ANCHORAGE)
1 2 3 4 5 6 7
300 3200 300 3200 300 3200 300 3200 300 3050 600 5500 400

1375 1375
3-T16 3-T12 3-T16 all dimensions are in mm
1 - T10 EF
scale NTS dwg.no.:- 12
736(ANCHORAGE)

736(ANCHORAGE)

3-T16
17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 12-2L-T8 9-2L-T8 12-2L-T8
date 31-01-21
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @180 C/C @200 C/C @180 C/C dealt
1833 1833

C97 1 C91 1 C85 1 C79 1 C56 1 C50 1 2 3 C25 appd. Ankesh


B147:300x500 B148:300x500 B149:300x500 B150:300x500 B151:300x500 B152:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)

AATVIK CONSULTANCY
300 300 300 300 300 300 300 300 &
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 3-T12 3-T16
INFRASTRUCTURE LLP Foundation of Excellence
STP 2L-T8 STP 2L-T8 STP 2L-T8 Add-95 Rachna nagar bhopal (M.P)
500

500

500

500

500

500

500

500
STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 3-T16
Email ID- aatvik.aatvik@gmail.com
B147 B148 B149 B150 B151 (LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500) Mob No-9425463303
1. DO NOT SCALE THE DRAWING AND NOT COUNT THE BARS
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) SECTION 1-1 (B152) SECTION 2-2 (B152) SECTION 3-3 (B152) 2. ALL DIMENSIONS ARE IN MILI METER
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) 3. S.B.C. OF SOIL = 150.0 KN/Sq.M
4. DEPTH OF FOUNDATION - 2.5 METER

this drg.is property of architects and is not to


be used or reproduced without their prior
GROUND BEAM DETAIL-5 written permission.
PROPOSED BUS STAND AT MINI
SMART CITY CHANDIYA
M/S:- ATUL KURARIYA
M.P.URBAN DEVELOPMENT CO.LTD., BHOPAL (M.P.)
DWG.NO.:- MPUDCL/MSC/CHANDIYA/A.K./21/11 NOTES:-
1.READ THIS DRAWING IN CONJUCTION WITH RELEVANT
736(ANCHORAGE)

736(ANCHORAGE)
ARCHITECTURAL/SERVICE DRAWINGS.
2.ALL DIMENSIONS & LEVELS ARE IN MM. UNLESS NOTED OTHERWISE.
3.DO NOT SCALE THE DRAWING. READ FIGURED DIMENSIONS ONLY.
W 1 2 3 Y 1 2 3 A1
300 300 300 300 300 300 DESIGN CAPACITY:-
600 5400 600 5500 400
4.FOUNDATION HAS BEEN DESIGNED CONSIDERING A NET SAFE
1350 1350 1375 1375 3-T16 3-T12 3-T16 3-T16 3-T12 3-T16 BEARING CAPACITY OF 150 KN/SQ.M. AT 2.5 M DEPTH
STP 2L-T8 STP 2L-T8 STP 2L-T8

500

500

500

500

500

500
3-T16 3-T12 3-T16 3-T12 3-T16 STP 2L-T8 STP 2L-T8 STP 2L-T8 SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF CONCRETE:-
1 - T10 EF
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 5.GRADE OF CONCRETE FOR ALL BUILDING WORK, RE WALL AND DRAIN
SHALL BE M-20. UNLESS NOTED OTHERWISE.
(LOC: 0 TO 1350) (LOC: 1350 TO 4050) (LOC: 4050 TO 5400) (LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500)
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 6.GRADE OF CONCRETE FOR ALL ROAD WORK SHALL BE M-40.
SECTION 1-1 (B79) SECTION 2-2 (B79) SECTION 3-3 (B79) SECTION 1-1 (B80) SECTION 2-2 (B80) SECTION 3-3 (B80) UNLESS NOTED OTHERWISE.
28-2L-T8 12-2L-T8 19-2L-T8
@200 C/C @180 C/C @200 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) REINFORCING STEEL:-
3667
7.ALL REINFORCEMENT BARS SHALL BE HIGH YEILD STRENGTH
C95 C96 C97 DEFORMED BARS OF GRADE Fe-415 CONFORMING TO 1786:2008 WITH
1 2 3 1 2 3
A MINIMUM YEILD STRENGTH OF 415 N/SQMM.
B79:300x500 B80:300x500 COVER:-
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
8.CLEAR COVER TO MAIN R/F SHALL BE:-
a.) FOOTING = 50 MM.
b.) FOOTING (SIDE) = 50 MM.
c.) PEDESTAL = 40 MM.
d.) COLUMN = 40 MM.
736(ANCHORAGE)

736(ANCHORAGE)
e.) BEAM = 25 MM.
f.) SLAB = 20 MM.
1 1 2 1 3 1 4 1 5 1 6 1 2 3 7
BEAM - COLUMN JUNCTIONS:-
300 300 300 300 300 600 400 300 300
3200 3200 3200 3200 3050 5500 9.AT BEAM & COLUMN JUNCTIONS BEAM BARS IF IN CONFLICT WITH
1375 1375 3-T16 3-T16 COLUMN BARS, SHALL BE GRADUALLY BENT & PLACED CLEAR OFF
COLUMN BARS. UNDER NO CIRCUMSTANCES COLUMN VERTICAL
3-T16 3-T12 3-T16

500

500
STP 2L-T8 STP 2L-T8 BARS SHALL BE BENT TO ACCOMMODATE BEAM BARS.
1 - T10 EF 10.EXTRA TOP OR BENT UP BARS SHALL BE EXTENDED UPTO 0.3 x L IN
3-T16 3-T16 ADJACENT SPAN OVER A CONTINOUS SUPPORT. IF EXTRA TOP ARE
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 B81 B82 NOT PROVIDED THEN ANCHOR DOWN AT THE END SUPPORT.
17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 12-2L-T8 9-2L-T8 12-2L-T8 (SCALE 1:25) (SCALE 1:25) CONSTRUCTION DETAILS:-
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @180 C/C @200 C/C @180 C/C
1833 1833 11.LAP LENGTH & BOND LENGTH SHALL BE AS PER IS 456: 2000.
12.LAPPING OF BARS SHALL BE STAGGERED. AT ANY CROSS SECTION
C92 1 C86 1 C80 1 C57 1 C51 1 C26 1 2 3 C1 NOT MORE THAN 50% OF THE BARS SHALL BE LAPPED.
B81:300x500 B82:300x500 B83:300x500 B84:300x500 B85:300x500 B86:300x500 13.LAPPING OF R/F BARS IN BEAMS & SLABS SHALL BE AVOIDED IN
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) THE FOLLOWING CASES.
a.) TOP BARS NEAR SUPPORT b.) BOTTOM BARS AT MIDSPAN
14.OVERLAP OF BARS IS NOT PERMITTED IN HANGERS.
15.STIRRUPS FOR CANTILEVER BEAMS TO HAVE HOOKS AT BOTTOM
300 300 300 300 300 300 16.ANY TYPE OF OPENINGS (CUTOUT/BLOCKOUT) SHALL BE MATCHED
WITH THE SERVICES DRAWINGS.
17.COLUMN REBARS SHALL BE BENT AT CHANGE OF SECTION WITH
3-T16 3-T16 3-T16 3-T16 3-T12 3-T16 SLOPE OF (1:6) AS AND WHERE REQUIRED.
STP 2L-T8 STP 2L-T8 STP 2L-T8
500

500

500

500

500

500
STP 2L-T8 STP 2L-T8 STP 2L-T8 SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF AREA OF STATETMENT
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 Total plot area 11853.0 SQ.M
B83 B84 B85 (LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500)
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) SECTION 1-1 (B86) SECTION 2-2 (B86) SECTION 3-3 (B86) 11376.0 SQ.M
Total builtup area
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
Bus stand building area 1450.0 SQ.M
736(ANCHORAGE)

736(ANCHORAGE)

6 1 2 3 7 Boundary wall length 453.0M


600 400 300 300 300
5500 CLIENT'S SEAL & SIGN
1375 1375 3-T16 3-T12 3-T16
STP 2L-T8 STP 2L-T8 STP 2L-T8
500

500

500

3-T16 3-T12 3-T16 SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF


1 - T10 EF
3-T16 3-T16 3-T16
(LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500)
736(ANCHORAGE) 736(ANCHORAGE)

736(ANCHORAGE)

3-T16
12-2L-T8 9-2L-T8 12-2L-T8 SECTION 1-1 (B87) SECTION 2-2 (B87) SECTION 3-3 (B87)
@180 C/C @200 C/C @180 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
1833 1833
APPROVAL AGENCY SEAL & SIGN
C27 1 2 3 C2
B87:300x500
(SCALE: H = 1:50 / V = 1:50)
736(ANCHORAGE)

1 1 2 1 3 1 4 1 5 1 6
300 300 300 300 300
300 3200 300 3200 300 3200 300 3200 300 3200 300
3-T16 3-T16 3-T16 3-T16 3-T16
500

500

500

500

500
3-T16 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 all dimensions are in mm
3-T16 3-T16 3-T16 3-T16 3-T16
B88 B89 B90 B91 B92
scale NTS dwg.no.:- 11
736(ANCHORAGE)

736(ANCHORAGE)

3-T16
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) date 31-01-21
17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C B24 dealt
1 1 1 1 1
C93
B88:300x500
C87
B89:300x500
C81
B90:300x500
C58
B91:300x500
C52
B92:300x500
appd. Ankesh
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
736(ANCHORAGE)

736(ANCHORAGE)

AATVIK CONSULTANCY
1 1 2 1 3 1 4 1 5 1 6 1 2 3 7 &
300 300 300 600 300 600 400 300 300 300 300 300
3200 3200 3050 3050 3050 5500 INFRASTRUCTURE LLP Foundation of Excellence
1375 1375 3-T16 3-T16 3-T16 3-T16 3-T16
Add-95 Rachna nagar bhopal (M.P)
500

500

500

500
3-T16 3-T12 3-T16 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8
Email ID- aatvik.aatvik@gmail.com
3-T16 3-T16 3-T16 3-T16 3-T16
B94 B95 B96 B97 B98 Mob No-9425463303
736(ANCHORAGE)

736(ANCHORAGE)

3-T16 1. DO NOT SCALE THE DRAWING AND NOT COUNT THE BARS
17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 17-2L-T8 29-2L-T8 (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) 2. ALL DIMENSIONS ARE IN MILI METER
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C 3. S.B.C. OF SOIL = 150.0 KN/Sq.M
500

4. DEPTH OF FOUNDATION - 2.5 METER


1 1 1 1 1 1 2 3
C94
B94:300x500
C88
B95:300x500
C82
B96:300x500
C59
B97:300x500
C53
B98:300x500
C29
B99:300x500
C4 this drg.is property of architects and is not to
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) be used or reproduced without their prior
GROUND BEAM DETAIL-4 written permission.
PROPOSED BUS STAND AT MINI
SMART CITY CHANDIYA
M/S:- ATUL KURARIYA
M.P.URBAN DEVELOPMENT CO.LTD., BHOPAL (M.P.)
DWG.NO.:- MPUDCL/MSC/CHANDIYA/A.K./21/010 NOTES:-
1.READ THIS DRAWING IN CONJUCTION WITH RELEVANT
ARCHITECTURAL/SERVICE DRAWINGS.
2.ALL DIMENSIONS & LEVELS ARE IN MM. UNLESS NOTED OTHERWISE.
3.DO NOT SCALE THE DRAWING. READ FIGURED DIMENSIONS ONLY.
DESIGN CAPACITY:-
300 300 300 300 300 300 300 300 300 300
4.FOUNDATION HAS BEEN DESIGNED CONSIDERING A NET SAFE
3-T16 3-T12 3-T16 3-T16 3-T16 3-T12 3-T16 3-T16 3-T12 3-T16 BEARING CAPACITY OF 150 KN/SQ.M. AT 2.5 M DEPTH
500

500

500

500

500

500

500

500

500

500
STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 CONCRETE:-
5.GRADE OF CONCRETE FOR ALL BUILDING WORK, RE WALL AND DRAIN
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 SHALL BE M-20. UNLESS NOTED OTHERWISE.
(LOC: 0 TO 925) (LOC: 925 TO 2775) (LOC: 2775 TO 3700) B66 (LOC: 0 TO 1390) (LOC: 1390 TO 4160) (LOC: 4160 TO 5550) (LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500) 6.GRADE OF CONCRETE FOR ALL ROAD WORK SHALL BE M-40.
SECTION 1-1 (B65) SECTION 2-2 (B65) SECTION 3-3 (B65) (SCALE 1:25) SECTION 1-1 (B67) SECTION 2-2 (B67) SECTION 3-3 (B67) SECTION 1-1 (B68) SECTION 2-2 (B68) SECTION 3-3 (B68) UNLESS NOTED OTHERWISE.
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) REINFORCING STEEL:-
7.ALL REINFORCEMENT BARS SHALL BE HIGH YEILD STRENGTH
DEFORMED BARS OF GRADE Fe-415 CONFORMING TO 1786:2008 WITH
A MINIMUM YEILD STRENGTH OF 415 N/SQMM.
COVER:-
8.CLEAR COVER TO MAIN R/F SHALL BE:-
a.) FOOTING = 50 MM.
b.) FOOTING (SIDE) = 50 MM.
c.) PEDESTAL = 40 MM.
736(ANCHORAGE)

736(ANCHORAGE)
d.) COLUMN = 40 MM.
e.) BEAM = 25 MM.
1 2 3 1 2 3 f.) SLAB = 20 MM.
A C E
400 5500 600 5400 600 300 300 300 300 300 300 BEAM - COLUMN JUNCTIONS:-
9.AT BEAM & COLUMN JUNCTIONS BEAM BARS IF IN CONFLICT WITH
1375 1375 1350 1350 3-T16 3-T12 3-T16 3-T16 3-T12 3-T16 COLUMN BARS, SHALL BE GRADUALLY BENT & PLACED CLEAR OFF
3-T16 3-T12 3-T16 3-T12 3-T16 COLUMN BARS. UNDER NO CIRCUMSTANCES COLUMN VERTICAL

500

500

500

500

500

500
STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 BARS SHALL BE BENT TO ACCOMMODATE BEAM BARS.
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 10.EXTRA TOP OR BENT UP BARS SHALL BE EXTENDED UPTO 0.3 x L IN
ADJACENT SPAN OVER A CONTINOUS SUPPORT. IF EXTRA TOP ARE
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 (LOC: 0 TO 1375) (LOC: 1375 TO 4125) (LOC: 4125 TO 5500) (LOC: 0 TO 1350) (LOC: 1350 TO 4050) (LOC: 4050 TO 5400) NOT PROVIDED THEN ANCHOR DOWN AT THE END SUPPORT.
29-2L-T8 28-2L-T8 SECTION 1-1 (B69) SECTION 2-2 (B69) SECTION 3-3 (B69) SECTION 1-1 (B70) SECTION 2-2 (B70) SECTION 3-3 (B70) CONSTRUCTION DETAILS:-
@200 C/C @200 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
11.LAP LENGTH & BOND LENGTH SHALL BE AS PER IS 456: 2000.
1 2 3 1 2 3
C80 C81 C82 12.LAPPING OF BARS SHALL BE STAGGERED. AT ANY CROSS SECTION
B69:300x500 B70:300x500 NOT MORE THAN 50% OF THE BARS SHALL BE LAPPED.
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) 13.LAPPING OF R/F BARS IN BEAMS & SLABS SHALL BE AVOIDED IN
THE FOLLOWING CASES.
a.) TOP BARS NEAR SUPPORT b.) BOTTOM BARS AT MIDSPAN
736(ANCHORAGE)

736(ANCHORAGE)

14.OVERLAP OF BARS IS NOT PERMITTED IN HANGERS.


15.STIRRUPS FOR CANTILEVER BEAMS TO HAVE HOOKS AT BOTTOM
W 1 2 3 Y 1 2 3 A1 16.ANY TYPE OF OPENINGS (CUTOUT/BLOCKOUT) SHALL BE MATCHED
600 600 400 WITH THE SERVICES DRAWINGS.
5400 5500 300 300 300 300 300 300
17.COLUMN REBARS SHALL BE BENT AT CHANGE OF SECTION WITH
1350 1350 1375 1375 3-T16 3-T12 3-T16 3-T16 3-T12 3-T16 SLOPE OF (1:6) AS AND WHERE REQUIRED.
3-T16 3-T12 3-T16 3-T12 3-T16
500

500

500

500

500

500
STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 AREA OF STATETMENT
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16
Total plot area 11853.0 SQ.M
736(ANCHORAGE)

736(ANCHORAGE)

3-T16 (LOC: 0 TO 1350) (LOC: 1350 TO 4050) (LOC: 4050 TO 5400) (LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500)
28-2L-T8 29-2L-T8 SECTION 1-1 (B71) SECTION 2-2 (B71) SECTION 3-3 (B71) SECTION 1-1 (B72) SECTION 2-2 (B72) SECTION 3-3 (B72)
@200 C/C @200 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
1 2 3 1 2 3
C83
B71:300x500
C84
B72:300x500
C85 Total builtup area 11376.0 SQ.M
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)

Bus stand building area 1450.0 SQ.M


736(ANCHORAGE)

736(ANCHORAGE)

Boundary wall length 453.0M


A 1 2 3 C 1 2 3 E
400 5500 600 5400 600 300 300 300 300 300 300 CLIENT'S SEAL & SIGN
1375 1375 1350 1350 3-T16 3-T12 3-T16 3-T16 3-T12 3-T16
3-T16 3-T12 3-T16 3-T12 3-T16
500

500

500

500

500

500
STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16
736(ANCHORAGE)

736(ANCHORAGE)

3-T16 (LOC: 0 TO 1375) (LOC: 1375 TO 4125) (LOC: 4125 TO 5500) (LOC: 0 TO 1350) (LOC: 1350 TO 4050) (LOC: 4050 TO 5400)
29-2L-T8 28-2L-T8 SECTION 1-1 (B73) SECTION 2-2 (B73) SECTION 3-3 (B73) SECTION 1-1 (B74) SECTION 2-2 (B74) SECTION 3-3 (B74)
@200 C/C @200 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
1 2 3 1 2 3
C86 C87 C88
B73:300x500 B74:300x500 APPROVAL AGENCY SEAL & SIGN
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
736(ANCHORAGE)

736(ANCHORAGE)

W 1 2 3 Y 1 2 3 A1
600 5400 600 5500 400 300 300 300 300 300 300
1350 1350 1375 1375
3-T16 3-T12 3-T16 3-T16 3-T12 3-T16
3-T16 3-T12 3-T16 3-T12 3-T16
500

500

500

500

500

500
STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 all dimensions are in mm
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16
736(ANCHORAGE)

736(ANCHORAGE)

3-T16 (LOC: 0 TO 1350) (LOC: 1350 TO 4050) (LOC: 4050 TO 5400) (LOC: 0 TO 1375) (LOC: 1375 TO 4126) (LOC: 4126 TO 5500) scale NTS dwg.no.:- 10
28-2L-T8 29-2L-T8 SECTION 1-1 (B75) SECTION 2-2 (B75) SECTION 3-3 (B75) SECTION 1-1 (B76) SECTION 2-2 (B76) SECTION 3-3 (B76)
@200 C/C @200 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) date 31-01-21
1 2 3 1 2 3
C89
B75:300x500
C90
B76:300x500
C91 dealt
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
appd. Ankesh
736(ANCHORAGE)

736(ANCHORAGE)

AATVIK CONSULTANCY
A 1 2 3 C 1 2 3 E &
400 5500 600 5400 600 INFRASTRUCTURE LLP Foundation of Excellence
300 300 300 300 300 300
1375 1375 1350 1350 Add-95 Rachna nagar bhopal (M.P)
3-T16 3-T12 3-T16 3-T16 3-T12 3-T16
3-T16 3-T12 3-T16 3-T12 3-T16 STP 2L-T8 STP 2L-T8 STP 2L-T8
Email ID- aatvik.aatvik@gmail.com
500

500

500

500

500

500
1 - T10 EF SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF STP 2L-T8 STP 2L-T8 STP 2L-T8
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 Mob No-9425463303
736(ANCHORAGE)

736(ANCHORAGE)

3-T16 (LOC: 0 TO 1375) (LOC: 1375 TO 4125) (LOC: 4125 TO 5500) (LOC: 0 TO 1350) (LOC: 1350 TO 4050) (LOC: 4050 TO 5400)
1. DO NOT SCALE THE DRAWING AND NOT COUNT THE BARS
2. ALL DIMENSIONS ARE IN MILI METER
12-2L-T8 9-2L-T8 12-2L-T8 28-2L-T8 SECTION 1-1 (B77) SECTION 2-2 (B77) SECTION 3-3 (B77) SECTION 1-1 (B78) SECTION 2-2 (B78) SECTION 3-3 (B78) 3. S.B.C. OF SOIL = 150.0 KN/Sq.M
@180 C/C @200 C/C @180 C/C @200 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) 4. DEPTH OF FOUNDATION - 2.5 METER
1833 1833

C92 C93 C94


this drg.is property of architects and is not to
1 2 3 1 2 3
be used or reproduced without their prior
B77:300x500 B78:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) GROUND BEAM DETAIL-3 written permission.
PROPOSED BUS STAND AT MINI
SMART CITY CHANDIYA
M/S:- ATUL KURARIYA
M.P.URBAN DEVELOPMENT CO.LTD., BHOPAL (M.P.)
DWG.NO.:- MPUDCL/MSC/CHANDIYA/A.K./21/09 NOTES:-
736(ANCHORAGE)

736(ANCHORAGE)
1.READ THIS DRAWING IN CONJUCTION WITH RELEVANT
ARCHITECTURAL/SERVICE DRAWINGS.
A 1 2 3 C 1 2 3 E 2.ALL DIMENSIONS & LEVELS ARE IN MM. UNLESS NOTED OTHERWISE.
3.DO NOT SCALE THE DRAWING. READ FIGURED DIMENSIONS ONLY.
400 5500 600 5400 600 300 300 300 300 300 300
DESIGN CAPACITY:-
1375 1375 1350 1350 3-T16 3-T12 3-T16 3-T16 3-T12 3-T16 4.FOUNDATION HAS BEEN DESIGNED CONSIDERING A NET SAFE
3-T16 3-T12 3-T16 3-T12 3-T16 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 BEARING CAPACITY OF 150 KN/SQ.M. AT 2.5 M DEPTH

500

500

500

500

500

500
SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF
1 - T10 EF 1 - T10 EF CONCRETE:-
3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 5.GRADE OF CONCRETE FOR ALL BUILDING WORK, RE WALL AND DRAIN
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 (LOC: 0 TO 1375) (LOC: 1375 TO 4125) (LOC: 4125 TO 5500) (LOC: 0 TO 1350) (LOC: 1350 TO 4050) (LOC: 4050 TO 5400) SHALL BE M-20. UNLESS NOTED OTHERWISE.
SECTION 1-1 (B45) SECTION 2-2 (B45) SECTION 3-3 (B45) SECTION 1-1 (B46) SECTION 2-2 (B46) SECTION 3-3 (B46) 6.GRADE OF CONCRETE FOR ALL ROAD WORK SHALL BE M-40.
12-2L-T8 9-2L-T8 12-2L-T8 11-2L-T8 8-2L-T8 11-2L-T8
UNLESS NOTED OTHERWISE.
@180 C/C @200 C/C @180 C/C @180 C/C @200 C/C @180 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
1833 1833 1800 1800 REINFORCING STEEL:-
7.ALL REINFORCEMENT BARS SHALL BE HIGH YEILD STRENGTH
C51 1 2 3 C52 1 2 3 C53 DEFORMED BARS OF GRADE Fe-415 CONFORMING TO 1786:2008 WITH
B45:300x500 B46:300x500 A MINIMUM YEILD STRENGTH OF 415 N/SQMM.
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) COVER:-
8.CLEAR COVER TO MAIN R/F SHALL BE:-
a.) FOOTING = 50 MM.
b.) FOOTING (SIDE) = 50 MM.
736(ANCHORAGE)

736(ANCHORAGE)
c.) PEDESTAL = 40 MM.
d.) COLUMN = 40 MM.
e.) BEAM = 25 MM.
W 1 2 3 Y 1 A1 f.) SLAB = 20 MM.
600 5400 600 5500 400 300 300 300 300 BEAM - COLUMN JUNCTIONS:-
1350 1350 9.AT BEAM & COLUMN JUNCTIONS BEAM BARS IF IN CONFLICT WITH
3-T16 3-T12 3-T16 3-T16 COLUMN BARS, SHALL BE GRADUALLY BENT & PLACED CLEAR OFF
3-T16 3-T12 3-T16 STP 2L-T8 STP 2L-T8 STP 2L-T8 STP 2L-T8 COLUMN BARS. UNDER NO CIRCUMSTANCES COLUMN VERTICAL

500

500

500

500
1 - T10 EF 1 - T10 EF SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF BARS SHALL BE BENT TO ACCOMMODATE BEAM BARS.
10.EXTRA TOP OR BENT UP BARS SHALL BE EXTENDED UPTO 0.3 x L IN
3-T16 3-T16 3-T16 3-T16 ADJACENT SPAN OVER A CONTINOUS SUPPORT. IF EXTRA TOP ARE
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 (LOC: 0 TO 1350) (LOC: 1350 TO 4050) (LOC: 4050 TO 5400) B48
NOT PROVIDED THEN ANCHOR DOWN AT THE END SUPPORT.
11-2L-T8 8-2L-T8 11-2L-T8 12-2L-T8 9-2L-T8 12-2L-T8 SECTION 1-1 (B47) SECTION 2-2 (B47) SECTION 3-3 (B47) (SCALE 1:25) CONSTRUCTION DETAILS:-
@180 C/C @200 C/C @180 C/C @180 C/C @200 C/C @180 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
1800 1800 1833 1833 11.LAP LENGTH & BOND LENGTH SHALL BE AS PER IS 456: 2000.
12.LAPPING OF BARS SHALL BE STAGGERED. AT ANY CROSS SECTION
C54 1 2 3 C55 1 C56 NOT MORE THAN 50% OF THE BARS SHALL BE LAPPED.
13.LAPPING OF R/F BARS IN BEAMS & SLABS SHALL BE AVOIDED IN
B47:300x500 B48:300x500 THE FOLLOWING CASES.
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) a.) TOP BARS NEAR SUPPORT b.) BOTTOM BARS AT MIDSPAN
736(ANCHORAGE)

736(ANCHORAGE)
14.OVERLAP OF BARS IS NOT PERMITTED IN HANGERS.
15.STIRRUPS FOR CANTILEVER BEAMS TO HAVE HOOKS AT BOTTOM
16.ANY TYPE OF OPENINGS (CUTOUT/BLOCKOUT) SHALL BE MATCHED
A 1 2 3 C 1 2 3 E 1 F 1 2 3 G 1 H WITH THE SERVICES DRAWINGS.
400 600 300 300 300 300 300 300 300
5500 5550 3700 3700 3700 17.COLUMN REBARS SHALL BE BENT AT CHANGE OF SECTION WITH
SLOPE OF (1:6) AS AND WHERE REQUIRED.
1375 1375 1390 1390 925 925 3-T16 3-T12 3-T16

500
AREA OF STATETMENT

500
3-T16 3-T12 3-T16 3-T12 3-T16 3-T12 3-T16 STP 2L-T8

500
STP 2L-T8 STP 2L-T8
3-T16 3-T16 3-T16
(LOC: 4125 TO 5500)
Total plot area 11853.0 SQ.M
(LOC: 1375 TO 4125)
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 (LOC: 0 TO 1375)
SECTION 1-1 (B49) SECTION 2-2 (B49) SECTION 3-3 (B49)
29-2L-T8 29-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)

1 2 3 1 2 3 1 1 2 3 1 Total builtup area 11376.0 SQ.M


C57 C58 C59 C60 C61 C62
B49:300x500 B50:300x500 B51:300x500 B52:300x500 B53:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
Bus stand building area 1450.0 SQ.M

Boundary wall length 453.0M


300 300 300 300 300 300 300 300
CLIENT'S SEAL & SIGN
3-T16 3-T12 3-T16 3-T16 3-T16 3-T12 3-T16 3-T16

500
500

500
500

500

STP 2L-T8 STP 2L-T8


500

STP 2L-T8
500

STP 2L-T8 STP 2L-T8


500

STP 2L-T8 STP 2L-T8 STP 2L-T8


3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 3-T16 3-T16
(LOC: 0 TO 925) (LOC: 925 TO 2775) (LOC: 2775 TO 3700) B53 (LOC: 0 TO 1390) (LOC: 1390 TO 4160) (LOC: 4160 TO 5550) B51
SECTION 1-1 (B52) SECTION 2-2 (B52) SECTION 3-3 (B52) (SCALE 1:25) SECTION 1-1 (B50) SECTION 2-2 (B50) SECTION 3-3 (B50) (SCALE 1:25)
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) APPROVAL AGENCY SEAL & SIGN
736(ANCHORAGE)

736(ANCHORAGE)
I 1 J 1 K 1 L 1 M 1 N 1 O 1 P 1 Q 1 R 1 S
300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 300

3-T16
3-T16

500
STP 2L-T8
all dimensions are in mm
3-T16
scale NTS dwg.no.:- 09
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 B54 TO B63
20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 (SCALE 1:25)
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C date 31-01-21
C63
1
C64
1
C65
1
C66
1
C67
1
C68
1
C69
1
C70
1
C71
1
C72
1
C73
dealt
B54:300x500 B55:300x500 B56:300x500 B57:300x500 B58:300x500 B59:300x500 B60:300x500 B61:300x500 B62:300x500 B63:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) appd. Ankesh
736(ANCHORAGE)

736(ANCHORAGE)

AATVIK CONSULTANCY
T 1 U 1 2 3 V 1 W 1 2 3 Y 1 2 3 A1
&
300 3700 300 3700 300 3700 300 5550 600 5500 400 300 INFRASTRUCTURE LLP Foundation of Excellence
925 925 1390 1390 1375 1375 3-T16 Add-95 Rachna nagar bhopal (M.P)
3-T16 3-T12 3-T16 3-T12 3-T16 3-T12 3-T16 Email ID- aatvik.aatvik@gmail.com
500

STP 2L-T8
3-T16 Mob No-9425463303
1. DO NOT SCALE THE DRAWING AND NOT COUNT THE BARS
736(ANCHORAGE)

736(ANCHORAGE)

3-T16 B64 2. ALL DIMENSIONS ARE IN MILI METER


20-2L-T8 20-2L-T8 20-2L-T8 29-2L-T8 29-2L-T8 (SCALE 1:25) 3. S.B.C. OF SOIL = 150.0 KN/Sq.M
4. DEPTH OF FOUNDATION - 2.5 METER
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C
1 1 2 3 1 1 2 3 1 2 3
this drg.is property of architects and is not to
C74 C75 C76 C77 C78 C79 be used or reproduced without their prior
B64:300x500 B65:300x500 B66:300x500 B67:300x500 B68:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) GROUND BEAM DETAIL-2 written permission.
PROPOSED BUS STAND AT MINI
SMART CITY CHANDIYA
M/S:- ATUL KURARIYA
M.P.URBAN DEVELOPMENT CO.LTD., BHOPAL (M.P.)
DWG.NO.:- MPUDCL/MSC/CHANDIYA/A.K./21/08
736(ANCHORAGE)

736(ANCHORAGE)
NOTES:-
1.READ THIS DRAWING IN CONJUCTION WITH RELEVANT
ARCHITECTURAL/SERVICE DRAWINGS.
A 1 B 1 D 1 E 1 F 1 G 1 H 2.ALL DIMENSIONS & LEVELS ARE IN MM. UNLESS NOTED OTHERWISE.
3.DO NOT SCALE THE DRAWING. READ FIGURED DIMENSIONS ONLY.
300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 DESIGN CAPACITY:-
300
4.FOUNDATION HAS BEEN DESIGNED CONSIDERING A NET SAFE
3-T16 BEARING CAPACITY OF 150 KN/SQ.M. AT 2.5 M DEPTH
3-T16 CONCRETE:-

500
STP 2L-T8 5.GRADE OF CONCRETE FOR ALL BUILDING WORK, RE WALL AND DRAIN
SHALL BE M-20. UNLESS NOTED OTHERWISE.
3-T16 6.GRADE OF CONCRETE FOR ALL ROAD WORK SHALL BE M-40.
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 UNLESS NOTED OTHERWISE.
B1 TO B6
20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 REINFORCING STEEL:-
(SCALE 1:25)
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C 7.ALL REINFORCEMENT BARS SHALL BE HIGH YEILD STRENGTH
DEFORMED BARS OF GRADE Fe-415 CONFORMING TO 1786:2008 WITH
A MINIMUM YEILD STRENGTH OF 415 N/SQMM.
1 1 1 1 1 1
C1 C2 C3 C4 C5 C6 C7 COVER:-
B1:300x500 B2:300x500 B3:300x500 B4:300x500 B5:300x500 B6:300x500 8.CLEAR COVER TO MAIN R/F SHALL BE:-
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) a.) FOOTING = 50 MM.
b.) FOOTING (SIDE) = 50 MM.
c.) PEDESTAL = 40 MM.
d.) COLUMN = 40 MM.
736(ANCHORAGE)

736(ANCHORAGE)
e.) BEAM = 25 MM.
f.) SLAB = 20 MM.
I 1 J 1 K 1 L 1 M 1 N 1 O 1 P 1 Q 1 R 1 S BEAM - COLUMN JUNCTIONS:-
300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 300 9.AT BEAM & COLUMN JUNCTIONS BEAM BARS IF IN CONFLICT WITH
COLUMN BARS, SHALL BE GRADUALLY BENT & PLACED CLEAR OFF
3-T16 COLUMN BARS. UNDER NO CIRCUMSTANCES COLUMN VERTICAL
3-T16

500
BARS SHALL BE BENT TO ACCOMMODATE BEAM BARS.
STP 2L-T8
10.EXTRA TOP OR BENT UP BARS SHALL BE EXTENDED UPTO 0.3 x L IN
3-T16 ADJACENT SPAN OVER A CONTINOUS SUPPORT. IF EXTRA TOP ARE
736(ANCHORAGE)

736(ANCHORAGE)
NOT PROVIDED THEN ANCHOR DOWN AT THE END SUPPORT.
3-T16 B7 TO B16
20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 (SCALE 1:25) CONSTRUCTION DETAILS:-
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C
11.LAP LENGTH & BOND LENGTH SHALL BE AS PER IS 456: 2000.
1 1 1 1 1 1 1 1 1 1 12.LAPPING OF BARS SHALL BE STAGGERED. AT ANY CROSS SECTION
C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18
B7:300x500 B8:300x500 B9:300x500 B10:300x500 B11:300x500 B12:300x500 B13:300x500 B14:300x500 B15:300x500 B16:300x500 NOT MORE THAN 50% OF THE BARS SHALL BE LAPPED.
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) 13.LAPPING OF R/F BARS IN BEAMS & SLABS SHALL BE AVOIDED IN
THE FOLLOWING CASES.
a.) TOP BARS NEAR SUPPORT b.) BOTTOM BARS AT MIDSPAN
736(ANCHORAGE)

736(ANCHORAGE)
14.OVERLAP OF BARS IS NOT PERMITTED IN HANGERS.
15.STIRRUPS FOR CANTILEVER BEAMS TO HAVE HOOKS AT BOTTOM
T 1 U 1 V 1 W 1 X 1 Z 1 A1 16.ANY TYPE OF OPENINGS (CUTOUT/BLOCKOUT) SHALL BE MATCHED
WITH THE SERVICES DRAWINGS.
300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 300
17.COLUMN REBARS SHALL BE BENT AT CHANGE OF SECTION WITH
3-T16 SLOPE OF (1:6) AS AND WHERE REQUIRED.
3-T16

500
STP 2L-T8 AREA OF STATETMENT
3-T16
Total plot area 11853.0 SQ.M
736(ANCHORAGE)

736(ANCHORAGE)
3-T16 B17 TO B22
20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 (SCALE 1:25)
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C

C19
1
C20
1
C21
1
C22
1
C23
1
C24
1
C25 Total builtup area 11376.0 SQ.M
B17:300x500 B18:300x500 B19:300x500 B20:300x500 B21:300x500 B22:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
Bus stand building area 1450.0 SQ.M
736(ANCHORAGE)

736(ANCHORAGE)
A 1 B 1 2 3 D 1 E 1 F 1 G 1 H
Boundary wall length 453.0M
300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300
300 300 300 300 300 CLIENT'S SEAL & SIGN
925 925
3-T16 3-T12 3-T16 3-T16 3-T16 3-T12 3-T16 3-T16
STP 2L-T8 STP 2L-T8 STP 2L-T8

500

500

500

500

500
1 - T10 EF
STP 2L-T8 SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF STP 2L-T8
3-T16 3-T16 3-T16 3-T16 3-T16
736(ANCHORAGE)

736(ANCHORAGE)

3-T16
20-2L-T8 8-2L-T8 6-2L-T8 8-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 B23 (LOC: 0 TO 925) (LOC: 925 TO 2775) (LOC: 2775 TO 3700) B25 TO B28
@200 C/C @180 C/C @200 C/C @180 C/C @200 C/C @200 C/C @200 C/C @200 C/C (SCALE 1:25) SECTION 1-1 (B24) SECTION 2-2 (B24) SECTION 3-3 (B24) (SCALE 1:25)
1233 1233 (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
C26 1 C27 1 2 3 C28 1 C29 1 C30 1 C31 1 C32
B23:300x500 B24:300x500 B25:300x500 B26:300x500 B27:300x500 B28:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
APPROVAL AGENCY SEAL & SIGN
736(ANCHORAGE)

736(ANCHORAGE)
I 1 J 1 K 1 L 1 M 1 N 1 O 1 P 1 Q 1 R 1 S
300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300 3700 300
300

3-T16
3-T16

500
STP 2L-T8 all dimensions are in mm
3-T16
scale NTS dwg.no.:- 08
736(ANCHORAGE)

736(ANCHORAGE)
3-T16
B29 TO B38
20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8
(SCALE 1:25) date 31-01-21
@200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C @200 C/C

C33
1
C34
1
C35
1
C36
1
C37
1
C38
1
C39
1
C40
1
C41
1
C42
1
C43
dealt
B29:300x500 B30:300x500 B31:300x500 B32:300x500 B33:300x500 B34:300x500 B35:300x500 B36:300x500 B37:300x500 B38:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) appd. Ankesh
736(ANCHORAGE)

736(ANCHORAGE)

AATVIK CONSULTANCY
300
T 1 U
300
1

300
V 1 W
300
1 X
300
1 2 3

300
Z 1 A1
300
&
3700 3700 3700 3700 3700 3700 300 300 300 300 300
925 925
INFRASTRUCTURE LLP Foundation of Excellence
3-T16 3-T16 3-T12 3-T16 3-T16
3-T16 3-T12 3-T16 STP 2L-T8 STP 2L-T8 STP 2L-T8 Add-95 Rachna nagar bhopal (M.P)
500

500

500

500
500

1 - T10 EF STP 2L-T8 SFR 1-T10EF SFR 1-T10EF SFR 1-T10EF STP 2L-T8
3-T16 3-T16 3-T16 3-T16 3-T16
Email ID- aatvik.aatvik@gmail.com
736(ANCHORAGE)

736(ANCHORAGE)

3-T16
20-2L-T8 20-2L-T8 20-2L-T8 20-2L-T8 8-2L-T8 6-2L-T8 8-2L-T8 20-2L-T8 B39 TO B42 (LOC: 0 TO 925) (LOC: 925 TO 2775) (LOC: 2775 TO 3700) B44 Mob No-9425463303
(SCALE 1:25) SECTION 1-1 (B43) SECTION 2-2 (B43) SECTION 3-3 (B43) (SCALE 1:25) 1. DO NOT SCALE THE DRAWING AND NOT COUNT THE BARS
@200 C/C @200 C/C @200 C/C @200 C/C @180 C/C @200 C/C @180 C/C @200 C/C
1233 1233 (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) 2. ALL DIMENSIONS ARE IN MILI METER
3. S.B.C. OF SOIL = 150.0 KN/Sq.M
C44 1 C45 1 C46 1 C47 1 C48 1 2 3 C49 1 C50 4. DEPTH OF FOUNDATION - 2.5 METER
B39:300x500 B40:300x500 B41:300x500 B42:300x500 B43:300x500 B44:300x500
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) this drg.is property of architects and is not to
be used or reproduced without their prior
GROUND BEAM DETAIL-1 written permission.

You might also like