Internal Remotely Electric Tilt (iRET) : Operation Instruction
Internal Remotely Electric Tilt (iRET) : Operation Instruction
(iRET)
Operation instruction
Thank you for purchasing iRET modules. Please read this operation instruction
carefully before use, and keep it properly for future inspection.
Contents
1. Product introduction ........................................................................... 1
2. Installation Steps.................................................................................. 1
3. Engineering applications.....................................................................3
4. Portable electric antenna control operation instruction................. 3
4.1 Set up the test environment of PCU.........................................3
4.2 PCU operation instruction.......................................................... 4
5. Fault product replacement.................................................................. 6
Notes........................................................................................................... 7
6. Troubleshoot..........................................................................................8
1. Product introduction
Internal Remotely Electric Tilt (hereinafter referred to as iRET)
is designed based on AISG2.0 standard. It can adjust the signal
coverage of the antenna effectively and improve the quality of
communication services by controlling the antenna electric tilt
remotely. iRET module is designed as pluggable independent unit,
and easy to install and replace.
Components are shown as follow:
① ② ③ ④ ⑤
2. Installation Steps
Step 1: insert the iRET module into the antenna along the rail.
1
antenna
① ①screw
④ ②male connector
antenna
⑤
③ ③female connector
② ④female connector
①
⑤handing nut
Step 3: When connecting the control cable, match the guide slot of
the cable connector with the feather key of the male connector,
then tighten manually.
①the feather key of the male connector Tighten the joint and hold
②the guide slot of the female connector thread by hand, then rotate
① ② clockwise until tight.
2
3. Engineering applications
A flow diagram is shown below:
Turn on the switch Test whether the link Add all scanned devices
to energize the iRET, is normal, discern all to the base station
configure proper online equipments controller
threshold of power
consumption alarm
Set the tilt according Match the iRET track The iRET module has been
to the requirement with the antenna configured, if the config data
angle range is not matched, reload the
config file
3
4.2 PCU operation instruction
PCU AISG port Switch Power port AISG cable male connector
Connect the male connector of AISG cable with AISG port of PCU.
4
Scan devices
Calibrate
Get tilt
5
5. Fault product replacement
! The iRET module has completed the antenna-related
information configuration before leaving the factory (such as angle
range etc). Before replacing, please check whether the label
information of the new iRET module matches the antenna
information of the module to be replaced.
The steps of replacement are shown below:
Step 1: rotate the screw anti-clockwise to remove the screw. As
shown below:
Step 2: insert the new iRET module along the guide rails into the
antenna, tighten the screws clockwise, and re-connect the AISG
control cable. As shown below: Connect AISG cable
Insert Tighten
Note: If the UID of the new iRET module and the UID of the faulted
iRET module are not consistent, you can contact with customer
service (Tel: +86-0755-86186110) and provide the UID array
number (red dotted line as below) on the back of the original
antenna. Our company will arrange technical staff to change the
UID array number though the remote assistance or you can change
the UID array numbers by the tools that we provide. Antenna array
6
numbers are shown as the below picture:
! Notes
7
6. Troubleshooting
Y Y
Is the interface of
Is iRET motor rotating
control cable or iRET Y
intact? normally?
Set tilt successful? N 控制电缆或 iRET 接口是 电机是否运转正常?
是否成功设置下倾角?
否完好无损?
Y
N N
Y Does the power
Replace the control Replace iRET module
supply keep
normally during cable iRET module 更换模块
tilt setting? 更换控制电缆或模块
设置角度期间供
电是否正常?