Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

XTACIR/ZTACIR

D o u bl e Cu r r e n t Ca p a c i t y C o n du c t o r
Application
XTACIR & ZTACIR are new series of stranded conductors
made of super (or extra) thermo-resistance aluminum
alloy with Inver core.
To reduce sag, core replaces steel wires with invar wires
having lower coefficient of linear expansion, increased
current capacity is provided by use of ZTAL (super
thermo - resistance) and XTAL (extra thermo -
resistance) aluminum alloy stranded wires.

Construction Characteristics

ZTACIR XTACIR RS-XTACIR 1. Double current capacity available


2. The same sag as normal ACSR
3. No modification of existing towers required
Invar wire is a reinforcing alloy wire of steel and 36-38%
Nickel, and so named because its low coefficient of
linear expansion makes its length virtually invariable
with temperature.

12

11

ZTACIR 410mm 2
10
XTACIR & ZTACIR ACSR 410mm 2
9
Sag (m)

XTACIR 400mm 2
8
ACSR
7
TACSR SPAN LENGTH 300m
6

Double Current 5
0 50 100 150 200 250 300
Conductor temperature (℃)

Summary of properties
ACSR ZTACIR XTACIR RS-XTACIR
Type of wire 410mm2 410mm2 400mm2 400mm2
Diameter (mm) 28.5 28.5 26.6 28.0
Weight (kg/m) 1.673 1.687 1.776 1.792
Tensile
(kN) 136.1 124.6 139.8 138.1
Strength
Permissible
(A) 855 (90˚C) 1711 (210˚C) 1755 (230˚C) 1816 (230˚C)
Current
Size (mm2) 120~1520 120~1520 90~810 110~570
APPENDIX-1 SUPER THERMO-RESISTANCE ALUMINUM ALLOY CONDUCTORS GALVANIZED INVAR REINFORCED (ZTACIR)

No. SIZE(mm2)
ITEM 120 160 200 240 330 410 610 810 1,520
1 SIZE mm2 120 160 200 240 330 410 610 810 1,520
2 STRUCTURE ZTAL NO./mm 30/2.3 30/2.6 30/2.9 30/3.2 30/4.0 30/4.5 54/3.8 45/4.8 84/4.8
INVAR NO./mm 7/2.3 7/2.6 7/2.9 7/3.2 7/3.1 7/3.5 7/3.8 7/3.2 7/4.8
3 CROSS- ZTAL mm2 124.7 159.3 198.2 241.3 326.8 413.4 612.4 814.5 1,520
SECTIONAL INVAR mm2 29.09 37.16 46.24 56.29 52.84 67.35 79.38 56.29 126.7
AREA TOTAL mm2 153.8 196.5 244.4 297.6 379.6 480.8 691.8 870.8 1647
4 OUTER DIAMETER mm2 16.1 18.2 20.3 22.4 25.3 28.5 34.2 38.4 52.8
5 MIN. TENSILE LOAD kN 48.0 60.3 74.4 89.9 98.1 124.6 166.5 171.3 335.0
{kgf} {4,890} {6,150} {7,600} {9,170} {10,000} {12,710} {16,980} {17,470} {34,160}
6 MASS ZTAL kg/km 345.7 441.5 549.3 668.9 905.4 1,145 1,698 2,259 4,228
INVAR kg/km 233.8 298.8 371.7 452.6 424.8 541.5 638.2 452.6 1,019
TOTAL kg/km 579.5 740.3 921.0 1122 1330 1686 2336 2712 5247
7 ELECTRICAL RESISTANCE Ω/km 0.237 0.185 0.149 0.122 0.0904 0.0714 0.0481 0.0363 0.0195
8 CURRENT CONST. A 768 907 1,050 1,202 1,457 1,711 2,173 2,598 4,000
CAPACITY SHORT A 836 988 1,145 1,311 1,592 1,872 2,382 2,853 4,419
9 MODULUS BELOW GPa 80.7 80.7 80.7 80.7 75.7 75.8 73.3 68.3 69.5
OF TPT {kgf/mm2} {8,230} {8,230} {8,230} {8,230} {7,720} {7,730} {7,470} {6,960} {7,090}
ELASTICITY UPPER GPa 161.8 161.8 161.8 161.8 161.8 161.8 161.8 161.8 161.8
TPT {kgf/mm2} {16,500} {16,500} {16,500} {16,500} {16,500} {16,500} {16,500} {16,500} {16,500}
10 LINEAR BELOW TPT /℃ 15.3x10-6 15.3x10-6 15.3x10-6 15.3x10-6 17.0x10-6 17.0x10-6 17.9x10-6 19.9x10-6 19.4x10-6
EXPANSION UPPER TPT /℃ 3.6x10-6 3.6x10-6 3.6x10-6 3.6x10-6 3.6x10-6 3.6x10-6 3.6x10-6 3.6x10-6 3.6x10-6
11 DIMENSION 〇:ZTAL
●:GALVANIZED INVAR

TPT : Transition Point Temperature

APPENDIX-2 EXTRA THERMO-RESISTANCE ALUMINUM ALLOY CONDUCTORS ALUMINUM CLAD INVAR REINFORCED (XTACIR)

No. SIZE(mm2)
ITEM S-ACSR100 120 160 200 240 330 410 610 810
1 SIZE mm2 90 120 160 200 240 330 400 600 780
2 STRUCTURE XTAL NO./mm 9/SB(3.60) 12/SB(3.50)14/SB(2.85)14/SB(3.15)14/SB(3.45)14/SB(4.05) 14/SB(4.50) 16/SB(5.10)16/SB(5.90)
XTAL NO./mm - - 10/SB(2.85)10/SB(3.15)10/SB(3.45)10/SB(4.05) 10/SB(4.50) 12/SB(5.10)12/SB(5.90)
INVAR NO./mm 7/3.0 7/3.0 7/3.0 7/3.4 7/3.8 7/3.8 7/4.3 7/5.0 7/5.0
3 CROSS- XTAL mm2 91.62 115.5 153.1 187.0 224.4 309.1 361.6 572.0 765.5
SECTIONAL INVAR mm2 49.48 49.48 49.48 63.55 79.38 79.38 101.6 137.5 137.5
AREA TOTAL mm2 141.1 165.0 202.6 250.6 303.8 388.5 483.2 709.5 903.0
4 OUTER DIAMETER mm 14.5 15.6 17.3 19.2 21.2 23.8 26.6 32.2 36.2
5 MIN. TENSILE LOAD kN 59.2 62.7 68.6 83.4 102.8 114.3 139.8 197.1 222.1
{kgf} {6,040} {6,390} {7,000} {8,500} {10,480} {11,660} {14,260} {20,100} {22,650}
6 MASS XTAL kg/km 252.4 318.0 421.5 515.1 617.9 851.4 1051 1575 2108
INVAR kg/km 353.1 353.1 353.1 453.5 566.4 566.4 725.3 980.7 980.7
TOTAL kg/km 605.5 671.1 774.6 968.6 1184 1418 1776 2556 3089
7 ELECTRICAL RESISTANCE Ω/km 0.293 0.238 0.184 0.150 0.124 0.0924 0.0747 0.0503 0.0380
8 CURRENT CONST. A 605 675 958 1,101 1,255 1,515 1,755 2,292 2,748
CAPACITY SHORT A 700 782 1,112 1,280 1,462 1,769 2,053 2,691 3,235
9 MODULUS BELOW GPa 93.4 88.8 83.8 84.7 85.4 80.2 80.8 79.3 75.5
OF TPT {kgf/mm2} {9,520} {9,060} {8,550} {8,640} {8,710} {8,180} {8,240} {8,090} {7,700}
ELASTICITY UPPER GPa 152.0 152.0 152.0 152.0 152.0 152.0 152.0 152.0 152.0
TPT {kgf/mm2} {15,500} {15,500} {15,500} {15,500} {15,500} {15,500} {15,500} {15,500} {15,500}
230˚C GPa 152.0 152.0 152.0 152.0 152.0 152.0 152.0 152.0 152.0
{kgf/mm2} {15,500} {15,500} {15,500} {15,500} {15,500} {15,500} {15,500} {15,500} {15,500}
10 LINEAR BELOW TPT /℃ 12.0x10-6 13.1x10-6 14.5x10-6 14.2x10-6 14.0x10-6 15.5x10-6 15.4x10-6 15.8x10-6 17.1x10-6
EXPANSION UPPER TPT /℃ 3.7x10-6 3.7x10-6 3.7x10-6 3.7x10-6 3.7x10-6 3.7x10-6 3.7x10-6 3.7x10-6 3.7x10-6
230˚C /℃ 10.8x10-6 10.8x10-6 10.8x10-6 10.8x10-6 10.8x10-6 10.8x10-6 10.8x10-6 10.8x10-6 10.8x10-6
11 DIMENSION □:XTAL
●:INVAR

TPT : Transition Point Temperature

TEL: +81-3-5783-1907
FAX: +81-3-5783-1885
http://www.viscas.com/index_e.html