KOREAN REGISTER OF SHIPPING

Record of Cargo Ship Safety Equipment


This form must be kept on board and be available for inspection by a nominated surveyor or recognized
organization at all times.

1. Ship's Particulars

Report No. : ATN-S0080-19 Survey Date : 13 July 2019


Ship's Name : GAS BEAUTY I Class No. : 8200001
Type of Ship : GAS CARRIER

The total number of persons for which life saving appliances are provided : 35 persons

1 lifeboats on port side capable of accommodating 44 persons

1 lifeboats on starboard side capable of accommodating 44 persons

2 motor lifeboats (inclusive of the total lifeboats shown above)

mechanically propelled lifeboats (inclusive of the total lifeboats shown above)

1 rescue boats(included / excluded in the total lifeboats shown above)

liferafts for which approved launching devices are required capable of


accommodating persons exclusive of any liferaft stowed forward
4 liferafts for which approved launching devices are not required capable of
accommodating 80 persons exclusive of any liferaft stowed forward
1 liferaft stowed forward or aft, in accordance with SOLAS Reg.III/31.1.4 capable of
accommodating 6 persons

14 lifebuoys

42 lifejackets and ea for children

42 immersion suits / anti-exposure

thermal protective aids

2. DOCUMENTS FOR GENERAL REQUIREMENTS, ETC.

2.1 Fire control plans


Date : 27 March 2013 Approved by : KR

2.2 The ship has (a) space(s) of vehicles with fuel other than ro-ro spaces -

SER 1 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

3. SAFETY OF NAVIGATION

3.1 Shipborne Navigational Equipment

3.1.1 Magnetic compass

Name Location Type Q'ty Manufacturer Approved by

Standard Compass Compass Deck 1 EC

Steering Compass

Spare Compass

3.1.2 Gyro compass


Name Type Q'ty Manufacturer Approved by

Master gyro compass STD-4/0801 1 ANSCHUTX+CO EC

Gyro compass bearing repeater 133.402/2112 5 ANSCHUTX+CO EC

3.1.3 Means of communication for relaying heading information to emergency positions

Name Type Q'ty Manufacturer Approved by

Gyro compass heading repeater

Magnetic compass

Telephone to emer. steering position 1

3.1.4 Heading / Track control system


Name Type Q'ty Manufacturer Approved by

ANSCHUTZ+CO 1 EC

3.1.5 Pelorus or compass bearing device


Name Type Q'ty Manufacturer Approved by

ANSCHUTZ+CO 1 EC

3.1.6 Properly adjusted transmitting heading device(THD)*


Name Type Q'ty Manufacturer Approved by

* Note: Applies to ships of 300 gt and upwards but less than 500 gt.

3.1.7 Nautical charts and publication


- Hard Copy
Nautical Chart

Nautical Pubilcatons *

* Publications mean Sailing Directions, Notice to Mariners, Tide Tables, Nautical Almanac, Light Lists & Radio Signals, IAMSAR Manual Vol.III,
International Code of Signals, etc.

SER 2 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

- Electronic Publications
Name Type Q'ty Manufacturer Approved by

ECDIS FMD-3100 1 FURUNO ELECTRIC DNV

Back-up arrangement for ECDIS FMD-3100 1 FURUNO ELECTRIC DNV

Electronic nautical publications 1

Backup arrang't for elec. nautical publications

3.1.8 Receiver for a global navigation satellite system or terrestrial radio-navigation system
Name Type Q'ty Manufacturer Approved by

GPS MX400 1 LEICA EC

GPS MX200 1 MAGNAVOX EC

3.1.9 Radar installation


Type Q'ty Frequency band Manufacturer Approved by

45X-P 1 X DECCA BRIDGE MASTER EC

60S-P 1 S DECCA BRIDGE MASTER EC

3.1.10 Installation of Automatic Radar Plotting Aid (ARPA)


Type Q'ty Manufacturer Approved by

45X-P 1 DECCA BRIDGE MASTER EC

60S-P 1 DECCA BRIDGE MASTER EC

3.1.11 Automatic tracking aid (ATA)


Name Type Q'ty Manufacturer Approved by

Automatic tracking aid

Second automatic tracking aid

3.1.12 Electronic plotting aid(EPA)

Name Type Q'ty Manufacturer Approved by

3.1.13 Speed and distance measuring device

Kind Type Q'ty Manufacturer Approved by

To indicate speed and distance through the water 1 EC

To indicate speed and distance over the ground

SER 3 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

3.1.14 Other Navigational Equipment


Name Type Q'ty Manufacturer Approved by
Automatic Identification system SAAB R4 1 EC
Voyage data recorder 100-G3/5 1 RUTTER EC
Echo-sounding device SIMRAD 1 NMD
Rate of turn indicator
Sound reception system
Radar reflector*
Daylight signalling lamp 1 EC
LRIT system DMR800LRIT 1 SKYWAVE EC
BNWAS NT990 1 NAVITRON EC
* Applicable to ships of less than 150 gross tonnage.

3.1.15 Rudder, propeller, thrust, pitch and operational mode indicator


Name Type Q'ty Manufacturer Approved by
Rudder angle indicator 1
Propeller revolution rate indicator 1
Thruster operation modeindicator
Pitch condition indicator

3.2 Signaling Apparatus


Apparatus Q'ty Location Approved by
Daylight signalling lamp 1 W/H
Forecastle bell 1 Forecastle
Gong 1 W/H
Ship's whistle 2 Compass Deck and Fore Mast
3 Black bell shapes 3 W/H
1 Black diamond shape 1 W/H

4 COMMUNICATIONS
4.1 Search and rescue locating devices (SART, AIS-SART)
Location Q'ty. Type Manufacturer Approved by
W/H 2 TRON SART JOTRON EC

4.2 Two-way VHF radiotelephone apparatus


Location Q'ty. Type Manufacturer Approved by
W/H 3 TRON VHF JOTRON EC

SER 4 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

5. LIFE-SAVING APPLIANCES
5.1 Rockets and Signals
Kind Q'ty. Location Manufacturer Approved by
Line throwing appliance with 4 rockets and lines 1 W/H PAINS WESSEX EC
12 rocket parachute flares 1 W/H PAINS WESSEX EC

5.2 Location of Lifeboats, Liferafts and Rescue boat


Combined with Location
No *1 Type of LSA*2 Launching mode rescue boat(Y/N) Q'ty. Longitudinal Athwartship Deck
1 EBFP Davit-launching Y 1 Stern S Upper Deck
2 EBFP Davit-launching N 1 Stern P Upper Deck
LRI Throwing 1 Stern S Upper Deck
LRI Throwing 1 Stern P Upper Deck
LRI Throwing 1 Stern S Upper Deck
LRI Throwing 1 Stern P Upper Deck
LRI Throwing 1 Stern C Upper Deck

Note : No. *1 Lifeboats only to be numbered from forward , odd numbers starboard, even numbers port.
Type of LSA *2 OB : Lifeboat(Open type without engine) OBE : Lifeboat(Open type with engine) EB : Lifeboat(enclosed type)
EBAS : Lifeboat(enclosed, self-contained air support) EBFP : Lifeboat(Enclosed, fire-protected) RB : Rescue boat
FRB : Fast rescue boat LRR : Liferaft(rigid type) LRI : Liferaft(Inflatable type)

5.2.1 Lifeboats
Carrying
capacity Dimension Manufactured
No.*1 Type (No. of Material *2 date Manufacturer Approved by
(L*B*D)
persons) (yyyy.mm.dd)
1 Totally Enclosed 44 FRP 8.00x3.00x1.19 HARDING NMD
2 Totally Enclosed 44 FRP 8.00x3.00x1.19 HARDING NMD

Note: *1. Lifeboats numbered from forward, odd numbers starboard, even numbers port.
*2. Material FRP : Fiberglass Reinforced Plastcs, STL : Steel, AAL : Aluminium Alloy, WD : Wood, OTR : Other Material

SER 5 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

5.2.2 Inflatable Liferafts


Carrying capacity Manufactured
Type Q'ty (per each) Date Manufacturer Approved by

KHA-20-TOB 4 20 2010-01-01 SEA-SAFE EC


KHA-20-TOB 1 6 2010-03-01 SEA-SAFE EC

5.2.3 Rigid Liferaft


Carrying capacity Manufactured
Type Q'ty (per each) date Manufacturer Approved by

5.2.4 Rescue Boat / Fast Rescue Boat


Carrying capacity Manufactured
Kind* Type Q'ty (per each) date Manufacturer Approved by
RB Refer to NO.1 L/B 1 44 1980-08-08 HARDING NMD

Note : * Kind RB : Rescue Boat FB : Fast Rescue Boat

5.3 Launching and Embarkation Arrangements


5.3.1 Embarkation arrangements
Location Length or
Name Q‘ty Manufacturer Approved by
Type Capacity each
Upper Deck(Aft/Fwd)
3 (m)
Jacob's Ladder
Embarkation ladder
(m)

(m)
Marine Evacuation
System
(m)

5.3.2 Type of warning system for abandoning ship :


Name Location Type Q‘ty Manufacturer Approved by
General Alarm W/H 1

Whistle W/H 1

Public address system Embarkation Station 1

SER 6 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

5.3.3 Davits and winches for Lifeboats, liferafts & rescue boat
Davit Winch Fall
Kind of Manufacturer Manufacturer Length(M)
LSA* S.W.L S.W.L Rope
wire
or Breaking
Load(MT)
Type Type size(¢)

EBFP 4,282 7,341 Wire 40.00


Hinged Gravity Type Electric Motor 26.0

EBFP 4,282 7,341 Wire 40.00


Hinged Gravity Type Electric Motor 26.0

Note : * Type of LSA OB : Lifeboat(Open type without engine) enclosed type) OBE : Lifeboat(Open type with engine) EB : Lifeboat(enclosed type)
EBAS : Lifeboat(enclosed, self-contained air support) EBFP : Lifeboat(Enclosed, fire-protected) RB : Rescue boat
FRB : Fast rescue boat LRR : Liferaft(rigid type) LRI : Liferaft(Inflatable type)

5.4 Mechanical pilot hoist


Manufacturer Source of power No. of falls Approved by

5.5 Other Life-saving Appliances


Name Q'ty. Manufacturer Approved by
Lifejackets with whistle and light attched 42 TRIUMF EC
Additional lifejackets for children - -
Immersion suits or anti-exposure suit(Immersion Suit
only) 42 SCANDIA EC
Immersion suits or anti-exposure suit(Combined with
Lifejacket)
Thermal protective aids
Lifebuoys with self-igniting lights and smoke signals 2 MCMURDO EC
and capable of quick release from bridge
Lifebuoys with self-igniting light only 6 MCMURDO EC
Lifebuoys with buoyant lifeline 6 MCMURDO EC
Lifebuoys without attachments 2 MCMURDO EC
Lifebuoy with a self-igniting light and a buoyant lifeline
in accordance with MSC.1/Circ.1331

SER 7 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

6 FIRE EXTINGUISHING ARRANGEMENTS IN MACHINERY SPACES


6.1 Fire Pumps, Hydrants & Hoses
6.1.1 Main fire pumps

No. Location Type of prime mover Capacity(㎥/h) Head(m)

No.1 ENGINE ROOM ELECTRIC MOTOR 150.00

No.2 ENGINE ROOM ELECTRIC MOTOR 150.00

No.3

6.1.2 Emergency fire pump


Location Suction head(m) Type of prime mover Capacity (㎥/h) Head(m)
Emergency Fire Pump Electric Motor 80.00

6.1.3. Hydrants & Hoses


Engine Room Boiler Room Shaft Tunnel
Kind Type of Coupling
No Dia(mm) Length(m) No Dia(mm) Length(m) No Dia(mm) Length(m)
19 ¢ 50 - - - Norlas
Hydrants
- - -
19 ¢ 50 15 - - Dual Type
Hoses
- - -

6.2 Fire Extinguishers


Kind Location Q'ty Capacity Type Approved by
Boilers 1 25kg Powder NMD
Oil fuel units
16 12kg Powder NMD
Portable Internal combustion machinery1
extinguishers
2 6kg CO2 NMD
Steam tubines(Total output≥375kW)
Others
Boilers(min.20ℓ)
Portable air
foam equipment Internal combustion machinery(min.20ℓ)
Steam tubines(min.45ℓ)(Total output≥375kW)
Boilers(min.135ℓ) 1 50kg Powder NWD
Non-Portable Internal combustion machinery(min.45ℓ) 1 50kg Powder NWD
extiguishers Steam tubines(min.45ℓ)(Total output≥375kW)
Others

6.3 Fixed Fire-extinguishing Systems in Machinery space

6.3.1 Type of Machinery Space:


□ Containing oil fired boilers and oil fuel unit X
□ Containing oil fired boilers only -

□ Containing engine and boiler room -

□ Containing steam turbines or enclosed steam engines -

SER 8 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

6.3.2 Fixed fire-extinguishing systems

6.3.2.1 Fixed CO2 gas system

Total CO2 No. of Capacity Location


capacity required(kg) containers (per each)(kg) Container storage room Control valve
7,290.00 162 45.00 Upper Deck(Stbd) Upper Deck(Stbd)

Type of audible warning Approved by


Siren DNV

6.3.2.2 Halogenated hydrocarbon System


- 1 Total flooding system

Gross Volume Net Volume Quantity required No. of Quantity


Kind of Halon Approved by
of the space(㎥) of the space(㎥) Min.% Max.% containers each (kg)

Location of container storage room Releasing mechanism and its location Type of warning

In a case where Halon 1301 is stored within a protected machinery space


Sources of power for releasing Materials for electric power circuits or pneumatic or
Releasing mechanism and its location
mechanism and their locations hydraulic power circuits connecting the containers

- 2 Local operated halon system


For local automatically operated fixed fire-extinguishing units containing Halon 1301 or 1211, fitted in enclosed areas of
high fire risk within machinery spaces, in addition to, and independent of, any required fixed fire extinguishing system.
Quantity
Volume of the
Kind of Halon Spaces protected space(㎥) Max. Quantity No. of Quantity
required(kg) containers each(kg)

Type of audible warning Approved by

- 3 Local operated Halon units for machinery side


For local automatically operated fixed fire-extinguishing units containing Halon 1301 or 1211, fitted in enclosed areas of
high fire risk within machinery spaces, in addition to, and independent of, any required fixed fire extinguishing system.
Quantity
Volume of the
Kind of Halon Spaces protected space(㎥) Max. Quantity No. of Quantity
required(kg) containers each(kg)

Type of audible warning Approved by

SER 9 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

6.3.2.3 High Expansion Foam System


Volume of the largest Quantity of Supply rate Expansion ratio
space to be protected(㎥) foam-forming liquid(ℓ)

Kind Number Location


Foam producing unit
Foam generator
Source of power supply for foam generator
Foam-forming liquid
Control system

6.3.2.4 Pressure Water Spraying System


Name Pressure kept at Average distribution rate
Pressure water spraying system 0 0

Name Number Positioning Type Approved by


Spraying nozzles

Name Location Capacity (㎥/h)


Pump supplying water
Controling of pumps
Distribution valves

Name Type Capacity


Prime mover for pump

6.3.2.5 Low Expansion Foam system


Protected spaces Quantity(ℓ or ㎥) Expansion Ratio Manufacturer
0

6.3.2.6 Fixed steam system for fire-extinguishing


Type Fire Detector Type
Approved by
Quantity Manufacturer

6.3.2.7 Fixed other gas system for fire-Extinguishing


Type Fire Detector Type
Approved by
Quantity Manufacturer

SER 10 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

6.3.3 Fixed Local Application Fire-Extinguishing Systems

Type Fire Detector Type


Approved by
Quantity Manufacturer

6.4 Special Arrangements in Machinery Spaces of Category A

6.4.1 Means for stopping machinery and shutting off oil fuel suction pipes
Type Means and Location
Vent fans REMOTE SHUT DOWN/BRIDGE
Induced draught fans REMOTE SHUT DOWN/BRIDGE
Forced draught fans REMOTE SHUT DOWN/BRIDGE
Oil fuel transter pumps REMOTE SHUT DOWN/SAFETY ROOM
Oil fuel units REMOTE SHUT DOWN/SAFETY ROOM
Oil fuel tank valves REMOTE SHUT DOWN/SAFETY ROOM

6.4.2 Fire detection and alarm system in Machinery Spaces

6.4.2.1 Control systems

Kind Location Source of power Manufacturer Approved by


Main & Em'cy
Control Panel W/H, CCR Power AC & DC DNV
Main & Em'cy
Indicatiog unit W/H, CCR Power AC & DC DNV

6.4.2.2 Arrangement

Number of detectors or manual call points


Loop No. spaces to be covered
Smoke Heat Flame(Etc.) Manual call points
30 8 2 9 ENGINE ROOM

6.4.2.3 Detectors

Max. floor area Max. distance apart Max. distance away


Detectors Type Type/Model per detector between centers from bulkheads Approved by
(Act./Requi.) (Act./Requi.) (Act./Requi.)

Smoke 74.0 / 74 11.0 / 11 5.5 / 5.5 EC


Heat 37.0 / 37 9.0 / 9 4.5 / 4.5 EC
Etc(ex. flame)

SER 11 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

7 FIRE EXTINGUISHING APPLIANCES IN ACCOMMODATION AND SERVICE SPACES

7.1 METHOD of Protection for Accommodation and/or Service spaces ....... I C / II C / IIIC

- Smoke detection system for protection of all corridors, stairways and escape routes within accommodation
spaces (Method IC)

- Automatic sprinkler system for protection of accommodation spaces, galleys and other service spaces
except no substantial fire risk spaces. In addition, Smoke detection system for protection of all corridors,
stairways and escape routes within accommodation spaces (Method IIC)

X Smoke detection system for protection of all accommodation spaces and service spaces except no
substantial fire risk spaces. (Method IIIC)

7.2 Fire detection systems

7.2.1 Control systems

Kind Location Source of power Manufacturer Approved by

W/H, SAFETY ROOM Main & Em'cy AC & DC DNV


Control Panel Power
W/H, SAFETY ROOM Main & Em'cy AC & DC DNV
Indicatiog unit Power

7.2.2 Arrangement
Number of detectors or manual call points
Loop No. spaces to be covered
Smoke Heat Flame(Etc.) Manual call points

24 147 10 22 All areas except E/R

7.2.3 Detectors

Max. floor area Max. distance apart Max. distance away


Detectors Type Type/Model per detector between centers from bulkheads Approved by
(Act./Requi.) (Act./Requi.) (Act./Requi.)
Smoke 74.0 / 74 11.0 / 11 5.5 / 5.5 DNV

Heat 37.0 / 37 9.0 / 9 4.5 / 4.5 DNV

Etc(ex.flame)

SER 12 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

7.3 Automatic Sprinkler System


In the case of Methode IIC, the followings should be filled in addition to paragraph 7.2.

7.3.1 Automatic sprinkler system & Fire detector/alarm system

Type Approved by Temp. at which the system Source of power Line press.
comes into operation(°C) Kept (㎏/㎠)

Main & Em'cy

Section No. No. of sprinklers per each section Location of


indicating unit

7.3.2 Pressure tank


Means of replenishing the air under pressure
Location Volume(ℓ) and of the fresh water charge in the tank

Air press in the tank Working press. of the


(bar or kg/㎠) Distance from the bottom of the tank to the highest sprinkler (m)
sprinkler

7.3.3 Sprinkler pump


Capacity pressure which the pump Source of
Location
(㎥/hr) is brought into action(kg/㎠) power
Main

7.4 Portable fire extinguishers in accommodation and service spaces


Location No. Capacity Type Approved by

ACC. /SERVICE/CARGO SPACES 5 18kg CO2 NMD

ACC. /SERVICE/CARGO SPACES 23 12kg Powder NMD

ACC. /SERVICE/CARGO SPACES 8 10kg F.W. NMD

SER 13 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

8 FIXED FIRE EXTINGUISHING APPLIANCES IN CARGO SPACES AND CARGO TANK


AND CARGO PUMP ROOM PROTECTION
8.1 Fire Extinguishing Arrangements for protection of
Dry cargo spaces / Cargo pump room on tankers / Ro-Ro spaces

8.1.1 CO2 System


Location of container storage room
Total CO2 capacity No. of Capacity each
required containers (kg) Approved by
Location of control valve
(kg) (kg)
(ℓ) (ℓ)

An approved automatic fire detection and fire alarm system


Type Approved by

8.1.2 Halogenated Hydrocarbon System


Gross Volume of the Net Volume Capacity required No. of Capacity
Kind of Halon space(㎥) of the space(㎥) containers each(kg) Approved by
Min.(%) Max.(%)

Location of container storage room Releasing mechanism and its location Type of warning

8.1.3 High Expansion Foam


Volume of the largest Quantity of foam
space to be protected(㎥) forming liquid (ℓ) Supply rate Expansion ratio

Kind Number Location


Foam producing unit
Foam generator
Source of power supply for foam generator
Foam-forming liquid
Foam-forming liquid

8.1.4 Pressure Water Spraying System


Name Pressure kept at (kg/㎡) Average distribution rate (ℓ / min)
Pressure water spraying system

Name Number Positioning Type Approved by


Spraying nozzle

SER 14 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

8.1.5 Portable fire extinguishers

Location No. Capacity Type Approved by

8.1.6 Fire extinguishing appliances


N.B Applicable only for RO/RO cargo spaces, but not for cargo spaces other than RO/RO spaces, intended
for the carriage of motor vehicles with fuel in their tanks for their own propulsion.

Name Location Q'ty Capacity Type Approved by


Water fog
applicator
Potable foam
applicator

8.2 Cargo Tank Protection on tankers

8.2.1 Inert Gas System


Total capacity of blower
Type of system Approved by Instruction manual provided (㎥/hr)

Moss inert gas plant DNV Y 6,000

8.2.2 Fixed foam system for tanks internally


Quantity(ℓ) Type Manufacturer
Foam characteristics

Ratio of concentration Supply rate(ℓ/min) Expansion ratio(times)


Foam solution

Name or Type Approved by


Pump serving system

8.2.3 Fixed deck foam system / Dry chemical system


Quantity(ℓ) Type Manufacturer
Foam characteristics

Foam solution Ratio of concentration Supply rate(ℓ/min) Expansion ratio(times)

Number Type
Monitors
Means of
supply No. of Hydrants No. of Hoses No. of Nozzles
Applicators

Name or Type Approved by


Pump serving system

SER 15 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19
8.2.4 Portable fire extinguishers in cargo areas
Location No. Capacity Type Approved by
UPPER DECK 5 18kg CO2 NMD

9 OTHER FIRE EXTINGUISHING APPLIANCES


9.1 Fire extinguisher for paint lockers and flammable liquid lockers
Kind of fire extinguisher / Floor area
Extinguishing system for locker (㎡) Manufacturer Type Approved by

SPRINKLER SYSTEM 16.0 DNV

9.2 Fire-fighter's outfit


9.2.1 Personal equipment (Protective clothing, Boots, Gloves, Helmet, Axe)
Sets Manufacturer Type Location Approved by
1 FORE NMD
2 TANKDOME NMD
2 ACC. NMD

9.2.2 Self-contained breathing apparatus

No. Manufacturer Air capacity per each cylinder(ℓ) Spare cylinders Approved by

4 DRAGER 1400 8 NMD

9.2.3 Smoke helmet or smoke mask with air pump and hose
No. Manufacturer Air capacity (ℓ) Approved by

9.2.4 Safety Lamp


No. Manufacturer Type Approved by
10 NMD

9.3 Hydrants, Hoses, Nozzles, Fire extinguishers and shore connection


Diameter of
Kind Location Number Diameter(mm) Length (m) thefiremain (mm)
ON DECK 39 50
Hydrants
INACCOMMODATION 8 50
ON DECK 39 50 15 152
Hoses with
IN ACCOMMODATION 8 50 15
nozzle for each

Coupling Type Insert


International 5
shore connection Nozzles Type Dual Type

SER 16 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

9.4 Fire extinguishing system/extinguishers for Galley

Kind of fire extinguisher Manufacturer Type Capacity Approved by

CO2 12kg NMD

9.5 Emergency Escape Breathing Devices(EEBD)


Functioning
Sets Manufacturer Type Approved by
period (min.)
11 15 nmd

Location

10 ADDITIONAL SAFETY EQUIPMENT FOR (OIL/CHEMICAL/GAS) TANKERS

10.1 Protective equipment


Components No Manufacturer Type Approved by
Large aprons 4

Glover with long sleeves 4

Footwear 4

Chemical-resistant coveralls 4

Goggles or Face shields 4

10.2 Safety Equipment


10.2.1 Personal equipment
Components No Manufacturer Type Approved by
Protective clothing 4

Boot & Gloves 4

Tight-fitting goggles 4

Fireproof lifeline with belt 4

Explosion-proof lamp 4

10.2.2 Self-contained breathing apparatus (SCBA)

Air capacity per


Components No. Manufacturer type Approved by
each cylinder (ℓ)

SCBA 6 1,400 NMD

Spare cylinder

Air compressor

Charging manifold

Lowpressureairlinesystem

SER 17 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

10.3 Portable measuring equipment


Kind No Manufacturer Type Approved by

10.4 Emergency escape respiratory protection


No. Capacity(min) Manufacturer Type Approved by

37 15 NMD

10.5 Medical first aid equipment


Kind No Manufacturer Type Approved by

Medical first aid equipment 01

Oxygen resuscitation 01
equipment

Antidotes 01

Stretchers 02

11 EQUIPMENT RENEWED, ALTERATIONS AND/OR ADDITIONS EFFECTED


SINCE THE RECORDED WAS PREPARED

No. Description Remark

1 4 sets of Two-Way Radio Telephone for Fire Fighter Team

2 1) Maker : Motorola

3 2) Type : GP-340

4 3) Intrinsically Safe Div 2, Groups C&D Class: II T4

SER 18 /19 (2013.01)


Rev. [0]
Class No. : 8200001 Report No.: ATN-S0080-19

12 PARTICULARS OF ANY SPECIAL FEATURES OR ADDITIONAL INFORMATION

Verified by : Surveyor :
Mohamed Ramadan

SER 19 /19 (2013.01)

You might also like