Professional Documents
Culture Documents
Over-Head Level Indicators: O O O O O O O O
Over-Head Level Indicators: O O O O O O O O
Over-Head Level Indicators: O O O O O O O O
•
Over-Head monitoring
Level Indicators •
analysing
NBK-04
N2
ASME B16.5 flange 2"; 2½"
OOMaterial:
stainless steel 1.4571
OO Insensitive magnet roller display or
ball display without auxiliary energy
OO Limit contacts
Analogue output, HART®,
OO
Profibus-PA®,
FoundationTM Fieldbus®
www.kobold.com
1
Over-Head Level Indicators Model NBK-04
Description
Kobold over-head level indicators are used for continuous Flange nominal size: DIN EN 1092-1 DN 50 or
measurement, display and monitoring of liquid levels. The 65, PN 16
float inside the tank is attached by means of a connecting rod ASME B16.5 2" 2" or
to the magnet carrier in the over-head tube. The magnet fitted 2 ½", CL150 lbs
in the magnet carrier operates, in a non-contacting manner, Max. operating pressure: PN 16
the display and monitoring devices fitted outside tube. Operating temperature: -50 °C ... +120 °C
The following indication and monitoring devices are available: Viscosity: max. 200 mm2/s
Measuring length: min. 600 mm
Magnetic roller indicator max. 4000 mm
As the float passes by, the red/white rollers are rotated in Total length: see dimension drawing
succession by 180° around their own axes. The rollers
Min. density: 0,43 kg/dm3
change from white to red as the level rises and from red to
white as the level falls. The advantage of ball display is the ATEX approval: see separate description
higher protection category, good visibility of 180° and higher
vibration resistance with filled version. The level in a tank or a Roller display RP (max. length 4 000 mm)
mixer is continuously displayed as a red column, even when Material roller: Polypropylene
the power fails. Display glass: Plexiglas®
Carrier frame material: Aluminium, brown anodised
Transmitter Operat. temperature: 0 ... 120 °C
To remotely transmit the level a transmitter with a chain of Protection: IP 54
resistors or a magnetostrictive transducer can be mounted
outside the bypass tube. A continuous standard signal of Ball display model KP (max. L = 3 800 mm one-piece)*
4 ... 20 mA is generated by means of a fitted transmitter. Material ball: Ultramid®
This standard signal can then be displayed on analogue or Sight tube: Plexiglas®
digital indicating devices. Optionally, HART®, Profibus-PA® Sealing plug: Aluminium
or FoundationTM Fieldbus® communication protocols are Seal: NBR
possible. Ball support rail: Aluminium, brown anodised
Carrier frame: Stainless steel 1.4301
Universal indicating unit Scale: Hard-PVC,
stainless steel 1.4301 (Option MV)
A universal indicating unit of type series ADI can be mounted
Operat. temperature: - 20 ... + 80 °C
on the bypass to display and evaluate the standard signal
Protection: IP 66
(4 ... 20 mA) generated by the transmitter.
Ball display model KM (max. L = 3 800 mm one-piece)*
Limit contacts
Material ball: Ultramid® B
One or more reed contacts for limit-value acquisition or also Sight tube: Makrolon®
for level control can be secured to the bypass tube. Sealing plug: Aluminium
Seal: FKM
Applications Ball support rail: Aluminium, brown anodised
OO Storage tanks Carrier frame: Stainless steel 1.4301
OO Aggressive media
Scale: Hard-PVC,
stainless steel 1.4301 (Option MV)
OO Mixing vessels
Operat. temperature: - 50 ... +120 °C
OO Water tanks
Protection: IP 66
Ball display model KG (max. L = 3 000 mm one-piece)* Limit contact model NBK-RV200NC
Material ball: Ultramid® B Sensor type: reed contact
Sight tube: Borosilicate glass Switching pattern: normally closed, bistable
Sealing plug: Stainless steel 1.4301 Other parameters: exactly as for NBK-RV200NO
Seal: FKM
Ball support rail: Aluminium, brown anodised
Limit contact model NBK-RN200NO
Carrier frame: Stainless steel 1.4301
Scale: Stainless steel 1.4301 Sensor type: NAMUR contact
Operat. temperature: -20 ... + 120 °C Switching pattern: normally open, bistable
Protection: IP 66 Max. operating voltage
* In case of multi-part design, a display (ball) length of 32 mm is not readable
Umax: 15 VDC
Ron: 1 kΩ
Roff: 11 kΩ
Technical Details additional Features
Other parameters: exactly as for NBK-RV200NO
Limit contacts, model NBK-R
Contact operation: bistable changeover contact Limit contact model NBK-RN200NC
Switching hysteresis: approx. 15 mm Sensor type: NAMUR contact
Max. switching capacity: 60 W/VA; 230 VAC/DC, 1 A Switching pattern: normally closed, bistable
Resistance: 100 mΩ Other parameters: exactly as for NBK-RV200NO
Medium temperature: - 40 ... +100 °C
Ambient temperature: - 40 ... + 75 °C Reed contact resistor chain model: ...W...
Connection: 3 m PVC-cable Total resistance: 0.7 ... 7 kΩ
Housing: Polycarbonate Meas. circuit voltage: max. 24 VDC
Protection: IP 67 Measuring current: max. 0.1 A
Max. length: 4000 mm
Limit contact high temperature, Medium temperature: - 40 ... +120 °C,
model NBK-RT200 Ambient temperature: max. 130 °C
Contact operation: bistable changeover contact Resolution: 10 mm
Switching hysteresis: approx. 15 mm Housing: Aluminium pressure-cast
Max. switching Cable gland: M16 x 1,5
capacity: 80 VA, 250 VAC/DC, 1 A Protection: IP 65
Resistance: < 20 mΩ
Medium temperature: - 40 ... + 120 °C Reed contact resistor chain with 2-wire transmitter
Ambient temperature: - 40 ... +145 °C model: ... M
Housing: Aluminium pressure-cast, terminal
Output: 4 ... 20 mA
connection
Supply voltage: 16 ... 32 VDC
Cable entry M16 x 1.5, brass nickel-plated
Max. length: 4000 mm
Protection: IP 65
Load: (VVers -9V) / 0,02 A [Ω]
Medium temperature: - 40 ... +120 °C
Limit contact model NBK-RV200NO Ambient temperature: - 20 ... + 80 °C
Sensor type: reed contact Resolution: 10 mm
Switching pattern: normally open, bistable Housing: Aluminium pressure-cast
Switching hysteresis: approx. 7 mm Protection: IP 65
Medium temperature: -50 ... +120 °C
Ambient temperature: - 40 ... +70 °C
Magnetostrictive sensor with 4-wire transmitter:
Max. housing
4 … 20 mA model: ...T...
temperature: +80 °C
Max. operating Output: 4 ... 20 mA
voltage Umax: 400 VDC / 250 VAC Supply voltage: 24 VDC, max. 150 mA
Max. load current Imax: 0.5 A Load: max. 500 Ω
Max. switching Max. length: 4000 mm
power Pmax: 5W Medium temperature: - 40 … +120 °C
Housing: Aluminium pressure-cast, terminal Ambient temperature: - 20 ... + 80 °C
connection Accuracy: ±1 mm
Protection: IP 65 Housing: Aluminium pressure-cast
Protection: IP 65
Take into account that none of the three parameters Umax,
Imax, Pmax may be exceeded!
1/01- 2016
Reed contact resistor chain with 2-wire transmitter: LED or LCD display (Options HE/HC):
4 … 20 mA model A Power supply: Loop powered
(only with display options AE or AC) Voltage drop: LED 3.3 V at 4 mA
Transmitter model: 5333D 3.7 V at 20 mA
Common specifications: LCD max. 2.5.V
Power supply: 8.0 ... 35 VDC
Communication Reed contact resistor chain with transmitter:
interface: Loop Link Model F (Profibus-PA®, Foundation™ Fieldbus®)
Linear resistance input: 0 … 10 kΩ Transmitter model: 5350A
Current output: Common specifications:
Signal range: 4 ... 20 mA Supply voltage: 9 ... 32 VDC
Min. signal range: 16 mA Consumption: < 11 m
Updating time: 135 ms Isolation voltage,
Load resistance: ≤ (Vsupply - 8 V) / 0.023 [Ω] test / operation: 1.5 kVAC / 50 VAC
Sensor error detection: Signal / noise ratio: min. 60 dB
Programmable: 3.5 ... 23 mA Response time
Medium temperature: - 40 … +120 °C (programmable): 1 ... 0 s
Ambient temperature: -20 … + 80 °C Updating time: < 400 ms
Resolution: 10 mm Dimension: Ø 44 x 20.2 mm
Housing: Aluminium pressure-cast Linear resistance input: 0 … 10 kΩ
Cable entry: M 20 x 1.5
Output:
Protection: IP 66
FoundationTM Fieldbus® connection:
LED or LCD display (options AE/AC):
FoundationTM
Power supply: Loop powered
Fieldbus® Version: ITK 4.51
Voltage: LED 3.3 V at 4 mA
3.7 V at 20 mA FoundationTM
Fieldbus® capability: basic or LAS
LCD max. 2.5 V
FoundationTM
Fieldbus® function blocks: 2 analogue and 1 PID
Reed contact resistor chain with 2-wire transmitter:
Profibus-PA® connection:
4 … 20 mA HART® model H and display options
Profibus-PA®
HE or HC
protocol standard: EN 50170 vol. 2
Transmitter model: 5337D
Profibus-PA®
Common specifications: function blocks: 2 analogue
Power supply: 8.0 ... 35 VDC Profibus-PA®
Communication address (at delivery): 126
interface: Loop Link 5905A and HART®
Medium temperature: - 40 … +120 °C
Linear resistance input: 0 … 7 kΩ
Ambient temperature: -20 … + 80 °C
Current output:
Resolution: 10 mm
Signal range: 4 ... 20 mA
Housing: Aluminium pressure-cast
Min. signal range: 16 mA
Updating time: 440 ms Cable entry: M 20 x 1.5
Load resistance: ≤ (Vsupply - 8 V) / 0.023 [Ω] Protection: IP 66
Sensor error detection:
Programmable: 3.5 ... 23 mA
Medium temperature: - 40 … +120 °C
Ambient temperature: - 20 … + 80 °C
Resolution: 10 mm
Housing: Aluminium pressure-cast
Cable entry: M 20 x 1.5
Protection: IP 66
1/01- 2016
Options
Code Discription Sketch/picture Availability
Scales
(Ball displays are always delivered with scales, see technical data/ sketch for resolution)
MV Scale made of stainless steel 1.4301 (option for roller
display KP/KM/KF
see sketch NBK-04
(Scale made of stainless steel 1.4301 standard with
roller display KG)
M1 Measuring scale, medium temperature
see sketch NBK-04
- 40 °C ... + 120 °C, engraved scale made of aluminium
M2 Measuring scale, medium temperature
- 40 °C ... +120 °C, scale see sketch NBK-04
backing made of aluminium with polyester foil
Electrical Outputs
MU Option M with connection box at bottom, for easy access to connection box NBK-04
Display options
AE Aluminium die-cast housing, LED digital display,
connection box at bottom (only in combination with NBK-04
transmitter option A)
AC Aluminium die-cast housing, LCD digital display,
connection box at bottom (only in combination with as AE, however with LCD display NBK-04
transmitter option A)
HE Aluminium die-cast housing, LED digital display,
connection box at bottom (only in combination with NBK-04
transmitter option H)
HC Aluminium die-cast housing, LCD digital display,
connection box at bottom (only in combination with as HE, however with LCD display NBK-04
transmitter option H)
C1) Indicating unit ADI-1V00W2F0 with bargraph and
digital display, rugged aluminium housing, mounted at see sketch NBK-04
bypass tube, for description see data sheet ADI-1
Tests / certificates
P Radiographic examination DIN 54 111 T1 - NBK-04
Q Dye penetration test DIN EN 571-1 - NBK-04
X Pressure test with water 1.5 x PN - NBK-04
Z 3.1 Inspection certificate acc. DIN EN 10204 - NBK-04
MR Material acc. to NACE MR 0103/ISO15156 (MR0175),
- NBK-04
declaration of conformance
WV Positive Material Identification (PMI) - NBK-04
SF Oil and fat free - NBK-04
1)
Only possible with option T (magnetostrictive sensor or option M (reed chain with transmitter)
Note: Please pay attention to max. permissible temperature limits of individual components
1/01- 2016
1,6
DN 50
1,5
1,4
) 3)
e
(kg/dm
trub
1,3
roodh
3
NBK-04...8
(kg/dm
n. R
Co
Flüssigkeit
1,2
Float: titanium
Dichtefluid
1,1
Connection rod: stainless steel, 1.4571
Density
1,0
0,9 pac
t Process connection: DIN EN 1092-1 flange, DN 50,
coem
dg
. rtoan ASME flange, 2"
0,8
C onS
0,7
Overhead and tank tube: Ø 60.3 mm, continuous
2600
2700
2800
2900
3000
3100
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
600
700
800
900
Measuring length
Messlänge (mm) (mm)
Min. medium density: 0.71 kg/dm3 at ML = 600 mm
NBK-04...6, Diagram 6
1,2
DN 50
1,1
NBK-04...6
er
3)
onit. aron
-R
1,0 CT
3
)
0,9
0,8
pgaect
Dichte
. arond-
Scotamn
ASME flange, 2"
Density
0,7 CoTnit
1300
1400
1500
1800
1900
2000
2300
2400
2500
2600
2800
2900
3000
3100
3300
3400
3500
3600
3900
4000
4100
1100
1200
1600
1700
2100
2200
2700
3200
3700
3800
600
700
800
900
Measuring length(mm)
Messlänge (mm) Min. medium density: 0.65 kg/dm3 at ML = 600 mm
NBK-04...4, Diagram 4
1,0
DN 65
0,9
NBK-04...4
tube Float: titanium
) 3)
ohdr
. ro
(kg/dm
0,8
C onR
3
0,7
Flüssigkeit
act
ogmep
roSdtacn ASME flange, 2½"
Con.
Density
0,5
2600
3400
3900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2200
2300
2400
2500
2700
2800
2900
3000
3100
3200
3300
3500
3600
3700
3800
4000
4100
600
700
800
900
*T
he floats could be adjusted to the densities above the graph
(Curve shifts upward)
1/01- 2016
1)
Only with options AE and AC
Please specify measuring length L, density, pressure, temperature and options in writing!
Dimensions
NBK-04...F50... NBK-04...F65... Required size of the mounting tube of the
vessel side
Ø 60,3 Ø 60,3
Over-Head Level Indicator
70
Final Final
70
Measurement
Messende Measurement
Messende
Measuring length
Messlängelength
Messlänge
Oberlänge
Over-length
Over-length
Oberlänge
Measuring
Initial Initial
Measurement Measurement
Messanfang
Messanfang
Ø 18
60*
60*
DN50/PN16 Ø 18 DN65/PN16
Final
50
Final Measurement
50
Measurement Messende
Messende
Ø 145
Ø 185
length
Ø 125
length
Unterlänge
Messlänge
Ø 165
length
Submersible
Messlänge
Unterlänge
Measuring
length
Initial
Measuring
Measurement
Messanfang
Minimum-Ø of the
270
Ø NBK-04
Flange mounting tube of
270
tube
the vessel side
PN 16 DN 50 Ø 60.3 mm Ø 76.1 mm x 2
* In case of using a transmitter:
dimension = 100/130 mm depending on transducer model
50
ML
lengthML
ML
20
Messlänge
length ML
Messlänge
Measuring
Measuring
10
100
20
0
cm
30
1/01- 2016
approx.
Measuring length ML
approx.
100
1/01- 2016
NBK-R NBK-RT200
switching point
NBK-RV/RN
approx. 98
switching point
1/01- 2016