LI66-10/350

Data Sheet
Strain gages (SG) for
integration in fiber
composite materials

Special features

− User can adapt the SG strain le-


vel through the embedding depth
− Measurement between glued joints
− Installation during the
manufacturing process
− SG protection in the material
− Flow profiles are not affected by
the measuring point
− Measurement at spots that are no
longer accessible after production

Dimensions (in mm; 1 mm= 0.03937 inches), specifications and design

d
Contact pins (gold−plated, insulated)

b Strain relief

Carrier foil (PI)

a Measuring grid
c

Types available ex stock Max. perm.


Nominal resi- Quantity per
Dimensions bridge excita-
Temperature response matched to: stance pack
tion voltage
Measuring grid Measuring grid carrier
Quartz Ω a b c d V
Order no. 1-LI66-10/350 350 10 3.2 22 10 2.5 5

B2158-1.1 en
Specifications 1)
Strain gage construction foil strain gages with covered measuring grid,
application of strain through the carrier foil

Connections mounted solder tabs with strain relief, connected


through to vertically mounted insulated contact pins

Measuring grid
material constantan
thickness µm 5

Carrier
material polyimide
thickness µm 50 ±5

Base foil
material polyimide
thickness µm 25 ±5

Nominal resistance Ω 350


Resistance tolerance % ± 0.35
Gage factor approx. 2, specified on each package
Gage factor tolerance % ±1
Temperature coefficient of the gage factor, approx. 1/K (115 ± 10) ⋅10−6
Nominal value of the temperature coefficient of the gage factor specified on each package
Reference temperature °C [°F] 23 [73.4]
Operating temperature range
for absolute, i.e. zero point related measurements °C [°F] -40 ... +180 [-40 ... +356]
for relative, i.e. not zero point related measurements °C [°F] -40 ... +180 [-40 ... +356]

Transverse sensitivity specified on each package


Temperature response specified on each package
Temperature response matched to the thermal expansion coef-
ficient a for quartz 1/K 0.5·10−6

Tolerance of the temperature response 1/K ± 0.3·10−6


Temperature response with matching in the range of °C [°F] -10 ... +120 [+14 ... +248]
Max. elongation
absolute strain value for positive direction¢ µm/m ±50.000 (¢ 5%)
absolute strain value for negative direction µm/m ±50.000 (¢ 5%)

Fatigue life,
at reference temperature using a
multidirectional CFRP sample
Reached nr. of load cyc. LW at alternat. strain ew = + 1000 mm/m a.
variation of zero point εm∆ x 100 µm/m 5 000 000
variation of zero point εm∆ x 300 µm/m 10 000 000

Minimum radius of curvature (longitudinal and transverse)


at reference temperature
within the measuring grid area mm 0.3
within the area of the solder area mm R
Bonding material that can be used Matrix resin
1) in accordance with OIML IR62

Modifications reserved. Hottinger Baldwin Messtechnik GmbH


All details describe our products in general form only. They
are not to be understood as express warranty and do not
constitute any liability whatsoever.
Im Tiefen See 45, D-64293 Darmstadt, Germany
Tel.: +49 6151 803-0 Fax: +49 6151 803 9100
B2158-1.1 en Email: support@hbm.com Internet: www.hbm.com