Professional Documents
Culture Documents
Design of Cantilever Slab As Per Is 456 2000
Design of Cantilever Slab As Per Is 456 2000
Design of Cantilever Slab As Per Is 456 2000
Reference : Reinforced concrete design IS:456 Principles and Practice by N.Krishna Raju-Ex. 9.4.2
Input slab Id S1
Characteristic cube strength of concrete fck = 15 N/mm2
Characteristic strength of steel fy = 415 N/mm2
Cantilever Projection L = 2.1 m
Over all Depth of slab @ support Ds = 240 mm
Over all Depth of slab @ Free end De = 120 mm
Floor finish load FF = 1.50 KN/m2
Live load LL = 2.0 KN/m2
UDL at Free End P = 0.0 KN/m
diameter of main reinforcement Φ1 = 10 mm
spacing of main reinforcement S1 = 220 mm
diameter of distribution reinforcement Φ2 = 10 mm
spacing of main reinforcement S2 = 270 mm
clear cover to Main reinforcement c = 20 mm
Anchorage length Ld = 475 mm
Modification factor for Tension rft. kt = 1.8 Fig 7.2
Modification factor for Compression rft. kc = 1
Ratio web width to flange width kf = 1
τbd = 2 Mpa Cl. 26.2.1.1
Load & Ultimate Moments
self weight of slab SW =0.5(Ds+De)*γc/1000
=0.5×(240+120)×25/1000 = 4.5 KN/m2
Ultimate Bending moment Mu =(1.5DL+1.5LL)*L^2/2+1.5*P*L
=1.5×(4.5+1.5+2.0)×2.1^2/2+1.5×0.0×2.1 = 26.5 KN/m2
Check for depth
effective depth d =Ds-c-Φ1/2
=240-20-10/2 = 215.0 mm
Minimum depth required for flexure dreq. =√(M/fck*b*d)
=sqrt(26.5×10^6/(0.138×15×1000)) = 113.1 mm OK
Reinforcement details
R =Mu/bd^2
=26.5×10^6/(1000×215.0^2) = 0.57 Mpa
Percentage of steel required Pt req =(1-√1-4.589*R/fck)*fck/(2*fy)
=(1-sqrt(1-4.589×0.57/15))×15/(2×415) = 0.0017
Area of tensile reinforcement required Ast req. =Pt req.*b*d
=0.002×1000×215.0 = 357 mm2/m
Minimum Area of tensile steel Ast min =0.12*b*d/100
=0.12×1000×215.0/100 = 258 mm2/m
Spacing of main reinforcement req. S1 req. =1000*π*(Φ1^2/4)/max(Ast req,Ast min)
=1000×(3.14×10^2/4)/max(357/258) = 220 mm
< 220 mm OK
Area of tensile reinforcement Provided Ast Pro =1000×(3.14×10^2/4)/220 = 357 mm2/m
Distribution steel
Area of distribution steel required Ast. Dist =0.12×1000×215.0/100 258 mm2/m
Spacing of distribution reinforcement req. S2 req =1000×(3.14×10^2/4)/258 304 mm2/m
Spacing of distribution steel provided S2 Prov. < 270 mm OK
Anchorage Length
Anchorage length required Ld req. =0.87×415×10/(4×1.92) = 470 mm
Anchorage length required Ld prov. > 475 mm OK
Check for deflection control
Percentage of tensile steel provided Pt =100×357/(1000×215.0) = 0.166
Allowable Span/depth ratio L/d max =L/d basic*kt*kc*kf
=(7×2×1×1) = 13
Span/depth provided L/d Pro. < 10 OK