Professional Documents
Culture Documents
536E4525 Gen Arr. RWF-II-222 Screw Compress.
536E4525 Gen Arr. RWF-II-222 Screw Compress.
REVISION HISTORY
ZONE REV ECN DESCRIPTION DATE DR CHK APPD
- - - - - - - -
H H
G G
10 3/8
7 3/4 17
50 1/8
F F
8 1/2
26 5/8
OIL COOLER
INLET/OUTLET
8
CUSTOMER NOTES:
1. NOTICE TO INSTALLER TO ALLOW ADJUSTMENT IN EACH PLANE FOR EXTERNALLY PREFABRICATED PIPING.
2. THIS COMPRESSOR PACKAGE MUST BE ANCHORED, SHIMMED AND GROUTED TO A SUITABLE FOUNDATION IN
ACCORDANCE WITH FRICK DOCUMENT S70-210IB, SCREW COMPRESSOR FOUNDATIONS.
3. MUST LEAVE HAND THROTTLING VALVE, ON MAIN OIL INJECTION LINE, FULLY OPEN AT INSTALLATION AND START UP.
18 1/16 4. DISCHARGE VALVE SHOWN IN OPEN POSITION.
5. ASSEMBLY SHOWN WITH COMPRESSOR SIZE - SGC 2317 AND MOTOR FRAME SIZE - LN5008TDZ.
6. UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS ARE CONSIDERED REFERENCE.
7. CUSTOMER CONNECTION DIMENSION TOLERANCE: +/- 1/2.
8. THE DIMENSIONS SHOWN FOR THE DOOR SWING ON THE ELECTRICAL PANELS DO NOT STIPULATE THE REQUIRED
2X 11 1/8 CLEARANCE FOR COMPLIANCE WITH THE NATIONAL ELECTRIC CODE (NEC) OR ANY LOCAL CODES.
E E
MANUFACTURING NOTES:
23 REQUIRED 1. PRODUCT DOCUMENTATION INCLUDING DRAWINGS ARE NOT INTENDED TO SUPERCEDE SAFE MANUFACTURING
FOR STRAINER PRACTICE. ANY DOCUMENT THAT INPLIES AN UNSAFE CONDITION MUST BE BROUGHT TO THE ATTENTION OF
SECTION A-A REMOVAL ENGINEERING FOR IMMEDIATE RESOLUTION.
2. FOLLOW FRICK STANDARD PROCEDURES FOR ASSEMBLY, PRESSURE TESTING, EVACUATION AND SHIPMENT.
COALESCER BLEED AND 3. PLACE NAMEPLATE 991A0083 AT THIS LOCATION, STAMP NAMEPLATE IN ACCORDANCE WITH DRAWING 720B0054.
DRAIN VALVE ORIENTATION 4. REFERENCE DRAWING 980A0038 FOR SEALING PLATE INSTALLATION.
5. DRAIN VALVE ASSEMBLY: CUT STUB (INCLUDING PIPE CAP) FROM DRAIN NOZZLE AND ATTACH TO VALVE. ATTACH
VALVE AND STUB ASSEMBLY TO REMAINING DRAIN NOZZLE ON SEPARATOR. VALVE SEAL CAP TO FACE THE QUANTUM
R18 SIDE OF THE UNIT.
39 REQUIRED FOR REMOVAL 2 x R22 13/16
6. PRIOR TO PERFORMING A HIGH PRESSURE TEST, THE ISOLATION VALVE TO THE LOW PRESSURE TRANSDUCER
OF OIL FILTER ELEMENTS
MUST BE CLOSED TO PREVENT DAMAGE.
SLIDE VALVE CYLINDER
7. THE FOLLOWING MMIB'S APPLY:
AND COALESCER ELEMENTS
MMIB 4.06.1.3 WELDING PACKAGE PIPING CARBON STEEL
MMIB 4.06.5.1 FERULOCK FITTINGS
MMIB 4.06.5.3 THREADING AND ASSEMBLY INSTRUCTIONS
MMIB 4.06.5.4 TORQUE PROCEDURE - CONTROL VALVES
138 5/16 MMIB 4.06.5.5 TORQUE PROCEDURE - SEQUENCE
MMIB 4.06.5.6 PIPE SEALANT - NEVER SEEZ/TEFLON TAPE
MMIB 4.09.7.11 PAINTING PARAMETERS FOR HIGH SOLID MATERIALS
MMIB 4.11.10.4 PACKAGE MICRO TEST PROCEDURE
MMIB 4.11.9.6 PACKAGE PRESSURE TESTING
D MMIB 4.11.9.7 TEST RUN PROCEDURE D
MMIB 4.13.2.2 UNIT TEST SEQUENCE
MMIB 4.06.05.12 MOTOR MOUNTING
98 7/8 82 1/4
MOTOR SUCTION
STARTER LEAD IN
7/8n PILOT HOLE
C 89 3/4 C
99 1/2
MAX HEIGHT
FOR ALL COMPRESSOR
RELATED PARTS
70
DISCHARGE
59 3/4
SAFETY
VALVE
55 A
QUANTUM
52 5/16
CG
44 5/16
2x 11 1/2 36 5/8
B B