Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Certificate no: 221875

Page 1 of 1

Initial Non Hazardous Tank Container Construction


Owners number Owner CSC type app no. GB-LR 60865/ 09/06
HCB-017 Halliburton Energy Services Inc.
Date
02/02/2007
Manufacturer’s serial number Manufacturer Customs Approval number
ST-3816 Suretank Ltd GB/C 60865 LR/2006
Description of tank LR office
Offshore Tank Container GB/C 60865 LR/2006
Tank
Code or standard PD5500:2006. cat 2
Dimensions: Length 5060 mm Diameter 2100 mm Capacity 16,180 litres
Material Shell EN10028:3 P355 NL1 Ends EN10028:3 P355 NL1 Heads / Baffles N/A

Actual thickness Shell 8.0 mm Ends min. A/F 8.0 mm Heads / Baffles N/A mm A/F
Corrosion allowance 2.00
Remarks
Hydraulic test pressure 11.55 bar Date of hydraulic test 23/01/2007
Working pressure RID / ADR 7.7 bar Working pressure IMDG 7.7 bar External pressure 0.42 bar
Leak test pressure 7.7 bar Leak test date 02/02/2007
Max. working temperature 55 °C Design temperature range 55°C
Heating system N/A Test pressure N/A bar Maximum working pressure N/A bar
Insulation N/A
Lining materials N/A
Remarks

Pressure Relief Devices

1 2 3
Make / Model Fort Vale High Pressure Relief Not Fitted
Description High Pressure Relief valve
Total vent capacity 8.951 m³/S
Set pressure / Vacuum 9.38/0.21 Bar
Remarks

Tank And Mainframe


Overall dimensions L 6058 mm W 2438 mm H 2591 mm GA Drawing no. ST-2720 Rev C
Maximum gross mass (R) 25,000 kg Tare weight 6,700 kg Maximum product load 18300 kg
Stacking capability 192,000 kg Stacking test load per corner 86,400 kg
Transverse racking test load 15,240 kg Lateral inertia test load 30,000 kg
Longitudinal inertia test load 30,000 kg Dynamic Test Value SRS N/A
Applicable Regulations DNV2.7-1:2006, BS EN: 12079:2006 , CE Marking & LRCCS

Approved Cargo References N/A

Remarks

This certificate is issued to the above client to certify that the tank container described herein, has been manufactured under survey in accordance with
Lloyd’s Register Group Container Certification Scheme and the International Convention for Safe Containers.
Digitally
signed by
On behalf of Danny Graham John Hendry
Inspector to Lloyd’s Register EMEA Date:
2013.04.29
Details of permanent marking attached 09/06 LR A member of the Lloyd’s Register Group 16:58:40
+01'00'

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Lloyd's Register'. Lloyd's
Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided,
unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms
and conditions set out in that contract.

Form 5216A (2012.08)