Instructions: Select the correct answer for each of the following questions. Mark only one answer for
each item by shading the box corresponding to the letter of your choice on the answer sheet provided.
STRICTLY NO ERASURES ALLOWED. Use pencil no. 2 only
PREBOARD 3: (PHILIPPINE ELECTRICAL CODE)
1. The National Electrical Code rules that apply to electric welders are covered in Article ______
a. 520 b. 600 c. 620 d. 630
2. What is the reason the code requires each separate phase conductor to be located in the same raceway?
a. To reduce inductive heat c. to improve workmanship
b. To provide identification of a circuit d. to assure balance resistance
3. The point of attachment of service drop conductors to a building or other structure shall in no case be less than _____
feet.
a. 10 b. 12 c. 15 d. 18
4. ______ of the following is a true statement
I. Wiring above a non-fire rated ceiling shall not be supported by the ceiling support wires.
II. Wiring above the fire rated ceiling shall not be supported by the ceiling support wires.
III. Cables and raceways shall be permitted to be supported by the ceiling grids
IV. The ceiling support Wires shall be permitted to support branch circuit wiring if in accordance with the ceiling
manufacturer’s instructions
a. I and II only b. II and III only c. IV only d. I, II, III and IV
5. An isolated ground receptacle shall be identified by ______
a. CO/ALR orange marking on the face of the receptacle
b. A metal faceplate not less than 0.030 inches in thickness
c. A reset test button the face of the receptacle
d. An orange triangle located on the face of the receptacle
6. _____ locations are those that are hazardous because of the presence of easily ignitable fibers or flyings.
a. Class I b. Class II c. Class III d. Class II, division II
7. The code is divided into the introduction and nine chapters. Chapter 1, 2, 3, and 4 apply generally and the latter
chapters supplement or modify the general rules except Chapter ____ which is independent of the other chapters where
specifically except where specifically referenced therein
a. 6 b. 7 c. 8 d. 9
8. Where lighting outlets are installed in interior stairways, there shall be a wall switch at each floor level to control the
lighting outlet where the difference between floor level is ____ steps or more
a. 1 b. 3 c. 5 d. 6
9. The installation of wiring and equipment for fire alarm systems including all circuits controlled and powered by the fire
alarm system is covered in article _____
a. 695 b. 710 c. 725 d. 760
10. Insulated conductors of # ____ or smaller, intended for use as grounded conductors of circuit shall have an outer
identification of white or natural gray color
a. 6 b. 4 c. 3 d. 1/0
11. A light fixture to be installed in a wet locations shall be ____
I. Installed so that water will not accumulate in wiring compartments
II. Installed so that water will not enter the wiring compartment
III. marked suitable for damp locations
a. I only b. I and II only c. II and III only d. I, II, and III
12. The general requirement for communications circuits such as telephone, telegraph, outside wiring for fire alarm and
burglar alarms is covered in covered in Article ____ of the NEC
a. 720 b. 725 c. 760 d. 800
13. The general requirements for all circuits and equipment operating at more than 600 volts nominal is mostly covered in
article _____
a. 695 b. 490 c. 725 d. 760
14. Thermal protection is required by the NEC for _____
I. Fluorescent lighting fixture ballast installed indoors
Prepared by: Jevan Ayco Calaque (BSEE, USEP BISLIG CLASS OF 2020)/ TOP 1 RME APRIL 2021
REGISTERED MASTER ELECTRICIAN EXAMINATION
P-12 Mancarogo Poblacion Bislig City Surigao del Sur
“Failure is not the opposite of success but a part of it”
Prepared by: Jevan Ayco Calaque (BSEE, USEP BISLIG CLASS OF 2020)/ TOP 1 RME APRIL 2021
REGISTERED MASTER ELECTRICIAN EXAMINATION
P-12 Mancarogo Poblacion Bislig City Surigao del Sur
“Failure is not the opposite of success but a part of it”
Prepared by: Jevan Ayco Calaque (BSEE, USEP BISLIG CLASS OF 2020)/ TOP 1 RME APRIL 2021
REGISTERED MASTER ELECTRICIAN EXAMINATION
P-12 Mancarogo Poblacion Bislig City Surigao del Sur
“Failure is not the opposite of success but a part of it”
[1-5] DAADD
[6-10] CCDDA
[11-15] BDBBD
[16-20] ABAAB
[21-25] BBAAB
[26-30] BBBCB
[31-35] AACCA
[36-40] DADAC
[41-45] DADBC
[46-50] BBACA