Indico Power Distribution Kit 208-480 Volt 3-Phase Only

You might also like

Download as pdf
Download as pdf
You are on page 1of 8
CPI Canada Inc. Supplement DIN POWER DISTRIBUTION KIT 739739-00 208-480 VAC 3 PHASE ONLY CONTENTS: 1.0 INTRODUCTION. 2.0 GENERAL. 3.0 THEORY OF OPERATION. 4.0 CONNECTIONS ON DIN POWER DISTRIBUTION, 5.0 EMC COMPLIANCE... 6.0 SPARES. = a “ 7.0 SCHEMATIC MD-0870 FORMS THE LAST PAGE OF THIS SUPPLEMENT. Indico Series Manual Supplement # 746100 Rev ANOT SIGNED OFF Paget CPI Canada Inc Supplement 4.0 INTRODUCTION This supplement contains interfacing and user information relating to the optional DIN power distribution kit 739739-00. This kit includes fuses, a 480VAC S-phase contactor and the schematic. HIGH VOLTAGE IS PRESENT ON THE CIRCUIT BREAKERS FUSES AND THE CONTACTOR AT ALL TIMES THAT THE GENERATOR IS CONNECTED TO LIVE AC MAINS. TAKE ALL APPROPRIATE HIGH VOLTAGE PRECAUTIONS DURING SERVICE / ADJUSTMENTS ON THESE COMPONENTS, AND WHEN WORKING NEAR THESE COMPONENTS. WHEN CONNECTING ADDITIONAL EQUIPMENT TO THE DIN DISTRIBUTION OUTPUT, IT IS THE RESPONSIBILITY OF THE INSTALLER TO VERIFY COMPLIANCE TO ALL THE LOCAL REGULATORY STANDARDS FOR SAFETY, EMC, AND HAZARD ANALYSIS/RISK ASSESSMENT OF THE FINAL SYSTEM CONFIGURATION. 20 GENERAL The components are mounted on a rail located to the right of the auxiliary transformer in the lower area of the generator cabinet. The DIN power distribution contains a 3-phase contactor that sources a switched 3- phase 480VAC up to 2.0 KVA dependant on the incoming line voltage. Refer to Figure 1 (GreUyEL TERQANAL LOCKS GROUND LUE TERMINAL BLOCKS NEUTRAL [aw ne] | Te] no connection comcron™3| | THREE PHASE | re] | "switeneD | Tal ostpur scone | meet rove ¢ aoe | La aeovac | Li=aovnc le A FIGURE 1: DIN Power Distribution Pictorial Indico Series Manual Supplement #746100 Rev A NOT SIGNED OFF Page 2 CPI Canada Inc ‘Supplement 3.0 40 THEORY OF OPERATION Refer to MD-0870 for interconnection details. In the generator the 3-phase 208 or 400 or 480VAG fused line is routed directly to a secondary 3-phase fuse assembly FSABC. The output of FSABC is connected to contactor K1, where the incoming line can be switched. On the contactor, At+ and A2- connect to the room interface board in the upper generator cabinet. ‘A2-to terminal TB7 (ground) ‘+ to terminal TB8 (+24 VDC) ‘Switching the generator ON supplies 24 VDC to energize K1., Switched 3-phase power is then available for external 3-phase equipment connected to K1 at T1, T2, and T3, Terminal blocks marked N (blue) are connected to the Neutral Terminal on the Power Input PWBA and are available for external equipment neutral connections. Terminal blocks marked PE (green/yellow) are connected to chassis ground and are available for external equipment ground connections. CONNECTIONS ON DIN POWER DISTRIBUTION THE HIGH VOLTAGE 480VAC POWER IS PRESENT AT ALL TIMES THAT THE GENERATOR IS CONNECTED TO LIVE AC MAINS. TAKE ALL APPROPRIATE HIGH VOLTAGE PRECAUTIONS DURING SERVICE / ADJUSTMENTS ON THESE COMPONENTS. THE HIGH VOLTAGE 480VAC POWER ON THE LINE SIDE OF K1 IS PRESENT AT ALL TIMES THAT THE GENERATOR IS CONNECTED TO LIVE AC MAINS. THE HIGH VOLTAGE 480VAC POWER ON THE SWITCHED SIDE OF K1 IS PRESENT ONLY WHEN THE GENERATOR IS SWITCHED ON. TAKE ALL APPROPRIATE HIGH VOLTAGE PRECAUTIONS DURING SERVICE / ADJUSTMENTS ON THESE COMPONENTS. Connections for external 3-phase 480 VAC equipment are made to K1-T1, T2 & T3 on the DIN rail. The switched loading available is 2.0kVA maximum. Refer to Figure 3. ‘The ground connections for all external equipment are made to terminal blocks marked PE on the DIN rail. Refer to Figure 3 External equipment cables can be connected to the DIN rail components by routing them into the generator cabinet by four recommended paths below. 41. Through the mains cable clamp. 2. Through the opening for the High Voltage cables. 3. Through the optional knockout above the mains cable clamp, 4. Through the opening in the floor near the mains cable clamp. Route the cables on the cabinet floor between the Power Input Board panel & the HV Tank and continue the routing around the panel as shown in Figure 2. Tndico Series Manual Supplement # 746700 Rev A NOT SIGNED OFF Page 3 CPI Canada Inc Supplement FIGURE 2: DIN Power Distribution Lead Dress Indico Series Manual Supplement # 746100 Rev A NOT SIGNED OFF Page 4 CPI Canada Inc ‘Supplement Route the cables up to the contactor terminals T1, T2 & T3. The contactor is shown in Figure 3, FIGURE 3: DIN Power Distribution Tndico Series Manual Supplement # 746100 Rev A NOT SIGNED OFF Page 5 CPI Canada Inc ‘Supplement 5.0 EMC COMPLIANCE ‘The generator complies to the IEC/EN 60601-1-2 standard. Connecting external equipment to the DIN power distribution outputs will require recertification of EMC to the regulation standard. FOR CONNECTING EXTERNAL EQUIPMENT TO THE DIN POWER DISTRIBUTION OUTPUT, IT IS THE RESPONSIBILITY OF THE INSTALLER TO VERIFY COMPLIANCE TO THE IEC/EN 60601-1-2 STANDARD AT THE FINAL SYSTEM CONFIGURATION. 60 SPARES The complete assembly includes the contactor, fuses, and the fuse holders shown in FIGURE 1. The fuses supplying power to the 3-phase contactor is FSABC. Description CPI Pari Number | Quantity FUSE FSABC (6741905500 3 ATOA0 FUSE HOLDER {5520035300 7 F5ABC ‘CONTACTOR 7256202000 7 Kt 7.0 SCHEMATIC MD-0870 FORMS THE LAST PAGE OF THIS SUPPLEMENT. Tndico Series Manual Supplement # 746100 Rev ANOT SIGNED OFF Page 6 CPI Canada Inc FBAC- 208- asovac-| F58.0——— POWER INPUT BOARD sco ‘SCHEMATIC DIN POWER DISTRIBUTION wossro revs’ 2 ‘SHEET 10F 1 ‘Indico Series Manual Supplement #746100

You might also like