Professional Documents
Culture Documents
Series 4300 Pneumatic Pressure Controller: Reliable Performance
Series 4300 Pneumatic Pressure Controller: Reliable Performance
Pressure Controller
Reliable Performance:
Rugged construction and dependable operation
Engineered
Performance
2 Specifications (continued)
Dimensions
8.13 4.36
4.13 1
3.95 – – 18 NPT
4.00 4
1.90
8.13
7.98
5.57 8.01
1
– – 27 NPT
8
1
– – 18 NPT
4
Model Options 3
Series 4302
This model provides hi-low with cutout on high
and low set point. It is designed to output a signal 4300 Direct 4300 Reverse
to the control valve when the controlled process
pressure falls below the low-pressure set point or
rises above the high-pressure set point, used in
conjunction with a normally closed control valve.
The High set point proportional band is 20% to
90% of the Bourdon tube range. The Low set point
is 5% of the Bourdon tube range to 5% of this
maximum range below the high set point. This
model has an intermittent bleed orifice. When
used with a fail-closed valve, a relay is required.
4302 Direct 4302 Reverse
Series 4302R
This model provides proportional control with out-
put signal cutout on low input signal. It is designed
to cutout (output) pressure below low pressure to
the control valve when the controlled pressure
falls below the set point. It has a fixed bleed orifice
and 2% to 50% proportional band.
Available Configurations
1. Series 4300 and 4300R – proportional control Note: When a diaphragm seal is required to isolate
with constant bleed, direct or reverse action. the Bourdon tube, add the suffix “S” to the series
number (i.e., 4300RS)
2. Series 4302 – on/off with cutout on high set
point, direct action (reverse relay required).
3. Series 4302R – Proportional control with
constant bleed, incorporating low pressure
cutout, reverse action.
2 How to Order
PRESSURE
PSIG Rating Rating Code
50 005
ACTION TYPE
100 010
Code Action
250 025
D Direct
500 050
R Reverse
1000 100
1500 150
2500 250
5000 500 100 - 3S - D 3 A
7500 750
NOZZLE SIZE
Code Size
B 0.040 Diameter
Service Code
Standard –
NACE N
316 SST 3S 3 3 - 15
6 6-30
Please note: not all available options are shown.
Engineered Performance
11122 West Little York • Houston, Texas 77041
Tel: 713·466·3552 • Fax: 713·896·7386
www.norriseal.com
©2015 Dover Corporation/Norriseal and its affiliates. This manual, including all text and Due to the continuous improvement program at Norriseal, specifications and/or prices
images, is a copyrighted work of Dover Corporation/Norriseal and its affiliates. It may are subject to change without notice or obligation.
not be, in whole or in part, photocopied, scanned, or otherwise reproduced, revised,
or publicly displayed, without prior written permission from Norriseal. This manual is All trademarks contained herein are the property of their respective owners.
for use only with the new Norriseal valves and/or controllers listed in the manual. It
may not be distributed with, and is not for use with, any remanufactured products. 4300-0215T