Technical Specification

MMC BWMS 150m³/h, skid mounted

Document ID TS MMC BWMS 150m³h 1520


Rev Reason for Issue Prepared Approved Date

1 Pump is DN50 SGV BG 12.06.2018


- First issue SGV TG 06.04.2018
MMC BWMS 150m³/h

Table of content
1. Introduction ...................................................................................................... 3
2. Scope of Supply ................................................................................................. 4
3. Design Criteria ................................................................................................... 5
4. Ship Interface .................................................................................................... 6
5. Attachments ..................................................................................................... 7

Page | 2
MMC BWMS 150m³/h

1. Introduction

The system is designed for treatment of 150m³/h raw water to meet the IMO
GUIDELINES FOR APPROVAL OF BALLAST WATER MANAGEMENT SYSTEM (G8) and
DNV STANDARD FOR CERTIFICATION No 2.4 and DNV Type Approval Programme
No 771.91

The system is a skid mounted assembly consisting of an automatic back flush filter,
back flush pump, UV unit, flow meter, control- and power cabinets. Necessary
valves, inline piping and connections fitted.

The system to be controlled by computer based software, operated from the


bridge or locally at the plant, with logging of alarms, operating mode, registration
of either pumping to tank or overboard, and the volume of water pumped.

During ballasting the water will first be filtered through a 40 micron filter, to
remove larger particles and the majority of the zoo‐plankton. After the filter, the
water will enter the UV‐reactor(s) and will be exposed to a high dose of UV light.
The UV‐irradiation will kill or inactivate the remaining plankton as well as bacteria
and viruses.

Page | 3
MMC BWMS 150m³/h

2. Scope of Supply

One skid mounted BWMS.

System consisting of following main components:

Qty. Equipment Weight Tot. Weight Comment


1 Filter unit 400 kg 400 kg
1 UV unit 75 kg 75 kg
1 UV unit control 285 kg 285 kg
cabinet
1 Control cabinet 50 kg 50 kg
1 Flow meter 30 kg 30 kg
4 DN 150 Butterfly 25 kg 25 kg Pneumatic
valves LUG operated
1 DN 150 30 kg 30 kg El. Operated
Butterfly valves
LUG
1 DN 100 Butterfly 14 kg 14 kg Pneumatic
valve LUG operated
3 DN 15 Ball valves 2 kg 6 kg Pneumatic
(½” pipe thread) operated
2 ½” Valves 2.2 kg 4.4 kg Pneumatic
3 – way(L type) operated
1.5 m Rest piping v/flanges 35 kg 35 kg Approx.
2 T- pipes v/flange 45 kg 90 kg Approx.
1 Back flush pump 40 kg 40 kg
1 Base frame 80 kg 80 kg Approx.

Total 1180 kg Approx.

Page | 4
MMC BWMS 150m³/h

3. Design Criteria

Description Specification Comment


Max. flow (TRC) 150m³/h
Min. flow filling 80m³/h
Min. flow discharge 10m³/h
Max. pressure 10 bar PN10
Min. pressure 1 bar
IP Class 44 Lowest
Ballast water -2-50°C
temperature
Ambient temperature 55 °C El. components
Filtration 40 µm
Pressure Loss 0,4 bar Approx.
Max power requirement 20 kW Approx.
Power consumption UV 8/14 kW Min/Max

Page | 5
MMC BWMS 150m³/h

4. Ship Interface

Piping:

 DN 150 pipe, PN 10 flange, Inlet pipe ballast water


 DN 150 pipe, PN 10 flange, Outlet pipe ballast water
 DN 50 pipe, PN 10 flange, Back flush overboard, drain overboard
 DN 15 pipe, for fresh water supply
 DN 15 pipe, air evacuation to bilge well or open deck
 DN 15 pipe, 6-8 bar for pressurized air supply

All pipe connections to be supported with clamps outside the skid.

Electrical supply:

 1 X 440V 63A 3 phase for UV cabinet


 1 x 440V 32A 3 phase for node cabinet
 1 X 24V UPS for Node cabinet
 Communication cable IAS (optional)

All cable inlets trough bottom of cabinets.

Page | 6
MMC BWMS 150m³/h

5. Attachments

Drawings:

 Dimensional Sketch BWMS 150m³/h


 P&ID

Page | 7
6 5 4 3 2 1

1254

B ( 1 : 10 )
D Pipe DN150, L-200mm D
Hot dip galvanised Steel
Outlet DN150 Shipyard delivery
2211

1791
B
Flowmeter DN150
200

905 COG
C C

Inlet DN150 500


395
276

58
210 Backflush Overboard 693 COG 97
DN50
A 539 A 132
1522

1983

Minimum distance for service area:


B A ( 1 : 20 ) 800mm from UV cabinet
B

800
Minimum distance for service area:
600mm from control cabinet

Footprint
1120

Date Signatur M lestokk Ark


427 COG

MMC GREEN
TECHNOLOGY AS
100 Tegnet 03.12.2018 apa N-6092 Fosnav g
1:20 1 /2 TLF: +47 81570002
Kontrollert FAX: +47 70083950
160

office@mmc.no

733 COG
MMC BWMS 150 NFilter-V Tegningsnummer Revisjon
A Dimensional Sketch A
D1520 C
Varenummer Format Ref. Tegning Pos Prosjekt
A3
ACCORDING TO INTERNATIONAL LAWS THIS DRAWING/SPECIFICATION IS THE PROPERTY OF MMC GREEN TECHNOLOGY AS. THE
DRAWING/SPECIFICATION AND CONTENTS CAN NOT BE MADE PUBLIC, COPIED OR OTHERWISE USED, WITHOUT OUR WRITTEN CONSENT.
6 5 4 3 2 1
6 5 4 3 2 1

Service area: Service area:


D 200mm 200mm D
294

152,3

22
373

C C

DN 150

2
IMPORTANT FOR INSTALLATION!

Direction of the liquid in the sensor indicated by the arrow.


Minimum straight lenght of pipe: 750mm before flow meter and 450mm after flow meter.
B B
Parts List
PART
ITEM QTY DESCRIPTION MATERIAL
NUMBER
1 1 1 1088 Magnetic flow meter Liner: Ebonite
MUT2200EL-DN150-PN10 Flow tube: 304SS
285

Coil housing: S235


Flanges: Carbon steel
Electrode: Hastelloy C22
2 1 1002 Converter MC608A Aluminium
Date Signatur M lestokk Ark MMC GREEN
TECHNOLOGY AS
Tegnet 03.12.2018 apa N-6092 Fosnav g
1:4 2 /2 TLF: +47 81570002
Kontrollert FAX: +47 70083950
office@mmc.no
MMC BWMS 150 NFilter-V Tegningsnummer Revisjon
A 300 Dimensional Sketch A

Flowmeter DN150 D1520 C


Varenummer Format Ref. Tegning Pos Prosjekt
A3
ACCORDING TO INTERNATIONAL LAWS THIS DRAWING/SPECIFICATION IS THE PROPERTY OF MMC GREEN TECHNOLOGY AS. THE
DRAWING/SPECIFICATION AND CONTENTS CAN NOT BE MADE PUBLIC, COPIED OR OTHERWISE USED, WITHOUT OUR WRITTEN CONSENT.
6 5 4 3 2 1

You might also like