Recommendations can be

1.pwrAdm can be increased from 75 to 85.


2.40W license upgrade.
3.Higher SF admission can be restricted. Ex: sf8Adm, sf4AdmUl, sf16Adm, sf8AdmUl…
4.Physical optimization.
5.Alarm clearance.
6.License loading.
7.Power parameter discrepancy clearance.
8.primaryCpichPower can be reduced.
9.New site can be recommended if power congestion still exists after the above all steps
implementation.

Code congestion:
Observations can be
1.Check the dlCodeAdm parameter discrepancy.
2.Check primaryCpichPower discrepancy.
3.Check for alarms.
4.Check for licenses.
5.Check the propagation delay.
6.Check the cell fluctuations (auto downtime and manual downtime).

Recommendations can be
1.dlCodeAdm can be increased from 70 to 85.
2.Higher SF admission can be restricted. Ex: sf8Adm, sf4AdmUl, sf16Adm, sf8AdmUl…
3.Physical optimization.
4.Alarm clearance.
5.License loading.
6.dlCodeAdm parameter discrepancy clearance.
7.primaryCpichPower can be reduced.
8.New site can be recommended if Code congestion still exists after the above all steps
implementation.
UL/DL CE congestion: Observations can be
1.Check the dlHwAdm and ulHwAdm parameter discrepancy.
2.Check primaryCpichPower discrepancy.
3.Check for alarms.
4.Check for licenses.
5.Check for DUW discrepancy.
6.Check the propagation delay.
7.Check the cell fluctuations (auto downtime and manual downtime).

Recommendations can be
1.Physical optimization.
2.UL/DL CE license upgrade (128/256 to 256/384 on DUW20). If site has DUW10, DUW to be
upgraded to DUW20. If site is RBS3000, RAX/TX board addition.
3.Higher SF admission can be restricted. Ex: sf8Adm, sf4AdmUl, sf16Adm, sf8AdmUl…
4.Alarm clearance.