MULTI RANGE, DOUBLE TIME

DRN.G ADJUSTED FLASHER RELAY

It is microprocessor controlled. By using the (Mon) and (Moff) control knobs on the
front side of the unit, 6 different ON time intervals and OFF time intervals can be
selected. The selection of ON and OFF time intervals is made independently of each
other. Two different operation selections can be made to start with ON start or OFF Technical Data
start with the function(F) setting knob. Their operating charts are given below.

F FUNCTION (Operation Mode) :


The start of flasher relay is selected as On start or Off start.

ON start OFF start


Operational Voltage (Un)
t O U t O U A1 – A2 terminals : 230 Vac (50/60Hz)
O FFS t a r

O FFS t a r
N

N
A3 – A2 terminals : 24 Vac or 24 Vdc
St a r t

St a r t
Operating Range : (0,9-1,1) x Un
Frequency : 50/60 Hz
18 18
15 15 Contact Current : Max. 5 A / 250 VAC
16 16
Power Consumption : < 4 VA
Device Protection Class : IP20
t(on) t(off) t(on) t(off) t(off) t(on) t(off) t(on) Connector Protection Class : IP00
Ambient Temperature : -20°C....+60°C
Connection Type : To connection rail
in electrical panel
M THE TIME INTERVAL SELECTION: (MODE): Dimensions : 18x90x65 mm
With the mode potentiometers on the front of the device, the required time mode is
A1 A2 A3
selected for M (on) and M (off).

65mm
10s – 30s

31mm
1m – 30m 230V AC 24VAC/DC
36mm
1h – 30 h
Max. 5A / 250Vac 90mm
T USE OF TIME SETTING SCALE:
44mm
The scale of the time potentiometers (Tone and Toff) on the device is between 0,1

18mm
and 1. The time setting of the device starts at 1% of the time indicated by the mode 18 15 16
potentiometer and can be set to 100% with 1% steps.
65mm

Definition
www.kael.com.tr If ; M(on) = 30s M(off) = 1h
info@kael.com.tr T(on) = 0.6 T(off) = 0.5
Made in
TURKEY 1h 30h 0.8 1h 30h 0.8
1 1
30m 0.6 30m 0.6
t(on) = M x T t(off) = M x T
1m O 0.4 O 1m O 0.4 O
N N F F
30s 10s 0.1 30s 10s 0.1 F
0.2 F 0.2

t(on) = M(on) x T(on) t(off) = M(off) x T(off)


t(on) = 30sn x 0.6 = 18s t(off) = 1sa x 0.5 = 0.5h = 30m