RAT Parameter Name Parameter ID

FDD

Intelligent power-off of carriers switch CellShutdown.CellShutdownSwitch


TDD

FDD

Start time CellShutdown.StartTime


TDD

FDD

Stop time CellShutdown.StopTime


TDD

FDD

Downlink PRB threshold CellShutdown.DlPrbThd


TDD

FDD

Downlink PRB offset CellShutdown.DlPrbOffset


TDD

FDD

Uplink PRB threshold CellShutdown.UlPrbThd


TDD

FDD

Uplink PRB offset CellShutdown.UlPrbOffset


TDD

FDD

UE Number Threshold CellShutdown.UENumThd


TDD

FDD

Force Shutdown UE Number Threshold CellShutdown.ForceShutdownUENumThd


Force Shutdown UE Number Threshold CellShutdown.ForceShutdownUENumThd
TDD

FDD

Punish Time CellShutdown.PunishTime


TDD

FDD

Inter-BBU Carrier Shutdown Switch CellShutdown.InterBbuCarrierShutdownSw


TDD
Setting Notes

The value ON is recommended.

Set this parameter to its recommended value for a capacity cell.

This parameter does not need to be set for a basic cell.

Set this parameter to its recommended value.

0 is recommended for basic cells and 20 is recommended for capacity cells.

To prevent the impact on MLB features, the uplink and downlink PRB usage thresholds for triggering intelligent power-off of c

The sum of this parameter value and the Downlink PRB threshold parameter value specifies
the downlink PRB usage threshold for stopping intelligent power-off of carriers in the same
coverage.

Before powering off a carrier, the eNodeB predicts the downlink PRB usage of the target cell.
Intelligent power-off of carriers in the same coverage is started only when the predicted
downlink PRB usage of the target cell is less than the sum of downlink PRB usage threshold
and downlink PRB usage offset. This prevents the powered-off carrier from being powered on
again due to high downlink PRB usage after UEs are handed over to the target cell.

0 is recommended for basic cells and 20 is recommended for capacity cells.

To prevent the impact on MLB features, the uplink and downlink PRB usage thresholds for triggering intelligent power-off of c

The sum of this parameter value and the Uplink PRB threshold parameter value specifies the
uplink PRB usage threshold for stopping intelligent power-off of carriers in the same coverage.

Before powering off a carrier, the eNodeB predicts the uplink PRB usage of the target cell.
Intelligent power-off of carriers in the same coverage is started only when the predicted uplink
PRB usage of the target cell is less than the sum of uplink PRB usage threshold and uplink
PRB usage offset. This prevents the powered-off carrier from being powered on again due to
high uplink PRB usage after UEs are handed over to the target cell.

This parameter specifies the UE number threshold for the intelligent power-off of carriers in the
same coverage function. Set this parameter to its recommended value.

Set this parameter to its recommended value.


Set this parameter to its recommended value.

Set this parameter to its recommended value.

It is recommended that this switch be turned on when the capacity cell and its neighboring
basic cells are served by different BBUs of macro eNodeBs.