GENERAL NOTES :

1. ALL PLUMBING WORKS TO BE DONE AND SIZES OF PIPES


TO BE USED SHALL BE IN ACCORDANCE WITH THE LATEST
EDITION OF THE NATIONAL PLUMBING CODE OF THE
PHILIPPINES AND LOCAL REGULATIONS AND ORDINANCES.
2. ALL PIPES SHALL BE INSTALLED AS INDICATED IN THE
WORKING DRAWINGS. ANY RELOCATION REQUIRED FOR
PLAN
PROPER EXECUTION OF OTHER TRADES SHALL BE UPON
THE APPROVAL OF THE SANITARY ENGINEER.
3. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER
SCALED DIMENSIONS.
4. ALL PIPES SHALL BE PROVIDED W/ PROPER HANGER AND
SUPPORT
5. ALL FIXTURES SHALL BE VENTED INDIVIDUALLY AND
WATERLINES SHALL BE VALVE BY GROUP PLAN SPOT DETAIL
6. UNLESS OTHERWISE SPECIFIED, ALL PLUMBING FIXTURES
SHALL BE PROPERLY VENTED. MAXIMUM DISTANCE OF
VENTILATION FROM FIXTURES SHALL BE 1.50 m MEASURED
ALONG THE LENGTH OF PIPE.
7. ALL PLUMBING FITTINGS SHALL BE ACCESSIBLE FOR
MAINTENANCE. PROVIDE MANHOLE IF SUCH
INSTALLATIONS ARE INSIDE THE CEILING.
SECTION
8. ALL CHANGES IN DIRECTIONS SHALL BE MADE BY THE
APPROPRIATE USE OF FORTY FIVE (45) WYE LONG SWEEP
QUARTER BEND. ONE EIGHT WHEN THE CHANGE OF FLOW
IS FROM HORIZONTAL TO VERTICAL A SINGLE BEND
COMBINATION MAY BE USED ONLY ON VENT PIPE.
PLAN SECTION
9. NO DOUBLE HUB OR DOUBLE TEE BRANCH SHALL BE USED
ON HORIZONTAL SOIL OR WASTE LINES.
10. PROVIDE PIPE SLEEVES AT WALL, COLUMNS OR SLAB TO
PROTECT FROM BREAKAGE.
11. ALL EXPOSED PIPINGS AND FITTINGS IN THE AREAS SHALL
BE CHROME PLATED. LENGTH WIDTH DEPTH
PARTICULARS
12. THE BRAND AND OTHER DETAILED PLUMBING FIXTURES SECTION 2.40 2.90 3.00 3.50 3.90 4.00 4.30 5.00 1.50 1.60 2.00 2.50 2.80 3.00 1.00 1.20 1.40 1.50 1.70 1.80
SHALL BE IN ACCORDANCE WITH THE SCHEDULE THICKNESS, T1 MM 150 150 150 175 175 200 200 200 150 150 150 150 175 175
FURNISHED BY THE ARCHITECT. SECTION THICKNESS, T2 MM 150 150 150 150 150 175 175 175 150 150 150 150 175
13. GATE VALVE SHALL BE BRONZE BODY, SOLID WEDGE
THICKNESS, T3 MM 200 200 200 225 225 250 250 250
TYPE, SCREWED OR FLANGE END.
14. USE POLYPROPYLENE RANDOM,TYPE 3,PN20 FOR ALL 4 AIR CHAMBER DETAIL 5 CLEAN-OUT DETAIL 200 175 175 150 150 125 125 112
WATER PIPING SYSTEM. P-1 SCALE NTS P-1 SCALE NTS 200 200 200 175 150 150
15. USE uPVC SANITARY PIPING SYSTEM SERIES 1000 FOR 100
1 CATCH BASIN DETAIL 200 200 175 175 175 150 150 150
200 200 150 150 125 125
P-1 SCALE NTS
VERTICAL BARS, 12MM 200 200 200 175 150 150
16. ENGINEER-IN-CHARGE TO VERIFY ACTUAL LOCATION AND
ELEVATION OF STREET DRAINAGE, STREET SEWER AND HORIZONTAL BARS 12MM 200 200 200 200 175
STREET WATER MAINS FOR CONNECTION BEFORE
CONSTRUCTION.

LEGEND: 8 TYP. UNDERGROUND WATER TANK DETAIL (DOMESTIC)


P-1 SCALE NTS
WATER DISTRIBUTION SYSTEM PLAN
WATERLINE
FIRELINE
GV GATE VALVE
FV FLOAT VALVE
WSP WET STAND PIPE RISER / DF /
DESIGNATION CAPACITY SERVICE PIPE (mm)
DSP DRY STAND PIPE SUPPLY PIPE (mm)
FHC FIRE HOSE CABINET 3-STOREY / 3 CLASSROOM 5400 L
BI BLACK IRON PIPE 3-STOREY / 6 CLASSROOM 10800 L
WASTE, SEWER & VENT SYSTEM 3-STOREY / 9 CLASSROOM 16200 L
SANITARY LINE 3-STOREY / 12 CLASSROOM 21600 L
VENT LINE 3-STOREY / 15 CLASSROOM 27000 L
FCO FLOOR CLEAN-OUT

FD SHOWER/FLOOR DRAIN
PLAN
VS VENT STACK
SS SOIL STACK 9 UNDERGROUND WATER TANK CAPACITY (DOMESTIC)
VAC VENT ACROSS CEILING SECTION P-1 SCALE NTS
VP VENT PIPE
PVC POLYVINYL CHLORIDE
WP WET PIPE SCHEDULE OF DIMENSIONS
SP SOIL PIPE
VTR VENT THRU ROOF PIPE DIMENSION IN MM
SIZE IN
ST SEPTIC TANK 'A' D F DESIGNATION L W H
AC AIR CHAMBER 50 100x100 225.42 3-STOREY / 3 CLASSROOM 2.90 1.60 1.20
WASTE, SEWER & VENT SYSTEM 75 125x125 225.42 3-STOREY / 6 CLASSROOM 3.00 2.50 1.40
DRAINAGE LINE 3-STOREY / 9 CLASSROOM 3.90 2.80 1.50
100 150x150 225.42
DS DOWNSPOUT 150 200x200 282.57
3-STOREY / 12 CLASSROOM 4.30 3.00 1.70
3-STOREY / 15 CLASSROOM 5.00 3.00 1.80
CB CATCH BASIN

RD ROOF DRAIN
2 FLOOR DRAIN DETAIL
CD CORRIDOR DRAIN P-1 SCALE NTS

PLUMBING FIXTURES 10 UNDERGROUND WATER TANK DIMENSION (DOMESTIC)


LAV LAVATORY P-1 SCALE NTS
WC WATER CLOSET
EWT ELEVATED WATER TANK
SECTION
6 TYPICAL SEPTIC TANK DETAIL
P-1 SCALE NTS

DESIGNATION CAPACITY
L W H Lc
3-STOREY / 3 CLASSROOM 1350 L
3-STOREY / 3 CLASSROOM 3.30 2.00 1.50 1.50 2700 L
3-STOREY / 6 CLASSROOM
3-STOREY / 6 CLASSROOM 4.80 2.50 1.80 1.80 4050 L
3-STOREY / 9 CLASSROOM
3-STOREY / 9 CLASSROOM 6.50 2.50 2.00 1.50
3-STOREY / 12 CLASSROOM 5400 L
3-STOREY / 12 CLASSROOM 6.60 3.00 2.00 1.80
3-STOREY / 15 CLASSROOM 6750 L
3-STOREY / 15 CLASSROOM 7.00 3.50 2.20 2.00

11 ELEVATED WATER TANK CAPACITY (DOMESTIC)


3 ROOF DRAIN DETAIL 7 SEPTIC TANK DIMENSION P-1 SCALE NTS

P-1 SCALE NTS P-1 SCALE NTS

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH GEN. NOTES & LEGEND, MISC. DETAILS,
PROPOSED PROJECTS TYP. SEPTIC TANK DETAIL,
ROMEO C. OCAMPO PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) SEPTIC TANK DIMENSION, BOD 31
STANDARD THREE-STOREY
PLUMBING DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING
UNDERGROUND WATER TANK DETAIL, P-1
POSITION: SANITARY ENGINEER UNDERGROUND WATER TANK CAPACITY, 44
PRC No.: 000697 TIN No.: 131-678-239 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 6-CLASSROOMS ) UNDERGROUND WATER TANK DIMENSION,
PTR No.: 2181627 BUILDINGS DIVISION, BOD (REVISED 3-24-17) ELEVATED WATER TANK DIMENSION